67 resultados para Girders


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Flat Bed Rail Wagon (FBRW) has been proposed as an alternative solution for replacing bridges on low traffic volume roads. The subject matter for this paper is to investigate the impediment to load transfer from cross girders to main girder, through visually identifiable structural flaws. Namely, the effect of having large openings at close proximity to the connection of the main girder to the cross girder of a FBRW was examined. It was clear that openings locally reduce the section modulus of the secondary members; however it was unclear how these reductions would affect the load transfer to the main girder. The results are presented through modeling grillage action for which the loads applied onto the FBRW were distributed through cross girders to the main girder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents the results from an experimental program designed to evaluate the performance of a system consisting of a readout unit and a ribbon type Fiber Optic Sensor (FOS) based on Brillouin Optical Time Domain Analysis (BOTDA). The system is intended for the detection of cracks as well as the monitoring of long-term performance for steel bridge girders. The program consisted of introducing a crack at the center of a 3-m-long steel beam and monitoring its progression using static loading tests performed at ambient and sub-zero temperatures. For sensor lengths similar to those used in the field, the resonant frequency shifts per unit increase in crack width were found to decrease from 114 MHz/mm at ambient temperature (~25C) to 65 MHz/mm at -10C. Results also revealed nonlinearity and variability, which can be attributed to an incompatibility between the settings of the laser pump in the readout unit and the sensor length. Significant losses were detected along the bonded segments of the sensor and were attributed to the presence of ripples along the sensor. These undulations worsen with a reduction in temperature and are induced by the bonding procedure as well as the slack provided in the plastic sleeves containing the splices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental investigation of the shear strengths of composite plate girders, with centrally placed rectangular web cutouts, is described. A series of tests is conducted on short‐span girders having conventional welded stud shear connectors, connecting the composite concrete slabs to the top flanges of the plate girders. These tests indicated that it is the tensile or pullout capacity of the connectors that is primarily responsible for sustaining the composite action under predominantly shear loading. Subsequently, a further series of tests is conducted on short‐span girders with bolted tension connectors, designed to offer negligible resistance to horizontal shear forces at the interfaces between the concrete slabs and plate girders, which confirmed the previous conclusion. Both series of tests indicate that if adequate connectors are provided between a plate girder and a composite concrete slab, the shear strength of the composite girder is significantly higher than that of the plate girder alone. A simple analytical model for predicting the shear strengths of composite plate girders is also presented, which shows satisfactory correlation with the test results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For many years AASHTO provided no recommendation to state DOT’s on bottom flange confinement reinforcement for their bridge superstructures. The 1996 edition of AASHTO Standard Specification for Highway Bridges stated that nominal reinforcement be placed to enclose the prestressing steel from the end of the girder for at least a distance equal to the girder’s height. A few years later the 2004 AASHTO LRFD Bridge Design Specification changed the distance over which the confinement was to be distributed from 1.0h to 1.5h, and gave minimum requirements for the amount of steel to be used, No.3 bars, and their maximum spacing, not to exceed 6”. Research was undertaken to study what impact, if any, confinement reinforcement has on the performance of prestressed concrete bridge girders. Of particular interest was the effect confinement had on the transfer length, development length, and vertical shear capacity of the fore mentioned members. First, an analytical investigation was performed on the subject, and then an experimental investigation followed which consisted of designing, fabricating, and testing eight tee-girders and three NU1100 girders with particular attention paid to the amount and distribution of confinement reinforcement placed at the end of each girder. The results of the study show: 1) neither the amount or distribution of confinement reinforcement had a significant effect on the initial or final transfer length of the prestress strands; 2) at the AASHTO calculated development length, no significant impact from confinement was found on either the nominal flexural capacity of bridge girders or bond capacity of the prestressing steel; 3) the effects from varied confinement reinforcement on the shear resistance of girders tested was negligible, however, distribution of confinement did show to have an impact on the prestressed strands’ bond capacity; 4) confinement distribution across the entire girder did increase ductility and reduced cracking under extreme loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The folded plate girder, a newly proposed bridge girder, is investigated through this thesis. The folded plate girder is cold bent out of a single sheet of steel. The cold bending eliminates the costly and inconsistent shop welds found in traditional girders. The folded plate girder is meant for application in short span bridges. The girder was subjected to an equivalent 75 year lifetime loading to investigate the fatigue performance. The rebar detail used in the closure region between adjacent slabs has been investigated in the past by the NCHRP 12-68 project. This thesis will proposes a hooked rebar detail as a cost effective alternative to the previously recommended headed rebar detail. The proposed hooked rebar detail looks to improve upon the headed bar detail by increasing the clear cover, and reducing the cost of fabrication and shipment of the rebar. Six specimens containing closure regions are subjected to both positive and negative moment loading in order to investigate their behavior and failure modes under ultimate load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new steel girder bridge system was developed at the University of Nebraska. The innovative girder design is a box girder folded from a single steel plate that has a trapezoid shape with an opening on the bottom. The girder has application in short span bridges and accelerated construction situations. The structural performance of the girder requires investigation in all stages of a bridge’s lifecycle. This thesis contains descriptions and results from the first two tests from a series of tests developed to evaluate this new girder shape. The objective of these two tests was to investigate the constructability of the girders. During construction a bridge is in its least stable condition and it is important that the bridge components exhibit both adequate strength and stability during this critical stage. To this end, two girders were tested in flexure over a simple span as a non-composite beam simulating the loading the girders would be subjected to during construction. The results of the two tests indicate that the folded girder as a whole, and its components, provide adequate strength and stability at construction load levels. Failure occurred at loads that were above normal construction load levels and resulted in a ductile failure mode, which is a well documented benefit of steel components. The girders remained stable through all phases of loading including failure. The top flange was the weakest component of the beam during construction due to its role as a compression element that has a slender and un-braced form. The compression in the top flange caused local buckling in the top flange even at elastic load levels. This was the cause for loss of stiffness and failure in both specimens. Incorporation of a ridge at the center of the top flange of specimens, results of which are not reported in this thesis, proved to resolve this very early buckling issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"July 1986."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"HRDI-06/10-06(750)E"--Back cover.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preliminary considerations.--Single, web, box and beam girders.--Braced girders.--End carriages, wheels, axles and bearings.--Appendix: Approximate formulas for beams and crane girders, by C. R. Whittier.

Relevância:

20.00% 20.00%

Publicador: