849 resultados para Fouling membrane


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work investigates the fouling mechanisms of PVDF hollow fibre membrane (0.03 μm) during the dead end ultrafiltration at a fixed permeate flux (outside to inside configuration) of complex synthetic seawater composed by humic acids, alginic acids, inorganic particles and numerous salts at high concentrations. Short term ultrafiltration experiments at 100 L.h-1.m-2 show that the optimal specific filtered volume seems to be equal to 50 L.m-2. A residual fouling resistance equal to 2.1010 m-1 is added after each cycle of filtration during 8h of ultrafiltration at 100 L.h-1.m-2 and 50 L.m-2. Most of the fouling is reversible (80%). Organics are barely (15% of humic acids) retained by the membrane. Backwash efficiency drops during operation which induces less organics into backwash waters. Humic acids could preferentially accumulate on the membrane early in the ultrafiltration and alginic acids after the build-up of a fouling pre-layer. Colloids and particulates could accumulate inside a heterogeneous fouling layer and/or the concentrate compartment of the membrane module before being more largely recovered inside backwash waters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho na área dos processos físicos de separação por membranas, nomeadamente, a nanofiltração (NF), tem como objectivo principal a recuperação dos efluentes resultantes das águas da 3ª lavagem utilizadas na operação de tingimento de fibras de algodão, com corantes reactivos. Estão inerentes as problemáticas: da escassez da água como matéria-prima na vertente de água potável; da diminuição de efluentes que necessitam de tratamentos devido à sua carga poluente; da recuperação sempre que seja viável dos produtos químicos adicionados nesta fase de tratamento das fibras de algodão e por último e não menos importante, da energia contida nestes efluentes que vão para o esgoto a temperaturas na ordem dos 50 ºC. A metodologia adoptada na realização deste trabalho consistiu, inicialmente num estudo sobre os trabalhos realizados até hoje nesta área, seguindo-se a recolha dos efluentes na empresa ―Estamparia Têxtil Adalberto Pinto da Silva, S.A.‖ (ETAPS) e posterior estudo da recuperação dos efluentes em causa pelo processo de NF utilizando a membrana NF270-2540 da empresa FILMTEC. Os efluentes estudados no presente trabalho continham corantes reactivos sendo um corante azul-claro (CAC) de composição (Amarelo Bril Remazol GL 150% + Azul Brilhante Remazol BB 133% + Azul Turqueza Remazol G) e o outro corante azul-marinho (CAM) de composição (Preto Remazol B 133% + Vermelho Remazol RGB + Amarelo Ouro Remazol RGB). Estes estudos de recuperação compreenderam basicamente 3 fases: caracterização do efluente recolhido na empresa; tratamento desse efluente utilizando uma instalação piloto de NF de fluxo cruzado ou também conhecido por membrana de fluxo tangencial instalado no Laboratório de Tecnologia (LT) do Instituto Superior de Engenharia do Porto (ISEP), e caracterização dos permeados e dos rejeitados obtidos. A análise de resultados do presente trabalho permitiu concluir ser possível a recuperação e reutilização das 3ª águas de lavagem do processo de tingimento quando tratadas pelo processo de NF a pressões de operação de 6 bar. Nestas circunstâncias os permeados obtidos (tanto no efluente com corante azul-claro como no efluente com corante azul-marinho) apresentam valores, em todos os parâmetros estudados, significativamente abaixo dos valores limites recomendáveis para uma água de abastecimento na Industria Têxtil (IT). Salienta-se reduções mais expressivas nos permeados do corante CAM, com vários parâmetros a sofrerem reduções no intervalo de 98 a 100%, nomeadamente, na cor, turvação, CQO, dureza total, alumínio e manganês. Os resultados obtidos para as pressões de operação de 4 e 8 bar mostram alguns parâmetros com valores acima dos recomendados para uma água de abastecimento na Indústria Têxtil, nomeadamente a cor no corante CAC quando se opera a 4 bar e no corante CAM quando se opera a 8 bar e os sulfatos e ferro no CAM à pressão de 4 bar. Estes resultados mostram ser possível a reutilização da água na própria instalação industrial, trazendo um benefício económico e ambiental, pela redução no consumo de água fresca e energia, além da redução do volume de efluentes que necessitam ser tratados, estando na mesma linha de pensamento de Gross et al (1999), que refere que o uso de membranas para o tratamento de efluentes do processo de tingimento tem como principal objectivo