979 resultados para HR-CS FMAS
Resumo:
National Health Surveillance Agency (ANVISA) established in the decree number 54 maximum allowed levels for Ni and Pb in mineral and natural waters at 20 µg L-1 and 10 µg L-1, respectively. For screening analysis purposes, the high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS FAAS) was evaluated for the fast-sequential determination of nickel and lead in mineral waters.Two atomic lines for Ni (232.003 nm - main and 341.477 nm - secondary) and Pb (217.0005 nm - main and 283.306 nm - secondary) at different wavelength integrated absorbance (number of pixels) were evaluated. Sensitivity enhanced with the increase of the number of pixels and with the summation of the atomic lines absorbances. The main figures of merit associated to the HR-CS FAAS technique were compared with that obtained by line-source flame atomic absorption spectrometry (LS FAAS). Water samples were pre-concentrated about 5-fold by evaporation before analysis. Recoveries of Pb significantly varied with increased wavelength integrated absorbance. Better recoveries (92-93%) were observed for higher number of pixels at the main line or summating the atomic lines (90-92%). This influence was irrelevant for Ni, and recoveries in the 92-104% range were obtained in all situations.
Resumo:
Microwave-assisted acid decomposition, direct dilution in kerosene, and oil-in-water emulsion were evaluated as lubricating oil pretreatment procedures for Cu, Cr, Fe, Ni, Pb, Sb, and Zn determination by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS). For wet digestion, results were compared with those obtained by Flame Atomic Absorption Spectrometry (FAAS). The ultrasound probe used in emulsions sonication contaminated samples with Cr, although better results have been observed for the other six elements in this condition. In general, recovery percentages ranging from 81-106%(Cu), 80-107%(Cr), 85-114%(Fe), 82-116%(Ni), 86-117%(Pb), 85-115%(Sb), and 81-114%(Zn) were obtained. The HR-CS FAAS showed to be faster and more sensitive than FAAS.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A simple method to determine Cu, Fe, Mn and Zn in single aliquots of medicinal plants by HR-CS FAAS is proposed. The main lines for Cu, Mn and Zn, and the alternate line measured at the wing of the main line for Fe at 248.327 nm allowed calibration within the 0.025 - 2.0 mg L-1 Cu, 1.0 - 20.0 mg L-1 Fe, 0.05 - 2.0 mg L-1 Mn, 0.025 - 0.75 mg L-1 Zn ranges. Nineteen medicinal plants and two certified plant reference materials were analyzed. Results were in agreement at a 95% confidence level (paired t-test) with reference values. Limits of detection were 0.12 μg L-1 Cu, 330 μg L-1 Fe, 1.42 μg L-1 Mn and 8.12 μg L-1 Zn. Relative standard deviations (n=12) were ≤ 3% for all analytes. Recoveries in the 89 - 105% (Cu), 95 - 108% (Fe), 94 - 107% (Mn), and 93 - 110% (Zn) ranges were obtained.
