965 resultados para HEIDELBERG-RETINA-TOMOGRAPH


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the reproducibility of optic disk measurements provided by an image analyzer and a scanning laser tomograph. Methods: Ten images of the same eye of 10 normal volunteers were taken with the Heidelberg Retina Tomograph and with the Topcon ImageNet. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were used to evaluate the reproducibility of the measurements. Results: Eleven parameters were analyzed with the Topcon ImageNet. Six parameters (55%) had ICC greater than 90%. Four parameters (36%) had CV less than 10%. Twelve parameters were evaluated with the Heidelberg Retina Tomograph. Nine parameters (75%) had ICC over 90%. Nine parameters (75%) had CV less than 10%. Conclusion: Both systems provided reproducible data. The optic disk parameters provided by the Heidelberg Retina Tomograph had a better reproducibility than those obtained from the Topcon ImageNet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To detect and quantitate changes in optic nerve morphology after glaucoma surgery using the Heidelberg Retina Tomograph (HRT, Heidelberg Instruments, Heidelberg, Germany). Design: Nonconsecutive observational case series. Participants and Intervention: The authors prospectively enrolled 21 adult patients undergoing incisional glaucoma surgery for progressive glaucoma damage. Quantitative analysis of the optic nerve head by scanning laser tomography and automated perimetry were performed before and after glaucoma surgery. Main Outcome Measures: Changes in optic nerve parameters were subjected to linear regression analysis with respect to percent of postoperative reduction of intraocular pressure (IOP), as well as with respect to age, refraction, preoperative cup:disc ratio, and change in visual field parameters. Results: Seventeen patients had pre- and postoperative images suitable for analysis. Mean IOP at the time of image acquisition before surgery was 30.5 ± 12 mmHg, and after surgery 11.8 ± 5.2 mmHg (mean follow-up, 26 ± 7 weeks). Eleven of 13 (85%) patients having IOP reduction of greater than 40% showed improvement in optic disc parameters. All four patients with less than 25% reduction in IOP showed worsening of most parameters. Changes in optic disc parameters were highly correlated with percent IOP reduction and with age. The parameters in which change most strongly correlated with percent change of IOP were cup area, rim area, cup:disc ratio, and mean cup depth (each, P <0.005). The age of the patient correlated highly with change in maximum cup depth (P <0.005). Refraction and clinically determined cup:disc ratio correlated poorly with changes in measured optic disc parameters. Clinical improvement in visual fields was correlated with the degree of improvement of cup:disc ratio (P = 0.025). Conclusion: Most patients showing a 40% lowering of IOP after glaucoma surgery show improved optic nerve morphology as measured by the HRT. The amount of improvement correlated highly with the percent reduction of IOP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To analyze the repeatability of measuring nerve fiber length (NFL) from images of the human corneal subbasal nerve plexus using semiautomated software. Methods: Images were captured from the corneas of 50 subjects with type 2 diabetes mellitus who showed varying severity of neuropathy, using the Heidelberg Retina Tomograph 3 with Rostock Corneal Module. Semiautomated nerve analysis software was independently used by two observers to determine NFL from images of the subbasal nerve plexus. This procedure was undertaken on two occasions, 3 days apart. Results: The intraclass correlation coefficient values were 0.95 (95% confidence intervals: 0.92–0.97) for individual subjects and 0.95 (95% confidence intervals: 0.74–1.00) for observer. Bland-Altman plots of the NFL values indicated a reduced spread of data with lower NFL values. The overall spread of data was less for (a) the observer who was more experienced at analyzing nerve fiber images and (b) the second measurement occasion. Conclusions: Semiautomated measurement of NFL in the subbasal nerve fiber layer is highly repeatable. Repeatability can be enhanced by using more experienced observers. It may be possible to markedly improve repeatability when measuring this anatomic structure using fully automated image analysis software.