994 resultados para Guided Mastery Therapy
Pulse pressure variation-guided fluid therapy after cardiac surgery: A pilot before-and-after trial.
Resumo:
PURPOSE: The aim of this study is to study the feasibility, safety, and physiological effects of pulse pressure variation (PPV)-guided fluid therapy in patients after cardiac surgery. MATERIALS AND METHODS: We conducted a pilot prospective before-and-after study during mandatory ventilation after cardiac surgery in a tertiary intensive care unit. We introduced a protocol to deliver a fluid bolus for a PPV ≥13% for at least >10 minutes during the intervention period. RESULTS: We studied 45 control patients and 53 intervention patients. During the intervention period, clinicians administered a fluid bolus on 79% of the defined PPV trigger episodes. Median total fluid intake was similar between 2 groups during mandatory ventilation (1297 mL [interquartile range 549-1968] vs 1481 mL [807-2563]; P = .17) and the first 24 hours (3046 mL [interquartile range 2317-3982] vs 3017 mL [2192-4028]; P = .73). After adjusting for several baseline factors, PPV-guided fluid management significantly increased fluid intake during mandatory ventilation (P = .004) but not during the first 24 hours (P = .47). Pulse pressure variation-guided fluid therapy, however, did not significantly affect hemodynamic, renal, and metabolic variables. No serious adverse events were noted. CONCLUSIONS: Pulse pressure variation-guided fluid management was feasible and safe during mandatory ventilation after cardiac surgery. However, its advantages may be clinically small.
Resumo:
La radioterapia guidata da immagini (IGRT), grazie alle ripetute verifiche della posizione del paziente e della localizzazione del volume bersaglio, si è recentemente affermata come nuovo paradigma nella radioterapia, avendo migliorato radicalmente l’accuratezza nella somministrazione di dose a scopo terapeutico. Una promettente tecnica nel campo dell’IGRT è rappresentata dalla tomografia computerizzata a fascio conico (CBCT). La CBCT a kilovoltaggio, consente di fornire un’accurata mappatura tridimensionale dell’anatomia del paziente, in fase di pianificazione del trattamento e a ogni frazione del medisimo. Tuttavia, la dose da imaging attribuibile alle ripetute scansioni è diventata, negli ultimi anni, oggetto di una crescente preoccupazione nel contesto clinico. Lo scopo di questo lavoro è di valutare quantitativamente la dose addizionale somministrata da CBCT a kilovoltaggio, con riferimento a tre tipici protocolli di scansione per Varian OnBoard Imaging Systems (OBI, Palo Alto, California). A questo scopo sono state condotte simulazioni con codici Monte Carlo per il calcolo della dose, utilizzando il pacchetto gCTD, sviluppato sull’architettura della scheda grafica. L’utilizzo della GPU per sistemi server di calcolo ha permesso di raggiungere alte efficienze computazionali, accelerando le simulazioni Monte Carlo fino a raggiungere tempi di calcolo di ~1 min per un caso tipico. Inizialmente sono state condotte misure sperimentali di dose su un fantoccio d’acqua. I parametri necessari per la modellazione della sorgente di raggi X nel codice gCTD sono stati ottenuti attraverso un processo di validazione del codice al fine di accordare i valori di dose simulati in acqua con le misure nel fantoccio. Lo studio si concentra su cinquanta pazienti sottoposti a cicli di radioterapia a intensità modulata (IMRT). Venticinque pazienti con tumore al cervello sono utilizzati per studiare la dose nel protocollo standard-dose head e venticinque pazienti con tumore alla prostata sono selezionati per studiare la dose nei protocolli pelvis e pelvis spotlight. La dose media a ogni organo è calcolata. La dose media al 2% dei voxels con i valori più alti di dose è inoltre computata per ogni organo, al fine di caratterizzare l’omogeneità spaziale della distribuzione.
