999 resultados para Functional orthodontic appliances


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To assess objectively patient compliance with removable orthodontic appliances and the effect of possible influential factors. MATERIALS AND METHODS Wearing times of 45 White patients were recorded with the aid of the TheraMon microsensor. Patient compliance was assessed relative to wear prescription and other parameters, such as age and sex. RESULTS There was high individual variation in most measured variables and in all groups/subgroups. During a median observation period of 186 days (range, 55-318 days) the actual wear time was 9.0 h/d (range, 0.0-16.0 h/d) and did not differ between distinct prescriptions (P = .49). Eight patients wore their appliances less than 2 h/d, and six of them did not wear their appliances at all. Overall, the median wear per day relative to prescription was 62.5% (range, 0.0-89.3%) for the 14 h/d and 112.5% (range, 0.0-200.0%) for the 8 h/d prescription wear (P = .01) groups. There was a strong negative correlation of age (median: 12.5 years) with the daily percentage of actual wear time per day relative to wear prescription (14 h/d prescription: n = 21, rho = -0.61, P = .00; 8 h/d prescription: n = 24, rho = -0.73, P = .00), while sex did not exert a significant influence on compliance (P = .58). CONCLUSIONS Despite the fact that patients and parents were informed about wear time recording, compliance was insufficient with regard to functional treatment (14 h/d prescription), while it was sufficient for retention purposes (8 h/d prescription). Objective measures are necessary to assess compliance with removable orthodontic appliances since patient compliance is a highly variable issue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BackgroundAnterior open bite occurs when there is a lack of vertical overlap of the upper and lower incisors. the aetiology is multifactorial including: oral habits, unfavourable growth patterns, enlarged lymphatic tissue with mouth breathing. Several treatments have been proposed to correct this malocclusion, but interventions are not supported by strong scientific evidence.ObjectivesThe aim of this systematic review was to evaluate orthodontic and orthopaedic treatments to correct anterior open bite in children.Search methodsThe following databases were searched: the Cochrane Oral Health Group's Trials Register (to 14 February 2014); the Cochrane Central Register of Controlled Trials (CENTRAL)(The Cochrane Library 2014, Issue 1); MEDLINE via OVID (1946 to 14 February 2014); EMBASE via OVID (1980 to 14 February 2014); LILACS via BIREME Virtual Health Library (1982 to 14 February 2014); BBO via BIREME Virtual Health Library (1980 to 14 February 2014); and SciELO (1997 to 14 February 2014). We searched for ongoing trials via ClinicalTrials.gov (to 14 February 2014). Chinese journals were handsearched and the bibliographies of papers were retrieved.Selection criteriaAll randomised or quasi-randomised controlled trials of orthodontic or orthopaedic treatments or both to correct anterior open bite in children.Data collection and analysisTwo review authors independently assessed the eligibility of all reports identified.Risk ratios (RRs) and corresponding 95% confidence intervals (CIs) were calculated for dichotomous data. the continuous data were expressed as described by the author.Main resultsThree randomised controlled trials were included comparing: effects of Frankel's function regulator-4 (FR-4) with lip-seal training versus no treatment; repelling-magnet splints versus bite-blocks; and palatal crib associated with high-pull chincup versus no treatment.The study comparing repelling-magnet splints versus bite-blocks could not be analysed because the authors interrupted the treatment earlier than planned due to side effects in four of ten patients.FR-4 associated with lip-seal training (RR = 0.02 (95% CI 0.00 to 0.38)) and removable palatal crib associated with high-pull chincup (RR = 0.23 (95% CI 0.11 to 0.48)) were able to correct anterior open bite.No study described: randomisation process, sample size calculation, there was not blinding in the cephalometric analysis and the two studies evaluated two interventions at the same time. These results should be therefore viewed with caution.Authors' conclusionsThere is weak evidence that the interventions FR-4 with lip-seal training and palatal crib associated with high-pull chincup are able to correct anterior open bite. Given that the trials included have potential bias, these results must be viewed with caution. Recommendations for clinical practice cannot be made based only on the results of these trials. More randomised controlled trials are needed to elucidate the interventions for treating anterior open bite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adhesion and colonization of the oral cavity by Candida albicans is an initial step in candidosis. Orthodontic and