987 resultados para IDA ICE
Resumo:
Besides the sustaining of healthy and comfortable indoor climate, the air conditioning system should also achieve for energy efficiency. The target indoor climate can be ob-tained with different systems; this study focuses on comparing the energy efficiency of different air conditioning room unit systems in different climates. The calculations are made with dynamic energy simulation software IDA ICE by comparing the indoor cli-mate and energy consumption of an office building with different systems in different climates. The aim of the study is to compare the energy efficiency of chilled beam systems to other common systems: variable air volume, fan coil and radiant ceiling systems. Besides the annual energy consumption also the sustainability of target indoor climate is compared between the simulations. Another aim is to provide conclusions to be used in the product development of the chilled beam systems’ energy efficiency. The adaptable chilled beam system and the radiant ceiling system prove to be energy efficient independent of the climate. The challenge of reliable comparison is that other systems are not able to reach the target indoor climate as well as the others. The complex calculation environment of the simulation software, made assumptions and excluding of the financial aspects complicate comparing the big picture. The results show that the development of the chilled beam systems should concentrate on energy efficient night heating, flexible demand based ventilation and capacity control and possibilities on integrating the best practices with other systems.
Resumo:
La presente Tesis Doctoral evalúa la contribución de una fachada activa, constituida por acristalamientos con circulación de agua, en el rendimiento energético del edificio. Con especial énfasis en la baja afección sobre su imagen, su integración ha de favorecer la calificación del edificio con el futuro estándar de Edificio de consumo de Energía Casi Nulo (EECN). El propósito consiste en cuantificar su aportación a limitar la demanda de climatización, como solución de fachada transparente acorde a las normas de la energía del 2020. En el primer capítulo se introduce el planteamiento del problema. En el segundo capítulo se desarrollan la hipótesis y el objetivo fundamental de la investigación. Para tal fin, en el tercer capítulo, se revisa el estado del arte de la tecnología y de la investigación científica, mediante el análisis de la literatura de referencia. Se comparan patentes, prototipos, sistemas comerciales asimilables, investigaciones en curso en Universidades, y proyectos de investigación y desarrollo, sobre envolventes que incorporan acristalamientos con circulación de agua. El método experimental, expuesto en el cuarto capítulo, acomete el diseño, la fabricación y la monitorización de un prototipo expuesto, durante ciclos de ensayos, a las condiciones climáticas de Madrid. Esta fase ha permitido adquirir información precisa sobre el rendimiento del acristalamiento en cada orientación de incidencia solar, en las distintas estaciones del año. En paralelo, se aborda el desarrollo de modelos teóricos que, mediante su asimilación a soluciones multicapa caracterizadas en las herramientas de simulación EnergyPlus y IDA-ICE (IDA Indoor Climate and Energy), reproducen el efecto experimental. En el quinto capítulo se discuten los resultados experimentales y teóricos, y se analiza la respuesta del acristalamiento asociado a un determinado volumen y temperatura del agua. Se calcula la eficiencia en la captación de la radiación y, mediante la comparativa con un acristalamiento convencional, se determina la reducción de las ganancias solares y las pérdidas de energía. Se comparan el rendimiento del acristalamiento, obtenido experimentalmente, con el ofrecido por paneles solares fototérmicos disponibles en el mercado. Mediante la traslación de los resultados experimentales a casos de células de tamaño habitable, se cuantifica la afección del acristalamiento sobre el consumo en refrigeración y calefacción. Diferenciando cada caso por su composición constructiva y orientación, se extraen conclusiones sobre la reducción del gasto en climatización, en condiciones de bienestar. Posteriormente, se evalúa el ahorro de su incorporación en un recinto existente, de construcción ligera, localizado en la Escuela de Arquitectura de la Universidad Politécnica de Madrid (UPM). Mediante el planteamiento de escenarios de rehabilitación energética, se estima su compatibilidad con un sistema de climatización mediante bomba de calor y extracción geotérmica. Se describe el funcionamiento del sistema, desde la perspectiva de la operación conjunta de los acristalamientos activos e intercambio geotérmico, en nuestro clima. Mediante la parametrización de sus funciones, se estima el beneficio adicional de su integración, a partir de la mejora del rendimiento de la bomba de calor COP (Coefficient of Performance) en calefacción, y de la eficiencia EER (Energy Efficiency Ratio) en refrigeración. En el recinto de la ETSAM, se ha analizado la contribución de la fachada activa en su calificación como Edificio de Energía Casi Nula, y estudiado la rentabilidad económica del sistema. En el sexto capítulo se exponen las conclusiones de la investigación. A la fecha, el sistema supone alta inversión inicial, no obstante, genera elevada eficiencia con bajo impacto arquitectónico, reduciéndose