833 resultados para Housing Thermal Performance Simulation
Resumo:
The new Brazilian ABNT NBR 15575 Standard (the ―Standard‖) recommends two methods for analyzing housing thermal performance: a simplified and a computational simulation method. The aim of this paper is to evaluate both methods and the coherence between each. For this, the thermal performance of a low-cost single-family house was evaluated through the application of the procedures prescribed by the Standard. To accomplish this study, the EnergyPlus software was selected. Comparative analyses of the house with varying envelope U-values and solar absorptance of external walls were performed in order to evaluate the influence of these parameters on the results. The results have shown limitations in the current Standard computational simulation method, due to different aspects: weather files, lack of consideration of passive strategies, and inconsistency with the simplified method. Therefore, this research indicates that there are some aspects to be improved in this Standard, so it could better represent the real thermal performance of social housing in Brazil.
Resumo:
This paper presents results obtained from a numerical simulation for the horizontal slinky-loop heat exchanger of a ground-source heat pump system. A three-dimensional numerical model was developed and the results of the thermal performance of various heat exchanger configurations are presented. The investigation was carried out on five types of loop pitch (loop spacing), three types of loop diameter, three values of soil thermal properties, and allowing continuous and intermittent operation. Comparison was made for the heat transfer rate, the amount of pipe material needed, as well as excavation work required for the horizontal slinky-loop heat exchanger. The results indicate that system parameters have a significant effect on the thermal performance of the system
Resumo:
El propósito de esta tesis es estudiar la aproximación a los fenómenos de transporte térmico en edificación acristalada a través de sus réplicas a escala. La tarea central de esta tesis es, por lo tanto, la comparación del comportamiento térmico de modelos a escala con el correspondiente comportamiento térmico del prototipo a escala real. Los datos principales de comparación entre modelo y prototipo serán las temperaturas. En el primer capítulo del Estado del Arte de esta tesis se hará un recorrido histórico por los usos de los modelos a escala desde la antigüedad hasta nuestro días. Dentro de éste, en el Estado de la Técnica, se expondrán los beneficios que tiene su empleo y las dificultades que conllevan. A continuación, en el Estado de la Investigación de los modelos a escala, se analizarán artículos científicos y tesis. Precisamente, nos centraremos en aquellos modelos a escala que son funcionales. Los modelos a escala funcionales son modelos a escala que replican, además, una o algunas de las funciones de sus prototipos. Los modelos a escala pueden estar distorsionados o no. Los modelos a escala distorsionados son aquellos con cambios intencionados en las dimensiones o en las características constructivas para la obtención de una respuesta específica por ejemplo, replicar el comportamiento térmico. Los modelos a escala sin distorsión, o no distorsionados, son aquellos que mantienen, en la medida de lo posible, las proporciones dimensionales y características constructivas de sus prototipos de referencia. Estos modelos a escala funcionales y no distorsionados son especialmente útiles para los arquitectos ya que permiten a la vez ser empleados como elementos funcionales de análisis y como elementos de toma de decisiones en el diseño constructivo. A pesar de su versatilidad, en general, se observará que se han utilizado muy poco estos modelos a escala funcionales sin distorsión para el estudio del comportamiento térmico de la edificación. Posteriormente, se expondrán las teorías para el análisis de los datos térmicos recogidos de los modelos a escala y su aplicabilidad a los correspondientes prototipos a escala real. Se explicarán los experimentos llevados a cabo, tanto en laboratorio como a intemperie. Se han realizado experimentos con modelos sencillos cúbicos a diferentes escalas y sometidos a las mismas condiciones ambientales. De estos modelos sencillos hemos dado el salto a un modelo reducido de una edificación acristalada relativamente sencilla. Los experimentos consisten en ensayos simultáneos a intemperie del prototipo a escala real y su modelo reducido del Taller de Prototipos de la Escuela Técnica Superior de Arquitectura de Madrid (ETSAM). Para el análisis de los datos experimentales hemos aplicado las teorías conocidas, tanto comparaciones directas como el empleo del análisis dimensional. Finalmente, las simulaciones nos permiten comparaciones flexibles con los datos experimentales, por ese motivo, hemos utilizado tanto programas comerciales como un algoritmo de simulación desarrollado ad hoc para esta investigación. Finalmente, exponemos la discusión y las conclusiones de esta investigación. Abstract The purpose of this thesis is to study the approximation to phenomena of heat transfer in glazed buildings through their scale replicas. The central task of this thesis is, therefore, the comparison of the thermal performance of scale models without distortion with the corresponding thermal performance of their full-scale prototypes. Indoor air temperatures of the scale model and the corresponding prototype are the data to be compared. In the first chapter on the State of the Art, it will be shown a broad vision, consisting of a historic review of uses of scale models, from antiquity to our days. In the section State of the Technique, the benefits and difficulties