a viabilidade económica, a redução no consumo de água, de sais, de corantes e energia, bem como, a redução do volume de efluentes a ser tratado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Main objective of this research was to find suitable polymeric ultrafiltration membranes with high retentions, good capacities and low fouling tendencies for the E2- and EP-effluent ultrafiltration. Purpose was to treat alkaline bleaching effluents with ultrafiltration in a way that permeates of the filtrations could be recycled back to process and the consumption of fresh water in the pulp mill could be reduced significantly. In the theoretical part of this work the challenges set by the pulp and paper indus-try processes for membranes were examined. An overview of the membrane tech-nology in the pulp industry was also provided. In addition process conditions in the chemical pulp bleaching and properties of bleaching effluents were discussed in literature study. In experimental part the E2- and EP-stage bleaching effluents from Stora Enso Imatra kraft pulp mill were ultrafiltered with CR250- and CR200-filters. Suitable membranes for ultrafiltration were chosen after screening experiments. Concentra-tion experiment was made for the E2-effluent in order to estimate water saving potential. The E2-effluent was finally ultrafiltered in the pulp mill in order to test the feasibility of ultrafiltration in a real industrial environment. Good membrane for the EP-effluent ultrafiltration based on the EP-screening ex-periments was polyethersulfone membrane UP020 with cut-off value of 20 000 Da. Polysulfone membrane UFX05 with cut-off value of 5 000 Da was promising membrane for the ultrafiltration of the E2-effluent. Based on the concentration filtration of the E2-effluent with UFX05 membrane the water saving potential could be 2.2 m3/Adt for the industrial scale ultrafiltration process. Retention re-sults, such as average COD retention of 60 %, from the trial filtration at the pulp mill with UFX05 membrane were modest compared to the screening experiments, where average COD retention was 75 %. Therefore tighter ultrafiltration mem-branes should be tested for the ultrafiltration of the E2-effluent. The UP020 mem-brane seemed to be suitable for the ultrafiltration of the EP-effluent however con-centration and pilot scale ultrafiltration experiments are needed to verify this.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tässä diplomityössä tutkittiin biomassahydrolysaatilla liattujen ultrasuodatusmembraanien pesua. Työn kirjallisuusosassa käsitellään membraanien likaantumista ja pesua, puuperäistä biomassahydrolysaattia sekä biomassahydrolysaatin suodatusta membraaneilla ja membraanien karakterisointia. Kokeellisessa osassa tutkittiin pesuaineiden vaikutusta koivuhydrolysaatilla liattujen membraanien peseytyvyyteen. Käytetyt ultrasuodatusmembraanit olivat Alfa Lavalin UFX5 ja ETNA01PP. Membraanien pesussa käytettiin Ecolabin entsymaattisia P3-ultrasil 53 ja P3-ultrasil 67 pesuaineita yhdessä emäksisen P3-ultrasil 69 pesuaineen kanssa sekä hapanta P3-ultrasil 75 pesuainetta. Lisäksi emäksisiä P3-ultrasil 110, P3-ultrasil 112 ja P3-ultrasil 115 pesuaineita. Emäksisten pesujen tehokkuutta vertailtiin pelkällä natriumhydroksidilla tehtyyn pesuun. Membraanien likaantumista arvioitiin mittaamalla puhtaan veden vuota ennen ja jälkeen likaantumissuodatuksen ja laskemalla niiden vuoarvojen erotus. Samalla tavalla arvioitiin pesuaineiden vaikutusta membraanin peseytyvyyteen. Lisäksi peseytyvyyttä arvioitiin FTIR–analyyseillä, kontaktikulmamittauksilla ja membraanin sisältämän ligniinin värjäyksellä. Tutkimuksissa havaittiin, että koivuhydrolysaatilla liatuille UFX5 membraaneille vesivuon sekä FTIR–spektrin muuttumisen perusteella sopii parhaiten emäksisen ja happaman pesuaineen kaksivaiheinen pesu. Kontaktikulman palautumisen perusteella parhaiten sopi pelkällä emäksisellä P3-Ultrasil 115 tehty pesu. Ligniiniä parhaiten, mikroskooppiin liitetyllä kameralla otettujen kuvien perusteella, poisti entsymaattinen P3-ultrasil 67, mutta tämä samalla modifioi membraanin pintaa. Tässä tutkimuksessa havaittiin, että emäksinen ja entsymaattinen pesuaine pesevät melko hyvin koivuhydrolysaatilla liattuja membraaneja. Lisäksi havaittiin, että ligniini tunkeutuu suodatuksissa membraanin sisään, joten pelkkä pesuaineen kierrättäminen laitteistossa ei riitä vaan tarvitaan paineellista pesua.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente,perfil Sanitária

