799 resultados para Heart catheterisation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies have recognised the importance of pulmonary hypertension (PH) in sickle cell disease (SCD). The aim of this study was to determine the prevalence and prognostic impact of PH and its features in patients with SCD. 80 patients with SCD underwent baseline clinical evaluation, laboratory testing, 6-min walk tests (6MWTs) and echocardiography. Patients with a peak tricuspid regurgitant jet velocity (TRV) of >= 2.5 m.s(-1) were further evaluated through right heart catheterisation (RHC) to assure the diagnosis of PH. Our study evidenced a 40% prevalence of patients with elevated TRV at echocardiography. RHC (performed in 25 out of 32 patients) confirmed PH in 10% (95% CI 3.4-16.5%) of all patients, with a prevalence of post-capillary PH of 6.25% (95% CI 0.95-11.55%) and pre-capillary PH of 3.75% (95% CI -0.4-7.9%). Patients with PH were older, had worse performance in 6MWTs, and more pronounced anaemia, haemolysis and renal dysfunction. Survival was shorter in patients with PH. Our study reinforced the use of echocardiography as a screening tool for PH in SCD and the mandatory role of RHC for proper diagnosis. Our findings confirmed the prognostic significance of PH in SCD as its association to pronounced haemolytic profile.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Knowledge of current trends in nurse-administered procedural sedation and analgesia (PSA) in the cardiac catheterisation laboratory (CCL) may provide important insights into how to improve safety and effectiveness of this practice. Objective To characterise current practice as well as education and competency standards regarding nurse-administered PSA in Australian and New Zealand CCLs. Design A quantitative, cross-sectional, descriptive survey design was used. Methods Data were collected using a web-based questionnaire on practice, educational standards and protocols related to nurse-administered PSA. Descriptive statistics were used to analyse data. Results A sample of 62 nurses, each from a different CCL, completed a questionnaire that focused on PSA practice. Over half of the estimated total number of CCLs in Australia and New Zealand was represented. Nurse-administered PSA was used in 94% (n = 58) of respondents CCLs. All respondents indicated that benzodiazepines, opioids or a combination of both is used for PSA (n = 58). One respondent indicated that propofol was also used. 20% (n = 12) indicated that deep sedation is purposefully induced for defibrillation threshold testing and cardioversion without a second medical practitioner present. Sedation monitoring practices vary considerably between institutions. 31% (n = 18) indicated that comprehensive education about PSA is provided. 45% (n = 26) indicated that nurses who administer PSA should undergo competency assessment. Conclusion By characterising nurse-administered PSA in Australian and New Zealand CCLs, a baseline for future studies has been established. Areas of particular importance to improve include protocols for patient monitoring and comprehensive PSA education for CCL nurses in Australia and New Zealand.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Prognostic classification of congestive heart failure (CHF) is difficult and only possible with the help of additional diagnostic tools. B-type natriuretic peptide (BNP) has been used as a diagnostic and prognostic marker for patients (pts) with CHF. In this study, the clinical value of BNP for stratification and treatment of pts with CHF was evaluated. PATIENTS AND METHODS 33 out-pts with CHF (age 57 +/- 12 years) were included. Left-ventricular (LV) ejection fraction (EF) was 27 +/- 8% (mean +/- SD) and NYHA-class 2.4 +/- 0.7. Following parameters were measured: BNP and sodium from blood samples, exercise performance from 6-minute walking test (6MWT, meters) (n = 18), LV end-diastolic diameter (LVEDD) and LV mass (LVM) from 2D-echocardiography (n = 33), as well as LV end-diastolic pressure (LVEDP, n = 23) and systemic vascular resistance (SVR, n = 20) from heart-catheterisation. Ten pts were hospitalised in the preceding 6 months because of worsening CHF or for optimisation of medical therapy. BNP was measured at the beginning and end of the hospital-stay. Follow-up was for 1 year. RESULTS Pts with a high NYHA-class had a higher BNP (pg/ml) than those with a low NYHA- class: NYHA I 51 +/- 20, II 281 +/- 223, III 562+/-346 and IV 1061 +/- 126 pg/ml (p = 0.002). BNP correlated with LVEDP (r = 0.50, p <0.02), SVR (r =0.49, p <0.03) and inversely with 6MWT (r =-0.60, p <0.009), LVEF (r = -0.49, p <0.004) and sodium (r = -0.36, p = 0.04). In the hospitalised pts, mean