976 resultados para HIERARCHICAL CONTROL
Resumo:
An approach is presented for hierarchical control of an ammonia reactor, which is a key unit process in a nitrogen fertilizer complex. The aim of the control system is to ensure safe operation of the reactor around the optimal operating point in the face of process variable disturbances and parameter variations. The four different layers perform the functions of regulation, optimization, adaptation, and self-organization. The simulation for this proposed application is conducted on an AD511 hybrid computer in which the AD5 analog processor is used to represent the process and the PDP-11/ 35 digital computer is used for the implementation of control laws. Simulation results relating to the different layers have been presented.
Resumo:
Based on integrated system optimisation and parameter estimation a method is described for on-line steady state optimisation which compensates for model-plant mismatch and solves a non-linear optimisation problem by iterating on a linear - quadratic representation. The method requires real process derivatives which are estimated using a dynamic identification technique. The utility of the method is demonstrated using a simulation of the Tennessee Eastman benchmark chemical process.
Resumo:
Mode of access: Internet.
Resumo:
Purpose – The purpose of this paper is to consider hierarchical control as a mode of governance, and analyses the extent of control exhibited by central government over local government through the best value (BV) and comprehensive performance assessment (CPA) performance regimes. Design/methodology/approach – This paper utilises Ouchi's framework and, specifically, his articulation of bureaucratic or hierarchical control in the move towards achievement of organisational objectives. Hierarchical control may be inferred from the extent of “command and control” by Central Government, use of rewards and sanctions, and alignment to government priorities and discrimination of performance. Findings – CPA represents a more sophisticated performance regime than BV in the governance of local authorities by central government. In comparison to BV, CPA involved less scope for dialogue with local government prior to introduction, closer inspection of and direction of support toward poorer performing authorities, and more alignment to government priorities in the weightings attached to service blocks. Originality/value - The paper focuses upon the hierarchic/bureaucratic mode of governance as articulated by Ouchi and expands on this mode in order to analyse shifts in performance regimes in the public sector.
Resumo:
To minimise the number of load sheddings in a microgrid (MG) during autonomous operation, islanded neighbour MGs can be interconnected if they are on a self-healing network and an extra generation capacity is available in the distributed energy resources (DER) of one of the MGs. In this way, the total load in the system of interconnected MGs can be shared by all the DERs within those MGs. However, for this purpose, carefully designed self-healing and supply restoration control algorithm, protection systems and communication infrastructure are required at the network and MG levels. In this study, first, a hierarchical control structure is discussed for interconnecting the neighbour autonomous MGs where the introduced primary control level is the main focus of this study. Through the developed primary control level, this study demonstrates how the parallel DERs in the system of multiple interconnected autonomous MGs can properly share the load of the system. This controller is designed such that the converter-interfaced DERs operate in a voltage-controlled mode following a decentralised power sharing algorithm based on droop control. DER converters are controlled based on a per-phase technique instead of a conventional direct-quadratic transformation technique. In addition, linear quadratic regulator-based state feedback controllers, which are more stable than conventional proportional integrator controllers, are utilised to prevent instability and weak dynamic performances of the DERs when autonomous MGs are interconnected. The efficacy of the primary control level of the DERs in the system of multiple interconnected autonomous MGs is validated through the PSCAD/EMTDC simulations considering detailed dynamic models of DERs and converters.
Resumo:
This paper proposes a hierarchical energy management system for multi-source multi-product (MSMP) microgrids. Traditional energy hub based scheduling method is combined with a hierarchical control structure to incorporate transient characteristics of natural gas flow and dynamics of energy converters in microgrids. The hierarchical EMS includes a supervisory control layer, an optimizing control layer, and an execution control layer. In order to efficiently accommodate the systems multi time-scale characteristics, the optimizing control layer is decomposed into three sub-layers: slow, medium and fast. Thermal, gas and electrical management systems are integrated into the slow, medium, and fast control layer, respectively. Compared with wind energy, solar energy is easier to integrate and more suitable for the microgrid environment, therefore, potential impacts of the hierarchical EMS on MSMP microgrids is investigated based on a building energy system integrating photovoltaic and microturbines. Numerical studies indicate that by using a hierarchical EMS, MSMP microgrids can be economically operated. Also, interactions among thermal, gas, and electrical system can be effectively managed.
Resumo:
An indoor rowing machine has been modified for functional electrical stimulation (FES) assisted rowing exercise in paraplegia. To perform the rowing manoeuvre successfully, however, the voluntarily controlled upper body movements must be co-ordinated with the movements of the electrically stimulated paralysed legs. To achieve such co-ordination, an automatic FES controller was developed that employs two levels of hierarchy. At the upper level, a finite state controller identifies the state or phase of the rowing cycle and activates the appropriate lower-level controller, in which electrical stimulation to the paralysed leg muscles is applied with reference to switching curves representing the desired seat velocity as a function of the seat position. In a pilot study, the hierarchical control of FES rowing was shown to be intuitive, reliable and easy to use. Compared with open-loop control of stimulation, all three variants of the closed-loop switching curve controllers used less muscle stimulation per rowing cycle (73% of the open-loop control on average). Further, the closed-loop controller that used switching curves derived from normal rowing kinematics used the lowest muscle stimulation (65% of the open-loop control) and was the most convenient to use for the client.