los costes operativos, y el dimensionado de los sistemas de producción, de mayor afección sobre el edificio. Mediante la envolvente activa con suministro geotérmico no se condena la superficie de cubierta, no se ocupa volumen útil por la presencia de equipos emisores, y no se reduce la superficie o altura útil a base de reforzar los aislamientos. Tras su discusión, se considera una alternativa de valor en procesos de diseño y construcción de Edificios de Energía Casi Nulo. Se proponen líneas de futuras investigación cuyo propósito sea el conocimiento de la tecnología de los acristalamientos activos. En el último capítulo se presentan las actividades de difusión de la investigación. Adicionalmente se ha proporcionado una mejora tecnológica a las fachadas activas existentes, que ha derivado en la solicitud de una patente, actualmente en tramitación. ABSTRACT This Thesis evaluates the contribution of an active water flow glazing façade on the energy performance of buildings. Special emphasis is made on the low visual impact on its image, and the active glazing implementation has to encourage the qualification of the building with the future standard of Nearly Zero Energy Building (nZEB). The purpose is to quantify the façade system contribution to limit air conditioning demand, resulting in a transparent façade solution according to the 2020 energy legislation. An initial approach to the problem is presented in first chapter. The second chapter develops the hypothesis and the main objective of the research. To achieve this purpose, the third chapter reviews the state of the art of the technology and scientific research, through the analysis of reference literature. Patents, prototypes, assimilable commercial systems, ongoing research in other universities, and finally research and development projects incorporating active fluid flow glazing are compared. The experimental method, presented in fourth chapter, undertakes the design, manufacture and monitoring of a water flow glazing prototype exposed during test cycles to weather conditions in Madrid. This phase allowed the acquisition of accurate information on the performance of water flow glazing on each orientation of solar incidence, during different seasons. In parallel, the development of theoretical models is addressed which, through the assimilation to multilayer solutions characterized in the simulation tools EnergyPlus and IDA-Indoor Climate and Energy, reproduce the experimental effect. Fifth chapter discusses experimental and theoretical results focused to the analysis of the active glazing behavior, associated with a specific volume and water flow temperature. The efficiency on harvesting incident solar radiation is calculated, and, by comparison with a conventional glazing, the reduction of solar gains and energy losses are determined. The experimental performance of fluid flow glazing against the one offered by photothermal solar panels available on the market are compared. By translating the experimental and theoretical results to cases of full-size cells, the reduction in cooling and heating consumption achieved by active fluid glazing is quantified. The reduction of energy costs to achieve comfort conditions is calculated, differentiating each case by its whole construction composition and orientation. Subsequently, the saving of the implementation of the system on an existing lightweight construction enclosure, located in the School of Architecture at the Polytechnic University of Madrid (UPM), is then calculated. The compatibility between the active fluid flow glazing and a heat pump with geothermal heat supply system is estimated through the approach of different energy renovation scenarios. The overall system operation is described, from the perspective of active glazing and geothermal heat exchange combined operation, in our climate. By parameterization of its functions, the added benefit of its integration it is discussed, particularly from the improvement of the heat pump performance COP (Coefficient of Performance) in heating and efficiency EER (Energy Efficiency Ratio) in cooling. In the case study of the enclosure in the School of Architecture, the contribution of the active glazing façade in qualifying the enclosure as nearly Zero Energy Building has been analyzed, and the feasibility and profitability of the system are studied. The sixth chapter sets the conclusions of the investigation. To date, the system may require high initial investment; however, high efficiency with low architectural impact is generated. Operational costs are highly reduced as well as the size and complexity of the energy production systems, which normally have huge visual impact on buildings. By the active façade with geothermal supply, the deck area it is not condemned. Useful volume is not consumed by the presence of air-conditioning equipment. Useful surface and room height are not reduced by insulation reinforcement. After discussion, water flow glazing is considered a potential value alternative in nZEB design and construction processes. Finally, this chapter proposes future research lines aiming to increase the knowledge of active water flow glazing technology. The last chapter presents research dissemination activities. Additionally, a technological improvement to existing active facades has been developed, which has resulted in a patent application, currently in handling process.
