978 resultados para Heart Transplantation


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Prolongation of the safe period of ischemia of the heart is an efficient way to overcome donor organ shortage, as demonstrated in renal and hepatic transplantation. We present the results of a prospective, randomized study comparing preservation with University of Wisconsin solution (UWS) versus St. Thomas' Hospital solution (STS) in clinical heart transplantation. A total of 39 patients were enrolled in the study (n = 20 for UWS and n = 19 for STS). Hemodynamic, electron microscopic, and biochemical evaluation did not reveal any significant differences in postoperative myocardial performance. Only the number of intraoperative defibrillations (0.82 for UWS versus 1.7 for STS) and the rhythm stability after reperfusion (13/20 UWS hearts versus 6/19 STS hearts in sinus rhythm) were significantly different. Heart preservation with UWS and STS appears to be of comparable efficacy at mean ischemic times of less than 4 hours.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The current organ shortage in transplantation medicine stimulates the exploration of new strategies to expand the donor pool including the utilisation of living donors, ABO-incompatible grafts, and xenotransplantation. Preformed natural antibodies (Ab) such as anti-Gal or anti-A/B Ab mediate hyperacute graft rejection and thus represent a major hurdle to the employment of such strategies. In contrast to solid organ transplantation (SOT), ABO blood group incompatibilities are of minor importance in haematopoietic stem cell transplantation (HSCT). Thus, ABO incompatible HSCT may serve as an in vivo model to study carbohydrate antigen (Ag)-mismatched transplantations such as ABO-incompatible SOT or the effect of preformed Ab against Gal in xenotransplantation. This mini-review summarises our clinical and experimental studies performed with the support of the Swiss National Science Foundation program on Implants and Transplants (NFP-46). Part 1 describes data on the clinical outcome of ABO-incompatible HSCT, in particular the incidence of several immunohaematological complications, acute graft-versus-host-disease (GvHD), and the overall survival. Part 2 summarises the measurements of anti-A/B Ab in healthy blood donors and ABO-incompatible HSCT using a novel flow cytometry based method and the potential mechanisms responsible for the loss of anti-A/B Ab observed following minor ABO-incompatible HSCT, ie the occurrence of humoral tolerance. Part 3 analyses the potential of eliminating Gal expression as well as specific complement inhibitors such as dextran sulfate and synthetic tyrosine analogues to protect porcine endothelial cells from xenoreactive Ab-mediated damage in vitro and in a hamster-to-rat heart transplantation model. In conclusion, due to similarities of the immunological hurdles of ABO incompatible transplantations and xenotransplantation, the knowledge obtained from both fields might lead to new strategies to overcome humoral rejection in transplantation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Catheter ablation has evolved as a possible curative treatment modality for supraventricular tachycardias (SVT) in patients with univentricular heart. However, the long-term outcome of ablation procedures is unknown. We evaluated the procedural and long-term outcome of ablative therapy of late postoperative SVT in patients with univentricular heart. METHODS AND RESULTS: Patients with univentricular heart (n=19, 11 male; age, 29+/-9 years) referred for ablation of SVT were studied. Ablation was guided by 3D electroanatomic mapping in all but 2 procedures. A total of 41 SVT were diagnosed as intra-atrial reentrant tachycardia (n=30; cycle length, 310+/-68 ms), typical atrial flutter (n=4; cycle length, 288+/-42 ms), focal atrial tachycardia (n=6; cycle length, 400+/-60 ms), and atrial fibrillation (n=1). Ablation was successful in 73% of intra-atrial reentrant tachycardia, 75% of atrial flutter, and all focal atrial tachycardia and focal atrial fibrillation. During the follow-up period of 53+/-34 months, 2 patients were lost to follow-up, 3 died of heart failure, 2 underwent heart transplantation, and 1 underwent conduit replacement. Of the remaining group, 8 had sinus rhythm and 3 had SVT. CONCLUSIONS: Focal and reentrant mechanisms underlie postoperative SVT in patients with univentricular heart. Successive SVT developing over time may be caused by different mechanisms. Ablative therapy is potentially curative, with a procedural success rate of 78%. In patients who had multiple ablation procedures, the SVT originated from different atrial sites, suggesting that these new SVT were caused by progressive atrial disease. Despite recurrent SVT, sinus rhythm at the end of the follow-up period was achieved in 72%.