BNP (pg/ml) was 881 +/- 695 at admission,and 532 +/- 435 at discharge (n.s.). Decrease in BNPduring hospitalisation paralleled weight-loss and was significantly greater in patients with >1000 pg/ml BNP at admission (n = 5) as compared to the 5 patients with BNP <1000 (p <0.03). Patients with an adverse event during 1-year follow-up had significantly higher BNP both at steady-state (603 +/-359 pg/ml) and at time of decompensation than patients with a favourable outcome (227 +/- 218 pg/ml,p <0.001). CONCLUSIONS BNP correlates well with the clinical severity of CHF (NYHA-class) and is directly related to filling pressure (LVEDP), LV function(LVEF) and exercise performance (6 MWT). Furthermore, BNP has prognostic impact with regard to adverse clinical events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims and objectives To explore issues and challenges associated with nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory from the perspectives of senior nurses. Background Nurses play an important part in managing sedation because the prescription is usually given verbally directly from the cardiologist who is performing the procedure and typically, an anaesthetist is not present. Design A qualitative exploratory design was employed. Methods Semi-structured interviews with 23 nurses from 16 cardiac catheterisation laboratories across four states in Australia and also New Zealand were conducted. Data analysis followed the guide developed by Braun and Clark to identify the main themes. Results Major themes emerged from analysis regarding the lack of access to anaesthetists, the limitations of sedative medications, the barriers to effective patient monitoring and the impact that the increasing complexity of procedures has on patients' sedation requirements. Conclusions The most critical issue identified in this study is that current guidelines, which are meant to apply regardless of the clinical setting, are not practical for the cardiac catheterisation laboratory due to a lack of access to anaesthetists. Furthermore, this study has demonstrated that nurses hold concerns about the legitimacy of their practice in situations when they are required to perform tasks outside of clinical practice guidelines. To address nurses' concerns, it is proposed that new guidelines could be developed, which address the unique circumstances in which sedation is used in the cardiac catheterisation laboratory. Relevance to clinical practice Nurses need to possess advanced knowledge and skills in monitoring for the adverse effects of sedation. Several challenges impact on nurses' ability to monitor patients during procedural sedation and analgesia. Preprocedural patient education about what to expect from sedation is essential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Side effects of the medications used for procedural sedation and analgesia in the cardiac catheterisation laboratory are known to cause impaired respiratory function. Impaired respiratory function poses considerable risk to patient safety as it can lead to inadequate oxygenation. Having knowledge about the conditions that predict impaired respiratory function prior to the procedure would enable nurses to identify at-risk patients and selectively implement intensive respiratory monitoring. This would reduce the possibility of inadequate oxygenation occurring. Aim: To identify pre-procedure risk factors for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory. Design: Retrospective matched case–control. Methods: 21 cases of impaired respiratory function were identified and matched to 113 controls from a consecutive cohort of patients over 18 years of age. Conditional logistic regression was used to identify risk factors for impaired respiratory function. Results: With each additional indicator of acute illness, case patients were nearly two times more likely than their controls to experience impaired respiratory function (OR 1.78; 95% CI 1.19–2.67; p = 0.005). Indicators of acute illness included emergency admission, being transferred from a critical care unit for the procedure or requiring respiratory or haemodynamic support in the lead up to the procedure. Conclusion: Several factors that predict the likelihood of impaired respiratory function were identified. The results from this study could be used to inform prospective studies investigating the effectiveness of interventions for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Nursing in the cardiac catheterisation laboratory (CCL) varies globally in terms of scope and deployment. In the US, all allied staff are cross-trained into all CCL roles. The Australian and New Zealand experience has legislative frameworks that reserves