993 resultados para Frequency ratio tuning
Resumo:
Department of Elecctronics, Cochin University of Science and Technology
Resumo:
A novel dual frequency dual-polarized square microstrip patch antenna embedded with a slot is presented. The proposed antenna offers tunability of the frequency ratio between the two frequencies by adjusting the slot dimensions. This configuration also provides a size reduction up to -51 and 35% for the two modes as compared to a square micro strip patch antenna
Resumo:
A novel reconfigurable, single feed, dual frequency, dualpolarized operation of a hexagonal slot-loaded square mwrostrip antenna is presented in this paper. A pin diode incorporated in the slot is used to switch the two operating frequencies considerably, without significantly affecting the radiation characteristics and gain. The proposed antenna provides a size reduction up to 61% and 26% Jor the two resonating frequencies, compared to standard rectangular patches. This design also gives considerable bandwidth up to 3.3% and 4.27%, for the two frequencies with a low operating frequency ratio
Resumo:
A novel design of a computer electronically reconfigurable dual frequency dual polarized single feed hexagonal slot loaded microstrip antenna in L-band is introduced in this chapter. pin diodes are used to switch the operating frequencies considerably without much affecting the radiation characteristics and gain. the antenna can work with a frequency ratio varying in the wide range from 1.2 to 1.4. the proposed design has an added advantage of size reduction up to 72.21% and 46.84% for the two resonating frequencies compared to standard rectangular patches. the design also gives considerable bandwidth of up to 2.82% and 2.42 % for the operating frequencies.
Resumo:
An orbital floating time scale of the Hauterivian-Barremian transition (Early Cretaceous) is proposed using high-resolution magnetic susceptibility measurements. Orbital tuning was performed on the Río Argos section (southeast Spain), the candidate for a Global boundary Stratotype Section and Point (GSSP) for the Hauterivian-Barremian transition. Spectral analyses of MS variations, coupled with the frequency ratio method, allow the recognition of precession, obliquity and eccentricity frequency bands. Orbitally-tuned magnetic susceptibility provides minimum durations for ammonite biozones. The durations of well-constrained ammonite zones are assessed at 0.78 myr for Pseudothurmannia ohmi (Late Hauterivian) and 0.57 myr for Taveraidiscus hugii (Early Barremian). These results are consistent with previous estimates from the other reference section (Angles, southeast France) and tend to show that the Río Argos section displays a complete succession for this time interval. They differ significantly from those proposed in the Geologic Time Scale 2008 and may help to improve the next compilation. The Faraoni Oceanic Anoxic Event, a key Early Cretaceous oceanographic perturbation occurring at the P. ohmi/P. catulloi subzone boundary has a duration estimated at 0.10-0.15 myr, which is similar to previous assessments.
Resumo:
Competing approaches exist, which allow control of phase noise and frequency tuning in mode-locked lasers, but no judgement of pros and cons based on a comparative analysis was presented yet. Here, we compare results of hybrid mode-locking, hybrid mode-locking with optical injection seeding, and sideband optical injection seeding performed on the same quantum dot laser under identical bias conditions. We achieved the lowest integrated jitter of 121 fs and a record large radio-frequency (RF) tuning range of 342 MHz with sideband injection seeding of the passively mode-locked laser. The combination of hybrid mode-locking together with optical injection-locking resulted in 240 fs integrated jitter and a RF tuning range of 167 MHz. Using conventional hybrid mode-locking, the integrated jitter and the RF tuning range were 620 fs and 10 MHz, respectively. © 2014 AIP Publishing LLC.
Resumo:
The purpose of this study was to test the hypotheses that in obese children: 1) hypocaloric diet (D) improves both heart rate recovery at 1 min (Delta HRR1) cfter an exercise test, and cardiac autonomic nervous system activity (CANSA) in obese children; 2) Diet and exercise training (DET) combined leads to greater improvement in both Delta HRR1 after an exercise test and in CANSA, than D alone. Moreover, we examined the relationships among Delta HRR1, CANSA, cardiorespiratory fitness and anthropometric variables (AV) in obese children submitted to D and to DET. 33 obese children (10 +/- 0.2 years; body mass index (BMI) >95(th) percentile) were divided into 2 groups: D (n = 15; BMI = 31 +/- 1 kg/m(2)) and DET (n = 18; 29 +/- 1 kg/m(2)). All children performed a maximal cardiopulmonary exercise test on a treadmill. The Delta HRR1 was defined as the difference between heart rate at peak and at 1-min post-exercise. CANSA was assessed using power spectral analysis of heart rate variability at rest. The sympathovagal balance (low frequency and high frequency ratio, LF/HF) was measured. After interventions, all obese children showed reduced body weight (P < 0.05). The D group did not improve in terms of peak VO(2), Delta HRR1 or LF/HF ratio (P > 0.05). In contrast, the DET group showed increased peak VO(2) (P = 0.01) and improved Delta HRR1 (Delta HRR1 = 37.3 +/- 2.6; P = 0.01) and LF/HF ratio (P = 0.001). The DET group demonstrated significant relationships among Delta HRR1, peak VO(2) and CANSA (P < 0.05). In conclusion, DET, in contrast to D, promoted improved Delta HRR1 and CANSA in obese children, suggesting a positive influence of increased levels of cardiorespiratory fitness by exercise training on cardiac autonomic activity.
