35 resultados para Gyroscopes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Els sistemes automatitzats que requereixen d’un control d’estabilitat o moviment es poden trobar cada cop en més àmbits. Aplicacions UAV o de posicionament global són les més comunes per aquest tipus de sistemes, degut a que necessiten d’un control de moviment molt precís. Per a dur a terme aquest procés s’utilitzen unitats de mesura inercial, que mitjançant acceleròmetres i giroscopis degudament posicionats, a més a més d’una correcció del possible error que puguin introduir aquests últims, proporcionen una acceleració i una velocitat angular de les quals es pot extreure el camí efectuat per aquestes unitats. La IMU, combinada amb un GPS i mitjançant un filtre de Kalman, proporcionen una major exactitud , a més d’un punt de partida (proporcionat per el GPS), un recorregut representable en un mapa y, en el cas de perdre la senyal GPS, poder seguir adquirint dades de la IMU. Aquestes dades poden ser recollides i processades per una FPGA, que a la vegada podem sincronitzar amb una PDA per a que l’usuari pugui veure representat el moviment del sistema. Aquest treball es centra en el funcionament de la IMU i l’adquisició de dades amb la FPGA. També introdueix el filtre de Kalman per a la correcció de l’error dels sensors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory setting and then tested on 31 healthy volunteer subjects while carrying the ambulatory system during 8 h of their daily life. For each recording, the periods of sitting, standing and walking during daily activity were detected using an inertial sensor attached on the chest. During each period of daily activity the type of arm movement (flexion, abduction, internal/external rotation) its velocity and frequency (number of movement/hour) were estimated. The results showed that during the whole daily activity and for each activity (i.e. walking, sitting and walking) the frequency of internal/external rotation was significantly higher while the frequency of abduction was the lowest (P < 0.009). In spite of higher number of flexion, abduction and internal/external rotation in the dominant arm, we have not observed in our population a significant difference with the non-dominant arm, implying that in healthy subjects the arm dominance does not lie considerably on the number of movements. As expected, the frequency of the movement increased from sitting to standing and from standing to walking, while we provide a quantitative value of this change during daily activity. This study provides preliminary evidence that this system is a useful tool for objectively assessing upper-limb activity during daily activity. The results obtained with the healthy population could be used as control data to evaluate arm movement of patients with shoulder diseases during daily activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Quantification of daily upper-limb activity is determinant in the evaluation of shoulder surgery. For a number of shoulder diseases, roblems in performing daily activities have been expressed in terms of upper-limb usage. Althought many instruments measure upper-limb movements, there is no accepted standard or widely used objective measure and no device to differenciate left or right shoulder usage. We present an objective method to measure the mobility and quantify the usage of dominant and healthy or painfull shoulder movement during daily life. Methods: 12 patients with unilateral pathological shoulder (rotator cuff disease) are compared to 18 control subjects (10 right and 8 left handed). Both SST and DASH questionnaires were completed by each one. Three inertial miniature modules including triaxial gyroscopes and accelerometers were fixed on the dorsal side of both humerus, and on the thorax. An ambulatory datalogger have recorded the signals during one day. Results: We observed that right handed healthy subjects used 18% and 26% more their dominant shoulder during respectively stand and sit postures while left handed subjects used 8% and 18% more their left side. In walking periods, shoulder mobility was quite alike for both sides. Patients affected on their dominant arm (PD group) mostly used their non-dominant side (respectively 5% and 9% during stand and sit). For the patients affected on their non-dominant shoulder (PND group), this difference is respectively 28% and 26%. Moreover, we can note that, during walking periods, a difference can be observed (on the contrary to controls). Patients used 13% and 15% more their nonpathologic side respectively for PD and PND groups. Conclusion: Inertial sensors, during long-term ambulatory monitoring of upper limbs, can quantify the difference between dominant and nondominant sides. Patients used more their non affected shoulder during daily life. For the PD group, the difference with control can be shown during walking. These results are very encouraging for future evaluation of patients with shoulder injuries since it can provide an objective evaluation of the shoulder mobility and of the treatment outcome during daily life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: L'évaluation de la fonction de l'épaule à l'aide de capteurscinématiques embarqués produit des mesures discriminatives etsensibles au changement. Cependant, la réalisation pratique reste tropcomplexe pour