908 resultados para IMPLANTED DEVICE
Resumo:
BACKGROUND: Complications associated with intrathecal pumps may be linked to the surgical procedure, the implanted device, or the medication itself.¦CASE REPORTS: Three patients treated chronically with intrathecal clonidine presented with clonidine overdose due to inadvertent extravasation during the refilling procedure. All patients experienced loss of consciousness and severe systemic hypertension that required aggressive parenteral treatment.¦DISCUSSION: Clonidine is an alpha-2 agonist with a nearly 100% bioavailability after oral or rectal administration. With high plasma concentration secondary to massive systemic overdose, the specificity for the alpha-2 receptor is lost and an alpha-1 agonist activity predominates and causes marked hypertension. Management of clonidine overdose consists of supportive therapy guided by signs and symptoms.¦CONCLUSION: Inadvertent injection into the subcutaneous pocket rather than the reservoir is rare but very dangerous as the drug cannot be retrieved and massive doses are involved. Signs and symptoms of systemic overdose with drugs commonly used in implanted drugs delivery system should be well known to ensure early diagnosis and treatment.
Resumo:
Electrical deep brain stimulation (DBS) is an efficient method to treat movement disorders. Many models of DBS, based mostly on finite elements, have recently been proposed to better understand the interaction between the electrical stimulation and the brain tissues. In monopolar DBS, clinically widely used, the implanted pulse generator (IPG) is used as reference electrode (RE). In this paper, the influence of the RE model of monopolar DBS is investigated. For that purpose, a finite element model of the full electric loop including the head, the neck and the superior chest is used. Head, neck and superior chest are made of simple structures such as parallelepipeds and cylinders. The tissues surrounding the electrode are accurately modelled from data provided by the diffusion tensor magnetic resonance imaging (DT-MRI). Three different configurations of RE are compared with a commonly used model of reduced size. The electrical impedance seen by the DBS system and the potential distribution are computed for each model. Moreover, axons are modelled to compute the area of tissue activated by stimulation. Results show that these indicators are influenced by the surface and position of the RE. The use of a RE model corresponding to the implanted device rather than the usually simplified model leads to an increase of the system impedance (+48%) and a reduction of the area of activated tissue (-15%).
Resumo:
Summary Cell therapy has emerged as a strategy for the treatment of various human diseases. Cells can be transplanted considering their morphological and functional properties to restore a tissue damage, as represented by blood transfusion, bone marrow or pancreatic islet cells transplantation. With the advent of the gene therapy, cells also were used as biological supports for the production of therapeutic molecules that can act either locally or at distance. This strategy represents the basis of ex vivo gene therapy characterized by the removal of cells from an organism, their genetic modification and their implantation into the same or another individual in a physiologically suitable location. The tissue or biological function damage dictates the type of cells chosen for implantation and the required function of the implanted cells. The general aim of this work was to develop an ex vivo gene therapy approach for the secretion of erythropoietin (Epo) in patients suffering from Epo-responsive anemia, thus extending to humans, studies previously performed with mouse cells transplanted in mice and rats. Considering the potential clinical application, allogeneic primary human cells were chosen for practical and safety reasons. In contrast to autologous cells, the use of allogeneic cells allows to characterize a cell lineage that can be further transplanted in many individuals. Furthermore allogeneic cells avoid the potential risk of zoonosis encountered with xenogeneic cells. Accordingly, the immune reaction against this allogeneic source was prevented by cell macro- encapsulation that prevents cell-to-cell contact with the host immune system and allows to easy retrieve the implanted device. The first step consisted in testing the survival of various human primary cells that were encapsulated and implanted for one month in the subcutaneous tissue of immunocompetent and naturally or therapeutically immunodepressed mice, assuming that xenogeneic applications constitute a stringent and representative screening before human transplantation. A fibroblast lineage from the foreskin of a young donor, DARC 3.1 cells, showed the highest mean survival score. We have then performed studies to optimize the manufacturing procedures of the encapsulation device