885 resultados para Frequency deviations


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Frequency deviation is a common problem for power system signal processing. Many power system measurements are carried out in a fixed sampling rate assuming the system operates in its nominal frequency (50 or 60 Hz). However, the actual frequency may deviate from the normal value from time to time due to various reasons such as disturbances and subsequent system transients. Measurement of signals based on a fixed sampling rate may introduce errors under such situations. In order to achieve high precision signal measurement appropriate algorithms need to be employed to reduce the impact from frequency deviation in the power system data acquisition process. This paper proposes an advanced algorithm to enhance Fourier transform for power system signal processing. The algorithm is able to effectively correct frequency deviation under fixed sampling rate. Accurate measurement of power system signals is essential for the secure and reliable operation of power systems. The algorithm is readily applicable to such occasions where signal processing is affected by frequency deviation. Both mathematical proof and numerical simulation are given in this paper to illustrate robustness and effectiveness of the proposed algorithm. Crown Copyright (C) 2003 Published by Elsevier Science B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper proposes a novel and simple positive sequence detector (PSD), which is inherently self-adjustable to fundamental frequency deviations by means of a software-based PLL (Phase Locked Loop). Since the proposed positive sequence detector is not based on Fortescue's classical decomposition and no special input filtering is needed, its dynamic response may be as fast as one fundamental cycle. The digital PLL ensures that the positive sequence components can be calculated even under distorted waveform conditions and fundamental frequency deviations. For the purpose of validating the proposed models, the positive sequence detector has been implemented in a PC-based Power Quality Monitor and experimental results illustrate its good performance. The PSD algorithm has also been evaluated in the control loop of a Series Active Filter and simulation results demonstrate its effectiveness in a closed-loop system. Moreover, considering single-phase applications, this paper also proposes a general single-phase PLL and a Fundamental Wave Detector (FWD) immune to frequency variations and waveform distortions. © 2005 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Faz-se nesta dissertação a análise do movimento humano utilizando sinais de ultrassons refletidos pelos diversos membros do corpo humano, designados por assinaturas de ultrassons. Estas assinaturas são confrontadas com os sinais gerados pelo contato dos membros inferiores do ser humano com o chão, recolhidos de forma passiva. O método seguido teve por base o estudo das assinaturas de Doppler e micro-Doppler. Estas assinaturas são obtidas através do processamento dos ecos de ultrassons recolhidos, com recurso à Short-Time Fourier Transform e apresentadas sobre a forma de espectrograma, onde se podem identificar os desvios de frequência causados pelo movimento das diferentes partes do corpo humano. É proposto um algoritmo inovador que, embora possua algumas limitações, é capaz de isolar e extrair de forma automática algumas das curvas e parâmetros característicos dos membros envolvidos no movimento humano. O algoritmo desenvolvido consegue analisar as assinaturas de micro-Doppler do movimento humano, estimando diversos parâmetros tais como o número de passadas realizadas, a cadência da passada, o comprimento da passada, a velocidade a que o ser humano se desloca e a distância percorrida. Por forma a desenvolver, no futuro, um classificador capaz de distinguir entre humanos e outros animais, são também recolhidas e analisadas assinaturas de ultrassons refletidas por dois animais quadrúpedes, um canino e um equídeo. São ainda estudadas as principais características que permitem classificar o tipo de animal que originou a assinatura de ultrassons. Com este estudo mostra-se ser possível a análise de movimento humano por ultrassons, havendo características nas assinaturas recolhidas que permitem a classificação do movimento como humano ou não humano. Do trabalho desenvolvido resultou ainda uma base de dados de assinaturas de ultrassons de humanos e animais que permitirá suportar trabalho de investigação e desenvolvimento futuro.