Resumo:
This paper presents a compact embedded fuzzy system for three-phase induction-motor scalar speed control. The control strategy consists in keeping constant the voltage-frequency ratio of the induction-motor supply source. A fuzzy-control system is built on a digital signal processor, which uses speed error and speed-error variation to change both the fundamental voltage amplitude and frequency of a sinusoidal pulsewidth modulation inverter. An alternative optimized method for embedded fuzzy-system design is also proposed. The controller performance, in relation to reference and load-torque variations, is evaluated by experimental results. A comparative analysis with conventional proportional-integral controller is also achieved.
Resumo:
Predictions of water table fluctuations in coastal aquifers are needed for numerous coastal and water resources engineering problems. Most previous investigations have been based on the Boussinesq equation for the case of a vertical beach. In this note an analytical solution based on shallow water expansion for the spring- neap tide- induced water table fluctuations in a coastal aquifer is presented. Unlike most previous investigations, multitidal signals are considered with a sloping coastal aquifer. The new solution is verified by comparing with field observations from Ardeer, Scotland. On the basis of the analytical approximation the influences of higher- order components on water table elevation are examined first. Then, a parametric study has been performed to investigate the effects of the amplitude ratio (lambda), frequency ratio (omega), and phases (delta(1) and delta(2)) on the tide- induced water table fluctuations in a sloping sandy beach.
Resumo:
Background: The relation between left ventricular filing velocities determined by Doppler echocardiography and autonomic nervous system function assessed by heart rate variability (HRV) is unclear. The aim of this study was to evaluate the influence of the autonomic nervous system assessed by the time and frequency domain indices of HRV in the Doppler indices of left ventricular diastolic filling velocities in patients without heart disease. Methods: We studied 451 healthy individuals (255 female [56.4%]) with normal blood pressure, electrocardiogram, chest x-ray, and treadmill electrocardiographic exercise stress test results, with a mean age of 43 +/- 12 (range 15-82) years, who underwent transthoracic Doppler echocardiography and 24-hour electrocardiographic ambulatory monitoring. We studied indices of HRV on time (standard deviation [SD] of all normal sinus RR intervals during 24 hours, SD of averaged normal sinus RR intervals for all 5-minute segments, mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms) and frequency (low frequency, high frequency, very low frequency, low frequency/high frequency ratio) domains relative to peak flow velocity during rapid passive filling phase (E), atrial contraction (A), E/A ratio, E-wave deceleration time, and isovolumic relaxation time. Statistical analysis was performed with Pearson correlation and logistic regression. Results: Peak flow velocity during rapid passive filling phase (E) and atrial contraction (A), E/A ratio, and deceleration time of early mitral inflow did not demonstrate a significant correlation with indices of HRV in time and frequency domain. We found that the E/A ratio was < 1 in 45 individuals (10%). Individuals with an E/A ratio < 1 had lower indices of HRV in frequency domain (except low frequency/high frequency) and lower indices of the mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms in time domain. Logistic regression demonstrated that an E/A ratio < 1 was associated with lower HF. Conclusion: Individuals with no evidence of heart disease and an E/A ratio < 1 demonstrated a significant decrease in indexes of HRV associated with parasympathetic modulation. (J Am Soc Echocardiogr 2010;23: 762-5.)