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Corneal confocal microscopy is a novel diagnostic technique for the detection of nerve damage and repair in a range of peripheral neuropathies, in particular diabetic neuropathy. Normative reference values are required to enable clinical translation and wider use of this technique. We have therefore undertaken a multicenter collaboration to provide worldwide age-adjusted normative values of corneal nerve fiber parameters. RESEARCH DESIGN AND METHODS A total of 1,965 corneal nerve images from 343 healthy volunteers were pooled from six clinical academic centers. All subjects underwent examination with the Heidelberg Retina Tomograph corneal confocal microscope. Images of the central corneal subbasal nerve plexus were acquired by each center using a standard protocol and analyzed by three trained examiners using manual tracing and semiautomated software (CCMetrics). Age trends were established using simple linear regression, and normative corneal nerve fiber density (CNFD), corneal nerve fiber branch density (CNBD), corneal nerve fiber length (CNFL), and corneal nerve fiber tortuosity (CNFT) reference values were calculated using quantile regression analysis. RESULTS There was a significant linear age-dependent decrease in CNFD (-0.164 no./mm(2) per year for men, P < 0.01, and -0.161 no./mm(2) per year for women, P < 0.01). There was no change with age in CNBD (0.192 no./mm(2) per year for men, P = 0.26, and -0.050 no./mm(2) per year for women, P = 0.78). CNFL decreased in men (-0.045 mm/mm(2) per year, P = 0.07) and women (-0.060 mm/mm(2) per year, P = 0.02). CNFT increased with age in men (0.044 per year, P < 0.01) and women (0.046 per year, P < 0.01). Height, weight, and BMI did not influence the 5th percentile normative values for any corneal nerve parameter. CONCLUSIONS This study provides robust worldwide normative reference values for corneal nerve parameters to be used in research and clinical practice in the study of diabetic and other peripheral neuropathies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims. To evaluate the effect of acute elevation of intraocular pressure (IOP) on optic disc cupping. Methods. 10 emmetropic and 10 myopic volunteers were included in this study. The cup area (CA) and cup volume (CV) of the optic disc were determined with the Heidelberg retina tomograph (HRT). After baseline determinations, a suction cup was used to increase the intraocular pressure (IOP) to 20-25 mmHg above the baseline and HRT images were obtained. Results. Baseline IOP was 13.5 (SD 1.3) mmHg and 12.6 (2.6) mmHg in the emmetropic and myopic groups, respectively. The IOP was elevated to 35.4 (3.3) mmHg and 34.4 (2.5) mmHg in the emmetropic and myopic groups, respectively. When compared with their baseline values, the cupping variables (CA and CV) were significantly increased (p <0.05) during the suction treatment in both emmetropic and myopic subjects. Conclusion. There was a significant enlargement in the optic disc cupping during the artificial increment of intraocular pressure in both emmetropic and myopic eyes. In non-glaucomatous eyes the optic nerve head has a partially dynamic topography dependent upon the level of IOP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The authors estimated the retinal nerve fiber layer height (RNFLH) measurements in patients with glaucoma compared with those in age-matched healthy subjects as obtained by the laser scanning tomography and assessed the relationship between RNFLH measurements and optic and visual field status. Methods: Parameters of optic nerve head topography and RNFLH were evaluated in 125 eyes of 21 healthy subjects and 104 patients with glaucoma using the Heidelberg Retina Tomograph ([HRT] Heidelberg Engineering GmbH, Heidelberg, Germany) for the entire disc area and for the superior 70°(50°temporal and 20°nasal to the vertical midline) and inferior 70°sectors of the optic disc. The mean deviation of the visual field, as determined by the Humphrey program 24-2 (Humphrey Instruments, Inc., San Leonardo, CA, U.S.A) was calculated in the entire field and in the superior and inferior Bjerrum area. Result: Retinal nerve fiber layer height parameters (mean RNFLH and RNFL cross-sectional area) were decreased significantly in patients with glaucoma compared with healthy individuals. Retinal nerve fiber layer height parameters was correlated strongly with rim volume, rim area, and cup/disc area ratio. Of the various topography measures, retinal nerve fiber layer (RNFL) parameters and cup/disc area ratio showed the strongest correlation with visual field mean deviation in patients with glaucoma. Conclusion: Retinal nerve fiber layer height measures were reduced substantially in patients with glaucoma compared with age-matched healthy subjects. Retinal nerve fiber layer height was correlated strongly with topographic optic disc parameters and visual field changes in patients with glaucoma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/aim: Structural changes in the lamina cribrosa have been implicated in the pathogenesis of glaucomatous optic atrophy. The aim of this study was to determine a measure the surface variability of the cup floor in normal subjects and patients with glaucoma. Methods: A sample of age matched normal subjects (NN), patients with low tension glaucoma (LTG), and primary open angle glaucoma (POAG) were included in the study. The glaucoma groups were matched for the severity of the visual field loss. Mean 10 degree topographic images of normal and glaucomatous eyes from the Heidelberg retina tomograph were imported into ERDAS image processing software where topographic analysis of the cup floor could be assessed. Each image was processed using customised spatial filters that calculated the surface depth variation in localised neighbourhood areas across each image. The local change in depth