Resumo:
Magnetic resonance temperature imaging (MRTI) is recognized as a noninvasive means to provide temperature imaging for guidance in thermal therapies. The most common method of estimating temperature changes in the body using MR is by measuring the water proton resonant frequency (PRF) shift. Calculation of the complex phase difference (CPD) is the method of choice for measuring the PRF indirectly since it facilitates temperature mapping with high spatiotemporal resolution. Chemical shift imaging (CSI) techniques can provide the PRF directly with high sensitivity to temperature changes while minimizing artifacts commonly seen in CPD techniques. However, CSI techniques are currently limited by poor spatiotemporal resolution. This research intends to develop and validate a CSI-based MRTI technique with intentional spectral undersampling which allows relaxed parameters to improve spatiotemporal resolution. An algorithm based on autoregressive moving average (ARMA) modeling is developed and validated to help overcome limitations of Fourier-based analysis allowing highly accurate and precise PRF estimates. From the determined acquisition parameters and ARMA modeling, robust maps of temperature using the k-means algorithm are generated and validated in laser treatments in ex vivo tissue. The use of non-PRF based measurements provided by the technique is also investigated to aid in the validation of thermal damage predicted by an Arrhenius rate dose model.
Resumo:
The influence of respiratory motion on patient anatomy poses a challenge to accurate radiation therapy, especially in lung cancer treatment. Modern radiation therapy planning uses models of tumor respiratory motion to account for target motion in targeting. The tumor motion model can be verified on a per-treatment session basis with four-dimensional cone-beam computed tomography (4D-CBCT), which acquires an image set of the dynamic target throughout the respiratory cycle during the therapy session. 4D-CBCT is undersampled if the scan time is too short. However, short scan time is desirable in clinical practice to reduce patient setup time. This dissertation presents the design and optimization of 4D-CBCT to reduce the impact of undersampling artifacts with short scan times. This work measures the impact of undersampling artifacts on the accuracy of target motion measurement under different sampling conditions and for various object sizes and motions. The results provide a minimum scan time such that the target tracking error is less than a specified tolerance. This work also presents new image reconstruction algorithms for reducing undersampling artifacts in undersampled datasets by taking advantage of the assumption that the relevant motion of interest is contained within a volume-of-interest (VOI). It is shown that the VOI-based reconstruction provides more accurate image intensity than standard reconstruction. The VOI-based reconstruction produced 43% fewer least-squares error inside the VOI and 84% fewer error throughout the image in a study designed to simulate target motion. The VOI-based reconstruction approach can reduce acquisition time and improve image quality in 4D-CBCT.
Resumo:
Purpose: To develop, evaluate and apply a novel high-resolution 3D remote dosimetry protocol for validation of MRI guided radiation therapy treatments (MRIdian® by ViewRay®). We demonstrate the first application of the protocol (including two small but required new correction terms) utilizing radiochromic 3D plastic PRESAGE® with optical-CT readout.
Methods: A detailed study of PRESAGE® dosimeters (2kg) was conducted to investigate the temporal and spatial stability of radiation induced optical density change (ΔOD) over 8 days. Temporal stability was investigated on 3 dosimeters irradiated with four equally-spaced square 6MV fields delivering doses between 10cGy and 300cGy. Doses were imaged (read-out) by optical-CT at multiple intervals. Spatial stability of ΔOD response was investigated on 3 other dosimeters irradiated uniformly with 15MV extended-SSD fields with doses of 15cGy, 30cGy and 60cGy. Temporal and spatial (radial) changes were investigated using CERR and MATLAB’s Curve Fitting Tool-box. A protocol was developed to extrapolate measured ΔOD readings at t=48hr (the typical shipment time in remote dosimetry) to time t=1hr.
