910 resultados para Humidity Profiles
Resumo:
A spectrally resolved discrete-ordinates radiative transfer model is used to calculate the change in downwelling surface and top-of-the-atmosphere (TOA) outgoing longwave (3.9-500 mum) radiative fluxes induced by tropospheric aerosols of the type observed over the Indian Ocean during the Indian Ocean Experiment (INDOEX). Both external and internal aerosol mixtures were considered. Throughout the longwave, the aerosol volume extinction depends more strongly on relative humidity than in most of the shortwave (0.28-3.9 mum), implying that particle growth factors and realistic relative humidity profiles must be taken into account when modeling the longwave radiative effects of aerosols. A typical boundary layer aerosol loading, with a 500-nm optical depth of 0.3, will increase the downwelling longwave flux at the surface by 7.7 W m(-2) over the clean air case while decreasing the outgoing longwave radiation by 1.3 W m(-2). A more vertically extended aerosol loading, exhibiting a high opacity plume between 2 and 3 km above the surface and having a typical 500-nm optical depth of 0.7, will increase the downwelling longwave flux at the surface by 11.2 W m(-2) over the clean air case while decreasing the outgoing longwave radiation by 2.7 W m(-2). For a vertically extended aerosol profile, approximately 30% of the TOA radiative forcing comes from sea salt and approximately 60% of the forcing comes from the combination of sea salt and dust. The remaining forcing is from anthropogenic constituents. These results are for the external mixture. For an internal mixture, TOA longwave forcings can be up to a factor of two larger. Therefore, to complete our understanding of this region's longwave aerosol radiative properties, more detailed information is needed about aerosol mixing states. These longwave radiative effects partially offset the large shortwave aerosol radiative forcing and should be included in regional and global climate modeling simulations.
Resumo:
Owing to the lack of atmospheric vertical profile data with sufficient accuracy and vertical resolution, the response of the deep atmosphere to passage of monsoon systems over the Bay of Bengal. had not been satisfactorily elucidated. Under the Indian Climate Research Programme, a special observational programme called 'Bay of Bengal Monsoon Experiment' (BOBMEX), was conducted during July-August 1999. The present study is based on the high-resolution radiosondes launched during BOBMEX in the north Bay. Clear changes in the vertical thermal structure of the atmosphere between active and weak phases of convection have been observed. The atmosphere cooled below 6 km height and became warmer between 6 and 13 km height. The warmest layer was located between 8 and 10 km height, and the coldest layer was found just below 5 km height. The largest fluctuations in the humidity field occurred in the mid-troposphere. The observed changes between active and weak phases of convection are compared with the results from an atmospheric general circulation model, which is similar to that used at the National Centre for Medium Range Weather Forecasting, New Delhi. The model is not able to capture realistically some important features of the temperature and humidity profiles in the lower troposphere and in the boundary layer during the active and weak spells.
Resumo:
This paper considers the relationship between the mean temperature and humidity profiles and the fluxes of heat and moisture at cloud base and the base of the inversion in the cumulus-capped boundary layer. The relationships derived are based on an approximate form of the scalar-flux budget and the scaling properties of the turbulent kinetic energy (TKE) budget. The scalar-flux budget gives a relationship between the change in the virtual potential temperature across either the cloud base transition zone or the inversion and the flux at the base of the layer. The scaling properties of the TKE budget lead to a relationship between the heat and moisture fluxes and the mean subsaturation through the liquid-water flux. The 'jump relation' for the virtual potential temperature at cloud base shows the close connection between the cumulus mass flux in the cumulus-capped boundary layer and the entrainment velocity in the dry-convective boundary layer. Gravity waves are shown to be an important feature of the inversion.
Resumo:
Usando um conjunto de dados para um período de 26 anos (1982 a 2007), este trabalho apresentou um estudo diagnóstico sobre a estrutura vertical da temperatura do ar, temperatura do ponto de orvalho e umidade relativa sobre a região de Belém-PA, durante o mês de novembro. As análises foram conduzidas para duas composições contrastantes no que se refere ao regime de precipitação: a composição dos anos chuvosos e a composição dos anos secos, as quais foram estabelecidas objetivamente pelo método dos percentis. Os resultados apresentados permitiram concluir que a principal diferença observada nos perfis de temperatura e umidade atmosférica, comparando-se os perfis dos anos chuvosos e secos, ocorre na camada atmosférica entre os médios e altos níveis da troposfera (entre os níveis padrões de 700 hPa e 400 hPa). Nesta camada, a diferença entre as temperaturas do ar e do ponto de orvalho é significativamente maior e o contraste de umidade associado à convecção também apresenta os maiores valores. Em geral, as composições demonstraram que os perfis de temperatura anomalamente mais quente (frio) e os de umidade anomalamente mais úmido (seco) associam-se aos anos com registro de chuva acima (abaixo) do normal na região de Belém.
