885 resultados para HUE DISCRIMINATION
Resumo:
The visual biology of Hawaiian reef fishes was explored by examining their eyes for spectral sensitivity of their visual pigments and for transmission of light through the ocular media to the retina. The spectral absorption curves for the visual pigments of 38 species of Hawaiian fish were recorded using microspectrophotometry. The peak absorption wavelength (lambda(max)) of the rods varied from 477-502 nm and the lambda(max) of individual species conformed closely to values for the same species previously reported using a whole retina extraction procedure. The visual pigments of single cone photoreceptors were categorized, dependent on their lambda(max)-values, as ultraviolet (347-376 nm), violet (398-431 nm) or blue (439-498 nm) sensitive cones. Eight species possessed ultraviolet-sensitive cones and 14 species violet-sensitive cones. Thus, 47% of the species examined displayed photosensitivity to the short-wavelength region of the spectrum. Both identical and nonidentical paired and double cones were found with blue sensitivity or green absorption peaks (> 500 nm). Spectrophotometry of the lens, cornea, and humors for 195 species from 49 families found that the spectral composition of the light transmitted to the retina was most often limited by the lens (73% of species examined). Except for two unusual species with humor-limited eyes, Acanthocybium solandri (Scombridae) and the priacanthid fish, Heteropriacanthus cruentatus, the remainder had corneal-limited eyes. The wavelength at which 50% of the light was blocked (T50) was classified according to a system modified from Douglas and McGuigan (1989) as Type I, T50 < = 355 nm, (32 species); Type IIa, 355 < T50 < = 380 nm (30 species); Type IIb, 380 < T50 405 nm (84 species). Possession of UV-transmitting ocular media follows both taxonomic and functional lines and, if the ecology of the species is considered, is correlated with the short-wavelength visual pigments found in the species. Three types of short-wavelength vision in fishes are hypothesized: UV-sensitive, UV-specialized, and violet-specialized. UV-sensitive eyes lack UV blockers (Type I and IIa) and can sense UV light with the secondary absorption peak or beta peak of their longer wavelength visual pigments but do not possess specialized UV receptor cells and, therefore, probably lack UV hue discrimination. UV-specialized eyes allow transmission of UV light to the retina (Type I and IIa) and also possess UV-sensitive cone receptors with peak absorption between 300 and 400 nm. Given the appropriate perceptual mechanisms, these species could possess true UV-color vision and hue discrimination. Violet-specialized eyes extend into Type IIb eyes and possess violet-sensitive cone cells. UV-sensitive eyes are found throughout the fishes from at least two species of sharks to modern bony fishes. Eyes with specialized short-wavelength sensitivity are common in tropical reef fishes and must be taken into consideration when performing research involving the visual perception systems of these fishes. Because most glass and plastics are UV-opaque, great care must be taken to ensure that aquarium dividers, specimen holding containers, etc., are UV-transparent or at least to report the types of materials in use.
Resumo:
Color vision impairment emerges at early stages of diabetes mellitus type 2 (DM2) and may precede diabetic retinopathy or the appearance of vascular alterations in the retina. The aim of the present study was to compare the evaluation of the color vision with two different tests - the Lanthony desaturated D-15d test (a traditional color arrangement test), and the Cambridge Colour Test (CCT) (a computerized color discrimination test) - in patients diagnosed with DM2 without clinical signs of diabetic retinopathy (DR), and in sex- and age-matched control groups. Both color tests revealed statistically significant differences between the controls and the worst eyes of the DM2 patients. In addition, the degree of color vision impairment diagnosed by both tests correlated with the disease duration. The D-15d outcomes indicated solely tritan losses. In comparison, CCT outcomes revealed diffuse losses in color discrimination: 13.3% for best eyes and 29% for worst eyes. In addition, elevation of tritan thresholds in the DM2 patients, as detected by the Trivector subtest of the CCT, was found to correlate with the level of glycated hemoglobin. Outcomes of both tests confirm that subclinical losses of color vision are present in DM2 patients at an early stage of the disease, prior to signs of retinopathy. Considering the advantages of the CCT test compared to the D-15d test, further studies should attempt to verify and/or improve the efficiency of the CCT test.
