273 resultados para IMPLANTABLE DEFIBRILLATOR


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the results of laser-assisted extraction of permanent pacemaker and defibrillator leads. METHODS: We operated upon 36 patients, whose mean age was 54.2 years, and extracted 56 leads. The reasons for extracting the leads were as follows: infection in 19 patients, elective replacement in 13, and other causes in 4 patients. The mean time of catheter placement was 7.5±5.5 years. Forty-seven leads were from pacemakers, and 9 were from defibrillators. Thirty-eight leads were in use, 14 had been abandoned in the pacemaker pocket, and 4 had been abandoned inside the venous system. RESULTS: We successfully extracted 54 catheters, obtaining a 96.4% rate of success and an 82.1% rate for complete extraction. The 2 unsuccessful cases were due to the presence of calcium in the trajectory of the lead. The mean duration of laser light application was 123.0±104.5 s, using 5,215.2±4,924.0 pulses, in a total of 24.4±24.2 cycles of application. Thirty-four leads were extracted from the myocardium with countertraction after complete progression of the laser sheath, 12 leads came loose during the progression of the laser sheath, and the remaining 10 were extracted with other maneuvers. One patient experienced cardiac tamponade after extraction of the defibrillator lead, requiring open emergency surgery. CONCLUSION: The use of the excimer laser allowed extraction of the leads with a 96% rate of success; it was not effective in 2 patients who had calcification on the lead. One patient (2.8%) had a complication that required cardiac surgery on an emergency basis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

QUESTIONS UNDER STUDY: In patients with an implantable defibrillator (ICD), inappropriate ICD interventions alter the quality of life, may cause hospitalisations and limit cost-effectiveness. The aim of the study was to determine the incidence and causes of inappropriate ICD interventions, and to identify patients at risk. METHODS: For this observational longitudinal study, consecutive patients undergoing ICD implantation at the University Hospital of Berne were included in a registry. All stored electrograms of episodes triggering ICD interventions were systematically reviewed and analysed to determine whether ICD interventions were appropriate or inappropriate. Inappropriate ICD interventions were classified according to their cause, and risk factors were sought. RESULTS: 214 consecutive patients were followed during a median time of 2.7 years (3.7 years IQR, 698 patient years). 81 inappropriate ICD interventions occurred in 58 patients (27%). Factors triggering inappropriate ICD interventions included atrial fibrillation and flutter (n = 35, 44%), sinus tachycardia (n = 26, 32%), lead fracture (n = 12), recurrent self-terminating ventricular tachycardia (n = 5), double-counting due to T-wave oversensing (n = 3). The only identifiable risk factor for inappropriate ICD interventions was sustained ventricular tachycardia as index arrhythmia. CONCLUSIONS: An important proportion of ICD patients suffer inappropriate ICD interventions that are most commonly due to supraventricular arrhythmias. Patients with ventricular tachycardia prior to ICD implantation are at higher risk of inappropriate ICD interventions. Interventions aiming at decreasing the risk of inappropriate ICD interventions should be considered in these patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UNLABELLED The automatic implantable defibrillator (AID) is the treatment of choice for primary and secondary prevention of sudden death. At the Instituto Nacional de Cardiología, since October 1996 until January 2002, 25 patients were implanted with 26 AID. There were 23 men (92%) and the mean age of the whole group, was 51.4 years. Twenty-three patients (92%) presented structural heart disease, the most common was ischemic heart disease in 13 patients (52%), with a mean ejection fraction of 37.8%. One patient without structural heart disease had Brugada Syndrome. The most frequent clinical arrhythmia was ventricular tachycardia in 14 patients (56%). The mean follow-up was of 29.3 months during which a total of 30 events of ventricular arrhythmia were treated through AID; six of them were inappropriate due to paroxismal atrial fibrillation; 10 AID patients (34%) have not applied for therapy. Three patients (12%) of the group died due to congestive heart failure refractory to pharmacologic treatment. CONCLUSION The implant of the AID is a safe and effective measure for primary and secondary prevention of sudden death. World-wide experience evidences, that this kind of device has not modified the mortality rate due to heart failure in these patients, but it has diminished sudden arrhythmic death.