991 resultados para Hybrid controller


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a hybrid controller based on the combination of fuzzy logic control (FLC) mechanism and internal model-based control (IMC). Neural network-based inverse and forward models are developed for IMC. After designing the FLC and IMC independently, they are combined in parallel to produce a single control signal. Mean averaging mechanism is used to combine the prediction of both controllers. Finally, performance of the proposed hybrid controller is studied for a nonlinear numerical plant model (NNPM). Simulation result shows the proposed hybrid controller outperforms both FLC and IMC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Direct-drive linear reciprocating compressors offer numerous advantages over conventional counterparts which are usually driven by a rotary induction motor via crank shaft However, to ensure efficient and reliable operation under all conditions, it is essential that the motor current of the linear compressor follows a sinusoidal command profile with a frequency which matches the system resonant frequency. This paper describes a hybrid current controller for the linear compressors. It comprises a conventional proportional-integral (PI) controller, and a B-spline neural network compensator which is trained on-line and in real-time in order to minimize the current tracking error under all conditions with uncertain disturbances. It has been shown that the hybrid current controller has a superior steady-state and transient performance over the conventional carrier based PI controller. The performance of the proposed hybrid controller has been demonstrated by extensive simulations and experiments. It has also been shown that the linear compressor operates stably under the current feedback control and the piston stroke can be adjusted by varying the amplitude of the current command. © 2007 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A neuro-fuzzy system consists of two or more control techniques in only one structure. The main characteristic of this structure is joining one or more good aspects from each technique to make a hybrid controller. This controller can be based in Fuzzy systems, artificial Neural Networks, Genetics Algorithms or rein forced learning techniques. Neuro-fuzzy systems have been shown as a promising technique in industrial applications. Two models of neuro-fuzzy systems were developed, an ANFIS model and a NEFCON model. Both models were applied to control a ball and beam system and they had their results and needed changes commented. Choose of inputs to controllers and the algorithms used to learning, among other information about the hybrid systems, were commented. The results show the changes in structure after learning and the conditions to use each one controller based on theirs characteristics

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O conceito de controle híbrido é aplicado à operação de alívio entre um FPWSO e um navio aliviador. Ambos os navios mantêm suas posições e aproamentos pelo resultado da ação do seu Sistema de Posicionamento Dinâmico (SPD). O alívio dura cerca de 24 horas para ser concluído. Durante este período, o estado de mar pode se alterar e os calados estão sendo constantemente alterados. Um controlador híbrido é projetado para permitir modificacões dos parâmetros de controle/observação se alguma alteração significante do estado de mar e/ou calado das embarcações ocorrer. O principal objetivo dos controladores é manter o posicionamento relativo entre os navios com o intuito de evitar perigosa proximidade ou excesso de tensão no cabo. Com isto em mente, uma nova estratégia de controle que atue integradamente em ambos os navios é proposta baseda em geometria diferencial. Observadores não lineares baseados em passividade são aplicados para estimar a posição, a velocidade e as forças externas de mares calmos até extremos. O critério para troca do controle/observação é baseado na variação do calado e no estado de mar. O calado é assumido conhecido e o estado de mar é estimado pela frequência de pico do espectro do movimento de primeira ordem dos navios. Um modelo de perturbação é proposto para encontrar o número de controladores do sistema híbrido. A equivalência entre o controle geométrico e o controlador baseado em Multiplicadores de Lagrange é demonstrada. Assumindo algumas hipóteses, a equivalência entre os controladores geométrico e o PD é também apresentada. O desempenho da nova estratégia é avaliada por meio de simulações numéricas e comparada a um controlador PD. Os resultados apresentam muito bom desempenho em função do objetivo proposto. A comparação entre a abordagem geométrica e o controlador PD aponta um desempenho muito parecido entre eles.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper compares the performance of two droop control schemes in a hybrid microgrid. With presence of both converter interfaced and inertial sources, the droop controller share power in a decentralized fashion. Both the droop controllers facilitate reactive power sharing based on voltage droop. However in frequency droop control, the real power sharing depends on the frequency, while in angle droop control, it depends on output voltage angle. For converter interfaced sources this reference voltage is tracked while for inertial DG, reference power for the prime mover is calculated from the reference angle with the proposed angle control scheme. This coordinated control scheme shows significant improvement in system performance. The comparison with the conventional frequency droop shows that the angle control scheme shares power with much lower frequency deviation. This is a significant improvement particularly in a frequent load changing scenario.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper introduces Periodically Controlled Hybrid Automata (PCHA) for describing a class of hybrid control systems. In a PCHA, control actions occur roughly periodically while internal and input actions may occur in the interim changing the discrete-state or the setpoint. Based on periodicity and subtangential conditions, a new sufficient condition for verifying invariance of PCHAs is presented. This technique is used in verifying safety of the planner-controller subsystem of an autonomous ground vehicle, and in deriving geometric properties of planner generated paths that can be followed safely by the controller under environmental uncertainties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper focuses on a parallel hybrid electric vehicle. It first develops a model for the vehicle using the backward-looking approach where the flow of energy starts from wheels and spreads towards engine and electric motor. Next, a fuzzy logic-based strategy is developed to control the operation of the vehicle. The objectives of the controller include managing the energy flow from engine and electric motor, controlling transmission ratio, adjusting speed, and sustaining battery's state of charge. The controller examines current vehicle speed, demand torque, slope difference, state of charge of battery, and engine and electric motor rotation speeds. Then, it determines the best values for continuous variable transmission ratio, speed, and torque. A slope window scheme is also developed to take into account the look-ahead slope information and determine the best vehicle speed for better fuel economy. The developed model and control strategy are simulated. The simulation results are presented and discussed. It is shown that the use of the proposed fuzzy controller reduces fuel consumption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