for successful engraftment. The development of calcifications on the polyvinyl alcohol (PVA) matrix serving as a scaffold for enclosed cells into the hollow fiber devices was reported after one month in vivo. Various parameters, including matrix rinsing solutions, batches of PVA and cell lineages were assessed for their respective role in the development of the phenomenon. We observed that the calcifications could be totally prevented by using ultra-pure sterile water instead of phosphate buffer saline solution in the rinsing procedure of the PVA matrix. Moreover, a higher lactate dehydrogenase activity of the cells was found to decrease calcium depositions due to more acidic microenvironment, inhibiting the calcium precipitation. After the selection of the appropriate cell lineage and the optimization of encapsulation conditions, a retroviral-based approach was applied to DARC 3.1 fibroblasts for the transduction of the human Epo cDNA. Various modifications of the retroviral vector and the infection conditions were performed to obtain clinically relevant levels of human Epo. The insertion of a post-transcriptional regulatory element from the woodchuck hepatitis virus as well as of a Kozak consensus sequence led to a 7.5-fold increase in transgene expression. Human Epo production was further optimized by increasing the multiplicity of infection and by selecting high producer cells allowing to reach 200 IU hEpo/10E6 cells /day. These modified cells were encapsulated and implanted in vivo in the same conditions as previously described. All the mouse strains showed a sustained increase in their hematocrit and a high proportion of viable cells were observed after retrieval of the capsules. Finally, in the perspective of human application, a syngeneic model using encapsulated murine myoblasts transplanted in mice was realized to investigate the roles of both the host immune response and the cells metabolic requirements. Various loading densities and anti-inflammatory as well as immunosuppressive drugs were studied. The results showed that an immune process is responsible of cell death in capsules loaded at high cell density. A supporting matrix of PVA was shown to limit the cell density and to avoid early metabolic cell death, preventing therefore the immune reaction. This study has led to the development of encapsulated cells of human origin producing clinically relevant amounts of human EPO. This work resulted also to the optimization of cell encapsulation technical parameters allowing to begin a clinical application in end-stage renal failure patients. Résumé La thérapie cellulaire s'est imposée comme une stratégie de traitement potentiel pour diverses maladies. Si l'on considère leur morphologie et leur fonction, les cellules peuvent être transplantées dans le but de remplacer une perte tissulaire comme c'est le cas pour les transfusions sanguines ou les greffes de moelle osseuse ou de cellules pancréatiques. Avec le développement de la thérapie génique, les cellules sont également devenues des supports biologiques pour la production de molécules thérapeutiques. Cette stratégie représente le fondement de la thérapie génique ex vivo, caractérisée par le prélèvement de cellules d'un organisme, leur modification génétique et leur implantation dans le même individu ou dans un autre organisme. Le choix du type de cellule et la fonction qu'elle doit remplir pour un traitement spécifique dépend du tissu ou de la fonction biologique atteintes. Le but général de ce travail est de développer .une approche par thérapie génique ex vivo de sécrétion d'érythropoïétine (Epo) chez des patients souffrant d'anémie, prolongeant ainsi des travaux réalisés avec des cellules murines implantées chez des souris et des rats. Dans cette perpective, notre choix s'est porté sur des cellules humaines primaires allogéniques. En effet, contrairement aux cellules autologues, une caractérisation unique de cellules allogéniques peut déboucher sur de nombreuses applications. Par ailleurs, l'emploi de cellules allogéniques permet d'éviter les riques de zoonose que l'on peut rencontrer avec des cellules xénogéniques. Afin de protéger les cellules allogéniques soumises à une réaction immunitaire, leur confinement dans des macro-capsules cylindriques avant leur implantation permet d'éviter leur contact avec les cellules immunitaires de l'hôte, et de les retrouver sans difficulté en cas d'intolérance ou d'effet secondaire. Dans un premier temps, nous avons évalué la survie de différentes lignées cellulaires humaines primaires, une fois encapsulées et implantées dans le tissu sous-cutané de souris, soit immunocompétentes, soit immunodéprimées naturellement ou par l'intermédiaire d'un immunosuppresseur. Ce modèle in vivo correspond à des conditions xénogéniques et représente par conséquent un environnement de loin plus hostile pour les cellules qu'une transplantation allogénique. Une lignée fibroblastique issue