Resumo:
Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. The objective of this study was to develop a simple and rapid analytical method for the extraction and pre-concentration based on extraction phenomenon cloud point for the determination of Cd, Pb and Tl in produced water samples by spectrometry of high resolution Absorption source continues and atomization graphite furnace. The Box Behnken design was used to obtain the optimal condition of extraction of analytes. The factors were evaluated: concentration of complexing agent (o,o-dietilditilfosfato ammonium, DDTP), the concentration of hydrochloric acid and concentration of surfactant (Triton X -114). The optimal condition obtained through extraction was: 0,6% m v-1 DDTP, HCl 0,3 mol L-1 and 0,2% m v-1 of Triton X - 114 for Pb; 0,7% m v-1 DDTP, HCl 0,8 mol L-1 and 0,2% m v-1 Triton X-114 for Cd. For Tl was evidenced that best extraction condition occurs with no DDTP, the extraction conditions were HCl 1,0 mol L-1 e 1,0% m v-1 de Triton X - 114. The limits of detection for the proposed method were 0,005 µg L-1 , 0,03 µg L-1 and 0,09 µg L-1 to Cd, Pb and Tl, Respectively. Enrichment factors Were greater than 10 times. The method was applied to the water produced in the Potiguar basin, and addition and recovery tests were performed, and values were between 81% and 120%. The precision was expressed with relative standard deviation (RSD) is less than 5%
Resumo:
The determination and monitoring of metallic contaminants in water is a task that must be continuous, leading to the importance of the development, modification and optimization of analytical methodologies capab le of determining the various metal contaminants in natural environments, because, in many cases, the ava ilable instrumentation does not provide enough sensibility for the determination of trace values . In this study, a method of extraction and pre- concentration using a microemulsion system with in the Winsor II equilibrium was tested and optimized for the determination of Co, Cd, P b, Tl, Cu and Ni through the technique of high- resolution atomic absorption spectrometry using a continuum source (HR-CS AAS). The optimization of the temperature program for the graphite furnace (HR-CS AAS GF) was performed through the pyrolysis and atomization curves for the analytes Cd, Pb, Co and Tl with and without the use of different chemical modifiers. Cu and Ni we re analyzed by flame atomization (HR-CS F AAS) after pre-concentr ation, having the sample introduction system optimized for the realization of discrete sampling. Salinity and pH levels were also analyzed as influencing factors in the efficiency of the extraction. As final numbers, 6 g L -1 of Na (as NaCl) and 1% of HNO 3 (v/v) were defined. For the determination of the optimum extraction point, a centroid-simplex statistical plan was a pplied, having chosen as the optimum points of extraction for all of the analytes, the follo wing proportions: 70% aqueous phase, 10% oil phase and 20% co-surfactant/surfactant (C/S = 4). After extraction, the metals were determined and the merit figures obtained for the proposed method were: LOD 0,09, 0,01, 0,06, 0,05, 0,6 and 1,5 μg L -1 for Pb, Cd, Tl, Co, Cu and Ni, re spectively. Line ar ranges of ,1- 2,0 μg L -1 for Pb, 0,01-2,0 μg L -1 for Cd, 1,0 - 20 μg L -1 for Tl, 0,1-5,0 μg L -1 for Co, 2-200 μg L -1 and for Cu e Ni 5-200 μg L -1 were obtained. The enrichment factors obtained ranged between 6 and 19. Recovery testing with the certified sample show ed recovery values (n = 3, certified values) after extraction of 105 and 101, 100 and 104% for Pb, Cd, Cu and Ni respectively. Samples of sweet waters of lake Jiqui, saline water from Potengi river and water produced from the oil industry (PETROBRAS) were spiked and the recovery (n = 3) for the analytes were between 80 and 112% confirming th at the proposed method can be used in the extraction. The proposed method enabled the sepa ration of metals from complex matrices, and with good pre-concentration factor, consistent with the MPV (allowed limits) compared to CONAMA Resolution No. 357/2005 which regulat es the quality of fresh surface water, brackish and saline water in Brazil.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The present paper reports the amount and estimated daily mineral intake of nine elements (Ca, Mg, K, Na, P, Fe, Mn, Cr and Ni) in commercial instant coffees and coffee substitutes (n = 49). Elements were quantified by high-resolution continuum source flame (HR-CS-FAAS) and graphite furnace (HR-CS-GFAAS) atomic absorption spectrometry, while phosphorous was evaluated by a standard vanadomolybdophosphoric acid colorimetric method. Instant coffees and coffee substitutes are rich in K, Mg and P (>100 mg/100 g dw), contain Na, Ca and Fe in moderate amounts (>1 mg/100 g), and trace levels of Cr and Ni. Among the samples analysed, plain instant coffees are richer in minerals (p < 0.001), except for Na and Cr. Blends of coffee substitutes (barley, malt, chicory and rye) with coffee (20–66%) present intermediate amounts, while lower quantities are found in substitutes without coffee, particularly in barley. From a nutritional point of view the results indicate that the mean ingestion of two instant beverages per day (total of 4 g instant powder), either with or without coffee, cannot be regarded as important sources of minerals to the human diet, although providing a supplementation of some minerals, particularly Mg and Mn in instant coffees. Additionally, and for authentication purposes, the correlations observed between some elements and the coffee percentage in the blends, with particular significance for Mg amounts, provides a potential tool for the estimation of coffee in substitute blends.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The mineral content (phosphorous (P), potassium (K), sodium (Na), calcium (Ca), magnesium (Mg), iron (Fe), manganese (Mn), zinc (Zn) and copper (Cu)) of eight ready-to-eat baby leaf vegetables was determined. The samples were subjected to microwave-assisted digestion and the minerals were quantified by High-Resolution Continuum Source Atomic Absorption Spectrometry (HR-CS-AAS) with flame and electrothermal atomisation. The methods were optimised and validated producing low LOQs, good repeatability and linearity, and recoveries, ranging from 91% to 110% for the minerals analysed. Phosphorous was determined by a standard colorimetric method. The accuracy of the method was checked by analysing a certified reference material; results were in agreement with the quantified value. The samples had a high content of potassium and calcium, but the principal mineral was iron. The mineral content was stable during storage and baby leaf vegetables could represent a good source of minerals in a balanced diet. A linear discriminant analysis was performed to compare the mineral profile obtained and showed, as expected, that the mineral content was similar between samples from the same family. The Linear Discriminant Analysis was able to discriminate different samples based on their mineral profile.