l'utilisation courante. L'objectif de cette étude était dedévelopper une méthode d'évaluation cinématique simplifié et efficace.Méthode : Une analyse secondaire a été effectuée sur les donnéesd'un score de référence, basé sur la réalisation de 7 mouvements.Trente-cinq patients ont été mesurés à l'aide d'accéléromètreset de gyroscopes en préopératoire, ainsi qu'à 3, 6 et 12mois après chirurgie de l'épaule. Les mouvements essentiels ontété identifiés à l'aide une analyse en composantes principales(ACP). Une méthode d'évaluation simplifiée a ensuite été élaboréeen effectuant des régressions multiples des mouvementssélectionnées versus le score de référence à 3 mois. Les résultatsdu score simplifié ont été comparés au score de référence paranalyse statistique (ANOVA à mesure double répétées, régressionlinéaire, taille de l'effet, limite de l'agrément et corrélationaux échelles cliniques).Resultats : Une composante d'élévation et une composante de rotationreprésentant plus de 62 % de la variance ont été identifiées.Des modèles simplifiés d'évaluation ont donc été calculés avec desrégressions multiples incluant des combinaisons de mouvementsde rotation et d'élévation : dos-tête, dos-abduction, dos-épaule, dosplafond.La comparaison du score de référence et des scores simplifiésmontrait à tous les stades : une relation fortement linéaire (R2> 0,96), une taille de l'effet comparable (d de Cohen 1,33 à 1,51 versus1,33 pour le score de référence) et une corrélation comparable avecles scores cliniques (r = 0,22 à 0,8). La différence entre les scoresse situait entre - 6,28 et + 2,78. La limite de l'agrément variait de 13à 24 %. Parmi les scores simplifiés, seul le score « dos-plafond » nemontrait pas de différence avec le score de référence pour l'interactiontemps*score (p > 0,5).Discussion-Conclusion : Un score cinématique de l'épaule comprenantuniquement deux mouvements a été développé. Plusieursmodèles de score simplifiés produisent des résultats comparablesau score de référence pour l'évaluation de groupes de patients. Lescore moyen « dos-plafond » présente un profil d'évolution dans letemps en relation étroite avec le score de référence. Par contre, ladiscordance des résultats entre le score de référence et les scoressimplifiés lors de mesures individuelles doit être prise en considérationavant une éventuelle application à des études de cas clinique.Implications : Cette nouvelle méthode d'évaluation présente desavantages pratiques pour l'évaluation objective de l'épaule. Cecipourrait favoriser l'utilisation de méthodes d'analyse informatiséedu mouvement en clinique et pour la recherche. Les résultats confirmentégalement que l'on peut obtenir une bonne appréciation de lafonction de l'épaule en demandant au patient de mettre la main dansle dos, puis de lever le bras.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Variable definitions of outcome (Constant score, Simple Shoulder Test [SST]) have been used to assess outcome after shoulder treatment, although none has been accepted as the universal standard. Physicians lack an objective method to reliably assess the activity of their patients in dynamic conditions. Our purpose was to clinically validate the shoulder kinematic scores given by a portable movement analysis device, using the activities of daily living described in the SST as a reference. The secondary objective was to determine whether this device could be used to document the effectiveness of shoulder treatments (for glenohumeral osteoarthritis and rotator cuff disease) and detect early failures.Methods: A clinical trial including 34 patients and a control group of 31 subjects over an observation period of 1 year was set up. Evaluations were made at baseline and 3, 6, and 12 months after surgery by 2 independent observers. Miniature sensors (3-dimensional gyroscopes and accelerometers) allowed kinematic scores to be computed. They were compared with the regular outcome scores: SST; Disabilities of the Arm, Shoulder and Hand; American Shoulder and Elbow Surgeons; and Constant.Results: Good to excellent correlations (0.61-0.80) were found between kinematics and clinical scores. Significant differences were found at each follow-up in comparison with the baseline status for all the kinematic scores (P < .015). The kinematic scores were able to point out abnormal patient outcomes at the first postoperative follow-up.Conclusion: Kinematic scores add information to the regular outcome tools. They offer an effective way to measure the functional performance of patients with shoulder pathology and have the potential to detect early treatment failures.Level of evidence: Level II, Development of Diagnostic Criteria, Diagnostic Study. (C) 2011 Journal of Shoulder and Elbow Surgery Board of Trustees.