other oral appliances seem to favor candidal presence. The aim of this work was to compare the presence of Candida species in saliva, their adherence to oral epithelial cells, and the levels of anti-C. albicans IgA in children with or without orthodontic appliances. This study included 30 children 5 to 12 years old (9.1 ± 1.7 years old) who were users of removable orthodontic devices for at least 6 months and 30 control children of similar ages (7.7 ± 1.5 years old). The presence of yeast species in the saliva was evaluated by microbiological methods. Candida species were identified using phenotypic methods. Anti-C. albicans IgA levels in saliva were analyzed by ELISA. The yeasts adhering to oral epithelial cells were assessed by exfoliative cytology. No statistically significant differences were observed for saliva yeast counts and anti-C. albicans IgA levels between the studied groups. Children with orthodontic devices exhibited more yeast cells adhering to oral epithelial cells and a higher percentage of non-albicans species relative to the control group. In conclusion, orthodontic appliances may favor the adherence of Candida to epithelial cells but do not influence the presence of these yeasts in saliva, and the levels of anti-C. albicans IgA do not correlate with yeast adherence or presence of Candida in the oral cavity

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To identify the timing of significant arch dimensional increases during orthodontic alignment involving round and rectangular nickel-titanium (NiTi) wires and rectangular stainless steel (SS). A secondary aim was to compare the timing of changes occurring with conventional and self-ligating fixed appliance systems. METHODS In this non-primary publication, additional data from a multicenter randomised trial initially involving 96 patients, aged 16 years and above, were analysed. The main pre-specified outcome measures were the magnitude and timing of maxillary intercanine, interpremolar, and intermolar dimensions. Each participant underwent alignment with a standard Damon (Ormco, Orange, CA) wire sequence for a minimum of 34 weeks. Blinding of clinicians and patients was not possible; however, outcome assessors and data analysts were kept blind to the appliance type during data analysis. RESULTS Complete data were obtained from 71 subjects. Significant arch dimensional changes were observed relatively early in treatment. In particular, changes in maxillary inter-first and second premolar dimensions occurred after alignment with an 0.014in. NiTi wire (P<0.05). No statistical differences in transverse dimensions were found between rectangular NiTi and working SS wires for each transverse dimension (P>0.05). Bracket type had no significant effect on the timing of the transverse dimensional changes. CONCLUSIONS Arch dimensional changes were found to occur relatively early in treatment, irrespective of the appliance type. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed. CLINICAL SIGNIFICANCE On the basis of this research orthodontic expansion may occur relatively early in treatment. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To evaluate the prevalence and hygiene habits of 13-19 years-old adolescent users of removable orthodontic appliances (ROA) and to determine hygiene methods for the appliances prescribed by dentists, in the city of Pelotas. Methods: The study had two stages. The first stage was a telephone interview with dentists. Dentists were interview by telephone calls in order to obtain information regarding the hygiene methods for cleaning acrylic appliances. Second stage was a cross-sectional study performed with schoolchildren. Children from public and private schools with secondary level were included in the sample. A questionnaire was applied to the students using any type of ROA. Questionnaires included demographic information and behavioral characteristics. Data collected were subjected to Chi-square test and logistic regression. Results: The prevalence of children using ROA was 5.4%. Students (89.7%) and dentists (47.2%) reported to prefer mechanical methods to clean their ROA. Cleaning with soup, hydrogen peroxide or effervescent tabs were less used. High frequency of use was associated with higher frequency of hygiene on the ROA. Conclusions: The prevalence of schoolchildren using removable appliances was low. The common cleaning method used by children and prescribed by dentists was mechanical. Hygiene frequency was significantly associated with the routine of use of the appliance and with the type of hygiene method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bite block is a functional orthodontic appliance that promotes relative intrusion or dental eruption inhibition. The purpose of this study is to present the effects of bite block on the treatment of an open bite case report.