Resumo:
Methods: We conducted a randomized controlled trial at the Amparo Maternal Birth Center in Sao Paulo, Brazil. Study participants included 114 nulliparous women divided into 3 groups (n = 38 per group): experimental (ice packs on the perineum), placebo (water packs at set temperature), and control (no treatment). Results: A numerical scale (0 to 10) was used for pain assessment. A comparison of the average pain at the beginning and after 20 minutes showed a significant reduction of pain (P < .001) in the 3 groups, and the experimental group had a lower average score for pain compared with the control group (1.6 versus 3.3, P = .032). Discussion: The use of ice packs for 20 minutes was effective for perineal pain relief after vaginal birth.
Resumo:
When a coherent light beam is scattered from a colloidal medium, in the observation plane, appears a random grainy image known as speckle pattern. The time evolution of this interference image carries information about the ensemble-averaged dynamics of the scatterer particles. The aim of this work was to evaluate the use of dynamic speckles as an alternative tool to monitoring frozen foams formulated with glucose and fructose syrups. Ice creams, after preparation and packing, were stored at 18 degrees C. Changes in properties of products were analyzed by speckle phenomena at three room temperatures (20 degrees C, 25 degrees C and 30 degrees C), minute by minute, during 50 min. Two moments were identified in which samples activity achieved significant levels. These instants were associated, respectively, to ice crystals melting and to air bubbles dissipation into the food matrix causing motion of diverse structures. As expected, ice crystals melting was first in formulations containing fructose syrup, but for same samples, air losses were delayed. Speckle methodology was satisfactory to observe temporal evolution of transient process, opening goods prospects to application, still incoming, in foodstuffs researches. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Between 34 and 15 million years (Myr) ago, when planetary temperatures were 3-4 degreesC warmer than at present and atmospheric CO2 concentrations were twice as high as today(1), the Antarctic ice sheets may have been unstable(2-7). Oxygen isotope records from deep-sea sediment cores suggest that during this time fluctuations in global temperatures and high-latitude continental ice volumes were influenced by orbital cycles(8-10). But it has hitherto not been possible to calibrate the inferred changes in ice volume with direct evidence for oscillations of the Antarctic ice sheets(11). Here we present sediment data from shallow marine cores in the western Ross Sea that exhibit well dated cyclic variations, and which link the extent of the East Antarctic ice sheet directly to orbital cycles during the Oligocene/Miocene transition (24.1-23.7 Myr ago). Three rapidly deposited glaci-marine sequences are constrained to a period of less than 450 kyr by our age model, suggesting that orbital influences at the frequencies of obliquity (40 kyr) and eccentricity (125 kyr) controlled the oscillations of the ice margin at that time. An erosional hiatus covering 250 kyr provides direct evidence for a major episode of global cooling and ice-sheet expansion about 23.7 Myr ago, which had previously been inferred from oxygen isotope data (Mil event(5)).
Resumo:
The purpose of this study was to analyze the development of four 20 year-old elite hockey players through an in-depth examination of their sporting activities. The theoretical framework of deliberate practice (Ericsson, Krampe, & Tesch-Römer, 1993) and the notion of deliberate play (Côté, 1999) served as the theoretical foundations. Interviews were conducted to provide a longitudinal and detailed account of each participant's involvement in various sporting activities. The interviewer asked questions about the conditions and sporting activities for each year of development. The data obtained were validated through independent interviews conducted with three parents of three different athletes. The results were consistent with Côté's (1999) three stages of development in sport: the sampling (age 6-12), specializing (age 13-15), and investment (age 16+) years.