associated with their implementation are presented. Additionally, in the section State of the Research, current scientific papers and theses on scale models are reviewed. Specifically, we focus on functional scale models. Functional scale models are scale models that replicate, additionally, one or some of the functions of their corresponding prototypes. Scale models can be distorted or not. Scale models with distortion are considered scale models with intentional changes, on one hand, in dimensions scaled unevenly and, on the other hand, in constructive characteristics or materials, in order to get a specific performance for instance, a specific thermal performance. Consequently, scale models without distortion, or undistorted scale models scaled evenly, are those replicating, to the extent possible, without distortion, the dimensional proportions and constructive configurations of their prototypes of reference. These undistorted and functional scale models are especially useful for architects because they can be used, simultaneously, as functional elements of analysis and as decision-making elements during the design. Although they are versatile, in general, it is remarkable that these types of models are used very little for the study of the thermal performance of buildings. Subsequently, the theories related to the analysis of the experimental thermal data collected from the scale models and their applicability to the corresponding full-scale prototypes, will be explained. Thereafter, the experiments in laboratory and at outdoor conditions are detailed. Firstly, experiments carried out with simple cube models at different scales are explained. The prototype larger in size and the corresponding undistorted scale model have been subjected to same environmental conditions in every experimental test. Secondly, a step forward is taken carrying out some simultaneous experimental tests of an undistorted scale model, replica of a relatively simple lightweight and glazed building construction. This experiment consists of monitoring the undistorted scale model of the prototype workshop located in the School of Architecture (ETSAM) of the Technical University of Madrid (UPM). For the analysis of experimental data, known related theories and resources are applied, such as, direct comparisons, statistical analyses, Dimensional Analysis and last, but not least important, simulations. Simulations allow us, specifically, flexible comparisons with experimental data. Here, apart the use of the simulation software EnergyPlus, a simulation algorithm is developed ad hoc for this research. Finally, the discussion and conclusions of this research are exposed.
Resumo:
Roofing provides the main protection against direct solar radiation in animal housing. Appropriate thermal properties of roofing materials tend to improve the thermal comfort in the inner ambient. Nonasbestos fiber-cement roofing components reinforced with cellulose pulp from sisal (Agave sisalana) were produced by slurry and dewatering techniques, with an optional addition of polypropylene fibers. Nonasbestos tiles were evaluated and compared with commercially available asbestos-cement sheets and ceramic tiles (frequently chosen as roofing materials for animal housing). Thermal conductivity and thermal diffusivity of tiles were determined by the parallel hot-wire method, along with the evaluation of the downside surface temperature. Cement-based components reinforced with sisal pulp presented better thermal performance at room temperature (25ºC), while those reinforced with sisal pulp added by polypropylene fibers presented better thermal performance at 60ºC. Non-asbestos cement tiles provided more efficient protection against radiation than asbestos corrugated sheets.
Resumo:
The study on the thermal performance of the air-conditioned buildings of the new research centre of the Brazilian Petroleum Company, in the tropical climate of Rio de Janeiro, was part of a bigger research and consultancy, project involving environmental issues. The architectural design was the subject of a national competition in 2004, encompassing over 100,000 m(2). According to the design brief, out of the 10 buildings of the new research centre, 7 have to be either completely or partially air-conditioned, due to specific occupation requirements. The challenge for better thermal performance was related to systems` energy efficiency, to the introduction of natural ventilation and to the notion of adaptive comfort, which were verified with the support of thermal dynamic simulations. At the early stages of the assessments, the potential for natural ventilation in the working spaces considering the mixed-mode strategy achieved 30% of occupation hours. However, the development of the design project led to fully air-conditioned working spaces, due to users` references regarding the conventional culture of the office environment. Nevertheless, the overall architectural approach in accordance to the climatic conditions still showed a contribution to the buildings` energy efficiency. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The thermal performance of a horizontal-coupled ground-source heat pump system has been assessed both experimentally and numerically in a UK climate. A numerical simulation of thermal behaviour of the horizontal-coupled heat exchanger for combinations of different ambient air temperatures, wind speeds, refrigerant temperature and soil thermal properties was studied using a validated 2D transient model. The specific heat extraction by the heat exchanger increased with ambient temperature and soil thermal conductivity, however it decreased with increasing refrigerant temperature. The effect of wind speed was negligible.