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper discusses the main characteristics and presents a comparative analysis of three synchronization algorithms based respectively, on a Phase-Locked Loop, a Kalman Filter and a Discrete Fourier Transform. It will be described the single and three-phase models of the first two methods and the single-phase model of the third one. Details on how to modify the filtering properties or dynamic response of each algorithm will be discussed in terms of their design parameters. In order to compare the different algorithms, these parameters will be set for maximum filter capability. Then, the dynamic response, during input amplitude and frequency deviations will be observed, as well as during the initialization procedure. So, advantages and disadvantages of all considered algorithms will be discussed. ©2007 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents the development and modification of techniques to reduce the effects of load variation and mains frequency deviation in repetitive controllers applied to active power filters. To minimize the effects of aperiodic signals resulting from the connection or disconnection of non-linear loads is developed a technique which recognizes linear and nonlinear loads, and operates to reset the controller only when the error due to the transition of considerable value, and the transition is from non-linear to linear load. An algorithm to adapt the gain of the repetitive controller, based on a sigmoid function adaptation, in order to minimize the effects caused by random noise in the measurement system is also used. This work also analyzes the effects of frequency variation and presents the main methods to cope with this situation. Some solutions are the change in the number of samples per period and the variation of the sampling rate. The first has the advantage of using linear design techniques and results in a time invariant system. The second method changes the sampling frequency and leads to a time variant system that demands a difficult analysis of stability. The proposed algorithms were tested using the methods of truncation of the number of samples and the method of changing the sampling rate of the system to compensate possible frequency variations of the grid. Experimental results are presented to validate the proposal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study focuses on the analysis of winter (October-November-December-January-February-March; ONDJFM) storm events and their changes due to increased anthropogenic greenhouse gas concentrations over Europe. In order to assess uncertainties that are due to model formulation, 4 regional climate models (RCMs) with 5 high resolution experiments, and 4 global general circulation models (GCMs) are considered. Firstly, cyclone systems as synoptic scale processes in winter are investigated, as they are a principal cause of the occurrence of extreme, damage-causing wind speeds. This is achieved by use of an objective cyclone identification and tracking algorithm applied to GCMs. Secondly, changes in extreme near-surface wind speeds are analysed. Based on percentile thresholds, the studied extreme wind speed indices allow a consistent analysis over Europe that takes systematic deviations of the models into account. Relative changes in both intensity and frequency of extreme winds and their related uncertainties are assessed and related to changing patterns of extreme cyclones. A common feature of all investigated GCMs is a reduced track density over central Europe under climate change conditions, if all systems are considered. If only extreme (i.e. the strongest 5%) cyclones are taken into account, an increasing cyclone activity for western parts of central Europe is apparent; however, the climate change signal reveals a reduced spatial coherency when compared to all systems, which exposes partially contrary results. With respect to extreme wind speeds, significant positive changes in intensity and frequency are obtained over at least 3 and 20% of the European domain under study (35–72°N and 15°W–43°E), respectively. Location and extension of the affected areas (up to 60 and 50% of the domain for intensity and frequency, respectively), as well as levels of changes (up to +15 and +200% for intensity and frequency, respectively) are shown to be highly dependent on the driving GCM, whereas differences between RCMs when driven by the same GCM are relatively small.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report results of a study of the B-s(0) oscillation frequency using a large sample of B-s(0) semileptonic decays corresponding to approximately 1 fb(-1) of integrated luminosity collected by the D0 experiment at the Fermilab Tevatron Collider in 2002-2006. The amplitude method gives a lower limit on the B-s(0) oscillation frequency at 14.8 ps(-1) at the 95% C.L. At Delta m(s)=19 ps(-1), the amplitude deviates from the hypothesis A=0 (1) by 2.5 (1.6) standard deviations, corresponding to a two-sided C.L. of 1% (10%). A likelihood scan over the oscillation frequency, Delta m(s), gives a most probable value of 19 ps(-1) and a range of 17