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The EM3E Master is an Education Programme supported by the European Commission, the European Membrane Society (EMS), the European Membrane House (EMH), and a large international network of industrial companies, research centres and universities

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis fouling of conventional filter fabrics and membranes was studied. In the beginning of the thesis fouling and how it can be measured and predicted is reviewed. Information on different methods on how fouling canbe decreased or cleaned away is also given. The experimental part is divided into two sections; fabric filtration and membrane filtration. Fouling of the filter fabrics was studied with silica or cupper slurries and fouling of the membranes was studied with pulp and paper mill waters. The fouled filter materials were characterised according to many different methods. The most useful way to observe fouling is to measure the changes in the permeate flux. Fouling can also be seen visually e.g. with scanning electron microscopy. Consequently, also the reason for the fouling in question might be found. Different filtration characteristics affect fouling e.g. as the filtration pressure was increased it did not have much influence on the permeate flux, but the pressure caused the membrane to get fouled faster. Also, an increase of shear rate on the membrane surface decreased fouling. Different pretreatment methods for the effluent were tested in membrane filtration to decrease fouling. The tested methods; biological treatment, ozonation, enzymatic treatment and flocculation, did not have a clear influence on the fouling of the membrane, but e.g. a biological treatment combined with ultrafiltration made the tested groundwood mill circulation water purer than ultrafiltration alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis the membrane filtration equipment for plate type ceramic membranes was developed based on filtration results achieved with different kinds of wastewaters. The experiments were mainly made with pulp and board mill wastewaters, but some experiments were also made with a bore well water and a stone cutting mine wastewater. The ceramicmembranes used were alpha-alumina membranes with a pore size of 100 nm. Some ofthe membranes were coated with a gamma-alumina layer to reduce the membrane pore size to 10 nm, and some of them were modified with different metal oxides in order to change the surface properties of the membranes. The effects of operationparameters, such as cross-flow velocity, filtration pressure and backflushing on filtration performance were studied. The measured parameters were the permeateflux, the quality of the permeate, as well as the fouling tendency of the membrane. A dynamic membrane or a cake layer forming on top of the membrane was observed to decrease the flux and increase separa-tion of certain substances, especially at low cross-flow velocities. When the cross-flow velocities were increased the membrane properties became more important. Backflushing could also be used to decrease the thickness of the cake layer and thus it improved the permeate flux. However, backflushing can lead to a reduction of retentions in cases where the cake layer is improving them. The wastewater quality was important for the thickness of the dynamic membrane and the membrane pore size influenced the permeate flux. In general, the optimization of operation conditions is very important for the successful operation of a membrane filtration system. The filtration equipment with a reasonable range of operational conditions is necessary, especiallywhen different kinds of wastewaters are treated. This should be taken into account already in the development stage of a filtration equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis different parameters influencing critical flux in protein ultrafiltration and membrane foul-ing were studied. Short reviews of proteins, cross-flow ultrafiltration, flux decline and criticalflux and the basic theory of Partial Least Square analysis (PLS) are given at the beginning. The experiments were mainly performed using dilute solutions of globular proteins, commercial polymeric membranes and laboratory scale apparatuses. Fouling was studied by flux, streaming potential and FTIR-ATR measurements. Critical flux was evaluated by different kinds of stepwise procedures and by both con-stant pressure and constant flux methods. The critical flux was affected by transmembrane pressure, flow velocity, protein concentration, mem-brane hydrophobicity and protein and membrane charges. Generally, the lowest critical