803 resultados para HYPERSENSITIVITY PNEUMONITIS
Resumo:
Metalworking fluid-associated hypersensitivity pneumonitis (MWF-HP) is a pulmonary disease caused by inhaling microorganisms present in the metalworking fluids used in the industrial sector. Mycobacterium immunogenum is the main etiological agent. Among the clinical, radiological and biological tools used for diagnosis, serological tests are important. The aim of this study was to identify immunogenic proteins in M. immunogenum and to use recombinant antigens for serological diagnosis of MWF-HP. Immunogenic proteins were detected by two-dimensional Western blot and candidate proteins were identified by mass spectrometry. Recombinant antigens were expressed in Escherichia coli and tested by enzyme-linked immunosorbent assay (ELISA) with the sera of 14 subjects with MWF-HP and 12 asymptomatic controls exposed to M. immunogenum. From the 350 spots visualized by two-dimensional gel electrophoresis with M. immunogenum extract, 6 immunogenic proteins were selected to be expressed as recombinant antigens. Acyl-CoA dehydrogenase antigen allowed for the best discrimination of MWF-HP cases against controls with an area under the receiver operating characteristics (ROC) curve of 0.930 (95% CI=0.820-1), a sensitivity of 100% and a specificity of 83% for the optimum threshold. Other recombinant antigens correspond to acyl-CoA dehydrogenase FadE, cytosol aminopeptidase, dihydrolipoyl dehydrogenase, serine hydroxymethyltransferase and superoxide dismutase. This is the first time that recombinant antigens have been used for the serodiagnosis of hypersensitivity pneumonitis. The availability of recombinant antigens makes it possible to develop standardized serological tests which in turn could simplify diagnosis, thus making it less invasive.
Resumo:
Introduction: Isocyanates are sensitizing chemicals used in various industries such as polyurethane foam production or paint-related purposes. Acting as haptens recognized by T-lymphocytes, they can cause allergic asthma and rarely hypersensitivity pneumonitis (HP). We aim to present a case report of acute HP due to hexamethylene diisocyanate (HDI) in a paint quality controller, a profession not generally considered at a high risk for work-related Isocyanates exposure. Case report: A 30-yr-old otherwise healthy female, light smoker working as a paint quality controller developed shortness of breath, malaise, sweating and chills at workplace six hours after handling a HDI-based hardener. Upon admission to emergency department, symptoms had progressed to severe respiratory failure. HR computer tomography (HRCT) showed bilateral ground-glass attenuation without pleural effusion. Rapid clinical and radiological improvement occurred under facial oxygen supply and systemic steroid therapy. Occupational medicine investigations revealed regular handling of HDI using latex gloves without respiratory protection. Assessment at workplace showed insufficient air renewal (1.5 times per hour), inadequate local aspiration and HDI exposure at levels of 1-4.25 ppb/m3 (Swiss Occupation Exposure Limit 5 ppb/m3). Biological monitoring after identical work procedure executed by a co-worker showed HDI exposure (5.1 micrograms hexamethylene diamine/g creatinine). Resumption of work was disadvised because of the life-threatening event. Discussion: The diagnosis of occupational HP is highly supported by classical findings on imagery and typical symptoms occurring within approved latency interval, associated with rapid clinical improvement. Although neither broncho-alveolar lavage nor specific IgG diagnosis (en route) were performed during the acute episode, various blood tests managed to rule out evidence of an infection or autoimmune disease. Other causes of HP seem unlikely as the patient did not have any recurrence of symptoms since absence from work. Workplace evaluation provided significant information on HDI exposure and allowed substantial recommendations to diminish Isocyanate exposure for the 20 still healthy laboratory co-workers. Although the entryways (air or skin) and precise mechanism of toxicity remain unclear, the present case clearly shows that Isocyanates may trigger acute HP in susceptible workers in a profession not generally considered at a high risk.
Resumo:
Hypersensitivity pneumonitis (HP) is an immunologically mediated lung disease due to the repetitive inhalation of antigens. Most new cases arise from residential exposures, notably to birds, and are thus more difficult to recognise. The present authors report a 59-yr-old male who complained of dyspnoea and cough while being treated with amiodarone. Pulmonary function tests revealed restriction and obstruction with low diffusing lung capacity for carbon monoxide and partial pressure of oxygen. A high-resolution computed tomography chest scan and bronchoalveolar lavage showed diffuse bilateral ground-glass attenuation and lymphocytic alveolitis, respectively. Initial diagnosis was amiodarone pulmonary toxicity, but because of a rapidly favourable evolution, this diagnosis was questioned. A careful environmental history revealed a close contact with lovebirds shortly before the onset of symptoms. Precipitins were strongly positive against lovebird droppings, but were negative against other avian antigens. The patient was diagnosed with hypersensitivity pneumonitis to lovebirds. Avoidance of lovebirds and steroid treatment led to rapid improvement. The present observation identifies a new causative agent for hypersensitivity pneumonitis and highlights the importance of a thorough environmental history and of searching for precipitins against antigens directly extracted from the patient's environment. These two procedures should allow a more precise classification of some cases of pneumonitis, and thus might avoid progression of active undiagnosed hypersensitivity pneumonitis to irreversible fibrosis or emphysema.