Resumo:
The present study aimed at providing conditions for the assessment of color discrimination in children using a modified version of the Cambridge Colour Test (CCT, Cambridge Research Systems Ltd., Rochester, UK). Since the task of indicating the gap of the Landolt C used in that test proved counterintuitive and/or difficult for young children to understand, we changed the target Stimulus to a patch of color approximately the size of the Landolt C gap (about 7 degrees Of Visual angle at 50 cm from the monitor). The modifications were performed for the CCT Trivector test which measures color discrimination for the protan, deutan and tritan confusion lines. Experiment I Sought to evaluate the correspondence between the CCT and the child-friendly adaptation with adult subjects (n = 29) with normal color vision. Results showed good agreement between the two test versions. Experiment 2 tested the child-friendly software with children 2 to 7 years old (n = 25) using operant training techniques for establishing and maintaining the subjects` performance. Color discrimination thresholds were progressively lower as age increased within the age range tested (2 to 30 years old), and the data-including those obtained for children-fell within the range of thresholds previously obtained for adults with the CCT. The protan and deutan thresholds were consistently lower than tritan thresholds, a pattern repeatedly observed in adults tested with the CCT. The results demonstrate that the test is fit for assessment of color discrimination in young children and may be a useful tool for the establishment of color vision thresholds during development.
Resumo:
This work evaluated the physicochemical composition of 171 red Brazilian wines from the 2006 vintage, which were represented by 21 varietals. These wines were produced by 58 Brazilian wineries in different regions of the country, with latitudes varying from 9º to 31º South. Physicochemical wine analysis was performed in the same year and discrimination in the viticultural regions, varietal wines, and wineries was performed by means of the principal component analysis (PCA). The main results show that wines from São Joaquim had higher values of A420, A520, A620, color intensity, total phenolic compounds, anthocyanins, and dry extracts, while those from Toledo had lower values of these variables; those from Vale do São Francisco had higher values of potassium, pH, density, and volatile acidity; from Serra do Nordeste A, they had higher titratable acidity; and from Planalto Superior B, higher hue. Regarding the varietal wines, PCA mainly discriminated the wines produced from the varieties Ancellotta, Teroldego, Egiodola, Refosco, Marselan, Cabernet Sauvignon, Pinotage, Pinot Noir, Malbec, Arinarnoa, Barbera, and Alfrocheiro. In relation to wineries, twenty two of them were discriminated by their higher values of some variables, i.e., three were characterized by color intensity; three by hue; eight by alcohol content; six by potassium, dry extract, density, and pH; and two by titratablel acidity.
Resumo:
The production and commercialization of Brazilian grape juice is increasing annually, mainly due to its typicality, quality, and nutritional value. The present research was carried out in view of the great significance of Brazilian grape juice for the grape and wine industry. The purpose of this study, therefore, was to assess its composition as well as the discrimination between grape juice and other beverages. Twenty four samples of whole, sweetened, and reprocessed grape juices, grape nectar, and grape beverage were evaluated. Classical variables were analyzed by means of physicochemical methods; tartaric and malic acids, by HPLC; methanol, by gas chromatography; minerals, by atomic absorption spectrophotometry. These products were discriminated by the Principal Component Analysis (PCA). Results show that whole and sweetened grape juices were discriminated from other grape products because they featured higher values of total soluble solids, tartaric and malic acids, most minerals, phenolic compounds, and K/Na ratio, whereas grape nectar and grape beverage presented higher values of ºBrix/titratable acidity ratio. Reprocessed juice was discriminated due to its higher concentrations of Li and Na and lower hue.
Resumo:
Accurate colour vision testing requires using the correct illumination. With the plethora of 'daylight' lamps available, is there a cost-effective alternative to the discontinued MacBeth Easel lamp? Smoking is a known risk factor for macula degeneration. As the macula is responsible for colour discrimination, any toxin that affects it has the potential to influence colour discrimination. Aims: To find a costeffective light source for colour vision testing. To investigate the effect of smoking on colour discrimination. To explore how deuteranomalous trichromats compare with normal trichromats. Methods: Using the Ishihara colour vision test subjects were classified into the groups: 'Normal/Control', 'Smoker/Test', and 'Case Study' (subjects who failed the screening test and did not smoke). They completed the Farnsworth Munsell 100 Hue test under each of the three light sources: Phillips EcoHalo Twist (tungsten halogen - THL), Kosnic KCF07ALU/GU10-865 (compact fluorescent- CFL), and Deal Guardian Ltd. GU103X2WA4B-60 (light-emitting diode - LED) Results: 42 subjects took part in the study: 18 in the Normal/Control group, 18 in the Smoker/Test group, and 6 in the Case Study group. For the Normal/Control group the total error scores (TESs) were significantly lower with the CFL than with the THL (p = 0.017) as it was for the Case Study group (p = 0.009). No significant differences were found between the Normal/Control group and the Smoker/Test group for each light source. Decision tree analysis found pack years to be a significant variable for TES. Discussion: All three light sources were comparable with previous studies. The CFL provided better colour discrimination than the LED despite them both being 6500 K. Deuteranomalous trichromats showed a greatest deviation than normal trichromats using the LED. Conclusions: The Kosnic KCF07ALU/GU10-865 is a cost-effective alternative for colour vision testing. Smoking appears to have an effect on colour vision, but requires further investigation.