specific functions to nurses. Yet, the nursing role within the CCL is poorly researched and defined. Aim: This study sought to gain deeper understanding of the perceived role of CCL nurses in Australia and New Zealand. Method: A descriptive qualitative study using semi-structured in-depth interviews was used. A cross-sectional sample of 23 senior clinical nurses or nursing managers representing 16 CCLs across Australia and New Zealand was obtained. Data were digitally recorded and transcribed verbatim prior to analysis by three researchers. Results: Five major themes emerged from the data. These themes were: 1. The CCL is a unique environment; 2. CCL nursing is a unique and advanced cardiac nursing discipline; 3. The recruitment attributes for CCL nurses are advanced; 4. Education needs to be standardised; and 5. The evidence to support practice is poor. Discussion: The CCL environment is a dynamic, deeply interdisciplinary setting with CCL nursing seen to be a unique advanced practice role. Yet the time has come for a scope of practice, educational standards, guidelines and competencies was expressed by the participants. Conclusion: Nursing in the CCL is an advanced practice role working within a complex interdisciplinary environment. Further work is required to define the role of CCL nurses together with the evidence-base for their practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Australian and New Zealand College of Anaesthetists’ guidelines for procedural sedation and analgesia (PSA) are intended to apply across all clinical settings. As nurses are frequently responsible for patient care during PSA in the cardiac catheterisation laboratory (CCL), their perspectives can provide insight into the effectiveness of these guidelines within this particular setting. Methods: A cross-sectional sampling design was used to recruit nurses from urban, regional, public and private CCLs across Australia and New Zealand. Semi-structured interviews were conducted, digitally recorded and transcribed. Data were analysed using thematic analysis. Findings: Twenty-three nurses from 16 CCLs across four states in Australia and New Zealand participated. Most held senior positions (managers=14; educators=5) and CCL experience ranged from 4 to 26 years (mean 11). Participants were concerned about the legitimacy of their practice as they administered PSA outside of guideline recommendations and deemed present education and training as deficient. Participants noted also that guideline recommendations were sometimes not adhered to as it was difficult to balance the increasingly complex PSA requirements of their case-mix with limited access to anaesthetists while trying not to delay procedures. Conclusion: Findings suggest that application of current PSA guidelines may be impractical for CCL nurses and, as a consequence, they are often not followed. Participants were concerned about risks to patient safety as they felt education and training was not commensurable with practice requirements. The findings suggest existing guidelines should be reviewed or new guidelines developed which address nursing practice, education and competency standards for PSA in the CCL

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Procedural sedation and analgesia (PSA) administered by nurses in the cardiac catheterisation laboratory (CCL) is unlikely to yield serious complications. However, the safety of this practice is dependent on timely identification and treatment of depressed respiratory function. Aim: Describe respiratory monitoring in the CCL. Methods: Retrospective medical record audit of adult patients who underwent a procedure in the CCLs of one private hospital in Brisbane during May and June 2010. An electronic database was used to identify subjects and an audit tool ensured data collection was standardised. Results: Nurses administered PSA during 172/473 (37%) procedures including coronary angiographies, percutaneous coronary interventions, electrophysiology studies, radiofrequency ablations, cardiac pacemakers, implantable cardioverter defibrillators, temporary pacing leads and peripheral vascular interventions. Oxygen saturations were recorded during 160/172 (23%) procedures, respiration rate was recorded during 17/172 (10%) procedures, use of oxygen supplementation was recorded during 40/172 (23%) procedures and 13/172 (7.5%; 95% CI=3.59–11.41%) patients experienced oxygen desaturation. Conclusion: Although oxygen saturation was routinely documented, nurses did not regularly record respiration observations. It is likely that surgical draping and the requirement to minimise radiation exposure interfered with nurses’ ability to observe respiration. Capnography could overcome these barriers to respiration assessment as its accurate measurement of exhaled carbon dioxide coupled with the easily interpretable waveform output it produces, which displays a breath-by-breath account of ventilation, enables identification of respiratory depression in real-time. Results of this audit emphasise the need to ascertain the clinical benefits associated with using capnography to assess ventilation during PSA in the CCL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To develop clinical practice guidelines for nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory. Background Numerous studies have reported that nurse-administered procedural sedation and analgesia is safe. However, the broad scope of existing guidelines for the administration and monitoring of patients who receive sedation during medical procedures without an anaesthetist presents means there is a lack of specific guidance regarding optimal nursing practices for the unique circumstances in which nurse-administered procedural sedation and analgesia is used in the cardiac catheterisation laboratory. Methods A sequential mixed methods design was utilised. Initial recommendations were produced from three studies conducted by the authors: an integrative review; a qualitative study; and a cross-sectional survey. The recommendations were revised in accordance with responses from a modified Delphi study. The first Delphi round was completed by nine senior cardiac catheterisation laboratory nurses. All but one of the draft recommendations met the pre-determined cut-off point for inclusion. There were a total of 59 responses to the second round. Consensus was reached on all recommendations. Implications for nursing The guidelines that were derived from the Delphi study offer twenty four recommendations within six domains of nursing practice: Pre-procedural assessment; Pre-procedural patient and family education; Pre-procedural patient comfort; Intra-procedural patient comfort; Intra-procedural patient assessment and monitoring; and Post-procedural patient assessment and monitoring. Conclusion These guidelines provide an important foundation towards the delivery of safe, consistent and evidence-based nursing care for the many patients who receive sedation in the cardiac catheterisation laboratory setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As part of the investigations into a surgical incident involving the accidental retention inside a patient's venous system of a guide wire for central venous catheterisation (CVC), the Human Error Assessment and Reduction Technique (HEART) was used to examine the potential for further occurrences. It was found to be time-efficient and to yield plausible probabilities of human error, although its use in healthcare has challenges, suggesting adaptation would be beneficial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Exercise capacity after heart transplantation (HTx) remains limited despite normal left ventricular systolic function of the allograft. Various clinical and haemodynamic parameters are predictive of exercise capacity following HTx. However, the predictive significance of chronotropic competence has not been demonstrated unequivocally despite its immediate relevance for cardiac output. AIMS: This study assesses the predictive value of various clinical and haemodynamic parameters for exercise capacity in HTx recipients with complete chronotropic competence evolving within the first 6 postoperative months. METHODS: 51 patients were enrolled in this exercise study. Patients were included when at least >6 months after HTx and without negative chronotropic medication or factors limiting exercise capacity such as significant transplant vasculopathy or allograft rejection. Clinical parameters were obtained by chart review, haemodynamic parameters from current cardiac catheterisation, and exercise capacity was assessed by treadmill stress testing. A stepwise multiple regression model analysed the proportion of the variance explained by the predictive parameters. RESULTS: The mean age of these 51 HTx recipients was 55.4 +/- 13.2 yrs on inclusion, 42 pts were male and the mean time interval after cardiac transplantation was 5.1 +/- 2.8 yrs. Five independent predictors explained 47.5% of the variance observed for peak exercise capacity (adjusted R2 = 0.475). In detail, heart rate response explained 31.6%, male gender 5.2%, age 4.1%, pulmonary vascular resistance 3.7%, and body-mass index 2.9%. CONCLUSION: Heart rate response is one of the most important predictors of exercise capacity in HTx recipients with complete chronotropic competence and without relevant transplant vasculopathy or acute allograft rejection.