Resumo:
Pea-shoots are a new option as ready-to-eat baby-leaf vegetable. However, data about the nutritional composition and the shelf-life stability of these leaves, especially their phytonutrient composition is scarce. In this work, the macronutrient, micronutrient and phytonutrients profile of minimally processed pea shoots were evaluated at the beginning and at the end of a 10-day storage period. Several physicochemical characteristics (color, pH, total soluble solids, and total titratable acidity) were also monitored. Standard AOAC methods were applied in the nutritional value evaluation, while chromatographic methods with UV–vis and mass detection were used to analyze free forms of vitamins (HPLC-DAD-ESI-MS/MS), carotenoids (HPLC-DAD-APCI-MSn) and flavonoid compounds (HPLC-DAD-ESI-MSn). Atomic absorption spectrometry (HR-CS-AAS) was employed to characterize the mineral content of the leaves. As expected, pea leaves had a high water (91.5%) and low fat (0.3%) and carbohydrate (1.9%) contents, being a good source of dietary fiber (2.1%). Pea shoots showed a high content of vitamins C, E and A, potassium and phosphorous compared to other ready-to-eat green leafy vegetables. The carotenoid profile revealed a high content of β-carotene and lutein, typical from green leafy vegetables. The leaves had a mean flavonoid content of 329 mg/100 g of fresh product, mainly composed by glycosylated quercetin and kaempferol derivatives. Pea shoots kept their fresh appearance during the storage being color maintained throughout the shelf-life. The nutritional composition was in general stable during storage, showing some significant (p < 0.05) variation in certain water-soluble vitamins.
Resumo:
SummarySecondary lymphoid organs, such as lymph nodes or spleen, are the only places in our body where primary adaptive immune responses are efficiently elicited. These organs have distinct Β and Τ cell rich zones and Τ lymphocytes constantly migrate from the bloodstream into Τ zones to scan dendritic cells (DCs) for antigens they present. Specialized fibroblasts, the Τ zone reticular cells (HR.Cs), span the Τ zone in the form a three-dimensional network. lK.Cs guide incoming Τ cells in their migration, both chemically, by the secretion of the chemokines CCL19 and CCL21, and physically, by construction of a road system to which also DCs adhere. In this way TRCs are thought to facilitate encounters of Τ cells with antigen-bearing DCs and thereby accelerate the selection of rare antigen-specific Τ cells. The resulting Τ cell activation, proliferation and differentiation all take place within the TRC network. However, the influence of TRCs on Τ cell activation has so fer not been elucidated with the possible reasons being that TRCs represent a relative rare cell population and that mice devoid of TRCs have not been described.To circumvent these technical limitations, we established TRC clones and lines to have an abundant source to functionally characterize TRCs. Both the clones and lines show a fibroblastic phenotype, express a surface marker profile comparable to ex vivo TRCs and produce extracellular matrix molecules. However, expression of Ccl19, Ccl21 and ZL-7 is lost and could not be restored by cytokine stimulation. When these TRC clones or lines were cultured in a three-dimensional cell culture system, their morphology changed and resembled that of in vivo TRCs as they formed networks. By adding Τ cells and antigen-loaded DCs to these cultures we successfully reconstructed lymphoid Τ zones that allowed antigen-specific Τ cell activation.To characterize the role of TRCs in Τ cell priming, TRCs were co-cultured with antigen-specific Τ cells in the presence antigen-loaded DCs. Surprisingly, the presence of TRC lines and ex vivo TRCs inhibited rather than enhanced CD8+ Τ cell activation, proliferation and effector cell differentiation. TRCs shared this feature with fibroblasts from non-lymphoid tissues as well as mesenchymal stromal cells. TRCs were identified as a strong source of nitric oxide (NO) thereby directly dampening Τ cell expansion