across the cup floor surface was determined and compared between the three clinical groups. Results: The depth variation in the cup floor was largest in normal subjects followed by LTG and POAG. Highly statistically significant differences in surface depth variability of the cup floor existed between normal and LTG (p=0.005), between normal and POAG (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cette thèse constitue à la fois un apport de nature clinique et technologique dans l’approche diagnostique du glaucome. Plus précisément, nous nous proposons d’étudier une nouvelle façon de détecter le glaucome par la mesure de l’asymétrie du rapport de la surface de l’anneau neurorétinien et de la surface de la papille ou du disque optique ou rim to disc area asymmetry ratio (RADAAR). Pour atteindre cet objectif, nous avons recours à une base de données composée d’une population subdivisée en 4 différents groupes de diagnostic (normal, glaucome possible, glaucome probable et glaucome définitif). Les mesures du RADAAR sont calculées de différentes façons à partir des paramètres stéréométriques de la tête du nerf optique des sujets, produits par la microscopie confocale à balayage laser (Heidelberg Retina Tomograph (HRT) (Heidelberg Engineering, Germany)). Nous procédons à une analyse de données grâce au logiciel SPSS où nous mettons en exergue la distribution du RADAAR dans les différentes populations, sa validité et son utilité dans le dépistage du glaucome. Nous enrôlons donc 523 sujets dans cette étude avec 82 sujets atteints de glaucome définitif. La moyenne d’âge est de 62 ans. Il y a plus de femmes que d’hommes et plus de Caucasiens que d’Africains Caribéens. Nous trouvons que la distribution de la mesure du RADAAR est différente des sujets d’un groupe de diagnostic à l’autre. En termes de performance, la sensibilité de la mesure du RADAAR est très basse c'est-à-dire que sa capacité de détecter la maladie est basse. En revanche la mesure du RADAAR est plus spécifique c'est-à-dire que sa capacité d’identifier les sujets exempts de la maladie est plus grande. Elle tendrait à être aussi plus performante chez les Africains Caribéens que chez les Caucasiens. De même, elle serait plus sensible chez les hommes que chez les femmes. La mesure du RADAAR est utile si on l’associe à une autre méthode de diagnostic comme l’analyse de Régression de Moorfields (MRA) incluse dans le logiciel du HRT3 spécialement lors de la détection du glaucome dans la population à haut risque. En définitive, nous déterminons que la mesure du RADAAR se veut un outil d’aide au diagnostic. Elle est particulièrement intéressante dans le contexte de dépistage de glaucome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. We previously demonstrated that most eyes have regionally variable extensions of Bruch's membrane (BM) inside the clinically identified disc margin (DM) that are clinically and photographically invisible. We studied the impact of these findings on DM- and BM opening (BMO)-derived neuroretinal rim parameters. METHODS. Disc stereo-photography and spectral domain optical coherence tomography (SD-OCT, 24 radial B-scans centered on the optic nerve head) were performed on 30 glaucoma patients and 10 age-matched controls. Photographs were colocalized to SD-OCT data such that the DM and BMO could be visualized in each B-scan. Three parameters were computed: (1) DM-horizontal rim width (HRW), the distance between the DM and internal limiting membrane (ILM) along the DM reference plane; (2) BMO-HRW, the distance between BMO and ILM along the BMO reference plane; and (3) BMO-minimum rim width (MRW), the minimum distance between BMO and ILM. Rank-order correlations of sectors ranked by rim width and spatial concordance measured as angular distances between equivalently ranked sectors were derived. RESULTS. The average DM position was external to BMO in all quadrants, except inferotemporally. There were significant sectoral differences among all three rim parameters. DM- HRW and BMO-HRW sector ranks were better correlated (median rho = 0.84) than DM- HRW and BMO-MRW (median rho = 0.55), or BMO-HRW and BMO-MRW (median rho = 0.60) ranks. Sectors with the narrowest BMO-MRW were infrequently the same as those with the narrowest DM-HRW or BMO-HRW. CONCLUSIONS. BMO-MRW quantifies the neuroretinal rim from a true anatomical outer border and accounts for its variable trajectory at the point of measurement. (Invest Ophthalmol Vis Sci. 2012;53:1852-1860) DOI:10.1167/iovs.11-9309