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Psychomotor retardation is part of Major Depression (MD) diagnosis criteria and has been assimilated to bradykinesia, even though there is a clear lack of objective measurement of motor activity in MD. We conducted a study to evaluate bradykinesia, posture and gait parameters in MD patients with an ambulatory system, allowing continuous motor measurements. Methods: Patients with DSM-IV MD and healthy controls matched for age and sex were asked to carry on with their usual activities while being recorded for 6 hours by a wireless autonomous ambulatory system, containing miniature gyroscopes, data-logger, battery and flash memory. allowing continuous recording of upper limbs movements (speed, amplitude and activity (% of time with movement)), posture (% of time standing, walking, lying or sitting) and gait parameters (speed, cadence, stance, double support, stride). Results: Hands activity was significantly lower in depressed patients, as compared to controls (MD: 40%, controls: 60%; p<0.05). Speed of hand movements (p= 0.13) and their amplitude (p=0.71) were similar to controls. MD patients had a trend to spend more time lying or sitting than controls (p=0.06) but did not differ in terms of any gait parameters. Conclusion: Patients with MD displayed less hand movements than controls and tended to spend more time lying or sitting over 6 hours, but did not differ in terms of speed and amplitude of movement, nor in gait parameters. These results suggest that psychomotor retardation classically described in MD might be the expression of a paucity of movement rather than a bradykinesia as observed in parkinsonism and might involved different (nondopaminergic) mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gait analysis methods to estimate spatiotemporal measures, based on two, three or four gyroscopes attached on lower limbs have been discussed in the literature. The most common approach to reduce the number of sensing units is to simplify the underlying biomechanical gait model. In this study, we propose a novel method based on prediction of movements of thighs from movements of shanks. Datasets from three previous studies were used. Data from the first study (ten healthy subjects and ten with Parkinson's disease) were used to develop and calibrate a system with only two gyroscopes attached on shanks. Data from two other studies (36 subjects with hip replacement, seven subjects with coxarthrosis, and eight control subjects) were used for comparison with the other methods and for assessment of error compared to a motion capture system. Results show that the error of estimation of stride length compared to motion capture with the system with four gyroscopes and our new method based on two gyroscopes was close ( -0.8 ±6.6 versus 3.8 ±6.6 cm). An alternative with three sensing units did not show better results (error: -0.2 ±8.4 cm). Finally, a fourth that also used two units but with a simpler gait model had the highest bias compared to the reference (error: -25.6 ±7.6 cm). We concluded that it is feasible to estimate movements of thighs from movements of shanks to reduce number of needed sensing units from 4 to 2 in context of ambulatory gait analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Quantification of daily upper-limb activity is a key determinant in evaluation of shoulder surgery. For a number of shoulder diseases, problem in performing daily activities have been expressed in terms of upper-limb usage and non-usage. Many instruments measure upper-limb movement but do not focus on the differentiations between the use of left or right shoulder. Several methods have been used to measure it using only accelerometers, pressure sensors or video-based analysis. However, there is no standard or widely used objective measure for upper-limb movement. We report here on an objective method to measure the movement of upper-limb and we examined the use of 3D accelerometers and 3D gyroscopes for that purpose. Methods. We studied 8 subjects with unilateral pathological shoulder (8 rotator cuff disease: 53 years old ± 8) and compared them to 18 control subjects (10 right handed, 8 left handed: 32 years old ± 8, younger than the patient group to be almost sure they don_t have any unrecognized shoulder pathology). The Simple Shoulder Test (SST) and Disabilities of the Arm and Shoulder Score (DASH) questionnaires were completed by each subject. Two modules with 3 miniature capacitive gyroscopes and 3 miniature accelerometers were fixed by a patch on the dorsal side of the distal humerus, and one module with 3 gyroscopes and 3 accelerometers were fixed on the thorax. The subject wore the system during one day (8 hours), at home or wherever he/she went. We used a technique based on the 3D acceleration and the 3D angular velocities from the modules attached on the humerus. Results. As expected, we observed that for the stand and sit postures the right side is more used than the left side for a healthy right-handed person(idem on the left side for a healthy left-handed person). Subjects used their dominant upper-limb 18% more than the non-dominant upper-limb. The measurements on patients in daily life have shown that the patient has used more his non affected and non dominant side during daily activity if the dominant side = affected shoulder. If the dominant side affected shoulder, the difference can be showed only during walking period. Discussion-Conclusion. The technique developed and used allowed the quantification of the difference between dominant and non dominant side, affected and unaffected upper-limb activity. These results were encouraging for future evaluation of patients with shoulder injuries, before and after surgery. The feasibility and patient acceptability of the method using body fixed sensors for ambulatory evaluation of upper limbs kinematics was shown.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery