995 resultados para Free neutron decay
Resumo:
The beta-decay of free neutrons is a strongly over-determined process in the Standard Model (SM) of Particle Physics and is described by a multitude of observables. Some of those observables are sensitive to physics beyond the SM. For example, the correlation coefficients of the involved particles belong to them. The spectrometer aSPECT was designed to measure precisely the shape of the proton energy spectrum and to extract from it the electron anti-neutrino angular correlation coefficient "a". A first test period (2005/ 2006) showed the “proof-of-principles”. The limiting influence of uncontrollable background conditions in the spectrometer made it impossible to extract a reliable value for the coefficient "a" (publication: Baessler et al., 2008, Europhys. Journ. A, 38, p.17-26). A second measurement cycle (2007/ 2008) aimed to under-run the relative accuracy of previous experiments (Stratowa et al. (1978), Byrne et al. (2002)) da/a =5%. I performed the analysis of the data taken there which is the emphasis of this doctoral thesis. A central point are background studies. The systematic impact of background on a was reduced to da/a(syst.)=0.61 %. The statistical accuracy of the analyzed measurements is da/a(stat.)=1.4 %. Besides, saturation effects of the detector electronics were investigated which were initially observed. These turned out not to be correctable on a sufficient level. An applicable idea how to avoid the saturation effects will be discussed in the last chapter.
Resumo:
The first spectroscopic study for the beta decay of N-21 is carried out based on beta-n, beta-gamma, and beta-n-gamma coincidence measurements. The neutron-rich N-21 nuclei are produced by the fragmentation of the E/A=68.8 MeV Mg-26 primary beam on a thick Be-9 target and are implanted into a thin plastic scintillator that also plays the role of beta detector. The time of flight of the emitted neutrons following the beta decay are measured by the surrounding neutron sphere and neutron wall arrays. In addition, four clover germanium detectors are used to detect the beta-delayed gamma rays. Thirteen new beta-delayed neutron groups are observed with a total branching ratio of 90.5 +/- 4.2%. The half-life for the beta decay of N-21 is determined to be 82.9 +/- 7.5 ms. The level scheme of O-21 is deduced up to about 9 MeV excitation energy. The experimental results for the beta decay of N-21 are compared to the shell-model calculations.
Resumo:
The beta-delayed neutron and gamma spectra of neutron-rich nucleus N-21 using beta-gamma and beta-n coincidence measurements were presented in this paper. Thirteen new neutron groups ranging from 0.28 MeV to 4.98 MeV and with a total branching ratio 88.7 +/- 4.2% were observed. One gamma transition among the excited states of O-21 and foury transitions among the excited states of O-20 were identified in the beta decay chain of N-21. The ungated half-life of 83.8 +/- 2.1 ms was also determined for N-21.
Resumo:
Based on the isospin- and momentum-dependent transport model IBUU04, the transverse momentum distributions of the free neutron-proton ratio in the Sn-132+(124) Sn reaction system at mid-central collisions with beam energies of 400/A MeV, 600/A MeV and 800/A MeV are studied by using two different symmetry energies. It is found that the free neutron-proton ratio as a function of the transverse momentum at the mid-rapidity is very sensitive to the density dependency of the symmetry energy especially at incident energies around 400/AMeV.
Resumo:
Nanocrystalline SnO2 quantum dots were synthesized at room temperature by hydrolysis reaction of SnCl2. The addition of tetrabutyl ammonium hydroxide and the use of hydrothermal treatment enabled one to obtain tin dioxide colloidal suspensions with mean particle radii ranging from 1.5 to 4.3 nm. The photoluminescent properties of the suspensions were studied. The particle size distribution was estimated by transmission electron microscopy. Assuming that the maximum intensity photon energy of the photoluminescence spectra is related to the band gap energy of the system, the size dependence of the band gap energies of the quantum-confined SnO2 particles was studied. This dependence was observed to agree very well with the weak confinement regime predicted by the effective mass model. This might be an indication that photoluminescence occurs as a result of a free exciton decay process. (C) 2004 American Institute of Physics.
