923 resultados para HOUSES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditionally, the main focus of the professional community involved with indoor air quality has been indoor pollution sources, preventing or reducing their emissions, as well as lowering the impact of the sources by replacing the polluted indoor air with "fresh" outdoor air. However, urban outdoor air cannot often be considered "fresh", as it contains high concentrations of pollutants emitted from motor vehicles - the main outdoor pollution sources in cities. Evidence from epidemiological studies conducted worldwide demonstrates that outdoor air quality has considerable effects on human health, despite the fact that people spend the majority of their time indoors. This is because pollution from outdoors penetrates indoors and becomes a major constituent of indoor pollution. Urban land and transport development has significant impact on the overall air quality of the urban airshed as well as the pollution concentration in the vicinity of high-density traffic areas. Therefore, an overall improvement in indoor air quality would be achieved by lowering urban airshed pollution, as well as by lowering the impact of the hot spots on indoor air. This paper explores the elements of urban land and vehicle transport developments, their impact on global and local air quality, and how the science of outdoor pollution generation and transport in the air could be utilized in urban development towards lowering indoor air pollution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characterization of indoor particle sources from 14 residential houses in Brisbane, Australia, was performed. The approximation of PM2.5 and the submicrometre particle number concentrations were measured simultaneously for more than 48 h in the kitchen of all the houses by using a photometer (DustTrak) and a condensation particle counter (CPC), respectively. From the real time indoor particle concentration data and a diary of indoor activities, the indoor particle sources were identified. The study found that among the indoor activities recorded in this study, frying, grilling, stove use, toasting, cooking pizza, smoking, candle vaporizing eucalyptus oil and fan heater use, could elevate the indoor particle number concentration levels by more than five times. The indoor approximation of PM2.5 concentrations could be close to 90 times, 30 times and three times higher than the background levels during grilling, frying and smoking, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of a large study investigating indoor air in residential houses in Brisbane, Australia, the purpose of this work was to quantify indoor exposure to submicrometer particles and PM2.5 for the inhabitants of 14 houses. Particle concentrations were measured simultaneously for more than 48 hours in the kitchens of all the houses by using a condensation particle counter (CPC) and a photometer (DustTrak). The occupants of the houses were asked to fill in a diary, noting the time and duration of any activity occurring throughout the house during measurement, as well as their presence or absence from home. From the time series concentration data and the information about indoor activities, exposure to the inhabitants of the houses was calculated for the entire time they spent at home as well as during indoor activities resulting in particle generation. The results show that the highest median concentration level occurred during cooking periods for both particle number concentration (47.5´103 particles cm-3) and PM2.5 concentration (13.4 mg m-3). The highest residential exposure period was the sleeping period for both particle number exposure (31%) and PM2.5 exposure (45.6%). The percentage of the average residential particle exposure level in total 24h particle exposure level was approximating 70% for both particle number and PM2.5 exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of a larger indoor environmental study, residential indoor and outdoor levels of nitrogen dioxide (NO2) were measured for 14 houses in a suburb of Brisbane, Queensland, Australia. Passive samplers were used for 48-h sampling periods during the winter of 1999. The average indoor and outdoor NO2 levels were 13.8 ± 6.3 and 16.7 ± 4.2 ppb, respectively. The indoor/outdoor NO2 concentration ratio ranged from 0.4 to 2.3, with a median value of 0.82. The results of statistic analyses indicated that there was no significant correlation between indoor and outdoor NO2 concentrations, or between indoor and fixed site NO2 monitoring station concentrations. However, there was a significant correlation between outdoor and fixed site NO2 monitoring station concentrations. There was also a significant correlation between indoor NO2 concentration and indoor submicrometre (0.007–0.808 μm) aerosol particle number concentrations. The results in this study indicated indoor NO2 levels are significantly affected by indoor NO2 sources, such as a gas stove and cigarette smoking. It implies that the outdoor or fixed site monitoring concentration alone is a poor predictor of indoor NO2 concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of flooding events occurred in Queensland, Australia during December 2010 and January 2011. The state’s capital city of Brisbane experienced major flooding in January 2011, when the Brisbane River broke its bank and inundated low lying areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many Brisbane houses were affected by water inundation as a result of the flooding event which occurred in January 2011. The combination of waterlogged materials and large amounts of silt and organic debris in affected homes gave rise to a situation where exposures to airborne particles could potentially be elevated. However, swift action to remove wet materials and dry out the building structures can help to reduce moisture and humidity in flooded houses, in an effort to prevent the growth of bacteria and mould and improve indoor air quality in and around flooded areas. To test this hypothesis, field measurements were carried out during 21 March and 3 May, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vietnam has a unique culture which is revealed in the way that people have built and designed their traditional housing. Vietnamese dwellings reflect occupants’ activities in their everyday lives, while adapting to tropical climatic conditions impacted by seasoning monsoons. It is said that these characteristics of Vietnamese dwellings have remained unchanged until the economic reform in 1986, when Vietnam experienced an accelerated development based on the market-oriented