du prépuce d'un jeune enfant, nommée DARC 3 .1, a montré une remarquable résistance avec un score de survie moyen le plus élevé parmi les lignées testées. Par la suite, nous nous sommes intéressés aux paramètres intervenant dans la réalisation du système d'implantation afin d'optimaliser les conditions pour une meilleure adaptation des cellules à ce nouvel environnement. En effet, en raison de l'apparition, après un mois in vivo, de calcifications au niveau de la matrice de polyvinyl alcohol (PVA) servant de support aux cellules encapsulées, différents paramètres ont été étudiés, tels que les procédures de fabrication, les lots de PVA ou encore les lignées cellulaires encapsulées, afin de mettre en évidence leur rôle respectif dans la survenue de ce processus. Nous avons montré que l'apparition des calcifications peut être totalement prévenue par l'utilisation d'eau pure au lieu de tampon phosphaté lors du rinçage des matrices de PVA. De plus, nous avons observe qu'un taux de lactate déshydrogénase cellulaire élevé était corrélé avec une diminution des dépôts de calcium au sein de la matrice en raison d'un micro-environnement plus acide inhibant la précipitation du calcium. Après sélection de la lignée cellulaire appropriée et de l'optimisation des conditions d'encapsulation, une modification génétique des fibroblastes DARC 3.1 a été réalisée par une approche rétrovirale, permettant l'insertion de l'ADN du gène de l'Epo dans le génome cellulaire. Diverses modifications, tant au niveau génétique qu'au niveau des conditions d'infection, ont été entreprises afin d'obtenir des taux de sécrétion d'Epo cliniquement appropriés. L'insertion dans la séquence d'ADN d'un élément de régulation post¬transcriptionnelle dérivé du virus de l'hépatite du rongeur (« woodchuck ») ainsi que d'une séquence consensus appelée « Kozak » ont abouti à une augmentation de sécrétion d'Epo 7.5 fois plus importante. De même, l'optimisation de la multiplicité d'infection et la sélection plus drastique des cellules hautement productrices ont permis finalement d'obtenir une sécrétion correspondant à 200 IU d'Epo/10E6 cells/jour. Ces cellules génétiquement modifiées ont été encapsulées et implantées in vivo dans les mêmes conditions que celles décrites plus haut. Toutes les souris transplantées ont montré une augmentation significative de leur hématocrite et une proportion importante de cellules présentait une survie conservée au moment de l'explantation des capsules. Finalement, dans la perspective d'une application humaine, un modèle syngénique a été proposé, basé sur l'implantation de myoblastes murins encapsulés dans des souris, afin d'investiguer les rôles respectifs de la réponse immunitaire du receveur et des besoins métaboliques cellulaires sur leur survie à long terme. Les cellules ont été encapsulées à différentes densités et les animaux transplantés se sont vus administrer des injections de molécules anti-inflammatoires ou immunosuppressives. Les résultats ont démontré qu'une réaction immunologique péri-capsulaire était à la base du rejet cellulaire dans le cas de capsules à haute densité cellulaire. Une matrice de PVA peut limiter cette densité et éviter une mort cellulaire précoce due à une insuffisance métabolique et par conséquent prévenir la réaction immunitaire. Ce travail a permis le développement de cellules encapsulées d'origine humaine sécrétant des taux d'Epo humaine adaptés à des traitements cliniques. De pair avec l'optimalisation des paramètres d'encapsulation, ces résultats ont abouti à l'initiation d'une application clinique destinée à des patients en insuffisance rénale terminale.
Resumo:
Objetivo: Describir los eventos ocurridos en el seguimiento a largo plazo de pacientes llevados a cierre percutáneo de FOP y CIA con dispositivo Amplatzer® Materiales y métodos: Estudio de seguimiento en donde se seleccionó una cohorte histórica de pacientes llevados a cierre percutáneo del FOP y CIA con dispositivo Amplatzer desde el año 2001 hasta el 2013, De los 92 (100%) pacientes intervenidos, se realizó seguimiento clínico a 55 (60%) pacientes, y 37 (40%) pacientes no se pudieron contactar, se revisaron registros médicos y se realizarón entrevistas telefónicas. Resultados: La edad promedio de los pacientes fue de 58 años, con una mediana de 62 años, el 73% de las intervenciones fueron realizadas en mujeres. Se realizaron 30 (55%) cierres percutáneos de CIA y 25 (45%) cierres de FOP, se presentaron dos complicaciones secundarias al procedimiento 3.6% (reacción alérgica y hematoma hepático), el diámetro del defecto septal fue 15 mm (DE 9),y una mediana de 16 mm, El tamaño del dispositivo implantado fue de 40 mm (DE 3.9 mm) (13 mm y 34 mm). El seguimiento registró un tiempo promedio de 44 meses (DE 28,6), (7-114 meses) con una mediana de 36 meses, no se registraron eventos, la probabilidad de supervivencia de este grupo de pacientes fue del 100% y la probabilidad de muerte fue del 0%.
Resumo:
Objective: To assess the usefulness, compatibility, and long-term operability of a microelectrode array into the median nerve of the left arm of a healthy volunteer, including perception of feedback stimulation and operation of an instrumented prosthetic hand. Setting: The study was carried out from March 14 through June 18, 2002, in England and the United States. Results: The blindfolded subject received feedback information, obtained from force and slip sensors on the prosthetic hand, and subsequently used the implanted device to control the hand by applying an appropriate force to g rip an unseen object. Operability was also demonstrated remotely via the Internet, with the subject in New York, NY, and the prosthetic hand in Reading, England. Finally, the subject was able to control an electric wheelchair, via decoded signals from the implant device, to select the direction of travel by opening and closing his hand. The implantation did not result in infection or any perceivable loss of hand sensation or motion control. The implant was finally extracted because of mechanical fatigue of the percutaneous connection. Further testing after extraction has not indicated any measurable long-term defects in the subject. Conclusions: This implant may allow recipients to have abilities they would otherwise not possess. The response to stimulation improved considerably during the trial, suggesting that the subject learned to process the incoming information more effectively.
Resumo:
This paper describes a CMOS implementation of a linear voltage regulator (LVR) used to power up implanted physiological signal systems, as it is the case of a wireless blood pressure biosensor. The topology is based on a classical structure of a linear low-dropout regulator. The circuit is powered up from an RF link, thus characterizing a passive radio frequency identification (RFID) tag. The LVR was designed to meet important features such as low power consumption and small silicon area, without the need for any external discrete components. The low power operation represents an essential condition to avoid a high-energy RF link, thus minimizing the transmitted power and therefore minimizing the thermal effects on the patient's tissues. The project was implemented in a 0.35-mu m CMOS process, and the prototypes were tested to validate the overall performance. The LVR output is regulated at 1 V and supplies a maximum load current of 0.5 mA at 37 degrees C. The load regulation is 13 mV/mA, and the line regulation is 39 mV/V. The LVR total power consumption is 1.2 mW.
Resumo:
As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
Globally, more than 1000 tonnes of titanium (Ti) is implanted into patients in the form of biomedical devices on an annual basis. Ti is perceived to be ‘biocompatible’ owing to the presence of a robust passive oxide film (approx. 4 nm thick) at the metal surface. However, surface deterioration can lead to the release of Ti ions, and particles can arise as the result of wear and/or corrosion processes. This surface deterioration can result in peri-implant inflammation, leading to the premature loss of the implanted device or the requirement for surgical revision. Soft tissues surrounding commercially pure cranial anchorage devices (bone-anchored hearing aid) were investigated using synchrotron X-ray micro-fluorescence spectroscopy and X-ray absorption near edge structure. Here, we present the first experimental evidence that minimal load-bearing Ti implants, which are not subjected to macroscopic wear processes, can release Ti debris into the surrounding soft tissue. As such debris has been shown to be pro-inflammatory, we propose that such distributions of Ti are likely to effect to the service life of the device.
Resumo:
PURPOSE: Implanted venous access devices (IVADs) are often used in patients who require long-term intravenous drug administration. The most common causes of device dysfunction include occlusion by fibrin sheath and/or catheter adherence to the vessel wall. We present percutaneous endovascular salvage techniques to restore function in occluded catheters. The aim of this study was to evaluate the feasibility, safety, and efficacy of these techniques. METHODS AND MATERIALS: Through a femoral or brachial venous access, a snare is used to remove fibrin sheath around the IVAD catheter tip. If device dysfunction is caused by catheter adherences to the vessel wall, a new "mechanical adhesiolysis" maneuver was performed. IVAD salvage procedures performed between 2005 and 2013 were analyzed. Data included clinical background, catheter tip position, success rate, recurrence, and rate of complication. RESULTS: Eighty-eight salvage procedures were performed in 80 patients, mostly women (52.5 %), with a mean age of 54 years. Only a minority (17.5 %) of evaluated catheters were located at an optimal position (i.e., cavoatrial junction ±1 cm). Mechanical adhesiolysis or other additional maneuvers were used in 21 cases (24 %). Overall technical success rate was 93.2 %. Malposition and/or vessel wall adherences were the main cause of technical failure. No complications were noted. CONCLUSION: These IVAD salvage techniques are safe and efficient. When a catheter is adherent to the vessel wall, mechanical adhesiolysis maneuvers allow catheter mobilization and a greater success rate with no additional risk. In patients who still require long-term use of their IVAD, these procedures can be performed safely to avoid catheter replacement.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
PURPOSE: Totally implanted vascular (TIVA) ports are used in children for repeated blood samples or intravenous treatments. We have recently published a prospective evaluation of surgical incidents and early complications associated with these devices. This work is the final part of the same study, assessing late complications over a follow-up of 2 yrs. METHODS: From January 2006 to January 2008, children older than 1 yr of age with a diagnosis of solid or blood cell malignancy were included. Insertion technique and care of the device were standardized. Every manipulation was prospectively recorded by specialized nurses. Obstruction was documented clinically. When bacteremia was suspected, routine central and peripheral blood cultures were drawn. RESULTS: Forty-five consecutive patients were enrolled in the study. Mean age at the time of the procedure was 8.5 yrs. There was no catheter-related infection within the first 4 weeks post-surgery. No device had to be removed because of infection or obstruction during follow-up. Frequent accesses to the port (=3 per day over a 10-day period) were associated with an 8-fold risk of infection. CONCLUSION: Insertion and use of TIVA devices were frequently associated with complications. No device had to be removed because of infection or obstruction over the follow-up period, although no prophylactic antibiotic agent was used. Restrictive use of antibiotics may prevent opportunistic infection. Frequent access to the device was significantly associated with line infection (odds ratio=8.43). No risk factor was identified for obstruction which occurred at a rate of 5.3 per 10,000 accesses.
