999 resultados para Human molars
Resumo:
To establish safety parameters, we in vitro studied the increase in intrapulpal temperature caused by the use of a cw CO2 laser. A thermistor was implanted in the inner part of the pulpal chamber of 25 human lower third molars to measure the intrapulpal temperature produced by laser powers between 2-10 W and exposure times of 0.5-25.0 s. The Pearson linear correlation factor applied to the measured values showed there is a direct relationship between the independent variable and the applied power. A variance analysis produced the linear regression equation: T=1.10+(0.127)E where T is the temperature and E the energy. The results showed that, with a power of 4 W and maximum exposure time of 2.5 s (10 J) and a power density of 12738.85 W cm-2, there will be no damaging reactions affecting the pulpal tissues.
Resumo:
Enamel pearls are ectopic structures observed mainly on the roots of permanent teeth and could be related to periodontal diseases. Aim: To evaluate the prevalence of enamel pearls in extracted human molars and characterize their structures using light and scanning electron microscopy. Methods: The study comprised 2,201 extracted human permanent molars. The teeth were analyzed and classified according to morphological features. The presence, location and shape of enamel pearls were investigated. Fifteen human molars with enamel pearls were embedded in acrylic resin and observed by light microscopy. Results: Seventy-one enamel pearls were identified on third molar root. Microscopically, most pearls were composed of prismatic irregular enamel and normal dentin. The dentinoenamel junction presented an irregular course. The number of dentinal tubules was normal and they presented curvature to continue within the root dentin of the carrier tooth. Dentinal tubules below the enamel pearls were closer to each other. Conclusions: Scanning electron microscopic analysis revealed that the enamel pearls were similar to coronal enamel.
Resumo:
Class II cavities were prepared in extracted lower molars filled and cured in three 2-mm increments using a metal matrix. Three composites (Spectrum TPH A4, Ceram X mono M7 and Tetric Ceram A4) were cured with both the SmartLite PS LED LCU and the Spectrum 800 continuous cure halogen LCU using curing cycles of 10, 20 and 40 seconds. Each increment was cured before adding the next. After a seven-day incubation period, the composite specimens were removed from the teeth, embedded in self-curing resin and ground to half the orofacial width. Knoop microhardness was determined 100, 200, 500, 1000, 1500, 2500, 3500, 4500 and 5500 microm from the occlusal surface at a distance of 150 microm and 1000 microm from the metal matrix. The total degree of polymerization of a composite specimen for any given curing time and curing light was determined by calculating the area under the hardness curve. Hardness values 150 microm from the metal matrix never reached maximum values and were generally lower than those 1000 microm from the matrix. The hardest composite was usually encountered between 200 microm and 1000 microm from the occlusal surface. For every composite-curing time combination, there was an increase in microhardness at the top of each increment (measurements at 500, 2500 and 4500 microm) and a decrease towards the bottom of each increment (measurements at 1500, 3500 and 5500 microm). Longer curing times were usually combined with harder composite samples. Spectrum TPH composite was the only composite showing a satisfactory degree of polymerization for all three curing times and both LCUs. Multiple linear regression showed that only the curing time (p < 0.001) and composite material (p < 0.001) had a significant association with the degree of polymerization. The degree of polymerization achieved by the LED LCU was not significantly different from that achieved by the halogen LCU (p = 0.54).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: In vitro analysis of caries resistance of dental enamel under caries simulation after irradiation with Er:YAG laser. Background Data: More susceptible to caries development spots at adjacent hard tissues from cavity preparations of dental tissues using burrs or lasers are quite common. Methods: Thirteen caries-free third permanent human molars were distributed as follows: G1: sound control and caries control; G2: Er:YAG 100, 200, 300, or 400 mJ/ 10 Hz/ 3 sec.; G3: the same parameters of G2 followed by artificial caries simulation, through dynamic model of demineralization and remineralization (DE/RE). Caries resistance analysis was evaluated through scanning electron microscopy (SEM) and Ca/P rate (X-Rays spectroscopy - EDX). Results: Photomicrographs showed that the Er:YAG laser created craters with rough aspect which became more evident as the energy per pulse was increased, but without change of regular morphology of enamel prisms. Significant statistical changes among the irradiated and control groups was observed considering the Ca/P ratio. Conclusion: Irradiated groups showed higher caries resistance than control groups. However, it is not possible to affirm that the enamel surface accidental irradiation could be a benefit to caries resistance for other situations can be considered, as biofilm deposit, which could increase the caries susceptibility.