economy. New housing types, including modern shop-houses, detached houses, and apartments, have been designed in many places, especially satisfying dwellers’ new lifestyles in Vietnamese cities. The contemporary housing, which has been mostly designed by architects, has reflected rules of spatial organisation so that occupants’ social activities are carried out. However, contemporary housing spaces seem unsustainable in relation to socio-cultural values because they has been influenced by globalism that advocates the use of homogeneous spatial patterns, modern technologies, materials and construction methods. This study investigates the rules of spaces in Vietnamese houses that were built before and after the reform to define the socio-cultural implications in Vietnamese housing design. Firstly, it describes occupants’ views of their current dwellings in terms of indoor comfort conditions and social activities in spaces. Then, it examines the use of spaces in pre-reform Vietnamese housing through occupants’ activities and material applications. Finally, it discusses the organisation of spaces in both pre- and post-reform housing to understand how Vietnamese housing has been designed for occupants to live, act, work, and conduct traditional activities. Understanding spatial organisation is a way to identify characteristics of the lived spaces of the occupants created from the conceived space, which is designed by designers. The characteristics of the housing spaces will inform the designers the way to design future Vietnamese housing in response to cultural contexts. The study applied an abductive approach for the investigation of housing spaces. It used a conceptual framework in relation to Henri Lefebvre’s (1991) theory to understand space as the main factor constituting the language of design, and the principles of semiotics to examine spatial structure in housing as a language used in the everyday life. The study involved a door-knocking survey to 350 households in four regional cities of Vietnam for interpretation of occupancy conditions and levels of occupants’ comfort. A statistical analysis was applied to interpret the survey data. The study also required a process of data selection and collection of fourteen cases of housing in three main climatic regions of the country for analysing spatial organisation and housing characteristics. The study found that there has been a shift in the relationship of spaces from the pre- to post-reform Vietnamese housing. It also indentified that the space for guest welcoming and family activity has been the central space of the Vietnamese housing. Based on the relationships of the central space with the others, theoretical models were proposed for three types of contemporary Vietnamese housing. The models will be significant in adapting to Vietnamese conditions to achieve socioenvironmental characteristics for housing design because it was developed from the occupants’ requirements for their social activities. Another contribution of the study is the use of methodological concepts to understand the language of living spaces. Further work will be needed to test future Vietnamese housing designs from the applications of the models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In January 2011, Brisbane, Australia, experienced a major river flooding event. We aimed to investigate its effects on air quality and assess the role of prompt cleaning activities in reducing the airborne exposure risk. A comprehensive, multi-parameter indoor and outdoor measurement campaign was conducted in 41 residential houses, 2 and 6 months after the flood. The median indoor air concentrations of supermicrometer particle number (PN), PM10, fungi and bacteria 2 months after the flood were comparable to those previously measured in Brisbane. These were 2.88 p cm-3, 15 µg m-3, 804 cfu m-3 and 177 cfu m-3 for flood-affected houses (AFH), and 2.74 p cm-3, 15 µg m-3, 547 cfu m-3 and 167 cfu m-3 for non-affected houses (NFH), respectively. The I/O (indoor/outdoor) ratios of these pollutants were 1.08, 1.38, 0.74 and 1.76 for AFH and 1.03, 1.32, 0.83 and 2.17 for NFH, respectively. The average of total elements (together with transition metals) in indoor dust was 2296 ± 1328 µg m-2 for AFH and 1454 ± 678 µg m-2 for NFH, respectively. In general, the differences between AFH and NFH were not statistically significant, implying the absence of a measureable effect on air quality from the flood. We postulate that this was due to the very swift and effective cleaning of the flooded houses by 60,000 volunteers. Among the various cleaning methods, the use of both detergent and bleach was the most efficient at controlling indoor bacteria. All cleaning methods were equally effective for indoor fungi. This study provides quantitative evidence of the significant impact of immediate post-flood cleaning on mitigating the effects of flooding on indoor bioaerosol contamination and other pollutants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Life cycle energy analysis (LCEA) of eight residential buildings in and around Brisbane, Queensland, Australia, is undertaken in this study. Energy used in all three phases of construction, operation and demolition are considered. It is found that the main contribution to the operational energy in residential buildings is from use of general appliance. The choice of building materials is shown to have significant effects on the embodied energy for the production, construction, maintenance and demolition phases. From this study, it is shown that the embodied energy may vary from 10% to 30%, while the operational energy may vary from 65% to 90%. The demolition energy generally accounts for less than 4% of life cycle energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most elderly Finnish residents prefer to age in place, but some relocate because of push factors that create stress in their current homes and pull factors that attract them to a new dwelling. This survey examines the important pull factors that attract seniors to senior houses. Grocery nearby is the strongest pull factor followed by hospital or medical center and public transportation. A factor analysis reveals that attributes can be grouped into three factors: onsite services that allow the residents to maintain an active lifestyle with some luxury, everyday services and facilities that would enable aging in place, and physical activity facilities. Residents have chosen the type of senior housing that supports their lifestyle. Meanwhile, socioeconomic characteristics do not explain the differences in the types of features that attract residents.