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The ABO blood group system until recently constituted an insuperable barrier for solid organ transplantation, but cases of heart transplantation in infants and kidney transplantation in adults have been reported, wherein ABO-incompatible grafts have been successful. In 1990, the molecular genetic basis of three major alleles at the ABO locus was elucidated; A and B glycosyltransferases are specified by a variety of functional alleles at this locus. The antibody response to ABH antigens, namely, naturally occurring anti-A/B IgM and IgG isotype agglutinins, are controlled preoperatively by recipient conditioning using plasma exchange, immunoadsorption, and immunosuppressive regimens. We report an O-type patient who accidentally received a B-type cardiac allograft in 1997 who survived for 5 years, dying for an unrelated reason. Over a period of 45 months semiquantitatively we monitored the expression of ABO-type antigens in graft heart vessels using monoclonal antibodies on sections of formalin-fixed, paraffin-embedded biopsies. We observed a progressive change in the antigenic profile of graft endothelial cells from B- to O-type, which was first detected at 1 year posttransplant and most prominent 3 years later, the end of the observation period. No temporal relationship was observed between the transition from B to O expression, the anti-B antibody levels or the immunosuppressive regimen.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A cyclosporine (CsA)-based immunosuppression is associated with an increased incidence of cholelithiasis after heart transplantation. It is not known if tacrolimus (Tac) has comparable biliary side effects in humans. We evaluated the incidence of gallbladder sludge and cholelithiasis under Tac-based immunosuppression by ultrasound examinations in 31 cardiac transplants (25 male, 6 female, mean age: 59 ' 11 years). Data were compared to 57 patients (47 male, 10 female, mean age: 58 ' 11 years) who received CsA-based immunosuppression. 6 patients receiving Tac and 6 patients receiving CsA had already gallstones prior to transplantation so that finally 25 patients of the Tac group and 51 patients of the CsA group could be evaluated. In the Tac group the incidence of biliary sludge was 4% (1 of 25), of gallstones 28% (7 of 25). In comparison, patients receiving CsA developed biliary sludge in also 4% (2 of 51) and gallstones in 25% (13 of 51). Nine of 42 males in the CsA group (21%) and eight of 20 males in the Tac group (40%) developed either gallstones or sludge (n.s). Six of nine females in the CsA group (67%), but none of five females in the Tac group (0%) developed either gallstones or sludge (p = 0.01). In summary, the incidence of biliary disease in patients with Tac is comparable with CsA-based immunosuppression. We recommend regular sonographical examinations to detect biliary diseases as early as possible. In cases of clinically, laboratory and sonographical signs of cholecystitis cholecystectomy is indicated. It seems that towards lithogenicity female patients benefit more from a Tac-based treatment because the occurrence of gallstones is rare.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this study was to assess bone mineral density (BMD) and parameters for bone metabolism in patients with end-stage heart disease awaiting heart transplantation to determine whether these patients are at increased risk of bone disease.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The efficacy of everolimus with reduced cyclosporine in de novo heart transplant patients has been demonstrated convincingly in randomized studies. Moreover, everolimus-based immunosuppression in de novo heart transplant recipients has been shown in two randomized trials to reduce the increase in maximal intimal thickness based on intravascular ultrasound, indicating attenuation of cardiac allograft vasculopathy (CAV). Randomized trials of everolimus in de novo heart transplantation have also consistently shown reduced cytomegalovirus infection versus antimetabolite therapy. In maintenance heart transplantation, conversion from calcineurin inhibitors to everolimus has demonstrated a sustained improvement in renal function. In de novo patients, a renal benefit may only be achieved if there is an adequate reduction in exposure to calcineurin inhibitor therapy. Delayed introduction of everolimus may be appropriate in patients at high risk of wound healing complications, e.g. diabetic patients or patients with ventricular assist device. The current evidence base suggests that the most convincing reasons for use of everolimus from the time of heart transplantation are to slow the progression of CAV and to lower the risk of cytomegalovirus infection. A regimen of everolimus with reduced-exposure calcineurin inhibitor and steroids in de novo heart transplant patients represents a welcome addition to the therapeutic armamentarium.