Resumo:
The production and commercialization of Brazilian grape juice is increasing annually, mainly due to its typicality, quality, and nutritional value. The present research was carried out in view of the great significance of Brazilian grape juice for the grape and wine industry. The purpose of this study, therefore, was to assess its composition as well as the discrimination between grape juice and other beverages. Twenty four samples of whole, sweetened, and reprocessed grape juices, grape nectar, and grape beverage were evaluated. Classical variables were analyzed by means of physicochemical methods; tartaric and malic acids, by HPLC; methanol, by gas chromatography; minerals, by atomic absorption spectrophotometry. These products were discriminated by the Principal Component Analysis (PCA). Results show that whole and sweetened grape juices were discriminated from other grape products because they featured higher values of total soluble solids, tartaric and malic acids, most minerals, phenolic compounds, and K/Na ratio, whereas grape nectar and grape beverage presented higher values of ºBrix/titratable acidity ratio. Reprocessed juice was discriminated due to its higher concentrations of Li and Na and lower hue.
Resumo:
The optimal discrimination of nonorthogonal quantum states with minimum error probability is a fundamental task in quantum measurement theory as well as an important primitive in optical communication. In this work, we propose and experimentally realize a new and simple quantum measurement strategy capable of discriminating two coherent states with smaller error probabilities than can be obtained using the standard measurement devices: the Kennedy receiver and the homodyne receiver.
Resumo:
Multispectral widefield optical imaging has the potential to improve early detection of oral cancer. The appropriate selection of illumination and collection conditions is required to maximize diagnostic ability. The goals of this study were to (i) evaluate image contrast between oral cancer/precancer and non-neoplastic mucosa for a variety of imaging modalities and illumination/collection conditions, and (ii) use classification algorithms to evaluate and compare the diagnostic utility of these modalities to discriminate cancers and precancers from normal tissue. Narrowband reflectance, autofluorescence, and polarized reflectance images were obtained from 61 patients and 11 normal volunteers. Image contrast was compared to identify modalities and conditions yielding greatest contrast. Image features were extracted and used to train and evaluate classification algorithms to discriminate tissue as non-neoplastic, dysplastic, or cancer; results were compared to histologic diagnosis. Autofluorescence imaging at 405-nm excitation provided the greatest image contrast, and the ratio of red-to-green fluorescence intensity computed from these images provided the best classification of dysplasia/cancer versus non-neoplastic tissue. A sensitivity of 100% and a specificity of 85% were achieved in the validation set. Multispectral widefield images can accurately distinguish neoplastic and non-neoplastic tissue; however, the ability to separate precancerous lesions from cancers with this technique was limited. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3516593]
Resumo:
A rapid method for classification of mineral waters is proposed. The discrimination power was evaluated by a novel combination of chemometric data analysis and qualitative multi-elemental fingerprints of mineral water samples acquired from different regions of the Brazilian territory. The classification of mineral waters was assessed using only the wavelength emission intensities obtained by inductively coupled plasma optical emission spectrometry (ICP OES), monitoring different lines of Al, B, Ba, Ca, Cl, Cu, Co, Cr, Fe, K, Mg, Mn, Na, Ni, P, Pb, S, Sb, Si, Sr, Ti, V, and Zn, and Be, Dy, Gd, In, La, Sc and Y as internal standards. Data acquisition was done under robust (RC) and non-robust (NRC) conditions. Also, the combination of signal intensities of two or more emission lines for each element were evaluated instead of the individual lines. The performance of two classification-k-nearest neighbor (kNN) and soft independent modeling of class analogy (SIMCA)-and preprocessing algorithms, autoscaling and Pareto scaling, were evaluated for the ability to differentiate between the various samples in each approach tested (combination of robust or non-robust conditions with use of individual lines or sum of the intensities of emission lines). It was shown that qualitative ICP OES fingerprinting in combination with multivariate analysis is a promising analytical tool that has potential to become a recognized procedure for rapid authenticity and adulteration testing of mineral water samples or other material whose physicochemical properties (or origin) are directly related to mineral content.
Resumo:
Sound source localization (SSL) is an essential task in many applications involving speech capture and enhancement. As such, speaker localization with microphone arrays has received significant research attention. Nevertheless, existing SSL algorithms for small arrays still have two significant limitations: lack of range resolution, and accuracy degradation with increasing reverberation. The latter is natural and expected, given that strong reflections can have amplitudes similar to that of the direct signal, but different directions of arrival. Therefore, correctly modeling the room and compensating for the reflections should reduce the degradation due to reverberation. In this paper, we show a stronger result. If modeled correctly, early reflections can be used to provide more information about the source location than would have been available in an anechoic scenario. The modeling not only compensates for the reverberation, but also significantly increases resolution for range and elevation. Thus, we show that under certain conditions and limitations, reverberation can be used to improve SSL performance. Prior attempts to compensate for reverberation tried to model the room impulse response (RIR). However, RIRs change quickly with speaker position, and are nearly impossible to track accurately. Instead, we build a 3-D model of the room, which we use to predict early reflections, which are then incorporated into the SSL estimation. Simulation results with real and synthetic data show that even a simplistic room model is sufficient to produce significant improvements in range and elevation estimation, tasks which would be very difficult when relying only on direct path signal components.