Results: All dosimeters were observed to gradually darken with time (<5% per day). Consistent intra-batch sensitivity (0.0930±0.002 ΔOD/cm/Gy) and linearity (R2=0.9996) was observed at t=1hr. A small radial effect (<3%) was observed, attributed to curing thermodynamics during manufacture. The refined remote dosimetry protocol (including polynomial correction terms for temporal and spatial effects, CT and CR) was then applied to independent dosimeters irradiated with MR-IGRT treatments. Excellent line profile agreement and 3D-gamma results for 3%/3mm, 10% threshold were observed, with an average passing rate 96.5%± 3.43%.
Conclusion: A novel 3D remote dosimetry protocol is presented capable of validation of advanced radiation treatments (including MR-IGRT). The protocol uses 2kg radiochromic plastic dosimeters read-out by optical-CT within a week of treatment. The protocol requires small corrections for temporal and spatially-dependent behaviors observed between irradiation and readout.
Resumo:
One reason for the neglect of the role of positive factors in cognitive-behavioural therapy (CBT) may relate to a failure to develop cognitive models that integrate positive and negative cognitions. Bandura [Psychol. Rev. 84 (1977) 191; Anxiety Res. 1 (1988) 77] proposed that self-efficacy beliefs mediate a range of emotional and behavioural outcomes. However, in panic disorder, cognitively based research to date has largely focused on catastrophic misinterpretation of bodily sensations. Although a number of studies support each of the predictions associated with the account of panic disorder that is based on the role of negative cognitions, a review of the literature indicated that a cognitively based explanation of the disorder may be considerably strengthened by inclusion of positive cognitions that emphasize control or coping. Evidence to support an Integrated Cognitive Model (ICM) of panic disorder was examined and the theoretical implications of this model were discussed in terms of both schema change and compensatory skills accounts of change processes in CBT. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
With the advances in terms of perfusion imaging, the "time is brain" approach used for acute reperfusion therapy in ischemic stroke patients is slowly being replaced by a "penumbra is brain" or "imaging is brain" approach. But the concept of penumbra-guided reperfusion therapy has not been validated. The lack of standardization in penumbral imaging is one of the main contributing factors for this absence of validation. This article reviews the issues underlying the lack of standardization of perfusion-CT for penumbra imaging, and offers avenues to remedy this situation
Resumo:
Fetoscopic coagulation of placental anastomoses is the treatment of choice for severe twin-to-twin transfusion syndrome. In the present day, fetal laser therapy is also used to treat amniotic bands, chorioangiomas, sacrococcygeal teratomas, lower urinary tract obstructions and chest masses, all of which will be reviewed in this article. Amniotic band syndrome can cause limb amputation by impairing downstream blood flow. Large chorioangiomas (>4 cm), sacrococcygeal teratomas or fetal hyperechoic lung lesions can lead to fetal compromise and hydrops by vascular steal phenomenon or compression. Renal damage, bladder dysfunction and lastly death because of pulmonary hypolasia may be the result of megacystis caused by a posterior urethral valve. The prognosis of these pathologies can be dismal, and therapy options are limited, which has brought fetal laser therapy to the forefront. Management options discussed here are laser release of amniotic bands, laser coagulation of the placental or fetal tumor feeding vessels and laser therapy by fetal cystoscopy. This review, largely based on case reports, does not intend to provide a level of evidence supporting laser therapy over other treatment options. Centralized evaluation by specialists using strict selection criteria and long-term follow-up of these rare cases are now needed to prove the value of endoscopic or ultrasound-guided laser therapy.