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Worsening in clinical and cardiac status has been noted after chronic right ventricular pacing, but it is uncertain whether atriobiventricular (BiVP) is preferable to atrio-right ventricular pacing (RVP). Conventional versus Multisite Pacing for BradyArrhythmia Therapy study (COMBAT) sought to compare BiVP versus RVP in patients with symptomatic heart failure (HF) and atrioventricular (AV) block. Methods and Results: COMBAT is a prospective multicenter randomized double blind crossover study. Patients with New York Heart Association functional class (FC) II-IV, left ventricular ejection fraction (LVEF) <40%, and AV block as an indication for pacing were enrolled. All patients underwent biventricular system implantation and then were randomized to receive successively (group A) RVP-BiVP-RVP, or (group B) BiVP-RVP-BiVP. At the end of each 3-month crossover period, patients were evaluated according to Quality of Life (QoL), FC, echocardiographic parameters, 6-Minute Walk Test (6MWT), and peak oxygen consumption (VO(2max)). Sixty patients were enrolled, and the mean follow-up period was 17.5 +/- 10.7 months. There were significant improvements in QoL, FC, LVEF, and left ventricular end-systolic volume with BiVP compared with RVP. The effects of pacing mode on 6MWT and VO(2max) were not significantly different. Death occurred more frequently with RVP. Conclusion: In patients with systolic HF and AV block requiring permanent ventricular pacing, BiVP is superior to RVP and should be considered the preferred pacing mode. (J Cardiac Fail 2010;16:293-300)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Early repolarization is a common electrocardiographic finding that is generally considered to be benign. Its potential to cause cardiac arrhythmias has been hypothesized from experimental studies, but it is not known whether there is a clinical association with sudden cardiac arrest. METHODS: We reviewed data from 206 case subjects at 22 centers who were resuscitated after cardiac arrest due to idiopathic ventricular fibrillation and assessed the prevalence of electrocardiographic early repolarization. The latter was defined as an elevation of the QRS-ST junction of at least 0.1 mV from baseline in the inferior or lateral lead, manifested as QRS slurring or notching. The control group comprised 412 subjects without heart disease who were matched for age, sex, race, and level of physical activity. Follow-up data that included the results of monitoring with an implantable defibrillator were obtained for all case subjects. RESULTS: Early repolarization was more frequent in case subjects with idiopathic ventricular fibrillation than in control subjects (31% vs. 5%, P<0.001). Among case subjects, those with early repolarization were more likely to be male and to have a history of syncope or sudden cardiac arrest during sleep than those without early repolarization. In eight subjects, the origin of ectopy that initiated ventricular arrhythmias was mapped to sites concordant with the localization of repolarization abnormalities. During a mean (+/-SD) follow-up of 61+/-50 months, defibrillator monitoring showed a higher incidence of recurrent ventricular fibrillation in case subjects with a repolarization abnormality than in those without such an abnormality (hazard ratio, 2.1; 95% confidence interval, 1.2 to 3.5; P=0.008). CONCLUSIONS: Among patients with a history of idiopathic ventricular fibrillation, there is an increased prevalence of early repolarization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Equations to predict maximum heart rate (HRmax) in heart failure (HF) patients receiving beta-adrenergic blocking (BB) agents do not consider the cause of HF. We determined equations to predict HRmax in patients with ischemic and nonischemic HF receiving BB therapy. Methods and Results: Using treadmill cardiopulmonary exercise testing, we studied HF patients receiving BB therapy being considered for transplantation from 1999 to 2010. Exclusions were pacemaker and/or implantable defibrillator, left ventricle ejection fraction (LVEF) >50%, peak respiratory exchange ratio (RER) <1.00, and Chagas disease. We used linear regression equations to predict HRmax based on age in ischemic and nonischemic patients. We analyzed 278 patients, aged 