fluxes were obtained at the isoelectric points of the protein and the highest in the presence of electrostatic repulsion between the membrane surface and the protein molecules. In the laminar flow regime the critical flux increased with flow velocity, but not any more above this region. An increase in concentration de-creased the critical flux. Hydrophobic membranes showed fouling in all charge conditionsand, furthermore, especially at the beginning of the experiment even at very low transmembrane pressures. Fouling of these membranes was thought to be due to protein adsorption by hydrophobic interactions. The hydrophilic membranes used suffered more from reversible fouling and concentration polarisation than from irreversible foul-ing. They became fouled at higher transmembrane pressures becauseof pore blocking. In this thesis some new aspects on critical flux are presented that are important for ultrafiltration and fractionation of proteins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hemicelluloses are among the most important natural resources that contain polysaccharides. In this study the separation and purification of hemicelluloses from water extraction liquors containing wood hemicelluloses, lignin compounds and monosaccharide by using membrane filtration was investigated. The isolation of the hemicelluloses from the wood hydrolysates was performed in two steps: concentration of high molar mass hemicelluloses by ultrafiltration and separation of low molar mass hemicelluloses from monomeric sugars using tight ultrafiltration membranes. The purification of the retained hemicelluloses was performed by diafiltration. During the filtration experiments, the permeate flux through ultrafiltration and tight ultrafiltration membranes was relatively high. The fouling ability of the used membranes was relatively low. In our experiments, the retention of hemicelluloses using two filtration steps was almost complete. The separation of monosaccharides from hemicelluloses was relatively high and the purification of hemicelluloses by diafiltration was highly efficient. The separation of lignin from hemicelluloses was partially achieved. Diafiltration showed potential to purify retained hemicelluloses from lignin and other organics. The best separation of lignin from hemicelluloses in the first filtration step was obtained using the UC005 membrane. The GE-5 and ETNA01PP membranes showed potential to purify and separate lignin from hemicelluloses. However, the feed solution of the second filtration stages (from different ultrafiltration membranes) affected the permeate flux and the separation of various extracted compounds from hemicelluloses. The GE-5 and ETNA01PP membranes gave the efficient purification of the hemicelluloses when using diafiltration. Separation of degraded xylan from glucomannan (primary spruce hemicelluloses) was also possible using membrane filtration. The best separation was achieved using the GE-5 membrane. The retention of glucomannan was three times higher than xylan retention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nanofiltration performance was studied with effluents from the pulp and paper industry and with model substances. The effect of filtration conditions and membrane properties on nanofiltration flux, retention, and fouling was investigated. Generally, the aim was to determine the parameters that influence nanofiltration efficiency and study how to carry out nanofiltration without fouling by controlling these parameters. The retentions of the nanofiltration membranes studied were considerably higher than those of tight ultrafiltration membranes, and the permeate fluxes obtained were approximately the same as those of tight ultrafiltration membranes. Generally, about 80% retentions of total carbon and conductivity were obtained during the nanofiltration experiments. Depending on the membrane and the filtration conditions, the retentions of monovalent ions (chloride) were between 80 and 95% in the nanofiltrations. An increase in pH improved retentions considerably and also the flux to some degree. An increase in pressure improved retention, whereas an increase in temperature decreased retention if the membrane retained the solute by the solution diffusion mechanism. In this study, more open membranes fouled more than tighter membranes due to higher concentration polarization and plugging of the membrane material. More irreversible fouling was measured for hydrophobic membranes. Electrostatic repulsion between the membrane and the components in the solution reduced fouling