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the rate of visual field and optic disc change in patients with distinct patterns of glaucomatous optic disc damage. Design: Prospective longitudinal study. Participants: A total of 131 patients with open-angle glaucoma with focal (n = 45), diffuse (n = 42), and sclerotic (n = 44) optic disc damage. Methods: Patients were examined every 4 months with standard automated perimetry (SAP, SITA Standard, 24-2 test, Humphrey Field Analyzer, Carl Zeiss Meditec, Dublin, CA) and confocal scanning laser tomography (CSLT, Heidelberg Retina Tomograph, Heidelberg Engineering GmbH, Heidelberg, Germany) for a period of 4 years. During this time, patients were treated according to a predefined protocol to achieve a target intraocular pressure (IOP). Rates of change were estimated by robust linear regression of visual field mean deviation (MD) and global optic disc neuroretinal rim area with follow-up time. Main Outcome Measures: Rates of change in MD and rim area. Results: Rates of visual field change in patients with focal optic disc damage (mean -0.34, standard deviation [SD] 0.69 dB/year) were faster than in patients with sclerotic (mean - 0.14, SD 0.77 dB/year) and diffuse (mean + 0.01, SD 0.37 dB/year) optic disc damage (P = 0.003, Kruskal-Wallis). Rates of optic disc change in patients with focal optic disc damage (mean - 11.70, SD 25.5 x 10(-3) mm(2)/year) were faster than in patients with diffuse (mean -9.16, SD 14.9 x 10(-3) mm(2)/year) and sclerotic (mean -0.45, SD 20.6 x 10(-3) mm(2)/year) optic disc damage, although the differences were not statistically significant (P = 0.11). Absolute IOP reduction from untreated levels was similar among the groups (P = 0.59). Conclusions: Patients with focal optic disc damage had faster rates of visual field change and a tendency toward faster rates of optic disc deterioration when compared with patients with diffuse and sclerotic optic disc damage, despite similar IOP reductions during follow-up. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012; 119: 294-303 (C) 2012 by the American Academy of Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: To compare morphometric parameters and diagnostic performance of the new Stratus Optical Coherence Tomograph (OCT) Disc mode and the Heidelberg Retina Tomograph (HRT); to evaluate OCT's accuracy in determining optic nerve head (ONH) borders. METHODS: Controls and patients with ocular hypertension, glaucoma-like discs, and glaucoma were imaged with OCT Disc mode, HRT II, and colour disc photography (DISC-PHOT). In a separate session, automatically depicted ONH shape and size in OCT were compared with DISC-PHOT, and disc borders adjusted manually where required. In a masked fashion, all print-outs and photographs were studied and discs classified as normal, borderline, and abnormal. The Cohen kappa method was then applied to test for agreement of classification. Bland-Altman analysis was used for comparison of disc measures. RESULTS: In all, 49 eyes were evaluated. Automated disc margin recognition failed in 53%. Misplaced margin points were more frequently found in myopic eyes, but only 31/187 were located in an area of peripapillary atrophy. Agreement of OCT with photography-based diagnosis was excellent in normally looking ONHs, but moderate in discs with large cups, where HRT performed better. OCT values were consistently larger than HRT values for disc and cup area. Compared with HRT, small rim areas and volumes tended to be minimized by OCT, and larger ones to be magnified. CONCLUSIONS: Stratus OCT Disc protocol performed overall well in differentiating between normal and glaucomatous ONHs. However, failure of disc border recognition was frequently observed, making manual correction necessary. ONH measures cannot be directly compared between HRT and OCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND It has been suggested that sleep apnea syndrome may play a role in normal-tension glaucoma contributing to optic nerve damage. The purpose of this study was to evaluate if optic nerve and visual field parameters in individuals with sleep apnea syndrome differ from those in controls. PATIENTS AND METHODS From the records of the sleep laboratory at the University Hospital in Bern, Switzerland, we recruited consecutive patients with severe sleep apnea syndrome proven by polysomnography, apnea-hypopnea index >20, as well as no sleep apnea controls with apnea-hypopnea index <10. Participants had to be unknown to the ophtalmology department and had to have no recent eye examination in the medical history. All participants underwent a comprehensive eye examination, scanning laser polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, California), scanning laser ophthalmoscopy (Heidelberg Retina Tomograph II, HRT II), and automated perimetry (Octopus 101 Programm G2, Haag-Streit Diagnostics, Koeniz, Switzerland). Mean values of the parameters of the two groups were compared by t-test. RESULTS The sleep apnea group consisted of 69 eyes of 35 patients; age 52.7 ± 9.7 years, apnea-hypopnea index 46.1 ± 24.8. As controls served 38 eyes of 19 patients; age 45.8 ± 11.2 years, apnea-hypopnea index 4.8 ± 1.9. A difference was found in mean intraocular pressure, although in a fully overlapping range, sleep apnea group: 15.2 ± 3.1, range 8-22 mmHg, controls: 13.6 ± 2.3, range 9-18 mmHg; p<0.01. None of the extended visual field, optic nerve head (HRT) and retinal nerve fiber layer (GDx VCC) parameters showed a significant difference between the groups. CONCLUSION Visual field, optic nerve head, and retinal nerve fiber layer parameters in patients with sleep apnea did not differ from those in the control group. Our results do not support a pathogenic relationship between sleep apnea syndrome and glaucoma.