883 resultados para Force platform
Resumo:
Given the important role of the shoulder sensorimotor system in shoulder stability, its assessment appears of interest. Force platform monitoring of centre of pressure (CoP) in upper-limb weight-bearing positions is of interest as it allows integration of all aspects of shoulder sensorimotor control. This study aimed to determine the feasibility and reliability of shoulder sensorimotor control assessment by force platform. Forty-five healthy subjects performed two sessions of CoP measurement using Win-Posturo(®) Medicapteurs force platform in an upper-limb weight-bearing position with the lower limbs resting on a table to either the anterior superior iliac spines (P1) or upper patellar poles (P2). Four different conditions were tested in each position in random order: eyes open or eyes closed with trunk supported by both hands and eyes open with trunk supported on the dominant or non-dominant side. P1 reliability values were globally moderate to high for CoP length, CoP velocity and CoP standard deviation (SD), standard error of measurement ranged from 6·0% to 26·5%, except for CoP area. P2 reliability values were globally low and not clinically acceptable. Our results suggest that shoulder sensorimotor control assessment by force platform is feasible and has good reliability in upper-limb weight-bearing positions when the lower limbs are resting on a table to the anterior superior iliac spines. CoP length, CoP velocity and CoP SD velocity appear to be the most reliable variables.
Resumo:
Poor posture control has been associated with an increased risk of falls and mobility disability among older adults. This study was conducted to assess the test-retest reliability and sensitivity to group differences regarding the time-limit (TLimit) of one-leg standing and selected balance parameters obtained with a force platform in older and young adults. A secondary purpose was to assess the relationship between TLimit and these balance parameters. Twenty-eight healthy older adults (age: 69±5years) and thirty young adults (age: 21±4years) participated in this study. Two one-leg stance tasks were performed: (1) three trials of 30s maximum and (2) one TLimit trial. The following balance parameters were computed: center of pressure area, RMS sway amplitude, and mean velocity and mean frequency in both the anterio-posterior and medio-lateral directions. All balance parameters obtained with the force platform as well as the TLimit variable were sensitive to differences in balance performance between older and young adults. The test-retest reliability of these measures was found to be acceptable (ICC: 0.40-0.85), with better ICC scores observed for mean velocity and mean frequency in the older group. Pearson correlations coefficients (r) between balance parameters and TLimit ranged from -0.16 to -0.54. These results add to the current literature that can be used in the development of measurement tools for evaluating balance in older and young adults. © 2013 Elsevier Ltd.
Resumo:
The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.
Resumo:
8 men artistic gymnasts were evaluated with a new test protocol in order to assess isometric strength in an specific hold position on still rings. The proposed test protocol measures the force applied the gymnast on the rings from an initial lying prone position on a force platform while he is trying to achieve the Swallow (or Hirondelle) position. The vertical force (FZ) from the forcetime curve registered (100 Hz) was used and it showed a descent from the initial body weight level caused by the gymnast force on the rings and, later, a maximal isometric force period. Fundamental and derivate variables to extract from the evolution of Fz were defined. Results showed significant statistical differences between gymnasts that could perform the Swallow (P) from those that could not (NP) (pmenor que0.05). Performer gymnasts were characterized by a higher percentage of body weight descent and higher strength in relation to body mass (pmenor que0.05). The practical application of this tool could be to provide coaches with information about how close the gymnast is to perform the Swallow.
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
The aim of this study was to test if the critical power model can be used to determine the critical rest interval (CRI) between vertical jumps. Ten males performed intermittent countermovement jumps on a force platform with different resting periods (4.1 +/- 0.3 s, 5.0 +/- 0.4 s, 5.9 +/- 0.6 s). Jump trials were interrupted when participants could no longer maintain 95% of their maximal jump height. After interruption, number of jumps, total exercise duration and total external work were computed. Time to exhaustion (s) and total external work (J) were used to solve the equation Work = a + b . time. The CRI (corresponding to the shortest resting interval that allowed jump height to be maintained for a long time without fatigue) was determined dividing the average external work needed to jump at a fixed height (J) by b parameter (J/s). in the final session, participants jumped at their calculated CRI. A high coefficient of determination (0.995 +/- 0.007) and the CRI (7.5 +/- 1.6 s) were obtained. In addition, the longer the resting period, the greater the number of jumps (44 13, 71 28, 105 30, 169 53 jumps; p<0.0001), time to exhaustion (179 +/- 50, 351 +/- 120, 610 +/- 141, 1,282 +/- 417 s; p<0.0001) and total external work (28.0 +/- 8.3, 45.0 +/- 16.6, 67.6 +/- 17.8, 111.9 +/- 34.6 kJ; p<0.0001). Therefore, the critical power model may be an alternative approach to determine the CRI during intermittent vertical jumps.