Resumo:
This paper proposes a reward based demand response algorithm for residential customers to shave network peaks. Customer survey information is used to calculate various criteria indices reflecting their priority and flexibility. Criteria indices and sensitivity based house ranking is used for appropriate load selection in the feeder for demand response. Customer Rewards (CR) are paid based on load shift and voltage improvement due to load adjustment. The proposed algorithm can be deployed in residential distribution networks using a two-level hierarchical control scheme. Realistic residential load model consisting of non-controllable and controllable appliances is considered in this study. The effectiveness of the proposed demand response scheme on the annual load growth of the feeder is also investigated. Simulation results show that reduced peak demand, improved network voltage performance, and customer satisfaction can be achieved.
Resumo:
In order to minimize the number of load shedding in a Microgrid during autonomous operation, islanded neighbour microgrids can be interconnected if they are on a self-healing network and an extra generation capacity is available in Distributed Energy Resources (DER) in one of the microgrids. In this way, the total load in the system of interconnected microgrids can be shared by all the DERs within these microgrids. However, for this purpose, carefully designed self-healing and supply restoration control algorithm, protection systems and communication infrastructure are required at the network and microgrid levels. In this chapter, first a hierarchical control structure is discussed for interconnecting the neighbour autonomous microgrids where the introduced primary control level is the main focus. Through the developed primary control level, it demonstrates how the parallel DERs in the system of multiple interconnected autonomous microgrids can properly share the load in the system. This controller is designed such that the converter-interfaced DERs operate in a voltage-controlled mode following a decentralized power sharing algorithm based on droop control. The switching in the converters is controlled using a linear quadratic regulator based state feedback which is more stable than conventional proportional integrator controllers and this prevents instability among parallel DERs when two microgrids are interconnected. The efficacy of the primary control level of DERs in the system of multiple interconnected autonomous microgrids is validated through simulations considering detailed dynamic models of DERs and converters.
Resumo:
针对异构多UUV协作任务,提出了基于多智能体系统的分层式体系结构(MAHA).在个体层面,将UUV智能体的思维状态分为社会心智和个体心智两个层次分别实现,更加符合人类社会协作模式;在群体层面,提出了复杂海洋环境下UUV群体结构的评价准则,并据此将MAHA与现有结构进行了对比分析.此外,利用面向对象的Petri网理论建立了系统的协作模型,有效降低了系统建模的复杂性.最后,水下多目标搜索使命的实例研究表明,MAHA能够保证异构UUV之间进行有效的协作.
Resumo:
系统的决策控制活动依赖于系统内部的控制结构,制造系统的控制结构是先进制造与自动化领域的重要研究课题。制造系统的控制结构与计算机技术、生产设备自动化水平及制造模式等因素有关。早期的制造系统采用集中控制结构,而柔性制造系统和计算机集成制造系统多采用递阶控制结构。目前制造业已进入一个新时代,传统生产模式和企业结构无法适应不可预测的激烈的环境变化。因此,未来制造系统需要具备快速变化能力的动态控制结构
Resumo:
本文首先论述了体系结构对大型自动化系统开发的重要意义,接着从生命周期的观点、递阶控制的观点、自控系统组成三要素的观点对体系结构进行了竖向、纵向、横向的分析。并讨论了各类参考模型对支持平台的要求,最后提出了大型过程工业自动化全过程体系结构,该体系结构对“八·五”攻关课题“大型过程工业综合自动化总体技术”具有指导作用。
Resumo:
In this paper, a new scheduling algorithm for the flexible manufacturing cell is presented, which is a discrete time control method with fixed length control period combining with event interruption. At the flow control level we determine simultaneously the production mix and the proportion of parts to be processed through each route. The simulation results for a hypothetical manufacturing cell are presented.
Resumo:
本文基于递阶控制原理提出了柔性制造单元的一种新的计划与调度方法,并综合采用了理论分析、专家系统技术和仿真技术,建立了一个智能调度系统原型.另外,在制造单元调度问题的描述上采用了状态方程形式,从系统的观点来研究调度问题.并在此基础上建立了仿真模块,对单元的加工过程进行了仿真实验.
Resumo:
现有的机器人自适应控制基本上都是在建立机器人线性化的动力学模型的基础上,采用某种显式或隐式参数辨识的方法,在线地修正控制作用.本文针对机器人运动和动力学参数变化的固有特点,提出一种完全不同的自学习自适应方法.这种方法基于智能机器人分级系统中的两级结构,并且在空间域里而不是在时间域里处理机器人参数的变化.把机器人的作业空间划分成子空间,其中包括重力载荷的作用,每个子空间对应一组控制器.规划的轨迹映射到作业空间形成子空间序列.用自学习方法选择与这个序列对应的最佳控制器序列.该方法算法简单,计算量小.避开了通常的自适应方法遇到的一系列困难问题.