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Chronic heart transplant rejection, i.e. cardiac allograft vasculopathy (CAV) is a major adverse prognostic factor after heart transplantation (HTx). This study tested the hypothesis that the relative myocardial blood volume (rBV) as quantified by myocardial contrast echocardiography accurately detects severe CAV as defined by coronary intravascular ultrasound (IVUS).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND After heart transplantation (HTx), the interindividual pharmacokinetic variability of immunosuppressive drugs represents a major therapeutic challenge due to the narrow therapeutic window between over-immunosuppression causing toxicity and under-immunosuppression leading to graft rejection. Although genetic polymorphisms have been shown to influence pharmacokinetics of immunosuppressants, data in the context of HTx are scarce. We thus assessed the role of genetic variation in CYP3A4, CYP3A5, POR, NR1I2, and ABCB1 acting jointly in immunosuppressive drug pathways in tacrolimus (TAC) and ciclosporin (CSA) dose requirement in HTx recipients. METHODS Associations between 7 functional genetic variants and blood dose-adjusted trough (C0) concentrations of TAC and CSA at 1, 3, 6, and 12 months after HTx were evaluated in cohorts of 52 and 45 patients, respectively. RESULTS Compared with CYP3A5 nonexpressors (*3/*3 genotype), CYP3A5 expressors (*1/*3 or *1/*1 genotype) required around 2.2- to 2.6-fold higher daily TAC doses to reach the targeted C0 concentration at all studied time points (P ≤ 0.003). Additionally, the POR*28 variant carriers showed higher dose-adjusted TAC-C0 concentrations at all time points resulting in significant differences at 3 (P = 0.025) and 6 months (P = 0.047) after HTx. No significant associations were observed between the genetic variants and the CSA dose requirement. CONCLUSIONS The CYP3A5*3 variant has a major influence on the required TAC dose in HTx recipients, whereas the POR*28 may additionally contribute to the observed variability. These results support the importance of genetic markers in TAC dose optimization after HTx.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Many end-stage heart failure patients are not eligible to undergo heart transplantation due to organ shortage, and even those under consideration for transplantation might suffer long waiting periods. A better understanding of the hemodynamic impact of left ventricular assist devices (LVAD) on the cardiovascular system is therefore of great interest. Computational fluid dynamics (CFD) simulations give the opportunity to study the hemodynamics in this patient population using clinical imaging data such as computed tomographic angiography. This article reviews a recent study series involving patients with pulsatile and constant-flow LVAD devices in which CFD simulations were used to qualitatively and quantitatively assess blood flow dynamics in the thoracic aorta, demonstrating its potential to enhance the information available from medical imaging.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Cytomegalovirus (CMV) is associated with an increased risk of cardiac allograft vasculopathy (CAV), the major limiting factor for long-term survival after heart transplantation (HTx). The purpose of this study was to evaluate the impact of CMV infection during long-term follow-up after HTx. METHODS A retrospective, single-centre study analyzed 226 HTx recipients (mean age 45 ± 13 years, 78 % men) who underwent transplantation between January 1988 and December 2000. The incidence and risk factors for CMV infection during the first year after transplantation were studied. Risk factors for CAV were included in an analyses of CAV-free survival within 10 years post-transplant. The effect of CMV infection on the grade of CAV was analyzed. RESULTS Survival to 10 years post-transplant was higher in patients with no CMV infection (69 %) compared with patients with CMV disease (55 %; p = 0.018) or asymptomatic CMV infection (54 %; p = 0.053). CAV-free survival time was higher in patients with no CMV infection (6.7 years; 95 % CI, 6.0-7.4) compared with CMV disease (4.2 years; CI, 3.2-5.2; p < 0.001) or asymptomatic