Resumo:
This study evaluated the pulp chamber penetration of peroxide bleaching agent in human and bovine teeth after office bleach technique. All the teeth were sectioned 3 mm apical of the cement-enamel junction and were divided into 2 groups, A (70 third human molars) and B (70 bovine lateral incisors), that were subdivided into A1 and B1 restored by using composite resin, A2 and B2 by using glass ionomer cement, and A3 and B3 by using resin-modified glass ionomer cement; A4, A5, B4, and B5 were not restored. Acetate buffer was placed in the pulp chamber, and the bleaching agent was applied for 40 minutes as follows: A1-A4 and B1-B4, 38% hydrogen peroxide exposure and A5 and B5, immersion into distilled water. The buffer solution was transferred to a glass tube in which leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to analysis of variance and Dunnett, Kruskal-Wallis, and Tukey tests (5%). A higher level of hydrogen peroxide penetrated into the pulp chamber in resin-modified glass ionomer cements in bovine (0.79 +/- 0.61 mu g) and human (2.27 +/- 0.41 mu g) groups. The bleaching agent penetration into the pulp chamber was higher in human teeth for any experimental situation. The penetration of the hydrogen peroxide depends on restorative materials, and under the conditions of this study human teeth are more susceptible to penetration of bleaching agent into the pulp chamber than bovine teeth.
Resumo:
A cross-sectional microhardness (CSMH) test was carried out in human dental enamel exposed to a demineralizing solution in order to evaluate two different times of indentation in sound tissue and artificially induced caries. Twenty caries-free extracted human molars had one of their smooth surfaces sectioned and the enamel surface was isolated with nail polish except for an area of 6 mm2. These specimens were submitted to artificially induced enamel caries on a lactate buffer containing 0.1 ppm fluoride (F) during 28 days. All specimens were bisected to create groups A and B in which CSMH test was performed employing a Knoop indenter with a 25g load for 5 or 10 s, respectively. Student's paired t-test (p<0.05) was used to determine statistically significant differences between group A and B in 7 depths. There were no significant differences between any of the analyzed depths. Since the present experiment showed no significant difference when comparing indentations made with a 25 g load during either 5 or 10 s in different depths, this method can be used with either one of the time intervals tested without compromising a CSMH test on artificially demineralized human enamel.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: A morphological and ultra-structural study of copper vapor laser (λ = 510.6 nm) effects on enamel and dentine was performed to show the effects of this radiation. Methods: A total of 15 human molars were cut in half; 15 pieces were separated for irradiation on enamel and 15 for dentine. These two groups were further divided into five experimental groups, including a control group, comprised of three half-sections each, irradiated by a CVL laser with a power of 7 W, a repetition rate of 15,000 pulses/sec and exposed at 500, 600, and 800 msec and 1 sec irradiation times with a 5-sec interval between irradiations. Results: In an ultra-structural SEM exam, we observed that on the enamel surfaces irradiated for 1 sec there was morphological alteration that consisted of catering, flaking, and melting on the surfaces. There was no alteration for the other exposure times. On the dentine teeth irradiated for 1 sec, we observed an evident ultra-structural alteration of melted tissue and loss of morphological characteristics. In the dentine group irradiated by 800 msec, we observed ablation and a partial loss of morphological characteristics. In the dentine groups irradiated by 500 and 600 msec, no alteration was observed. Conclusions: The results showed that irradiation with CVL promoted morphologic changes in the enamel as well as in the dentine and demonstrated a need for future studies in order to establish a safe protocol for further use in the odontological practice.
Resumo:
The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (μTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For μTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and μTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the μTBS values.
Resumo:
The aim of this in vitro study was to compare the performance of two laser fluorescence devices (LF, LFpen), conventional visual criteria (VE), ICDAS and radiographic examination on occlusal surfaces of primary teeth. Thirty-seven primary human molars were selected from a pool of extracted teeth, which were stored frozen at -20°C until use. Teeth were assessed twice by two experienced examiners using laser fluorescence devices (LF and LFpen), conventional visual criteria, ICDAS and bitewing radiographs, with a 2-week interval between measurements. After measurement, the teeth were histologically prepared and assessed for caries extension. The highest sensitivity was observed for ICDAS at D(1) and D(3) thresholds, with no statistically significant difference when compared to the LF devices, except at the D(3) threshold. Bitewing radiographs presented the lowest values of sensitivity. Specificity at D(1) was higher for LFpen (0.90) and for VE at D(3) (0.94). When VE was combined with LFpen the post-test probabilities were the highest (94.0% and 89.2% at D(1) and D(3) thresholds, respectively). High values were observed for the combination of ICDAS and LFpen (92.0% and 80.0%, respectively). LF and LFpen showed the highest values of ICC for interexaminer reproducibility. However, regarding ICDAS, BW and VE, intraexaminer reproducibility was not the same for the two examiners. After primary visual inspection using ICDAS or not, the use of LFpen may aid in the detection of occlusal caries in primary teeth. Bitewing radiographs may be indicated only for approximal caries detection.