stract This paper proposes a hybrid discontinuous control methodology for a voltage source converter (VSC), which is used in an uninterrupted power supply (UPS) application. The UPS controls the voltage at the point of common coupling (PCC). An LC filter is connected at the output of the VSC to bypass switching harmonics. With the help of both filter inductor current and filter capacitor voltage control, the voltage across the filter capacitor is controlled. Based on the voltage error, the control is switched between current and voltage control modes. In this scheme, an extra diode state is used that makes the VSC output current discontinuous. This diode state reduces the switching losses. The UPS controls the active power it supplies to a three-phase, four-wire distribution system. This gives a full flexibility to the grid to buy power from the UPS system depending on its cost and load requirement at any given time. The scheme is validated through simulation using PSCAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Permanent magnet (PM) motors utilising ironless stator structures have been incorporated into a wide variety of applications where high efficiency and stringent torque control are required. With recent developments in magnetic materials, improved design strategies, and power outputs of up to 40kW, PM motors have become an attractive candidate for traction drives in electric and hybrid electric vehicles. However, due to their large air gaps and ironless stators these motors can have inductances as low as 2μH, imposing increased requirements on the converter to minimise current ripple. Multilevel converters with n cells can effectively increase the motor inductance by a factor of n2 and are an excellent approach to minimise the motor ripple current. Furthermore by indirectly coupling the outputs of each cell, improvements in converter input and cell ripple current can also be realised. This paper examines the issues in designing a high current indirectly coupled multilevel motor controller for an ironless BLDC traction drive and highlights the limitations of the common ladder core structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Displacement of conventional synchronous generators by non-inertial units such as wind or solar generators will result in reduced-system inertia affecting under-frequency response. Frequency control is important to avoid equipment damage, load shedding, and possible blackouts. Wind generators along with energy storage systems can be used to improve the frequency response of low-inertia power system. This paper proposes a fuzzy-logic based frequency controller (FFC) for wind farms augmented with energy storage systems (wind-storage system) to improve the primary frequency response in future low-inertia hybrid power system. The proposed controller provides bidirectional real power injection using system frequency deviations and rate of change of frequency (RoCoF). Moreover, FFC ensures optimal use of energy from wind farms and storage units by eliminating the inflexible de-loading of wind energy and minimizing the required storage capacity. The efficacy of the proposed FFC is verified on the low-inertia hybrid power system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a framework for developing and reasoning about hybrid systems that are comprised of a plant with multiple controllers, each of which controls the plant intermittently. The framework is based on the notion of a ``conflict tolerant'' specification for a controller, and provides a modular way of developing and reasoning about such systems. We propose a novel mechanism of defining conflict-tolerant specifications for general hybrid systems, using ``acceptor'' and ``advisor'' components. We also give a decision procedure for verifying whether a controller satisfies its conflict-tolerant specification, in the special case when the components are modeled using initialized rectangular hybrid automata.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the application of hybrid model predictive control to control switching between different burner modes in a novel compact marine boiler design. A further purpose of the present work is to point out problems with finite horizon model predictive control applied to systems for which the optimal solution is a limit cycle. Regarding the marine boiler control the aim is to find an optimal control strategy which minimizes a trade-off between deviations in boiler pressure and water level from their respective setpoints while limiting burner switches.The approach taken is based on the Mixed Logic Dynamical framework. The whole boiler systems is modelled in this framework and a model predictive controller is designed. However to facilitate on-line implementation only a small part of the search tree in the mixed integer optimization is evaluated to find out whether a switch should occur or not. The strategy is verified on a simulation model of the compact marine boiler for control of low/high burner load switches. It is shown that even though performance is adequate for some disturbance levels it becomes deteriorated when the optimal solution is a limit cycle. Copyright © 2007 International Federation of Automatic Control All Rights Reserved.