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A previous work showed that viscosity values measured high frequency by ultrasound agreed with the values at low frequency by the rotational viscometer when conditions are met, such as relatively low frequency viscosity. However, these conditions strongly reduce the range of the measurement cell. In order to obtain a measurement range and sensitivity high frequency must used, but it causes a frequency-dependent decrease on the viscosity values. This work introduces a new simple in order to represent this frequency-dependent behavior.model is based on the Maxwell model for viscoelastic , but using a variable parameter. This parameter has physical meaning because it represents the linear behavior the apparent elasticity measured along with the viscosity by .Automotive oils SAE 90 and SAE 250 at 22.5±0.5oC viscosities at low frequency of 0.6 and 6.7 Pa.s, respectively,tested in the range of 1-5 MHz. The model was used in to fit the obtained data using an algorithm of non-linear in Matlab. By including the viscosity at low frequency an unknown fitting parameter, it is possible to extrapolate its . Relative deviations between the values measured by the and extrapolated using the model for the SAE 90 and SAE 250 oils were 5.0% and 15.7%, respectively.©2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The characteristics of aphasics’ speech in various languages have been the core of numerous studies, but Arabic in general, and Palestinian Arabic in particular, is still a virgin field in this respect. However, it is of vital importance to have a clear picture of the specific aspects of Palestinian Arabic that might be affected in the speech of aphasics in order to establish screening, diagnosis and therapy programs based on a clinical linguistic database. Hence the central questions of this study are what are the main neurolinguistic features of the Palestinian aphasics’ speech at the phonetic-acoustic level and to what extent are the results similar or not to those obtained from other languages. In general, this study is a survey of the most prominent features of Palestinian Broca’s aphasics’ speech. The main acoustic parameters of vowels and consonants are analysed such as vowel duration, formant frequency, Voice Onset Time (VOT), intensity and frication duration. The deviant patterns among the Broca’s aphasics are displayed and compared with those of normal speakers. The nature of deficit, whether phonetic or phonological, is also discussed. Moreover, the coarticulatory characteristics and some prosodic patterns of Broca’s aphasics are addressed. Samples were collected from six Broca’s aphasics from the same local region. The acoustic analysis conducted on a range of consonant and vowel parameters displayed differences between the speech patterns of Broca’s aphasics and normal speakers. For example, impairments in voicing contrast between the voiced and voiceless stops were found in Broca’s aphasics. This feature does not exist for the fricatives produced by the Palestinian Broca’s aphasics and hence deviates from data obtained for aphasics’ speech from other languages. The Palestinian Broca’s aphasics displayed particular problems with the emphatic sounds. They exhibited deviant coarticulation patterns, another feature that is inconsistent with data obtained from studies from other languages. However, several other findings are in accordance with those reported from various other languages such as impairments in the VOT. The results are in accordance with the suggestions that speech production deficits in Broca’s aphasics are not related to phoneme selection but rather to articulatory implementation and some speech output impairments are related to timing and planning deficits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The frequency distribution of aggregate size of the diffuse and florid-type prion protein (PrP) plaques was studied in various brain regions in cases of variant Creutzfeldt-Jakob disease (vCJD). The size distributions were unimodal and positively skewed and resembled those of β-amyloid (Aβ) deposits in Alzheimer's disease (AD) and Down's syndrome (DS). The frequency distributions of the PrP aggregates were log-normal in shape, but there were deviations from the expected number of plaques in specific size classes. More diffuse plaques were observed in the modal size class and fewer in the larger size classes than expected and more florid plaques were present in the larger size classes compared with the log-normal model. It was concluded that the growth of the PrP aggregates in vCJD does not strictly follow a log-normal model, diffuse plaques growing to within a more restricted size range and florid plaques to larger sizes than predicted. © Springer-Verlag 2005.