as well as reducing the Τ cell priming capacity of DCs. The expression of inducible NO synthase (iNOS) was up- regulated in a subset of TRCs by both DC-signals as well as interferon-γ produced by primed CD8+ Τ cells. Importantly, iNOS expression was induced during viral infection in vivo in both lymph node TRCs and DCs. Consistent with a role for NO as a negative regulator, the primary Τ cell response was exaggerated in iNOS-/- mice. Our findings highlight that in addition to their established positive roles in Τ cell responses TRCs and DCs cooperate in a negative feedback loop to attenuate Τ cell expansion during acute inflammation.RésuméLes organes lymphoïdes secondaires, comme les ganglions lymphoïdes ou la rate, sont les seuls sites dans notre corps où la réponse primaire des lymphocytes Β et Τ est initiée efficacement. Ces organes ont des zones différentes, riches en cellules Β ou T. Des lymphocytes Τ circulent constamment du sang vers les zones T, où ils échantillonent la surface des cellules dendritiques (DCs) pour identifier les antigènes qu'ils présentent. Des fibroblastes spécialisés - nommés Τ zone reticular cells (TRCs)' forment un réseau tridimensionnel dans la zone T. Les TRCs guident la migration des cellules Τ par deux moyens: chimiquement, par la sécrétion des chimiokines CCL19 et CCL21 et physiquement, par la construction d'un réseau routier en trois dimensions, auquel adhèrent aussi des DCs. Dans ce? cas, on pense que la présence des TRCs facilite les rencontres entre les cellules Τ et les DCs chargées de l'antigène et accélère la sélection des rares cellules Τ spécifiques. Ensuite, l'activation de cellules T, ainsi que la prolifération et la différenciation se produisent toutes à l'intérieur du réseau des TRCs. L'influence des TRCs sur l'activation des cellules T n'est que très peu caractérisée, en partie parce que les TRCs représentent une population rare et que les souris déficientes dans les TRCs n'ont pas encore été découvertes.Pour contourner ces limitations techniques, nous avons établi des clones et des lignées cellulaires de TRC pour obtenir une source indéfinie de ces cellules permettant leur caractérisation fonctionnelle. Les clones et lignées établis ont un phénotype de fibroblaste, ils expriment des molécules de surface similaires aux TRCs ex vivo et produisent de la matrice extracellulaire. Mais l'expression de Ccl19, Ccl21 et 11-7 est perdue et ne peut pas être rétablie par stimulation avec différentes cytokines. Les clones TRC ou les lignées cultivées en un système tridimensionnel de culture cellulaire, montrent une morphologie changée, qui ressemble à celle de TRC ex vivo inclus la construction de réseaux tridimensionnels.Pour caractériser le rôle des TRC dans l'activation des cellules T, nous avons cultivé des TRCs avec des cellules T spécifiques et des DCs chargées avec l'antigène. Etonnamment, la présence des TRC (lignées et ex vivo) inhibait plutôt qu'elle améliorait l'activation, la prolifération et la différenciation des lymphocytes T CDS+. Les TRCs partageaient cette fonction avec des fibr-oblastes des organes non lymphoïdes et des cellules souches du type mésenchymateux. Dans ces conditions, les TRCs sont une source importante d'oxyde nitrique (NO) et par ce fait limitent directement l'expansion des cellules T et réduisent aussi la capacité des DCs à activer les cellules T. L'expression de l'enzyme NO synthase inductible (ïNOS) est régulée à la hausse par des signaux dérivés des DCs et par l'interféron-γ produit par des cellules T de type CD8+ activées. Plus important, l'expression d'iNOS est induite pendant une infection virale in vivo, dans les TRCs et dans les DCs. Par conséquent, la réponse primaire de cellules T est exagérée dans des souris iNOS-/-. Nos résultats mettent en évidence qu'en plus de leur rôle positif bien établi dans la réponse immunitaire, les TRCs et les DCs coopèrent dans une boucle de rétroaction négative pour atténuer l'expansion des cellules T pendant l'inflammation aigiie pour protéger l'intégrité et la fonctionnalité des organes lymphoïdes secondaires.