Resumo:
Diagnosis of immunoallergenic pathologies due to microorganisms such as hypersensitivity pneumonitis includes detection of circulating specific antibodies. Detection of precipitins has classically been performed using immunoprecipitation techniques with crude antigenic extracts from microorganisms implicated as etiologic agents. However, these techniques lack standardization because of the different composition of fungal antigenic extracts from one batch to another. Therefore, there is high interest in developing standardized serological diagnostic methods using recombinant antigens. Immunoproteomics have proved to be useful for identifying the immunogenic proteins in several microorganisms linked to hypersensitivity pneumonitis. With this approach, the causative microorganisms are first isolated from the environment of patients. Then the proteins are separated by two-dimensional electrophoresis and revealed by Western blotting with sera of different patients suffering from the disease compared to sera of asymptomatic exposed controls. Immunoreactive proteins are identified by mass spectrometry. Identified immunoreactive proteins found to be specific markers for the disease could be subsequently produced as recombinant antigens using various expression systems to develop ELISA tests. Using recombinant antigens, standardized ELISA techniques can be developed, with sensitivity and specificity reaching 80% and 90%, respectively, and more if using a combination of several antigens. Immunoproteomics can be applied to any environmental microorganisms, with the aim of proposing panels of recombinant antigens able to improve the sensitivity and standardization of serologic diagnosis of hypersensitivity pneumonitis, but also other mold-induced allergic diseases such as allergic broncho pulmonary aspergillosis or asthma.
Resumo:
Abstract Hypersensitivity pneumonitis is a diffuse interstitial and granulomatous lung disease caused by the inhalation of any one of a number of antigens. The objective of this study was to illustrate the spectrum of abnormalities in high-resolution computed tomography and histopathological findings related to hypersensitivity pneumonitis. We retrospectively evaluated patients who had been diagnosed with hypersensitivity pneumonitis (on the basis of clinical-radiological or clinical-radiological-pathological correlations) and had undergone lung biopsy. Hypersensitivity pneumonitis is clinically divided into acute, subacute, and chronic forms; high-resolution computed tomography findings correlate with the time of exposure; and the two occasionally overlap. In the subacute form, centrilobular micronodules, ground-glass opacities, and air trapping are characteristic high-resolution computed tomography findings, whereas histopathology shows lymphocytic inflammatory infiltrates, bronchiolitis, variable degrees of organizing pneumonia, and giant cells. In the chronic form, high-resolution computed tomography shows traction bronchiectasis, honeycombing, and lung fibrosis, the last also being seen in the biopsy sample. A definitive diagnosis of hypersensitivity pneumonitis can be made only through a multidisciplinary approach, by correlating clinical findings, exposure history, high-resolution computed tomography findings, and lung biopsy findings.
Resumo:
Background: Few studies have addressed small airway (SA) histopathological changes and their possible role in the remodeling process in idiopathic interstitial pneumonias. Objectives: To study morphological, morphometrical and immunohistochemical features of SA in idiopathic pulmonary fibrosis (usual interstitial pneumonia, UIP) and nonspecific interstitial pneumonia (NSIP). Methods: We analyzed SA pathology in lung biopsies from 29 patients with UIP and 8 with NSIP. Biopsies were compared with lung tissue from 13 patients with constrictive bronchiolitis (CB) as positive controls and 10 normal autopsied control lungs. We semi-quantitatively analyzed SA structure, inflammation, architectural features and the bronchiolar epithelial immunohistochemical expression of TGF-beta, MMP-2, 7, 9, and their tissue inhibitors (TIMP-1, 2). Results: Compared to controls, patients with UIP, NSIP and CB presented increased bronchiolar inflammation, peribronchiolar inflammation and fibrosis and decreased luminal areas. UIP patients had thicker walls due to an increase in most airway compartments. NSIP patients presented increased epithelial areas, whereas patients with CB had larger inner wall areas. All of the groups studied presented increased bronchiolar expression of MMP-7 and MMP-9, compared to the controls. Conclusion: We conclude that SAs are pathologically altered and may take part in the lung-remodeling process in idiopathic interstitial pneumonias. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Exposure to certain fungi can cause human illness. Fungi cause adverse human health effects through three specific mechanisms: generation of a harmful immune response (e.g., allergy or hypersensitivity pneumonitis); direct infection by the fungal organism; by toxic-irritant effects from mold byproducts, such as mycotoxins. In Portugal there is an increasingly industry of large facilities that produce whole chickens for domestic consumption and only few investigations have reported on fungal contamination of the poultry litter. The material used for poultry litter is varied but normally can be constitute by: pine shavings; sawdust of eucalyptus; other types of wood; peanut; coffee; sugar cane; straw; hay; grass; paper processed. Litter is one of the most contributive factors to fungal contamination in poultries. Spreading litter is one of the tasks that normally involve higher exposure of the poultry workers to dust, fungi and their metabolites, such as VOC’s and mycotoxins. After being used and removed from poultries, litter is ploughed into agricultural soils, being this practice potentially dangerous for the soil environment, as well for both humans and animals. The goal of this study was to characterize litter’s fungal contamination and also to report the incidence of keratinophilic and toxigenic fungi.