Resumo:
Radiosonde measurements obtained at the Arctic site Ny-Ålesund (78.9° N, 11.9° E), Svalbard, from 1993 to 2014 have been homogenized accounting for instrumentation discontinuities by correcting known errors in the manufacturer provided profiles. From the homogenized data record, the first Ny-Ålesund upper-air climatology of wind, temperature and humidity is presented, forming the background for the analysis of changes during the 22-year period. Particularly during the winter season, a strong increase in atmospheric temperature and humidity is observed, with a significant warming of the free troposphere in January and February up to 3 K per decade. This winter warming is even more pronounced in the boundary layer below 1 km, presumably amplified by mesoscale processes including e.g. orographic effects or the boundary layer capping inversion. Though the largest contribution to the increasing atmospheric water vapour column in winter originates from the lowermost 2 km, no increase in the contribution by specific humidity inversions is detected. Instead, we find an increase in the humidity content of the large scale background humidity profiles. At the same time, the tropospheric flow in winter is found to occur less frequent from northerly directions and to the same amount more frequent from the South. We conclude that changes in the atmospheric circulation lead to an enhanced advection of warm and moist air from lower latitudes to the Svalbard region in the winter season, causing the warming and moistening of the atmospheric column above Ny-Ålesund.
Resumo:
A steady state mathematical model for co-current spray drying was developed for sugar-rich foods with the application of the glass transition temperature concept. Maltodextrin-sucrose solution was used as a sugar-rich food model. The model included mass, heat and momentum balances for a single droplet drying as well as temperature and humidity profile of the drying medium. A log-normal volume distribution of the droplets was generated at the exit of the rotary atomizer. This generation created a certain number of bins to form a system of non-linear first-order differential equations as a function of the axial distance of the drying chamber. The model was used to calculate the changes of droplet diameter, density, temperature, moisture content and velocity in association with the change of air properties along the axial distance. The difference between the outlet air temperature and the glass transition temperature of the final products (AT) was considered as an indicator of stickiness of the particles in spray drying process. The calculated and experimental AT values were close, indicating successful validation of the model. (c) 2004 Elsevier Ltd. All rights reserved.
Resumo:
The literature pertaining to the key stages of spray drying has been reviewed in the context of the mathematical modelling of drier performance. A critical review is also presented of previous spray drying models. A new mathematical model has been developed for prediction of spray drier performance. This is applicable to slurries of rigid, porous crust-forming materials to predict trajectories and drying profiles for droplets with a distribution of sizes sprayed from a centrifugal pressure nozzle. The model has been validated by comparing model predictions to experimental data from a pilot-scale counter-current drier and from a full-scale co-current drier. For the latter, the computed product moisture content was within 2%, and the computed air exit temperature within 10oC of experimental data. Air flow patterns have been investigated in a 1.2m diameter transparent countercurrent spray tower by flow visualisation. Smoke was introduced into various zones within the tower to trace the direction, and gauge the intensity, of the air flow. By means of a set of variable-angle air inlet nozzles, a variety of air entry configurations was investigated. The existence of a core of high rotational and axial velocity channelling up the axis of the tower was confirmed. The stability of flow within the core was found to be strongly dependent upon the air entry arrangement. A probe was developed for the measurement of air temperature and humidity profiles. This was employed for studying evaporation of pure water drops in a 1.2m diameter pilot-scale counter-current drier. A rapid approach to the exit air properties was detected within a 1m distance from the air entry ports. Measured radial profiles were found to be virtually flat but, from the axial profiles, the existence of plug-flow, well-mixed-flow and some degree of air short-circuiting can be inferred. The model and conclusions should assist in the improved design and optimum operation of industrial spray driers.