Resumo:
The purpose of this study was to investigate whether the additional sensory information could improve postural control in individuals with unilateral anterior cruciate ligament (ACL) injury. Twenty-eight individuals with unilateral ACL injury (mean age 23.6, 26 males, 2 females) and 28 healthy young control subjects (mean age 22.1 years, 26 males, 2 females) participated in this study. Postural control was evaluated with subjects single-leg standing on a force platform with eyes closed under two sensory conditions: normal sensory information and light touch to a stationary bar (applied force below 1 N). Three trials of 30 5 were performed in each single-leg stance and in each sensory condition. Mean sway amplitude and predominant frequency of center of pressure were calculated for both anterior-posterior and medial-lateral directions. Individuals with ACL injury showed greater mean sway amplitude than healthy control individuals even though the predominant frequency was similar for both groups. Additional sensory information improved postural control performance in individuals with ACL injury and healthy control, with a greater effect observed for the ACL group. Based on these results, we suggest that reduction in postural control performance in individuals with ACL injury would be due to the reduction of sensory information provided by the ACL, but when sensory information is enhanced, postural control performance improves. These results have implications for novel approaches to improve stability in individuals with ACL injury. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives: (a) To compare the magnitude of gluteus medius and tensor fascia lata activation between a group of subjects with clinical unilateral hip osteoarthritis and a group of healthy older adults. (b) To compare the magnitude of activation of the gluteus medius and tensor fascia lata between sides in a group of subjects with clinical unilateral hip osteoarthritis and a group of healthy older adults. Methods: 19 subjects with clinical unilateral hip osteoarthritis and 19 healthy controls were investigated. The subjects performed a stepping task during which recordings were obtained using surface electromyograms from the hip abductors, and kinetic data were obtained from a dual force platform. Results: Subjects with clinical hip osteoarthritis had higher gluteus medius activation than the healthy older adults (p=0.037). In addition, there were no differences in the magnitude of gluteus medius activation between the sides (p=0.733). There was no difference in the force platform data between the groups (p=0.078). Conclusions: The increased magnitude of gluteus medius activation in the group with hip osteoarthritis is evidence of a muscular dysfunction associated with hip disease. This has implications for the progressive nature of the disease and for its conservative management.
Resumo:
O equilíbrio é fundamental para o desempenho de Actividades de Vida Diária e de Vida Diária Instrumentais que permitem aos indivíduos com Síndrome de Down manter a sua autonomia. O objectivo principal deste estudo foi verificar as características do estado de equilíbrio em indivíduos com e sem Síndrome de Down, em repouso e durante a execução de uma tarefa, de modo a compreender as implicações da alteração do estado de equilíbrio no desempenho de actividades. Neste estudo, foram seleccionadas duas amostras, de forma probabilística por conveniência, com indivíduos de ambos os sexos. A amostra do grupo experimental foi constituída por oito indivíduos com diagnóstico de Síndrome de Down, com idades compreendidas entre os 17 e os 39 anos de idade. A amostra do grupo de controlo foi constituída por doze indivíduos sem patologia, com idades compreendidas entre os 21 e os 37 anos. O equilíbrio foi avaliado com recurso a uma Plataforma de Forças (Bertec Corporation FP4060-10) para medir a deslocação do centro de pressão (CP) dos indivíduos. A avaliação do equilíbrio decorreu em dois momentos, na posição de pé: em repouso e no desempenho da tarefa segurar um saco de compras. Os resultados diferem entre os dois grupos em repouso e durante a execução da tarefa (segurar no saco). Os valores das variáveis área e distância de deslocação do CP e oscilações corporais, antero-posterior e médio-lateralmente apresentam resultados significativos, o que sugere diferenças do estado de equilíbrio entre as amostras.