Resumo:
The aSPECT spectrometer has been constructed to measure, with high precision, the integral proton spectrum of the free neutron decay. From this spectrum the neutrino electron angular correlation coefficient a can be inferred. The coefficient a is involved in several Standard Model tests, like the unitarity test of the Cabibbo-Kobayashi-Maskawa quark mixing matrix. aSPECT has been designed to determine the coefficient a with an accuracy better than 3×10−4, that is, one order of magnitude better than the best current accuracy. First measurements with neutron beam with the aSPECT spectrometer were performed in the Forschungsneutronenquelle Heinz Maier-Leibnitz, in Munich. A study of the data taken in this period is presented in this thesis, demonstrating the proof of principle of the spectrometer. However, the observation of situation and time-dependent background instabilities impedes the report of a new value of the coefficient a. A thorough data analysis is carried out to identify sources of these background instabilities in order to improve the aSPECT experiment for future beam times. The investigation indicates that trapped particles are most likely the reason for the background problems. Furthermore, it has been observed that measurements containing less trapped particles provide a-values closer to the currently Particle Data Group value. Based on this findings, different measures are proposed to eliminate potential traps in the spectrometer. Indeed, with the proposed modifications realized for the following beam-times, the observed background instabilities were greatly reduced.
Resumo:
Das aSPECT Spektrometer wurde entworfen, um das Spektrum der Protonen beimrnZerfall freier Neutronen mit hoher Präzision zu messen. Aus diesem Spektrum kann dann der Elektron-Antineutrino Winkelkorrelationskoeffizient "a" mit hoher Genauigkeit bestimmt werden. Das Ziel dieses Experiments ist es, diesen Koeffizienten mit einem absoluten relativen Fehler von weniger als 0.3% zu ermitteln, d.h. deutlich unter dem aktuellen Literaturwert von 5%.rnrnErste Messungen mit dem aSPECT Spektrometer wurden an der Forschungsneutronenquelle Heinz Maier-Leibnitz in München durchgeführt. Jedoch verhinderten zeitabhängige Instabilitäten des Meßhintergrunds eine neue Bestimmung von "a".rnrnDie vorliegende Arbeit basiert hingegen auf den letzten Messungen mit dem aSPECTrnSpektrometer am Institut Laue-Langevin (ILL) in Grenoble, Frankreich. Bei diesen Messungen konnten die Instabilitäten des Meßhintergrunds bereits deutlich reduziert werden. Weiterhin wurden verschiedene Veränderungen vorgenommen, um systematische Fehler zu minimieren und um einen zuverlässigeren Betrieb des Experiments sicherzustellen. Leider konnte aber wegen zu hohen Sättigungseffekten der Empfängerelektronik kein brauchbares Ergebnis gemessen werden. Trotzdem konnten diese und weitere systematische Fehler identifiziert und verringert, bzw. sogar teilweise eliminiert werden, wovon zukünftigernStrahlzeiten an aSPECT profitieren werden.rnrnDer wesentliche Teil der vorliegenden Arbeit befasst sich mit der Analyse und Verbesserung der systematischen Fehler, die durch das elektromagnetische Feld aSPECTs hervorgerufen werden. Hieraus ergaben sich vielerlei Verbesserungen, insbesondere konnten die systematischen Fehler durch das elektrische Feld verringert werden. Die durch das Magnetfeld verursachten Fehler konnten sogar soweit minimiert werden, dass nun eine Verbesserung des aktuellen Literaturwerts von "a" möglich ist. Darüber hinaus wurde in dieser Arbeit ein für den Versuch maßgeschneidertes NMR-Magnetometer entwickelt und soweit verbessert, dass nun Unsicherheiten bei der Charakterisierung des Magnetfeldes soweit reduziert wurden, dass sie für die Bestimmung von "a" mit einer Genauigkeit von mindestens 0.3% vernachlässigbar sind.
Resumo:
The free neutron beta decay correlation A0 between neutron polarization and electron emission direction provides the strongest constraint on the ratio λ = gA/gV of the Axial-vector to Vector coupling constants in Weak decay. In conjunction with the CKM Matrix element Vud and the neutron lifetime τn, λ provides a test of Standard Model assumptions for the Weak interaction. Leading high-precision measurements of A0 and τn in the 1995-2005 time period showed discrepancies with prior measurements and Standard Model predictions for the relationship between λ, τn, and Vud. The UCNA experiment was developed to measure A0 from decay of polarized ultracold neutrons (UCN), providing a complementary determination of λ with different systematic uncertainties from prior cold neutron beam experiments. This dissertation describes analysis of the dataset collected by UCNA in 2010, with emphasis on detector response calibrations and systematics. The UCNA measurement is placed in the context of the most recent τn results and cold neutron A0 experiments.