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the effects produced by the MARA appliance in the treatment of Angle’s Class II, division 1 malocclusion. Methods: The sample consisted of 44 young patients divided into two groups: The MARA Group, with initial mean age of 11.99 years, treated with the MARA appliance for an average period of 1.11 years, and the Control Group, with initial mean age of 11.63 years, monitored for a mean period of 1.18 years with no treatment. Lateral cephalograms were used to compare the groups using cephalometric variables in the initial and final phases. For these comparisons, Student’s t test was employed. Results: MARA appliance produced the following effects: Maxillary growth restriction, no change in mandibular development, improvement in maxillomandibular relationship, increased lower anterior facial height and counterclockwise rotation of the functional occlusal plane. In the upper arch, the incisors moved lingually and retruded, while the molars moved distally and tipped distally. In the lower arch, the incisors proclined and protruded, whereas the molars mesialized and tipped mesially. Finally, there was a significant reduction in overbite and overjet, with an obvious improvement in molar relationship. Conclusions: It was concluded that the MARA appliance proved effective in correcting Angle’s Class II, division 1 malocclusion while inducing skeletal changes and particularly dental changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O tratamento da má oclusão de Classe II sem extrações dentárias vem ganhando popularidade na comunidade ortodôntica já há três décadas. Aparelhos funcionais fixos vêm sendo utilizados por profissionais, de maneira crescente, para promover compensações dentoalveolares e corrigir a má oclusão de Classe II. Os efeitos mais significativos são observados em pacientes com padrão de crescimento horizontal. Um caso clínico será relatado com o uso do aparelho fixo Twin Force Bite Corrector em uma paciente do sexo feminino, para a correção da Classe II. Esse dispositivo de ancoragem fixa dispensa o uso de aparelhos funcionais removíveis e não necessita da cooperação do paciente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objtivo deste estudo pros

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to compare the dentoskeletal changes of patients with Class II Division 1 malocclusion treated with either the Jasper jumper appliance or the activator-headgear combination, both associated with fixed appliances. Methods: The sample comprised 72 subjects with Class II Division 1 malocclusion divided into 3 groups: group 1 included 25 subjects treated with fixed appliances and the force modules of the Jasper jumper at an initial mean age of 12.72 years, group 2 included 25 subjects treated with the activator-headgear combination followed by fixed appliances at an initial mean age of 11.07 years, and group 3 included 22 untreated subjects at an initial mean age of 12.67 years. Initial cephalometric characteristics and dentoskeletal changes were compared with analysis of variance. Results: Both experimental groups had similar dentoskeletal changes: restrictive effect on the maxilla, clockwise mandibular rotation and a slight increase in anterior face height, retrusion of the maxillary incisors, distalization of the maxillary molars, protrusion of the mandibular incisors, extrusion of the mandibular molars, and significant improvements of the maxillomandibular relationship, overjet, overbite, and the molar relationship. Conclusions: The effects of the Jasper jumper and the activator-headgear combination followed by fixed orthodontic appliances were similar in Class II malocclusion treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Fixed orthodontic appliances can alter the subgingival microbiota. Our aim was to compare the subgingival microbiota and clinical parameters in adolescent subjects at sites of teeth treated with orthodontic bands with margins at (OBM) or below the gingival margin (OBSM), or with brackets (OBR). METHODS: Microbial samples were collected from 33 subjects (ages, 12-18 years) in treatment more than 6 months. The microbiota was assessed by the DNA-DNA checkerboard hybridization method. RESULTS: Bacterial samples were taken from 83 OBR,103 OBSM, and 54 OBM sites. Probing pocket depths differed by orthodontic type (P <0.001) with mean values of 2.9 mm (SD, 0.6) at OBSM sites, 2.5 mm (SD, 0.6) at OBM sites, and 2.3 mm (SD, 0.5) at OBR sites. Only Actinomyces israelii (P <0.001) and Actinomyces naeslundii (P <0.001) had higher levels at OBR sites, whereas Neisseria mucosa had higher levels at sites treated with OBSM or OBM (P <0.001). Aggregatibacter actinomycetemcomitans was found in 25% of sites independent of the appliance. CONCLUSIONS: Different types of orthodontic appliances cause minor differences in the subgingival microbiota (A israelii and A naeslundii) and higher levels at sites treated with orthodontic brackets. More sites with bleeding on probing and deeper pockets were found around orthodontic bands.