Resumo:
Certain environmental conditions in animal and plant production have been associated with increased frequency in respiratory illnesses, including asthma, chronic bronchitis, and hypersensitivity pneumonitis, in farmers occupationally exposed in swine production. The aim of this study was to characterize particulate matter (PM) contamination in seven Portuguese swine farms and determine the existence of clinical symptoms associated with asthma and other allergy diseases, utilizing the European Community Respiratory Health Survey questionnaire. Environmental assessments were performed with portable direct-reading equipment, and PM contamination including five different sizes (PM0.5, PM1.0, PM2.5, PM5.0, PM10) was determined. The distribution of particle size showed the same trend in all swine farms, with high concentrations of particles with PM5 and PM10. Results from the questionnaire indicated a trend such that subjects with diagnosis of asthma were exposed to higher concentrations of PM with larger size (PM2.5, PM5, and PM10) while subjects with sneezing, runny nose, or stuffy nose without a cold or flu were exposed to higher concentrations of PM with smaller size (PM0.5 and PM1). Data indicate that inhalation of PM in swine farm workers is associated with increased frequency of respiratory illnesses.
Resumo:
Fungi are essential to the survival of our global ecology, but they might pose a significant threat to the health of occupants when they grow in our buildings. The exposure to fungi in homes is a significant risk factor for a number of respiratory symptoms. Well-known illnesses caused by fungi include allergy and hypersensitivity pneumonitis. Environmental monitoring for fungi and their disease agents are important aspects of exposure assessment, but few guidelines exist for interpreting their health impacts. This book answers the questions: How does one detect and measure the presence of indoor fungi? What is an acceptable level of indoor fungi? How do we relate this information to human health problems?
Resumo:
Tanto el asma ocupacional como la neumonitis por hipersensibilidad, como es el pulmón del cuidador de aves, son patologías respiratorias que se pueden prevenir o disminuir su aparición mediante la evitación de la fuente antigénica. Para poder actuar de forma preventiva es de utilidad el disponer de ensayos rápidos que sean capaces de estimar la presencia de alérgeno de forma inmediata. En el marco de este proyecto de dos años de duración tenemos por objeto el desarrollar y estandarizar dos métodos rápidos, inmunocromatográficos, para la determinación de alérgenos de soja y de proteínas séricas de paloma. Alérgenos que han sido seleccionados por su importancia en el medio como agentes causales de asma y neumonitis por hipersensibilidad, respectivamente. También tenemos por objeto determinar la carga de alérgeno de soja en la fracción de partículas menores de 10 micrómetros (PM10) en los alrededores del puerto de Barcelona y comprarla con los niveles en los filtros de partículas suspendidas totales (TSP). Como pasos previos al desarrollo de los ensayos rápidos se han producido anticuerpos específicos frente al extracto de cáscara de soja de bajo peso molecular y frente al suero de paloma, se ha desarrollado un ELISA tipo sándwich para cada alérgeno y parte de los anticuerpos se ha conjugado con oro coloidal. El ensayo inmunocromatográfico para la soja presenta un límite de detección de 6.25ng/ml y ha sido validado mediante el análisis de 119 muestras ambientales, presentando una elevada especificidad y sensibilidad. El ensayo inmunocromatográfico para la determinación de antígenos séricos de paloma requiere ser validado. Mediante un métodos de ELISA de inhibición se han determinado los niveles de alérgeno de soja en filtros PM10 y TSP. A pesar de la buena correlación entre los niveles de alérgeno en ambos filtros, se observó una amplia variación en la proporción PM10/TSP entre días.