Resumo:
Reliable detection of intrapartum fetal acidosis is crucial for preventing morbidity. Hypoxia-related changes of fetal heart rate variability (FHRV) are controlled by the autonomic nervous system. Subtle changes in FHRV that cannot be identified by inspection can be detected and quantified by power spectral analysis. Sympathetic activity relates to low-frequency FHRV and parasympathetic activity to both low- and high-frequency FHRV. The aim was to study whether intra partum fetal acidosis can be detected by analyzing spectral powers of FHRV, and whether spectral powers associate with hypoxia-induced changes in the fetal electrocardiogram and with the pH of fetal blood samples taken intrapartum. The FHRV of 817 R-R interval recordings, collected as a part of European multicenter studies, were analyzed. Acidosis was defined as cord pH ≤ 7.05 or scalp pH ≤ 7.20, and metabolic acidosis as cord pH ≤ 7.05 and base deficit ≥ 12 mmol/l. Intrapartum hypoxia increased the spectral powers of FHRV. As fetal acidosis deepened, FHRV decreased: fetuses with significant birth acidosis had, after an initial increase, a drop in spectral powers near delivery, suggesting a breakdown of fetal compensation. Furthermore, a change in excess of 30% of the low-to-high frequency ratio of FHRV was associated with fetal metabolic acidosis. The results suggest that a decrease in the spectral powers of FHRV signals concern for fetal wellbeing. A single measure alone cannot be used to reveal fetal hypoxia since the spectral powers vary widely intra-individually. With technical developments, continuous assessment of intra-individual changes in spectral powers of FHRV might aid in the detection of fetal compromise due to hypoxia.
Resumo:
L’objectif de la présente thèse était de caractériser le sommeil d’un groupe clinique d’enfants et d’adolescents ayant un trouble d’anxiété comme diagnostic primaire et le comparer à un groupe témoin. Dans un premier temps, nous avons vérifié si le profil de la fréquence cardiaque nocturne des enfants et des adolescents pouvait être regroupé selon le diagnostic. Pour ce faire, la fréquence cardiaque nocturne de 67 adolescents anxieux et 19 sujets non anxieux a été enregistrée à l’aide d’un équipement ambulatoire. Les résultats de cette étude montrent que le profil de la fréquence cardiaque nocturne chez les enfants anxieux varie selon le diagnostic. Alors que les adolescents non anxieux montrent un profil de la fréquence cardiaque nocturne plat, on retrouve les associations suivantes chez les adolescents ayant un trouble anxieux : a) un profil croissant de la fréquence cardiaque chez les adolescents ayant un trouble d’anxiété de séparation; b) un profil décroissant de la fréquence cardiaque chez les adolescents ayant un trouble d’anxiété généralisé; c) un profil en forme de U chez les adolescents ayant un trouble d’anxiété sociale. De plus, une association significative a été observée entre le diagnostic et la présence de fatigue matinale. L’association d’un profil de la fréquence cardiaque nocturne avec un diagnostic d’anxiété suggère la présence d’une dysrégulation de la modulation chronobiologique du système nerveux autonome. Étant donné que le profil de la fréquence cardiaque nocturne s’exprime différemment selon le diagnostic, qu’en est-il de l’architecture du sommeil? Dans un deuxième temps, nous avons enregistré le sommeil en laboratoire d’un groupe clinique de 19 jeunes ayant un trouble d’anxiété comme diagnostic primaire, avec comorbidités et médication et comparé à 19 jeunes non anxieux. Les résultats de cette étude ont montré que les participants du groupe anxieux ont une latence au sommeil plus longue, une latence au sommeil paradoxal plus longue et une durée d’éveil plus longue lorsque comparé au groupe témoin. L’évaluation subjective de la qualité du sommeil chez le groupe d’adolescents anxieux montre que leur auto-évaluation reflète les valeurs enregistrées en laboratoire. Nous avons également observé chez le groupe anxieux une fréquence cardiaque moyenne plus élevée et un index plus élevé d’apnée-hypopnée, bien que non pathologique. Nous avons également observé une association positive entre l’anxiété de trait et l’indice d’apnée-hypopnée et la latence au sommeil, ainsi qu’une association positive entre l’anxiété manifeste et la latence au sommeil paradoxal. Ces résultats suggèrent que le sommeil chez cette population est altéré, que des signes d’hypervigilance physiologique sont présents et qu'une association existe entre ces deux paramètres. Finalement, dans la troisième étude de cette thèse, nous avons analysé l’activité cardiaque pendant le sommeil en utilisant les paramètres temporels et fréquentiels de la variabilité cardiaque chez un groupe clinique de dix-sept enfants et adolescents ayant un trouble d’anxiété comme diagnostic primaire avec comorbidité et médication, et comparé à un groupe non anxieux. Les résultats ont montré que les participants du groupe anxieux, lorsque comparés au groupe non anxieux, présentent des intervalles interbattements plus courts, un indice temporel de la variabilité cardiaque représentant la branche parasympathique moindre, une activité des hautes fréquences normalisées moindre et un ratio basse fréquence sur haute fréquence augmenté. Plusieurs corrélations ont été observées entre les mesures cliniques de l’anxiété et les mesures de la variabilité cardiaque. Ces résultats viennent ajouter à la littérature actuelle un volet descriptif clinique à ce jour non documenté, soit l’impact de l’anxiété pathologique chez un groupe clinique d’enfants et d’adolescents sur le processus normal du sommeil et sur la régulation de la fréquence cardiaque. En résumé, les résultats de ces trois études ont permis de documenter chez un groupe clinique d’enfants et d’adolescents ayant de l’anxiété pathologique, la présence d’une altération circadienne du profil de la fréquence cardiaque, d’une architecture altérée du sommeil ainsi qu’une dysrégulation du système nerveux contrôlant l’activité cardiaque.