Comparing the thermal performance of horizontal slinky-loop and vertical slinky-loop heat exchangers
Resumo:
The heat pump market in the UK has grown rapidly over the last few years. Performance analyses of vertical ground-loop heat exchanger configurations have been widely carried out using both numerical modelling and experiments. However, research findings and design recommendations on horizontal slinky-loop and vertical slinky-loop heat exchangers are far fewer compared with those for vertical ground-loop heat exchanger configurations, especially where the long-term operation of the systems is concerned. The paper presents the results obtained from a numerical simulation for the horizontal slinky-loop and vertical slinky-loop heat exchangers of a ground-source heat pump system. A three-dimensional numerical heat transfer model was developed to study the thermal performance of various heat exchanger configurations. The influence of the loop pitch (loop spacing) and the depth of a vertical slinky-loop installation were investigated and the thermal performance and excavation work required for the horizontal and vertical slinky-loop heat exchangers were compared. The influence of the installation depth for vertical slinky-loop configurations was also investigated. The results of this study show that the influence of the installation depth of the vertical slinky-loop heat exchanger on the thermal performance of the system is small. The maximum difference in the thermal performance between the vertical and horizontal slinky-loop heat exchangers with the same loop diameter and loop pitch is less than 5%.
Resumo:
Recent studies have shown that the optical properties of building exterior surfaces are important in terms of energy use and thermal comfort. While the majority of the studies are related to exterior surfaces, the radiation properties of interior surfaces are less thoroughly investigated. Development in the coil-coating industries has now made it possible to allocate different optical properties for both exterior and interior surfaces of steel-clad buildings. The aim of this thesis is to investigate the influence of surface radiation properties with the focus on the thermal emittance of the interior surfaces, the modeling approaches and their consequences in the context of the building energy performance and indoor thermal environment. The study consists of both numerical and experimental investigations. The experimental investigations include parallel field measurements on three similar test cabins with different interior and exterior surface radiation properties in Borlänge, Sweden, and two ice rink arenas with normal and low emissive ceiling in Luleå, Sweden. The numerical methods include comparative simulations by the use of dynamic heat flux models, Building Energy Simulation (BES), Computational Fluid Dynamics (CFD) and a coupled model for BES and CFD. Several parametric studies and thermal performance analyses were carried out in combination with the different numerical methods. The parallel field measurements on the test cabins include the air, surface and radiation temperatures and energy use during passive and active (heating and cooling) measurements. Both measurement and comparative simulation results indicate an improvement in the indoor thermal environment when the interior surfaces have low emittance. In the ice rink arenas, surface and radiation temperature measurements indicate a considerable reduction in the ceiling-to-ice radiation by the use of low emittance surfaces, in agreement with a ceiling-toice radiation model using schematic dynamic heat flux calculations. The measurements in the test cabins indicate that the use of low emittance surfaces can increase the vertical indoor air temperature gradients depending on the time of day and outdoor conditions. This is in agreement with the transient CFD simulations having the boundary condition assigned on the exterior surfaces. The sensitivity analyses have been performed under different outdoor conditions and surface thermal radiation properties. The spatially resolved simulations indicate an increase in the air and surface temperature gradients by the use of low emittance coatings. This can allow for lower air temperature at the occupied zone during the summer. The combined effect of interior and exterior reflective coatings in terms of energy use has been investigated by the use of building energy simulation for different climates and internal heat loads. The results indicate possible energy savings by the smart choice of optical properties on interior and exterior surfaces of the building. Overall, it is concluded that the interior reflective coatings can contribute to building energy savings and improvement of the indoor thermal environment. This can be numerically investigated by the choice of appropriate models with respect to the level of detail and computational load. This thesis includes comparative simulations at different levels of detail.
Resumo:
A new numerical methodology for thermal performance calculation in cross-flow heat exchangers is developed. Effectiveness-number of transfer units (epsilon-NTU) data for several standard and complex flow arrangements are obtained using this methodology. The results are validated through comparison with analytical solutions for one-pass cross-flow heat exchangers with one to four rows and with approximate series solution for an unmixed-unmixed heat exchanger, obtaining in all cases very small errors. New effectiveness data for some complex configurations are provided. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The general aim of this work is to contribute to the energy performance assessment of ventilated façades by the simultaneous use of experimental data and numerical simulations. A significant amount of experimental work was done on different types of ventilated façades with natural ventilation. The measurements were taken on a test building. The external walls of this tower are rainscreen ventilated façades. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to investigate the best summer thermal performance of rainscreen ventilated skin façade a study for different setups of rainscreen walls was made. In particular, influences of ventilation grills, air cavity thickness, skin colour, skin material, orientation of façade were investigated. It is shown that some types of rainscreen ventilated façade typologies are capable of lowering the cooling energy demand of a few percent points.
Resumo:
The purpose of this study is to investigate the thermal performance of cool colored acrylic paints containing infrared reflective pigments in comparison to conventional colored acrylic paints of similar colors (white, brown and yellow) applied on sheets of corrugated fiber cement roofing. Evaluated properties are: color according to ASTM D 2244-89, the UV/VIS/NIR reflectance according to ASTM E 90396, and thermal performance by exposure to infrared radiation emitted from a lamp with the measurement of surface temperatures of the specimens with thermocouples connected to a data logging system. Results demonstrated that the cool colored paint formulations produced significantly higher NIR reflectance than conventional paints of similar colors, and that the surface temperatures were more than 10 degrees C lower than those of conventional paints when exposed to infrared radiation. The study shows that cool paints enhance thermal comfort inside buildings, which can reduce air conditioning costs. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
This paper presents new integrated model for variable-speed wind energy conversion systems, considering a more accurate dynamic of the wind turbine, rotor, generator, power converter and filter. Pulse width modulation by space vector modulation associated with sliding mode is used for controlling the power converters. Also, power factor control is introduced at the output of the power converters. Comprehensive performance simulation studies are carried out with matrix, two-level and multilevel power converter topologies in order to adequately assert the system performance. Conclusions are duly drawn.
Resumo:
High reflective paints (cool paints) are used on flat roofs to reduce heat gains from the incidence of solar radiation and thus improve the thermal comfort and energy efficiency of buildings, especially in summer periods. Given the application potential of these paints on vertical surfaces, a research study has been developed to evaluate the thermal performance of reflective paints on walls under real exposure conditions. Accordingly, different reflective paints have been applied as the final coating of an ETICS type solution, on the facades of a full scale experimental cell built at LNEC campus. For being applied in an ETICS system a paint has to fulfill several requirements, whether aesthetic or functional (such as the adhesion between the coating layers or the durability of the insulation), essential for its efficient performance. Since this construction coating system is subject to a prolonged sun exposure, various problems may arise, such as paint degradation or deterioration of the thermal insulation properties, particularly when dark colors are applied. To evaluate the thermal performance of the chosen paints, the method of non-destructive analysis by Infrared Thermography was used. Thermography allows knowing the temperature distribution of facades by measuring the radiation emitted by their surfaces. To complement the thermographic diagnosis, thermocouples were placed between the insulation and the paint system of the experimental cell. Additional laboratory tests allowed the characterization of the optical properties (reflectance and emittance) of the different reflective paints used in this study. The comparative analysis of the thermal performance of reflective and conventional paints revealed that the reflective paint allows a reduction of the facade surface temperature, reducing the risk of loss of insulating properties of the ETICS system and thus ensuring its longevity and functionality. The color of the paint used affects, naturally, the reflective ability of the surface and may have an important role in energy balance of the building. This paper also showed the potential of infrared thermography in the evaluation of the thermal performance of reflective paints.
Resumo:
This paper reports on a new façade system that uses passive solutions in the search for energy efficiency. The differentials are the versatility and flexibility of the modules, which are important advantages of the system. The thermal performance of Trombe walls and glazings and the daylighting performance of glazing were the key aspects analyzed in the results. Computational simulations were accomplished for the thermal performance of different arrangements of the modules with DesignBuilder software. The glazing daylighting performance was studied by means of Ecotect and Desktop Radiance programs and compared with the transmittance curves of glazings. Occupancy profile and internal gains were fixed according to the Portuguese reality for both studies. The main characteristics considered in this research were the use of two double glazings, four different climates in Portugal and one and two Trombe walls in the façade. The results show an important reduction in the energy consumption with the use of Trombe walls and double self-cleaning glazing in the façade, which also presented better daylighting performance.