Resumo:
Introduction: Bioaerosols such as grain dust (GD) elicit direct immunological reactions within the human respiratory system. Workplace-dependent exposure to GD may induce asthma, chronic bronchitis, and hypersensitivity pneumonitis. Aims: To assess the clinical impact of occupational exposure to GD and to determine quantitative biological markers of bioaerosol exposure in grain workers. Methods: This longitudinal study has been conducted from summer 2012 to summer 2013, comprising 6 groups of 30 active workers with different GD exposure patterns (4 groups of grain workers, 2 control groups). Two evaluations at high- and low-exposing seasons take place, during which an occupational and a medical history are questionnaire-assessed, lung function is evaluated by spirometry, airway inflammation is measured by exhaled nitric oxide (eNO) and specific blood IgG and IgE are titrated. Results: The preliminary results are those of 2 of the 4 exposed groups, (harvesters and mill workers), compared to the control groups, at first assessment (n=100). Mean age is 38.4 [years]; 98% are male. Exposed groups differ from controls (p<0.05) in daily contact with animals (57% vs. 40%) and active smoking (39% vs. 11%). Grain workers have more respiratory (50%), nasal (57%), ocular (45%) and dermatologic (36%) occupational symptoms than controls (6.4%, 19%, 16%, 6.4% respectively, p<0.05). Lower mean peak-expiratory-flow (PEF) values (96.1 ± 18.9 vs. 108.2 ± 17.4 [% of predicted], p<0.05) and eNO values (13.9 ± 9.6 vs. 20.5 ± 14.7 [ppm], p<0.05) are observed in the exposed groups. Conclusion: Preliminary results show a higher prevalence of clinical symptoms and a lower mean PEF value in the groups exposed to GD.
Resumo:
Introduction: Bioaerosols such as grain dust, via biologically active agents, elicit local inflammation and direct immunological reactions within the human respiratory system. Workplace-dependent exposure to grain dust (GD) may thus induce asthma, chronic bronchitis, and hypersensitivity pneumonitis. The aim of this study is to assess the clinical impact of occupational exposure to GD and to determine quantitative biological markers of bioaerosol exposure in grain workers. Methods: This longitudinal study has been conducted from summer 2012, to summer 2013, comprising 6 groups of 30 active workers with different GD exposure patterns (4 groups of grain workers, 2 control groups). After obtaining informed consent, two evaluations at high- and low-exposing seasons take place, during which an occupational history and a detailed medical history are questionnaire-assessed, lung function is evaluated by spirometry, airway inflammation is measured by exhaled nitric oxide (eNO), and specific blood IgG and IgE are titrated. The preliminary results presented hereafter are those of two of the four exposed groups, namely harvesters and mill workers, compared to the control groups, at first assessment (n=100). Results: Mean age is 38.4 [years]; 98% are male. Exposed groups differ from controls (p<0.05) in daily contact with animals (57% vs. 40%) and active smoking (39% vs. 11%). Grain workers have more respiratory (50%), nasal (57%), ocular (45%), dermatologic (36%) and systemic (20%) occupational symptoms than controls (6.4%, 19%, 16%, 6.4%, 1.6% respectively, p<0.05). Lower mean peak-expiratory-flow (PEF) values (96.1 ± 18.9 vs. 108.2 ± 17.4 [% of predicted], p<0.05) and eNO values (13.9 ± 9.6 vs. 20.5 ± 14.7 [ppm], p<0.05) are observed in the exposed groups. Conclusion: Preliminary results show a higher prevalence of clinical symptoms and a lower mean PEF value in the exposed groups. Detailed supplementary analyses are pending.
Resumo:
In France and Finland, farmer's lung disease (FLD), a hypersensitivity pneumonitis common in agricultural areas, is mainly caused by Eurotium species. The presence of antibodies in patients' serum is an important criterion for diagnosis. Our study aimed to improve the serological diagnosis of FLD by using common fungal particles that pollute the farm environment as antigens. Fungal particles of the Eurotium species were observed in handled hay. A strain of Eurotium amstelodami was grown in vitro using selected culture media; and antigen extracts from sexual (ascospores), asexual (conidia), and vegetative (hyphae) forms were made. Antigens were tested by enzyme-linked immunosorbent assay (ELISA), which was used to test for immunoglobulin G antibodies from the sera of 17 FLD patients, 40 healthy exposed farmers, and 20 nonexposed controls. The antigens were compared by receiver operating characteristic analysis, and a threshold was then established. The ascospores contained in asci enclosed within cleistothecia were present in 38% of the hay blades observed; conidial heads of aspergillus were less prevalent. The same protocol was followed to make the three antigen extracts. A comparison of the results for FLD patients and exposed controls showed the area under the curve to be 0.850 for the ascospore antigen, 0.731 for the conidia, and 0.690 for the hyphae. The cutoffs that we determined, with the standard deviation for measures being taken into account, showed 67% for sensitivity and 92% for specificity with the ascospore antigen. In conclusion, the serological diagnosis of FLD by ELISA was improved by the adjunction of ascospore antigen.