47 +/- 10 years, with ischemic (n = 75) and nonischemic (n = 203) HF. LVEF was 30.8 +/- 9.4% and 28.6 +/- 8.2% (P = .04), peak VO2 16.9 +/- 4.7 and 16.9 +/- 5.2 mL kg(-1) min(-1) (P = NS), and the HRmax 130.8 +/- 23.3 and 125.3 +/- 25.3 beats/min (P = .051) in ischemic and nonischemic patients, respectively. We devised the equation HRmax = 168 - 0.76 x age (R-2 = 0.095; P = .007) for ischemic HF patients, but there was no significant relationship between age and HRmax in nonischemic HF patients (R-2 = 0.006; P = NS). Conclusions: Our study suggests that equations to estimate HRmax should consider the cause of HF. (J Cardiac Fail 2012;18:831-836)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As the population ages, recurrent ventricular tachycardia (VT) is increasingly encountered in elderly patients with ischemic heart disease. Radiofrequency catheter ablation is useful for reducing VT therapy in patients with an implantable defibrillator. The utility of radiofrequency catheter ablation in the elderly is not well defined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Many patients with an implantable cardioverter-defibrillator (ICD) have indications for magnetic resonance imaging (MRI). However, MRI is generally contraindicated in ICD patients because of potential risks from hazardous interactions between the MRI and ICD system. OBJECTIVE: The purpose of this study was to use preclinical computer modeling, animal studies, and bench and scanner testing to demonstrate the safety of an ICD system developed for 1.5-T whole-body MRI. METHODS: MRI hazards were assessed and mitigated using multiple approaches: design decisions to increase safety and reliability, modeling and simulation to quantify clinical MRI exposure levels, animal studies to quantify the physiologic effects of MRI exposure, and bench testing to evaluate safety margin. RESULTS: Modeling estimated the incidence of a chronic change in pacing capture threshold >0.5V and 1.0V to be less than 1 in 160,000 and less than 1 in 1,000,000 cases, respectively. Modeling also estimated the incidence of unintended cardiac stimulation to occur in less than 1 in 1,000,000 cases. Animal studies demonstrated no delay in ventricular fibrillation detection and no reduction in ventricular fibrillation amplitude at clinical MRI exposure levels, even with multiple exposures. Bench and scanner testing demonstrated performance and safety against all other MRI-induced hazards. CONCLUSION: A preclinical strategy that includes comprehensive computer modeling, animal studies, and bench and scanner testing predicts that an ICD system developed for the magnetic resonance environment is safe and poses very low risks when exposed to 1.5-T normal operating mode whole-body MRI.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An implantable cardiac defibrillator (ICD) is a cardiac implantable electronic device that is capable of identifying and treating ventricular arrhythmias. Consideration about the type of ICD to select for a given patient include whether the patient has bradycardia requiring pacing support, has associated atrial tachyarrhythmias, or would benefit from cardiac resynchronization therapy. The ICD functions by continuously monitoring the patient's cardiac rate and delivering therapies (anti-tachycardia pacing, shocks) when the rate exceeds the programmed rate "cutoff". Secondary prevention trials have demonstrated that ICDs reduce the incidence of arrhythmic death and total mortality in patients presenting with a cardiac arrest. ICDs are also indicated for primary prevention of sudden cardiac death in specific high-risk subgroups of patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Magnetic resonance imaging (MRI) of patients with conventional implantable cardioverter-defibrillators (ICD) is contraindicated. OBJECTIVES: This multicenter, randomized trial evaluated safety and efficacy of a novel ICD system specially designed for full-body MRI without restrictions on heart rate or pacing dependency. The primary safety objective was >90% freedom from MRI-related events composite endpoint within 30 days post-MRI. The primary efficacy endpoints were ventricular pacing capture threshold and ventricular sensing amplitude. METHODS: Subjects received either a single- or dual-chamber ICD. In a 2:1 randomization, subjects either underwent MRI at 1.5-T of the chest, cervical, and head regions to maximize radiofrequency exposure up to 2 W/kg specific absorption rate and gradient field exposure to 200 T/m/s per axis (MRI group, n = 175), or they underwent a 