Resumo:
Hyperkalemia is a concern in heart failure (HF), especially in older patients with co-morbidities. Previous studies addressing this issue have focused mainly on younger patients. This study was aimed at determining the frequency and predictors of hyperkalemia in older patients with HF undergoing intense medical therapy. Frequency and predictors of hyperkalemia were defined in patients (n = 566) participating in the Trial of Intensified versus Standard Medical Therapy in Elderly Patients with Congestive Heart Failure, in which patients ≥60 years of age were randomized to a standard versus an intensified N-terminal brain natriuretic peptide-guided HF therapy. During an 18-month follow-up 76 patients (13.4%) had hyperkalemia (≥5.5 mmol/L) and 28 (4.9%) had severe hyperkalemia (≥6.0 mmol/L). Higher baseline serum potassium (odds ratio [OR] 2.92 per mmol/L), baseline creatinine (OR 1.11 per 10 μmol/L), gout (OR 2.56), New York Heart Association (NYHA) class (compared to NYHA class II, IV OR 3.08), higher dosage of spironolactone at baseline (OR 1.20 per 12.5 mg/day), and higher dose changes of spironolactone (compared to no dose change: 12.5 mg, OR 1.45; 25 mg, OR 2.52; >25 mg, OR 3.24) were independent predictors for development of hyperkalemia (p <0.05 for all comparisons). In conclusion, hyperkalemia is common in patients ≥60 years of age with HF undergoing intense medical therapy. Risk is increased in patients treated with spironolactone, in addition to patient-specific risk factors such as chronic kidney disease, higher serum potassium, advanced NYHA class, and gout. Careful surveillance of serum potassium and cautious use of spironolactone in patients at risk may help to decrease the incidence of potentially hazardous complications caused by hyperkalemia.
Resumo:
Purpose: The rapid distal falloff of a proton beam allows for sparing of normal tissues distal to the target. However proton beams that aim directly towards critical structures are avoided due to concerns of range uncertainties, such as CT number conversion and anatomy variations. We propose to eliminate range uncertainty and enable prostate treatment with a single anterior beam by detecting the proton’s range at the prostate-rectal interface and adaptively adjusting the range in vivo and in real-time. Materials and Methods: A prototype device, consisting of an endorectal liquid scintillation detector and dual-inverted Lucite wedges for range compensation, was designed to test the feasibility and accuracy of the technique. Liquid scintillation filled volume was fitted with optical fiber and placed inside the rectum of an anthropomorphic pelvic phantom. Photodiode-generated current signal was generated as a function of proton beam distal depth, and the spatial resolution of this technique was calculated by relating the variance in detecting proton spills to its maximum penetration depth. The relative water-equivalent thickness of the wedges was measured in a water phantom and prospectively tested to determine the accuracy of range corrections. Treatment simulation studies were performed to test the potential dosimetric benefit in sparing the rectum. Results: The spatial resolution of the detector in phantom measurement was 0.5 mm. The precision of the range correction was 0.04 mm. The residual margin to ensure CTV coverage was 1.1 mm. The composite distal margin for 95% treatment confidence was 2.4 mm. Planning studies based on a previously estimated 2mm margin (90% treatment confidence) for 27 patients showed a rectal sparing up to 51% at 70 Gy and 57% at 40 Gy relative to IMRT and bilateral proton treatment. Conclusion: We demonstrated the feasibility of our design. Use of this technique allows for proton treatment using a single anterior beam, significantly reducing the rectal dose.
Resumo:
This study investigated the role of both negative and positive cognitions in predicting panic severity in an international sample of patients diagnosed with panic disorder (with and without agoraphobia). One hundred and fifty-nine patients were administered the Brief Bodily Sensations Interpretation Questionnaire (BBSIQ), the Self-efficacy to Control Panic Attacks Questionnaire, and the Panic and Agoraphobia Scale (PAS) prior to receiving treatment. Regression analyses indicated that both catastrophic misinterpretation of bodily sensations and panic self-efficacy independently predicted panic severity. The influence of panic self-efficacy upon panic severity remained significant even after controlling for the presence or absence of agoraphobia. There was no evidence to suggest a moderating relationship between the two cognitive factors. Results are discussed in terms of the need to consider both negative and positive cognitions in cognitive accounts of panic disorder. (C) 2002 Elsevier Science Inc. All rights reserved.