CMV infection (5.4 years; CI, 4.3-6.4; p = 0.013). In univariate analysis, recipient age, donor age, coronary artery disease (CAD), asymptomatic CMV infection and CMV disease were significantly associated with CAV-free survival. In multivariate regression analysis, CMV disease, asymptomatic CMV infection, CAD and donor age remained independent predictors of CAV-free survival at 10 years post-transplant. CONCLUSIONS CAV-free survival was significantly reduced in patients with CMV disease and asymptomatic CMV infection compared to patients without CMV infection. These findings highlight the importance of close monitoring of CMV viral load and appropriate therapeutic strategies for preventing asymptomatic CMV infection.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In a randomized, open-label trial, everolimus was compared to cyclosporine in 115 de novo heart transplant recipients. Patients were assigned within 5 days posttransplant to low-exposure everolimus (3–6 ng/mL) with reduced-exposure cyclosporine (n = 56), or standard-exposure cyclosporine (n = 59), with both mycophenolate mofetil and corticosteroids. In the everolimus group, cyclosporine was withdrawn after 7–11 weeks and everolimus exposure increased (6–10 ng/mL). The primary efficacy end point, measured GFR at 12 months posttransplant, was significantly higher with everolimus versus cyclosporine (mean ± SD: 79.8 ± 17.7 mL/min/1.73 m2 vs. 61.5 ± 19.6 mL/min/1.73 m2; p < 0.001). Coronary intravascular ultrasound showed that the mean increase in maximal intimal thickness was smaller (0.03 mm [95% CI 0.01, 0.05 mm] vs. 0.08 mm [95% CI 0.05, 0.12 mm], p = 0.03), and the incidence of cardiac allograft vasculopathy (CAV) was lower (50.0% vs. 64.6%, p = 0.003), with everolimus versus cyclosporine at month 12. Biopsy-proven acute rejection after weeks 7–11 was more frequent with everolimus (p = 0.03). Left ventricular function was not inferior with everolimus versus cyclosporine. Cytomegalovirus infection was less common with everolimus (5.4% vs. 30.5%, p < 0.001); the incidence of bacterial infection was similar. In conclusion, everolimus-based immunosuppression with early elimination of cyclosporine markedly improved renal function after heart transplantation. Since postoperative safety was not jeopardized and development of CAV was attenuated, this strategy may benefit long-term outcome.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND A single non-invasive gene expression profiling (GEP) test (AlloMap®) is often used to discriminate if a heart transplant recipient is at a low risk of acute cellular rejection at time of testing. In a randomized trial, use of the test (a GEP score from 0-40) has been shown to be non-inferior to a routine endomyocardial biopsy for surveillance after heart transplantation in selected low-risk patients with respect to clinical outcomes. Recently, it was suggested that the within-patient variability of consecutive GEP scores may be used to independently predict future clinical events; however, future studies were recommended. Here we performed an analysis of an independent patient population to determine the prognostic utility of within-patient variability of GEP scores in predicting future clinical events. METHODS We defined the GEP score variability as the standard deviation of four GEP scores collected ≥315 days post-transplantation. Of the 737 patients from the Cardiac Allograft Rejection Gene Expression Observational (CARGO) II trial, 36 were assigned to the composite event group (death, re-transplantation or graft failure ≥315 days post-transplantation and within 3 years of the final GEP test) and 55 were assigned to the control group (non-event patients). In this case-controlled study, the performance of GEP score variability to predict future events was evaluated by the area under the receiver operator characteristics curve (AUC ROC). The negative predictive values (NPV) and positive predictive values (PPV) including 95 % confidence intervals (CI) of GEP score variability were calculated. RESULTS The estimated prevalence of events was 17 %. Events occurred at a median of 391 (inter-quartile range 376) days after the final GEP test. The GEP variability AUC ROC for the prediction of a composite event was 0.72 (95 % CI 0.6-0.8). The NPV for GEP score variability of 0.6 was 97 % (95 % CI 91.4-100.0); the PPV for GEP score variability of 1.5 was 35.4 % (95 % CI 13.5-75.8). CONCLUSION In heart transplant recipients, a GEP score variability may be used to predict the probability that a composite event will occur within 3 years after the last GEP score. TRIAL REGISTRATION Clinicaltrials.gov identifier NCT00761787.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cytomegalovirus (CMV) is a highly complex pathogen which, despite modern prophylactic regimens, continues to affect a high proportion of thoracic organ transplant recipients. The symptomatic manifestations of CMV infection are compounded by adverse indirect effects induced by the multiple immunomodulatory actions of CMV. These include a higher risk of acute rejection, cardiac allograft vasculopathy after heart transplantation, and potentially bronchiolitis obliterans syndrome in lung transplant recipients, with a greater propensity for opportunistic secondary infections. Prophylaxis for CMV using antiviral agents (typically oral valganciclovir or intravenous ganciclovir) is now almost universal, at least in high-risk transplants (D+/R-). Even with extended prophylactic regimens, however, challenges remain. The CMV events can still occur despite antiviral prophylaxis, including late-onset infection or recurrent disease, and patients with ganciclovir-resistant CMV infection or who are intolerant to antiviral therapy require alternative strategies. The CMV immunoglobulin (CMVIG) and antiviral agents have complementary modes of action. High-titer CMVIG preparations provide passive CMV-specific immunity but also exert complex immunomodulatory properties which augment the antiviral effect of antiviral agents and offer the potential to suppress the indirect effects of CMV infection. This supplement discusses the available data concerning the immunological and clinical effects of CMVIG after heart or lung transplantation

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Heart disease is attributed as the highest cause of death in the world. Although this could be alleviated by heart transplantation, there is a chronic shortage of donor hearts and so mechanical solutions are being considered. Currently, many Ventricular Assist Devices (VADs) are being developed worldwide in an effort to increase life expectancy and quality of life for end stage heart failure patients. Current pre-clinical testing methods for VADs involve laboratory testing using Mock Circulation Loops (MCLs), and in vivo testing in animal models. The research and development of highly accurate MCLs is vital to the continuous improvement of VAD performance. The first objective of this study was to develop and validate a mathematical model of a MCL. This model could then be used in the design and construction of a variable compliance chamber to improve the performance of an existing MCL as well as form the basis for a new miniaturised MCL. An extensive review of literature was carried out on MCLs and mathematical modelling of their function. A mathematical model of a MCL was then created in the MATLAB/SIMULINK environment. This model included variable features such as resistance, fluid inertia and volumes (resulting from the pipe lengths and diameters); compliance of Windkessel chambers, atria and ventricles; density of both fluid and compressed air applied to the system; gravitational effects on vertical columns of fluid; and accurately modelled actuators controlling the ventricle contraction. This model was then validated using the physical properties and pressure and flow traces produced from a previously developed MCL. A variable compliance chamber was designed to reproduce parameters determined by the mathematical model. The function of the variability was achieved by controlling the transmural pressure across a diaphragm to alter the compliance of the system. An initial prototype was tested in a previously developed MCL, and a variable level of arterial compliance was successfully produced; however, the complete range of compliance values required for accurate physiological representation was not able to be produced with this initial design. The mathematical model was then used to design a smaller physical mock circulation loop, with the tubing sizes adjusted to produce accurate pressure and flow traces whilst having an appropriate frequency response characteristic. The development of the mathematical model greatly assisted the general design of an in vitro cardiovascular device test rig, while the variable compliance chamber allowed simple and real-time manipulation of MCL compliance to allow accurate transition between a variety of physiological conditions. The newly developed MCL produced an accurate design of a mechanical representation of the human circulatory system for in vitro cardiovascular device testing and education purposes. The continued improvement of VAD test rigs is essential if VAD design is to improve, and hence improve quality of life and life expectancy for heart failure patients.