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation contains four essays that all share a common purpose: developing new methodologies to exploit the potential of high-frequency data for the measurement, modeling and forecasting of financial assets volatility and correlations. The first two chapters provide useful tools for univariate applications while the last two chapters develop multivariate methodologies. In chapter 1, we introduce a new class of univariate volatility models named FloGARCH models. FloGARCH models provide a parsimonious joint model for low frequency returns and realized measures, and are sufficiently flexible to capture long memory as well as asymmetries related to leverage effects. We analyze the performances of the models in a realistic numerical study and on the basis of a data set composed of 65 equities. Using more than 10 years of high-frequency transactions, we document significant statistical gains related to the FloGARCH models in terms of in-sample fit, out-of-sample fit and forecasting accuracy compared to classical and Realized GARCH models. In chapter 2, using 12 years of high-frequency transactions for 55 U.S. stocks, we argue that combining low-frequency exogenous economic indicators with high-frequency financial data improves the ability of conditionally heteroskedastic models to forecast the volatility of returns, their full multi-step ahead conditional distribution and the multi-period Value-at-Risk. Using a refined version of the Realized LGARCH model allowing for time-varying intercept and implemented with realized kernels, we document that nominal corporate profits and term spreads have strong long-run predictive ability and generate accurate risk measures forecasts over long-horizon. The results are based on several loss functions and tests, including the Model Confidence Set. Chapter 3 is a joint work with David Veredas. We study the class of disentangled realized estimators for the integrated covariance matrix of Brownian semimartingales with finite activity jumps. These estimators separate correlations and volatilities. We analyze different combinations of quantile- and median-based realized volatilities, and four estimators of realized correlations with three synchronization schemes. Their finite sample properties are studied under four data generating processes, in presence, or not, of microstructure noise, and under synchronous and asynchronous trading. The main finding is that the pre-averaged version of disentangled estimators based on Gaussian ranks (for the correlations) and median deviations (for the volatilities) provide a precise, computationally efficient, and easy alternative to measure integrated covariances on the basis of noisy and asynchronous prices. Along these lines, a minimum variance portfolio application shows the superiority of this disentangled realized estimator in terms of numerous performance metrics. Chapter 4 is co-authored with Niels S. Hansen, Asger Lunde and Kasper V. Olesen, all affiliated with CREATES at Aarhus University. We propose to use the Realized Beta GARCH model to exploit the potential of high-frequency data in commodity markets. The model produces high quality forecasts of pairwise correlations between commodities which can be used to construct a composite covariance matrix. We evaluate the quality of this matrix in a portfolio context and compare it to models used in the industry. We demonstrate significant economic gains in a realistic setting including short selling constraints and transaction costs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nitrous oxide (N2O) emissions from soil are often measured using the manual static chamber method. Manual gas sampling is labour intensive, so a minimal sampling frequency that maintains the accuracy of measurements would be desirable. However, the high temporal (diurnal, daily and seasonal) variabilities of N2O emissions can compromise the accuracy of measurements if not addressed adequately when formulating a sampling schedule. Assessments of sampling strategies to date have focussed on relatively low emission systems with high episodicity, where a small number of the highest emission peaks can be critically important in the measurement of whole season cumulative emissions. Using year-long, automated sub-daily N2O measurements from three fertilised sugarcane fields, we undertook an evaluation of the optimum gas sampling strategies in high emission systems with relatively long emission episodes. The results indicated that sampling in the morning between 09:00–12:00, when soil temperature was generally close to the daily average, best approximated the daily mean N2O emission within 4–7% of the ‘actual’ daily emissions measured by automated sampling. Weekly sampling with biweekly sampling for one week after >20 mm of rainfall was the recommended sampling regime. It resulted in no extreme (>20%) deviations from the ‘actuals’, had a high probability of estimating the annual cumulative emissions within 10% precision, with practicable sampling numbers in comparison to other sampling regimes. This provides robust and useful guidance for manual gas sampling in sugarcane cropping systems, although further adjustments by the operators in terms of expected measurement accuracy and resource availability are encouraged. By implementing these sampling strategies together, labour inputs and errors in measured cumulative N2O emissions can be minimised. Further research is needed to quantify the spatial variability of N2O emissions within sugarcane cropping and to develop techniques for effectively addressing both spatial and temporal variabilities simultaneously.