Resumo:
Research in fundamental physics with the free neutron is one of the key tools for testing the Standard Model at low energies. Most prominent goals in this field are the search for a neutron electric dipole moment (EDM) and the measurement of the neutron lifetime. Significant improvements of the experimental performance using ultracold neutrons (UCN) require reduction of both systematic and statistical errors.rnThe development and construction of new UCN sources based on the superthermal concept is therefore an important step for the success of future fundamental physics with ultracold neutrons. rnSignificant enhancement of today available UCN densities strongly correlates with an efficient use of an UCN converter material. The UCN converter here is to be understood as a medium which reduces the velocity of cold neutrons (CN, velocity of about 600 m/s) to the velocity of UCN (velocity of about 6 m/s).rnSeveral big research centers around the world are presently planning or constructing new superthermal UCN sources, which are mainly based on the use of either solid deuterium or superfluid helium as UCN converter.rnThanks to the idea of Yu.Pokotilovsky, there exists the opportunity to build competitive UCN sources also at small research reactors of the TRIGA type. Of course these smaller facilities don't promise high UCN densities of several 1000 UCN/cm³, but they are able to provide densities around 100 UCN/cm³ for experiments.rnIn the context of this thesis, it was possible to demonstrate succesfully the feasibility of a superthermal UCN source at the tangential beamport C of the research reactor TRIGA Mainz. Based on a prototype for the future UCN source at the Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRMII) in munich, which was planned and built in collaboration with the Technical University of Munich, further investigations and improvements were done and are presented in this thesis. rnIn parallel, a second UCN source for the radial beamport D was designed and built. The comissioning of this new source is foreseen in spring 2010.rnAt beamport D with its higher thermal neutron flux, it should be possible to increase the available UCN densities of 4 UCN/cm³ by minimum one order of magnitude.
Resumo:
Die elektromagnetischen Nukleon-Formfaktoren sind fundamentale Größen, welche eng mit der elektromagnetischen Struktur der Nukleonen zusammenhängen. Der Verlauf der elektrischen und magnetischen Sachs-Formfaktoren G_E und G_M gegen Q^2, das negative Quadrat des Viererimpulsübertrags im elektromagnetischen Streuprozess, steht über die Fouriertransformation in direkter Beziehung zu der räumlichen Ladungs- und Strom-Verteilung in den Nukleonen. Präzise Messungen der Formfaktoren über einen weiten Q^2-Bereich werden daher für ein quantitatives Verständnis der Nukleonstruktur benötigt.rnrnDa es keine freien Neutrontargets gibt, gestaltet sich die Messung der Neutron-Formfaktoren schwierig im Vergleich zu der Messung am Proton. Konsequenz daraus ist, dass die Genauigkeit der vorhandenen Daten von Neutron-Formfaktoren deutlich geringer ist als die von Formfaktoren des Protons; auch der vermessene Q^2-Bereich ist kleiner. Insbesondere der elektrische Sachs-Formfaktor des Neutrons G_E^n ist schwierig zu messen, da er aufgrund der verschwindenden Nettoladung des Neutrons im Verhältnis zu den übrigen Nukleon-Formfaktoren sehr klein ist. G_E^n charakterisiert die Ladungsverteilung des elektrisch neutralen Neutrons und ist damit besonders sensitiv auf die innere Struktur des Neutrons.rnrnIn der hier vorgestellten Arbeit wurde G_E^n aus Strahlhelizitätsasymmetrien in der quasielastischen Streuung vec{3He}(vec{e}, e'n)pp bei einem Impulsübertrag von Q^2 = 1.58 (GeV/c)^2 bestimmt. Die Messung fand in Mainz an der Elektronbeschleunigeranlage Mainzer Mikrotron innerhalb der A1-Kollaboration im Sommer 2008 statt. rnrnLongitudinal polarisierte Elektronen mit einer Energie von 1.508 GeV wurden an einem polarisierten ^3He-Gastarget, das als effektives, polarisiertes Neutrontarget diente, gestreut. Die gestreuten Elektronen wurden in Koinzidenz mit den herausgeschlagenen Neutronen detektiert; die Elektronen wurden in einem magnetischen Spektrometer nachgewiesen, durch den Nachweis der Neutronen in einer Matrix aus Plastikszintillatoren wurde der Beitrag der quasielastischen Streuung am Proton unterdrückt.rnrnAsymmetrien des Wirkungsquerschnitts bezüglich der Elektronhelizität sind bei Orientierung der Targetpolarisation in der Streuebene und senkrecht zum Impulsübertrag sensitiv auf G_E^n / G_M^n; mittels deren Messung kann G_E^n bestimmt werden, da der magnetische Formfaktor G_M^n mit vergleichsweise hoher Präzision bekannt ist. Zusätzliche Messungen der Asymmetrie bei einer Polarisationsorientierung parallel zum Impulsübertrag wurden genutzt, um systematische Fehler zu reduzieren.rnrnFür die Messung inklusive statistischem (stat) und systematischem (sys) Fehler ergab sich G_E^n = 0.0244 +/- 0.0057_stat +/- 0.0016_sys.