Resumo:
Uma vez que o meu percurso profissional no Teatro tem sido desenvolvido enquanto actriz, considerei que a apresentação de um trabalho de natureza profissional para o requerimento do título de especialista nesta área deveria incidir sobre a Interpretação em Teatro. O espectáculo escolhido como exemplificativo do meu percurso remonta a 2009 – Otelo de William Shakespeare. A primeira parte da presente comunicação pretende dar conta do processo de trabalho seguido pela encenação de Kuniaki Ida no Teatro do Bolhão, e cuja equipa integrei como intérprete no papel de Emília. Nela se dão conta das várias etapas – do trabalho de mesa ao levantamento das cenas – que conduziram ao espectáculo apresentado primeiramente no Porto (ACE) e depois no Teatro da Trindade, Teatro Municipal de Vila Real e Casa das Artes de Famalicão. A segunda parte é dedicada a uma reflexão sobre o trabalho do actor, processos e dúvidas evidenciadas por este espectáculo em particular. Apesar de o tempo para a reflexão e o debate sobre processos ser muito escasso durante a preparação de um espectáculo, não há trabalho que não despolete um questionamento no actor sobre o melhor modo de aproximação à criação da personagem. Salvaguardamos aqui o facto de estarmos a tratar da criação num contexto logocêntrico, criação de um espectáculo a partir de um texto dramático que inclui intriga, acção e personagens, e não outro tipo de abordagem teatral que suprime os princípios da dramaturgia clássica.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
The case studies the potential partnership between a small family business, rich in tradition, that sells ice cream in the Lisbon area and a recognized Portuguese family who runs a multinational business. The aim of this study is to address students to analyze the evolution of the small company by using the Agency and Resource-Based Theories and to outline a potentially successful co-ownership structure if the agreement were to take place. The particularity of the case regards considering and identifying the main Family Business issues to keep in mind when dealing with these types of firms.
Resumo:
PURPOSE: In this study, the authors compared the cardiorespiratory responses between the 30-15 Intermittent Ice Test (30-15(IIT)) and the 30-15 Intermittent Fitness Test (30-15(IFT)) in semiprofessional hockey players. METHODS: Ten players (age 24 ± 6 y) from a Swiss League B team performed the 30-15(IIT) and 30-15(IFT) in random order (13 ± 4 d between trials). Cardiorespiratory variables were measured with a portable gas analyzer. Ventilatory threshold (VT), respiratory-compensation point (RCP), and maximal speeds were measured for both tests. Peak blood lactate ([La(peak)]) was measured at 1 min postexercise. RESULTS: Compared with 30-15(IFT), 30-15(IIT) peak heart rate (HR(peak); mean ± SD 185 ± 7 vs 189 ± 10 beats/min, P = .02) and peak oxygen consumption (VO(2peak)); 60 ± 7 vs 62.7 ± 4 mL/min/kg, P = .02) were lower, whereas [La(peak)] was higher (10.9 ± 1 vs 8.6 ± 2 mmol/L, P < .01) for the 30-15(IIT). VT and RCP values during the 30-15(IIT) and 30-15(IFT) were similar for %HR(peak) (76.3% ± 5% vs 75.5% ± 3%, P = .53, and 90.6% ± 3% vs. 89.8% ± 3%, P = .45) and % VO(2peak) (62.3% ± 5% vs 64.2% ± 6%, P = .46, and 85.9% ± 5% vs 84.0% ± 7%, P = .33). VO(2peak ))(r = .93, P < .001), HR(peak) (r = .86, P = .001), and final velocities (r = .69, P = .029) were all largely to almost perfectly correlated. CONCLUSIONS: Despite slightly lower maximal cardiorespiratory responses than in the field-running version of the test, the on-ice 30-15(IIT) is of practical interest since it is a specific maximal test with a higher anaerobic component.