Resumo:
Introdução: A iniciação da marcha, enquanto tarefa motora complexa que consiste na transição de uma postura mantida pelo apoio simultâneo dos dois membros inferiores para um equilíbrio dinâmico, permitindo a progressão anterior do corpo, constitui um exemplo que implica uma correta sequência de ativação muscular. Objetivos: Verificar a modificação da fase de iniciação da marcha face à aplicação de um programa de recuperação funcional, analisando a sequência de ativação dos músculos tibial anterior e solear. Registar as repercussões funcionais na participação nas diferentes atividades da vida diária, em contexto padronizado e social. Metodologia: Nos dois participantes em estudo foi realizada uma avaliação antes e após um programa de intervenção, segundo a abordagem do Conceito de Bobath, através da Classificação Internacional de Funcionalidade, Incapacidade e Saúde, da Fugl Meyer Assessment of Sensorymotor Recovery After Stroke, electromiografia e plataforma de forças. Resultados: Após a aplicação do programa de recuperação funcional, verificaram-se alterações na sequência de ativação do tibial anterior e solear. O músculo tibial anterior passou a ser o primeiro a ser recrutado nesta sequência. Conclusão: Foi possível verificar modificações durante a fase de iniciação da marcha, face a um programa de recuperação funcional, em que a sequência de ativação do tibial anterior e solear, tendencialmente, se assemelharam ao comportamento em indivíduos saudáveis, repercutindo-se numa melhoria funcional na participação nas atividades da vida diária.
Resumo:
O objectivo deste estudo foi estudar o comportamento do tronco inferior antes e após um período de 4 meses de intervenção. Para isso avaliaram-se os ajustes posturais antecipatórios durante um movimento voluntário, realizado na posição de pé, recorreu-se à electromiografia para avaliar a actividade muscular da musculatura focal e postural e plataforma de forças para estimar a migração do CP. A amostra foi constituída por duas crianças de 6 e 8 anos, com o mesmo quadro motor, diplegia. Ambas são pré termo de 31 e 32 semanas de gestação e com lesão por LPV. Verificou-se que ambos activaram os paravertebrais, antes do deltóide anterior, no período antecipatório, mas não os abdominais. O CP deslocou-se posteriormente. Após intervenção os tempos de activação dos abdominais e o deslocamento do CP eram mais curtos. Foi demonstrado que melhorou a capacidade de activação da musculatura ventral após o período de intervenção.
Resumo:
PURPOSE: To analyze and compare the Ground Reaction Forces (GRF), during the stance phase of walking in pregnant women in the 3rd trimester of pregnancy, and non pregnant women. METHODS: 20 women, 10 pregnant and 10 non pregnant, voluntarily took part in this study. GRF were measured (1000 Hz) using a force platform (BERTEC 4060-15), an amplifier (BERTEC AM 6300) and an analogical-digital converter of 16 Bits (Biopac). RESULTS: The study showed that there were significant differences among the two groups concerning absolute values of time of the stance phase. In what concerns to the normalized values the most significant differences were verified in the maximums values of vertical force (Fz3, Fz1) and in the impulse of the antero-posterior force (Fy2), taxes of growth of the vertical force, and in the period of time for the antero-posterior force (Fy) be null. CONCLUSIONS: It is easier for the pregnant to continue forward movement (push-off phase). O smaller growth rates in what concerns to the maximum of the vertical force (Fz1) for the pregnant, can be associated with a slower speed of gait, as an adaptation strategy to maintain the balance, to compensate the alterations in the position of her center of gravity due to the load increase. The data related to the antero-posterior component of the force (Fy), shows that there is a significant difference between the pregnant woman’s left foot and right foot, which accuses a different functional behavior in each one of the feet, during the propulsion phase (TS).
Resumo:
Objectivo: Analisar a variação do centro de pressão (CP) com a utilização do calçado MBT, no equilíbrio estático a curto e longo prazo. Metodologia: A amostra é constituída por dois grupos, experimental e controlo. O estudo consistiu em dois momentos de avaliação, na recolha os indivíduos estão sobre a plataforma, estáticos. Os dados recolhidos foram a área, distância e velocidade das oscilações do CP. Resultados: As variáveis estudadas estão aumentadas com o uso das MBT. A longo prazo não se verificou diferenças significativas entre os grupos. Conclusão: As sapatilhas MBT proporcionam o aumento das oscilações do CP a curto prazo.
Resumo:
As sapatilhas MBT combinam um aumento da actividade muscular dos membros inferiores com a marcha. Objectivo: Analisar influência das MBT na actividade electromiográfica do tibial anterior, gastrocnémio medial, recto femoral e bicípite femoral na fase de apoio. Metodologia: A amostra constitui-se por 30 indivíduos. Utilizou-se electromiografia de superfície e plataforma de forças. Resultados: Foram encontradas diferenças no tempo de início de activação do gastrocnémio medial (p <0,0001) e nas sequências de início de actividade (p =0,007). Conclusão: O uso das MBT diminui o tempo de início da actividade do gastrocnémio medial e altera as sequências de início de actividade.
Resumo:
Mestrado em Fisioterapia.