Resumo:
Internal motions in a A2BX4 compound (tetramethylammonium tetrabromo cadmate) have been investigated using proton spin—lattice relaxation time (T1) and second moment (M2) measurements in the temperature range 77 to 400 K. T1 measurements at three Larmor frequencies (10, 20 and 30 MHz) show isotropic tumbling of the tetramethylammonium group, random reorientation of methyl groups and spin—rotation interaction, and the corresponding parameters have been computed. The cw spectrum is narrow throughout the temperature range and shows side bands at the lowest temperature. This observation, along with the free-induction-decay behavior at these temperatures, is interpreted as the onset of a coherent motion, e.g. methyl group quantum tunnelling.
Resumo:
Proton magnetic resonance and spin-lattice relaxation studies have been carried out on (NH4)2CdI4 as a function of temperature (77–400 K) and Larmor frequency (10, 20 and 30 MHz). The T1 data indicate isotropic tumbling of ammonium ions at equivalent sites till 160 K. There is an indication of a phase transition at 265 K, the activation energy for molecular reorientation increases from 2.8 kcal/mole to 4.6 kcal/mole. The relaxation results and the linewidth data support the presence of two inequivalent sites at low temperatures, one having an environment corresponding to near-rigid-lattice limit and the other undergoing fast reorientations. The behaviour of the free induction decay with temperature below 120 K suggests a coherent motion for the faster species.
Resumo:
second moment measurements are carried out on [(CH,),N], CdI, in the temperature range 77 to 400 K. The results are interpreted based on a molecular dynamical model of randomly reorienting methyl groups and isotropically tumbling tetramethyl ammonium group. The relaxation data show contributions from spin-rotation interaction at high temperatures and presence of inequivalent methyl groups. The correlation times and associated activation energies, connected with this model, are calculated from the data. The structure in the absorption line and in the free-induction decay signal at 77 K indicates the possibility of tunnelling motion of the methyl groups. Im Temperaturbereich 77 bis 400 K werden an [(CH,),N],CdI, Protonen-Spin-Gitter-Relaxationsexperimente (bei Larmorfrequenzen von 10,20 und 30 MHz) und Messungen des zweiten Moments durchgefiihrt. Die Ergebnisse werden an Hand eines molekularen dynamischen Modells sich statistisch umorientierender Methylgruppen und isotrop taumelnder Tetramethyl-Ammoniumgruppen interpretiert. Die Relaxationswerte zeigen Beitriige von Spin-Rotations-Wechselwirkung bei hohen Temperaturen und die Anwesenheit von inaquivalenten Methylgruppen. Die Korrelationszeiten und verknupften Aktivierungsenergien, die mit diesem Model1 verbunden sind, werden am den Werten berechnet. Die Struktur in der Absorptionslinie und im Abklingsignal der freien Induktion bei 77 K zeigt die Moglichkeit einer Tunnelbewegung der Methylgruppen.
Resumo:
Optical limiting and thermo-optic properties of C60 in toluene are studied using 532 nm, 9 ns pulses from a frequency-doubled Nd:YAG laser. Optical limiting studies in these fullerene molecules lead to the conclusion that reverse saturable absorption is the major mechanism for limiting properties in these molecules. Thermal lensing measurements are also performed in fullerene solutions. The quadratic dependence of thermal lens signal on incident energy confirms that enhanced optical absorption by the sample via excited triplet state absorption may play a leading role in the limiting property.
Resumo:
The Carr-Purcell pulse sequence, with low refocusing flip angle, produces echoes midway between refocusing pulses that decay to a minimum value dependent on T*(2). When the refocusing flip angle was pi/2 (CP90) and tau > T*(2), the signal after the minimum value, increased to reach a steady-state free precession regime (SSFP), composed of a free induction decay signal after each pulse and an echo, before the next pulse. When tau < T*(2), the signal increased from the minimum value to the steady-state regime with a time constant (T*) = 2T(1)T(2)/(T-1 + T-2). identical to the time constant observed in the SSFP sequence, known as the continuous wave free precession (CWFP). The steady-state amplitude obtained with M-cp90 = M0T2/(T-1+T-2) was identical to CWFP. Therefore, this sequence was named CP-CWFP because it is a Carr-Purcell sequence that produces results similar to the CWFP. However, CP-CWFP is a better sequence for measuring the longitudinal and transverse relaxation times in single scan, when the sample exhibits T-1 similar to T-2. Therefore, this sequence can be a useful method in time domain NMR and can be widely used in the agriculture, food and petrochemical industries because those samples tend to have similar relaxation times in low magnetic fields. (C) 2011 Elsevier Inc. All rights reserved.