but did not completely prevent it with the hydrophobic membranes. Nanofiltration could be carried out without fouling, at least with the laboratory scale apparatus used here when the flux was below the critical flux. Model substances had a strong form of the critical flux, but the effluents had only a weak form of the critical flux. With the effluents, some fouling always occurred immediately when the filtration was started. However, if the flux was below the critical flux, further fouling was not observed. The flow velocity and pH were probably the most important parameters, along with the membrane properties, that influenced the critical flux. Precleaning of the membranes had only a small effect on the critical flux and retentions, but it improved the permeability of the membranes significantly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Membrane bioreactors (MBRs) are a combination of activated sludge bioreactors and membrane filtration, enabling high quality effluent with a small footprint. However, they can be beset by fouling, which causes an increase in transmembrane pressure (TMP). Modelling and simulation of changes in TMP could be useful to describe fouling through the identification of the most relevant operating conditions. Using experimental data from a MBR pilot plant operated for 462days, two different models were developed: a deterministic model using activated sludge model n°2d (ASM2d) for the biological component and a resistance in-series model for the filtration component as well as a data-driven model based on multivariable regressions. Once validated, these models were used to describe membrane fouling (as changes in TMP over time) under different operating conditions. The deterministic model performed better at higher temperatures (>20°C), constant operating conditions (DO set-point, membrane air-flow, pH and ORP), and high mixed liquor suspended solids (>6.9gL-1) and flux changes. At low pH (<7) or periods with higher pH changes, the data-driven model was more accurate. Changes in the DO set-point of the aerobic reactor that affected the TMP were also better described by the data-driven model. By combining the use of both models, a better description of fouling can be achieved under different operating conditions

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5mgO2L-1 and a membrane specific aeration demand (SADm) of 1mh-1, where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1mh-1 doubled the values of transmembrane pressure, without recovery after achieving the initial conditions

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interest in recovery of valuable components from process streams has increased in recent years. Purpose of biorefinery is to utilize components that otherwise would go to waste. Hemicelluloses, for example, could be utilized in production of many valuable products. One possible way to separate and fractionate hemicelluloses is membrane filtration. In the literature part of this work membrane fouling in filtration processes of pulp and paper process- and wastewaters was investigated. Especially purpose was to find out the possible fouling compounds, after which facilities to remove or modify such components less harmful were studied. In the experimental part different pretreatment methods, mainly to remove or degrade lignin from wood hydrolysate, were studied. In addition, concentration of hemicelluloses and separation from lignin were examined with two ultrafiltration membranes; UFX5 and RC70PP. Changes in feed solution, filtration capacity and fouling of membranes were used to evaluate the effects of pretreatment methods. Changes in hydrolysate composition were observed with different analysis methods. Filtration of hydrolysate proved to be challenging, especially with the UFX5 membrane. The more hydrophilic RC70PP membrane did not seem to be fouled as severely as the UFX5 membrane, according to pure water flux measurements. The UFX5 membrane retained hemicelluloses rather well, but problems arose from rapid flux decline resulting from concentration polarization and fouling of membrane. Most effective pretreatment methods in the case with the UFX5 membrane proved to be prefiltration with the RC70PP membrane, activated carbon adsorption and photocatalytic oxidation using titanium dioxide and UV radiation. An additional experiment with PHW extract showed that pulsed corona discharge treatment degraded lignin quite efficiently and thus improved filtration capacity remarkably, even over six times compared to the filtration with untreated extract.