Resumo:
The aim of this study was to compare the performance of the DIAGNOdent 2095 with visual examination for occlusal caries detection in permanent and primary molars. The sample comprised 148 permanent human molars and 179 primary human molars. The samples were measured and visually examined three times by two examiners. After measurement, the teeth were histologically prepared and assessed for caries extension. Sensitivity, specificity, accuracy and area under the receiver operating characteristics (ROC) curve were calculated. Intra-class correlation (ICC), unweighted kappa and the Bland and Altman method were used to assess inter- and intra-examiner reproducibility. DIAGNOdent showed higher specificity and lower sensitivity than did visual examination. The ICC values indicated an excellent agreement between the examinations. Kappa values varied from good to excellent for DIAGNOdent but from poor to good for visual examination. In conclusion, the DIAGNOdent may be a useful adjunct to conventional methods for occlusal caries detection.
Resumo:
O objetivo deste trabalho foi avaliar o efeito do selamento dentinário imediato na cimentação definitiva de restaurações cerâmicas (Empress2Ivoclar Vivadent), levando em consideração a influência de diferentes métodos de remoção dos restos de cimento provisório da superfície dentinária previamente selada. Para isso foram utilizados 72 molares, hígidos, conseguidos no banco de dentes da Universidade do Estado do Rio de Janeiro. Os dentes foram divididos em nove grupos, os três primeiros serviram como grupo controle, onde não houve contaminação com nenhum cimento provisório, sendo eles: G1, onde o selamento e a cimentação definitiva foram feitas 15 dias após a confecção dos preparos cavitários; G2, onde o selamento dentinário foi feito imediatamente após o preparo e a cimentação definitiva após 15 dias; G3, onde o preparo, selamento e cimentação definitiva foram feitos no mesmo momento. Os próximos grupos foram os do selamento tardio, onde o sistema adesivo foi aplicado somente no momento da cimentação. Nestes grupos, após o preparo foram cimentadas restaurações provisórias com um cimento livre de eugenol (Temp BondNE) e após 15 dias as restaurações provisórias foram removidas e os restos de cimento limpos com diferentes métodos: G4: remoção com instrumento manual; G5: remoção com jato de bicarbonato; G6: remoção com pontas de ultra-som; após esta limpeza o sistema adesivo foi aplicado e as restaurações cerâmicas cimentadas. Por último foram os grupos do selamento dentinário imediato, onde o sistema adesivo foi aplicado imediatamente após a confecção dos preparos cavitários e em seguida foi feita a cimentação das restaurações provisórias. Após 15 dias as restaurações provisórias foram removidas, os restos de cimento foram limpos com os diferentes métodos: G7: remoção com instrumento manual; G8: remoção com jato de bicarbonato; G9: remoção com pontas de ultra-som. Após a limpeza as restaurações cerâmicas foram cimentadas. Para todos os grupos o sistema adesivo utilizado foi o Optibond FL Kerr e o cimento resinoso foi o Rely X ARC3M/ESPE. Vinte e quatro horas após as cimentações cerâmicas os corpos de prova foram submetidos ao ensaio mecânico de push out em uma máquina de ensaios universais EMIC DL. Os valores de resistência de união foram obtidos em KgF, convertidos em MPa e analisados estatisticamente. O teste de ANOVA mostrou que houve diferença estatisticamente significante entre os grupos (p≤0,05) e em seguida o t-teste mostrou que a técnica do selamento imediato resultou nos melhores valores de resistência de união. Por último, o teste de comparações múltiplas Student-Newman-Keuls (Teste SNK) mostrou que o método de limpeza dos restos de cimento provisório da superfície dentinária apresenta influência na resistência de união das restaurações cerâmicas. Com base nos resultados pôde-se concluir que a técnica do selamento imediato promoveu maior resistência adesiva para as restaurações cerâmicas e quanto ao método de limpeza, o melhor resultado, independente da técnica adesiva utilizada, foi a remoção com as pontas de ultrasson.