1-h waiting period without MRI (control group, n = 88). A subset of MRI patients underwent ventricular fibrillation induction testing post-MRI to characterize defibrillation function. RESULTS: In 42 centers, 275 patients were enrolled (76% male, age 60.4 ± 13.8 years). The safety endpoint was met with 100% freedom from the composite endpoint (p < 0.0001). Both efficacy endpoints were met with minimal differences in the proportion of MRI and control patients who demonstrated a ≤0.5 V increase in ventricular pacing capture threshold (100% MRI vs. 98.8% control, noninferiority p < 0.0001) or a ≤50% decrease in R-wave amplitude (99.3% MRI vs. 98.8% control, noninferiority p = 0.0001). A total of 34 ventricular tachyarrhythmia/ventricular fibrillation episodes (20 induced; 14 spontaneous) occurred in 24 subjects post-MRI, with no observed effect on sensing, detection, or treatment. CONCLUSIONS: This is the first randomized clinical study of an ICD system designed for full-body MRI at 1.5-T. These data support that the system is safe and the MRI scan does not adversely affect electrical performance or efficacy. (Confirmatory Clinical Trial of the Evera MRI System for Conditionally-Safe MRI Access; NCT02117414).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT) offers patients with implanted cardioverter defibrillators (ICDs) and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words “anxiety”, “depression”, “implantable cardioverter”, “cognitive behavioral therapy” and “psychotherapy” was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011), and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Assessing the efficacy of implantable cardioverter-defibrillators (ICD) in patients with Chagas' heart disease (ChHD) and identifying the clinical predictors of mortality and ICD shock during long-term follow-up. ChHD is associated with ventricular tachyarrhythmias and an increased risk of sudden cardiac death. Although ChHD is a common form of cardiomyopathy in Latin American ICD users, little is known about its efficacy in the treatment of this population. The study cohort included 116 consecutive patients with ChHD and an ICD implanted for secondary prevention. Of the 116 patients, 83 (72%) were men; the mean age was 54 +/- 10.7 years. Several clinical variables were tested in a multivariate Cox model for predicting long-term mortality. The average follow-up was 45 +/- 32 months. New York Heart Association class I-II developed in 83% of patients. The mean left ventricular ejection fraction was 42 +/- 16% at implantation. Of the 116 patients, 58 (50%) had appropriate shocks and 13 (11%) had inappropriate therapy. A total of 31 patients died (7.1% annual mortality rate). New York Heart Association class III (hazard ratio [HR] 3.09, 95% confidence interval 1.37 to 6.96, p = 0.0064) was a predictor of a worse prognosis. The left ventricular ejection fraction (HR 0.972, 95% confidence interval 0.94 to 0.99, p = 0.0442) and low cumulative right ventricular pacing (HR 0.23, 95% confidence interval 0.11 to 0.49, p = 0.0001) were predictors of better survival. The left ventricular diastolic diameter was an independent predictor of appropriate shock (I-ER 1.032, 95% confidence interval 1.004 to 1.060, p = 0.025). In conclusion, in a long-term follow-up, ICD efficacy for secondary sudden cardiac death prevention in patients with ChHD was marked by a favorable annual rate of all-cause mortality (7.1%); 50% of the cohort received appropriate shock therapy. New York Heart Association class III and left ventricular ejection fraction were independent predictors of worse prognosis, and low cumulative right ventricular pacing defined better survival. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;110:1040-1045)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Patients with an implantable cardioverter defibrillator (ICD) show clinically relevant depression and anxiety, but little is known about their levels of posttraumatic stress. We assessed chronic posttraumatic stress attributable to a traumatic cardiac event and its predictors in patients at two time points after ICD placement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Patients with left ventricular noncompaction (LVNC) have an increased risk for life-threatening ventricular arrhythmias. The benefit from implantable cardioverter-defibrillators (ICD) in these patients has been investigated only in small series. Therefore, the aim of the present study was to analyze the clinical outcome of a larger population of patients with LVNC who were treated with an ICD.