Resumo:
Landscape unit discrimination for pedological surveys by orbital spectral response. The objective of tins study was compare two soil survey methods. The first was performed by methods traditionally used to distinguish landscape units and soil class discrimination. The second was based on soil class distinction through orbital spectral response. In order to establish soil characteristics and their classification, soil samples were collected at two depths in a grid system, with a distance of 500 meters between points. With these samples, physical and chemical analyses were carried out. In the sampling points, the apparent reflectance of the soil, front the orbital image, was determined and, through cluster analysis landscape units were established. In order to evaluate the resemblance reliability between the landscape units established in each method, the Kappa index was used, the value set for the confusion matrix was 0.43, indicating high quality in the comparison, showing that the non-conventional method was as close as the one carried out by photointerpretation.
Resumo:
Transpiration efficiency, W, the ratio of plant carbon produced to water transpired and carbon isotope discrimination of leaf dry matter, Delta(d)' were measured together on 30 lines of the C-4 species, Sorghum bicolor in the glasshouse and on eight lines grown in the field. In the glasshouse, the mean W observed was 4.9 mmol C mol(-1) H2O and the range was 0.8 mmol C mol(-1) H2O The mean Delta(d) was 3.0 parts per thousand and the observed range was 0.4 parts per thousand. In the field, the mean W was lower at 2.8 mmol C mol H2O and the mean Delta(d) was 4.6 parts per thousand. Significant positive correlations between W and Delta(d) were observed for plants grown in the glasshouse and in the field. The observed correlations were consistent with theory, opposite to those for C-4 species, and showed that variation in Delta(d) was an integrated measure of long-term variation in the ratio of intercellular to ambient CO2 partial pressure, p(i)/p(a). Detailed gas exchange measurements of carbon isotope discrimination during CO2 uptake, Delta(A) and p(i)/p(a) were made on leaves of eight S. bicolor lines. The observed relationship between Delta(A) and p(i)/p(a) was linear with a negative slope of 3.7 parts per thousand in Delta(A) for a unit change in p(i)/p(a). The slope of this linear relationship between Delta(A) and p(i)/p(a) in C-4 species is dependent on the leakiness of the CO2 concentrating mechanism of the C pathway, We estimated the leakiness (defined as the fraction of CO2 released in the bundle sheath by C-4 acid decarboxylations, which is lost by leakage) to be 0.2. We conclude that, although variation in Delta(d) observed in the 30 lines of S. bicolor is smaller than that commonly observed in C-4 species, it also reflects variation in transpiration efficiency, W. Among the eight lines examined in detail and in the environments used, there was considerable genotype x environment interaction.
Resumo:
A dissociation between two putative measures of resource allocation skin conductance responding, and secondary task reaction time (RT), has been observed during auditory discrimination tasks. Four experiments investigated the time course of the dissociation effect with a visual discrimination task. participants were presented with circles and ellipses and instructed to count the number of longer-than-usual presentations of one shape (task-relevant) and to ignore presentations of the other shape (task-irrelevant). Concurrent with this task, participants made a speeded motor response to an auditory probe. Experiment 1 showed that skin conductance responses were larger during task-relevant stimuli than during task-irrelevant stimuli, whereas RT to probes presented at 150 ms following shape onset was slower during task-irrelevant stimuli. Experiments 2 to 4 found slower RT during task-irrelevant stimuli at probes presented at 300 ms before shape onset until 150 ms following shape onset. At probes presented 3,000 and 4,000 ms following shape onset probe RT was slower during task-relevant stimuli. The similarities between the observed time course and the so-called psychological refractory period (PRF) effect are discussed.
Resumo:
Two experiments examined whether a measure of implicit stereotyping based on the tendency to explain Black stereotype-incongruent events more often than Black stereotype-congruent events (Stereotypic Explanatory Bias or SEB) is predictive of behavior toward a partner in an interracial interaction. In Experiment I SEB predicted White males' choice to ask stereotypic questions of a Black female (but not a White male or White female) in an interview. In Experiment 2 the type of explanation (internal or external attribution) made for stereotype-inconsistency was examined. Results showed that White participants who made internal attributions for Black stereotype-incongruent behavior were rated more positively and those who made external attributions were rated more negatively by a Black male confederate. These results point to the potential of implicit stereotyping as an important predictor of behavior in an interracial interaction. (C) 2002 Elsevier Science (USA). All rights reserved.