Resumo:
Le trouble comportemental en sommeil paradoxal (TCSP) est une parasomnie se caractérisant par la perte de l’atonie musculaire, la paralysie qui accompagne généralement le sommeil paradoxal, suivie de l’apparition de comportements indésirables et souvent violents. Des études suggèrent que le TCSP idiopathique (TCSPi) est fortement lié au développement ultérieur de la maladie de Parkinson, de la démence à corps de Lewy et de l’atrophie multisystémique. En effet, des signes subtils de neurodégénérescence sont observés chez ces patients, notamment un ralentissement de l’activité électrique cérébrale (EEG) à l’éveil et la présence de troubles cognitifs. Le but de cette thèse est 1) d’évaluer sur le plan transversal la contribution du trouble cognitif léger (TCL) dans le ralentissement de l’EEG à l’éveil observé chez ces patients et 2) d’évaluer la valeur prédictive des mesures de l’EEG à l’éveil mesurées au temps de base par rapport au développement d’une maladie neurodégénérative (MND) lors du suivi longitudinal. Dans le cadre de la première étude, l’EEG à l’éveil d’un groupe de patients avec un TCSPi présentant des atteintes cognitives a été comparé à celui d’un groupe de patients sans troubles cognitifs et à des sujets témoins sains. Seuls les patients avec un TCL affichaient un ralentissement de l’EEG d’éveil plus prononcé au niveau postérieur, c’est-à-dire une puissance relative thêta plus élevée dans les régions pariétale, temporale et occipitale, une puissance relative alpha plus faible dans les régions occipitale et temporale, en plus d’un ratio spectral (ondes lentes sur ondes rapides) plus élevé dans ces régions en comparaison avec les deux autres groupes. De plus, le ratio spectral corrélait négativement avec les fonctions attentionnelles/exécutives, visuospatiales et la mémoire épisodique verbale. La deuxième étude a quant à elle évalué l’EEG à l’éveil au temps initial de patients qui ont développé une MND sur une période de 3,5 ans en comparaison à celui de patients qui sont demeurés idiopathiques et à un groupe de témoins sains. Les patients avec un TCSPi qui ont évolué vers une MND présentaient une augmentation de la puissance de l’activité absolue delta et thêta, en plus d’un ratio spectral plus élevé dans les cinq régions corticales en comparaison avec les deux autres groupes. Cette thèse suggère ainsi que le ralentissement de l’EEG à l’éveil dans le TCSPi est relié à la présence d’un TCL concomitant. De plus, ces anomalies sont associées à un plus grand risque de développer une maladie de Parkinson, une démence à corps de Lewy ou une atrophie multisystémique à court terme chez ces patients. Le ralentissement de l’EEG à l’éveil semble donc être un marqueur prometteur d’une neurodégénérescence cérébrale plus sévère chez les patients souffrant d’un TCSPi.
Resumo:
Experimental studies on a compact dual frequency microstrip antenna are presented. This antenna configuration provides an area reduction of 40% compared to a standard rectangular antenna operating at the same frequency without much degradation of the gain. The antenna structure can be modified to achieve the desired ratio between the two resonant frequencies
Resumo:
Design of a compact dual frequency microstrip antenna is presented. The structure consists of a slotted circular patch with a dielectric superstrate. The superstrate,not only acts as a radome, but improves the bandwidth and lowers the resonant frequency also. The proposed design provides an overall size reduction of about 60% compared to an unslotted patch along with good efficiency,gain and bandwidth. The polarization planes at the two resonances are orthogonal and can be simultaneously excited using a coaxial feed. Parametric study of this configuration showed that the frequency ratio of the two resonances can be varied from 1.17 to 1.7 enabling its applications in the major wireless communication bands like AWS, DECT,PHS,Wi.Bro, ISM,and DMB. Design equations are also deduced for the proposed antenna and validated.