Resumo:
Durante i trattamenti radioterapici dei pazienti oncologici testa-collo, le ghiandole parotidee (PGs) possono essere indebitamente irradiate a seguito di modificazioni volumetriche-spaziali inter/intra-frazione causate da fattori quali il dimagrimento, l’esposizione a radiazioni ionizzanti ed il morphing anatomico degli organi coinvolti nelle aree d’irraggiamento. Il presente lavoro svolto presso la struttura di Fisica Medica e di Radioterapia Oncologica dell’A.O.U di Modena, quale parte del progetto di ricerca del Ministero della Salute (MoH2010, GR-2010-2318757) “ Dose warping methods for IGRT and Adaptive RT: dose accumulation based on organ motion and anatomical variations of the patients during radiation therapy treatments ”, sviluppa un modello biomeccanico in grado di rappresentare il processo di deformazione delle PGs, considerandone la geometria, le proprietà elastiche e l'evoluzione durante il ciclo terapeutico. Il modello di deformazione d’organo è stato realizzato attraverso l’utilizzo di un software agli elementi finiti (FEM). Molteplici superfici mesh, rappresentanti la geometria e l’evoluzione delle parotidi durante le sedute di trattamento, sono state create a partire dai contorni dell’organo definiti dal medico radioterapista sull’immagine tomografica di pianificazione e generati automaticamente sulle immagini di setup e re-positioning giornaliere mediante algoritmi di registrazione rigida/deformabile. I constraints anatomici e il campo di forze del modello sono stati definiti sulla base di ipotesi semplificative considerando l’alterazione strutturale (perdita di cellule acinari) e le barriere anatomiche dovute a strutture circostanti. L’analisi delle mesh ha consentito di studiare la dinamica della deformazione e di individuare le regioni maggiormente soggette a cambiamento. Le previsioni di morphing prodotte dal modello proposto potrebbero essere integrate in un treatment planning system per metodiche di Adaptive Radiation Therapy.
Resumo:
A tenet of modern radiotherapy (RT) is to identify the treatment target accurately, following which the high-dose treatment volume may be expanded into the surrounding tissues in order to create the clinical and planning target volumes. Respiratory motion can induce errors in target volume delineation and dose delivery in radiation therapy for thoracic and abdominal cancers. Historically, radiotherapy treatment planning in the thoracic and abdominal regions has used 2D or 3D images acquired under uncoached free-breathing conditions, irrespective of whether the target tumor is moving or not. Once the gross target volume has been delineated, standard margins are commonly added in order to account for motion. However, the generic margins do not usually take the target motion trajectory into consideration. That may lead to under- or over-estimate motion with subsequent risk of missing the target during treatment or irradiating excessive normal tissue. That introduces systematic errors into treatment planning and delivery. In clinical practice, four-dimensional (4D) imaging has been popular in For RT motion management. It provides temporal information about tumor and organ at risk motion, and it permits patient-specific treatment planning. The most common contemporary imaging technique for identifying tumor motion is 4D computed tomography (4D-CT). However, CT has poor soft tissue contrast and it induce ionizing radiation hazard. In the last decade, 4D magnetic resonance imaging (4D-MRI) has become an emerging tool to image respiratory motion, especially in the abdomen, because of the superior soft-tissue contrast. Recently, several 4D-MRI techniques have been proposed, including prospective and retrospective approaches. Nevertheless, 4D-MRI techniques are faced with several challenges: 1) suboptimal and inconsistent tumor contrast with large inter-patient variation; 2) relatively low temporal-spatial resolution; 3) it lacks a reliable respiratory surrogate. In this research work, novel 4D-MRI techniques applying MRI weightings that was not used in existing 4D-MRI techniques, including T2/T1-weighted, T2-weighted and Diffusion-weighted MRI were investigated. A result-driven phase retrospective sorting method was proposed, and it was applied to image space as well as k-space of MR imaging. Novel image-based respiratory surrogates were developed, improved and evaluated.
Resumo:
Mestrado em Radioterapia.
Resumo:
Mestrado em Radioterapia.