Resumo:
This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324.754 nm, 327.396 nm, 222.570 nm, 249.215 nm and 224.426 nm were evaluated and main figures of merit established. Absorbance measurements at 324.754 nm, 249.215 nm and 224.426 nm allows the determination of Cu in the 0.07 - 5.0 mg L-1, 5.0 - 100 mg L-1 and 100 - 800 mg L-1 concentration intervals respectively with linear correlation coefficients better than 0.998. Limits of detection were 21 µg L-1, 310 µg L-1 and 1400 µg L-1 for 324.754 nm, 249.215 nm and 224.426 nm, respectively and relative standard deviations (n = 12) were £ 2.7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry.
Resumo:
Neste trabalho foram investigados diferentes métodos de preparação de amostra para a determinação de níquel e vanádio em óleo cru usando a espectrometria de absorção atômica com forno de grafite (GF AAS). Investigou-se o uso de xileno como diluente, o qual foi inadequado devido à baixa estabilidade de níquel nas soluções e resultando na contaminação do equipamento. As soluções diluídas em isobutilmetilcetona apresentaram melhor estabilidade, mas não houve reprodutibilidade das medidas com os padrões orgânicos de níquel. Melhores resultados foram obtidos com emulsões óleo-em-água, usando Triton X-100 como surfactante. Também foi estudado o uso de padrões aquosos (inorgânicos) para o preparo das emulsões. Após o estabelecimento de curvas de pirólise para padrão e amostra de óleo cru, observou-se diferença no comportamento térmico do níquel na matriz de óleo cru. Foi então realizada uma investigação usando um espectrômetro de absorção atômica com fonte contínua de alta resolução (HR-CS AAS), equipamento com elevada capacidade de correção de fundo, e constatou-se que cerca de 50 % do analito é perdido em temperaturas abaixo de 400 ºC, enquanto que o restante é termicamente estável até pelo menos 1200 ºC. A fim de resolver o problema de perda de níquel volátil, foi investigado o uso de paládio como modificador químico. Através de curvas de pirólise com e sem paládio, observou-se que a mesma perda também ocorreu para o vanádio. Após a otimização da melhor quantidade de paládio, verificou-se que foi necessária uma quantidade de 20 µg de paládio para estabilização de níquel e vanádio. A determinação de níquel e vanádio total em amostras de óleo cru foi realizada usando-se paládio como modificador químico. A especiação destes elementos foi possível através da determinação das espécies estáveis, provavelmente compostos salinos não porfirínicos de níquel e vanádio, sem a adição de paládio, e a fração de compostos voláteis (provavelmente porfirinas de níquel e vanádio) foi calculada por diferença. Estabeleceram-se as figuras de mérito obtendo-se valores de massa característica de 19 e 33 pg e limite de detecção de 43 e 113 pg para níquel e vanádio, respectivamente. Esses resultados são compatíveis com dados reportados na literatura. A exatidão deste procedimento foi verificada pela análise dos materiais de referência certificados de metais traço em óleo residual (SRM 1634c) para níquel e vanádio e o petróleo (RM 8505) somente para vanádio e também por comparação com os resultados obtidos por HR-CS AAS para várias amostras de óleo cru. A aplicação do teste estatístico t-student aos resultados de níquel e vanádio total obtidos por GF AAS e HR-CS AAS mostrou que os mesmos não são significativamente diferentes a um nível de 95% de confiança.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)