Resumo:
OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.
Resumo:
Background: The purpose of this study was to evaluate the effect of the duodenal-jejunal bypass liner (DJBL), a 60-cm, impermeable fluoropolymer liner anchored in the duodenum to create a duodenal-jejunal bypass, on metabolic parameters in obese subjects with type 2 diabetes. Methods: Twenty-two subjects (mean age, 46.2 +/- 10.5 years) with type 2 diabetes and a body mass index between 40 and 60 kg/m(2) (mean body mass index, 44.8 +/- 7.4 kg/m(2)) were enrolled in this 52-week, prospective, open-label clinical trial. Endoscopic device implantation was performed with the patient under general anesthesia, and the subjects were examined periodically during the next 52 weeks. Primary end points included changes in fasting blood glucose and insulin levels and changes in hemoglobin A1c (HbA1c). The DJBL was removed endoscopically at the end of the study. Results: Thirteen subjects completed the 52-week study, and the mean duration of the implant period for all subjects was 41.9 +/- 3.2 weeks. Reasons for early removal of the device included device migration (n = 3), gastrointestinal bleeding (n = 1), abdominal pain (n = 2), principal investigator request (n = 2), and discovery of an unrelated malignancy (n = 1). Using last observation carried forward, statistically significant reductions in fasting blood glucose (-30.3 +/- 10.2 mg/dL), fasting insulin (-7.3 +/- 2.6 mu U/mL), and HbA1c (-2.1 +/- 0.3%) were observed. At the end of the study, 16 of the 22 subjects had an HbA1c < 7% compared with only one of 22 at baseline. Upper abdominal pain (n = 11), back pain (n = 5), nausea (n = 7), and vomiting (n = 7) were the most common device-related adverse events. Conclusions: The DJBL improves glycemic status in obese subjects with diabetes and therefore represents a nonsurgical, reversible alternative to bariatric surgery.
Resumo:
The PediaFlow pediatric ventricular assist device is a miniature magnetically levitated mixed flow pump under development for circulatory support of newborns and infants (3-15 kg) with a targeted flow range of 0.3-1.5 L/min. The first generation design of the PediaFlow (PF1) was manufactured with a weight of approximately 100 g, priming volume less than 2 mL, length of 51 mm, outer diameter of 28 mm, and with 5-mm blood ports. PF1 was evaluated in an in vitro flow loop for 6 h and implanted in ovines for three chronic experiments of 6, 17, and 10 days. In the in vitro test, normalized index of hemolysis was 0.0087 ± 0.0024 g/100L. Hemodynamic performance and blood biocompatibility of PF1 were characterized in vivo by measurements of plasma free hemoglobin, plasma fibrinogen, total plasma protein, and with novel flow cytometric assays to quantify circulating activated ovine platelets. The mean plasma free hemoglobin values for the three chronic studies were 4.6 ± 2.7, 13.3 ± 7.9, and 8.8 ± 3.3 mg/dL, respectively. Platelet activation was low for portions of several studies but consistently rose along with observed animal and pump complications. The PF1 prototype generated promising results in terms of low hemolysis and platelet activation in the absence of complications. Hemodynamic results validated the magnetic bearing design and provided the platform for design iterations to meet the objective of providing circulatory support for young children with exceptional biocompatibility.