987 resultados para Force Measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study deals with the determination of the retentive forces of telescopic crowns measured extra- and intra-orally and the correlation of these values.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Force measurement in hypervelocity expansion tubes is not possible using conventional techniques. The stress wave force balance technique can be applied in expansion tubes to measure forces despite the short test times involved. This paper presents a new calibration technique for multiple-component stress wave force balances where an impulse response created using a load distribution is required and no orthogonal surfaces on the model exist.. This new technique relies on the tensorial superposition of single-component impulse responses analogous to the vectorial superposition of the calibration loads. The example presented here is that of a scale model of the Mars Pathfinder, but the technique is applicable to any geometry and may be useful for cases where orthogonal loads cannot be applied.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A combination of modelling and analysis techniques was used to design a six component force balance. The balance was designed specifically for the measurement of impulsive aerodynamic forces and moments characteristic of hypervelocity shock tunnel testing using the stress wave force measurement technique. Aerodynamic modelling was used to estimate the magnitude and distribution of forces and finite element modelling to determine the mechanical response of proposed balance designs. Simulation of balance performance was based on aerodynamic loads and mechanical responses using convolution techniques. Deconvolution was then used to assess balance performance and to guide further design modifications leading to the final balance design. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A 1000-kgf resistive strain-gauge load cell has been developed for quality testing of rocket propellant grain. A 7075-T6 aluminum alloy has been used for the elastic column, in which 8 uniaxial, 120-Ω strain gauges have been bonded and connected to form a full Wheatstone bridge to detect the strain. The chosen geometry makes the transducer insensitive to moments and, also, to the temperature. Experimental tests using a universal testing machine to imposed compression force to the load cell have demonstrated that its behavior is linear, with sensitivity of 2.90 μV/kgf ± 0.34%, and negligible hysteresis. The designed force transducer response to a dynamic test has been comparable to that of a commercial load cell. © 2005 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The delicate anatomy of the ear require surgeons to use great care when operating on its internal structures. One example for such an intervention is the stapedectomy, where a small crook shaped piston is placed in the oval window of the cochlea and connected to the incus through crimping thus bypassing the diseased stapes. Performing the crimp process with the correct force is necessary since loose crimps poorly transmit sound whereas tight crimps will eventually result in necrosis of the incus. Clinically, demand is high to reproducibly conduct the crimp process through a precise force measurement. For this reason, we have developed a fiber Bragg grating (FBG) integrated microforceps for use in such interventions. This device was calibrated, and tested in cadaver preparations. With this instrument we were able to measure for the first time forces involved in crimping a stapes prosthesis to the incus. We also discuss a method of attaching and actuating such forceps in conjunction with a robot currently under development in our group. Each component of this system can be used separately or combined to improve surgical accuracy, confidence and outcome.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

One of the most important design constraints of a climbing robot is its own weight. When links or legs are used as a locomotion system they tend to be composed of special lightweight materials, or four-bars-linkage mechanisms are designed to reduce the weight with small rigidity looses. In these cases, flexibility appears and undesirable effects, such as dynamics vibrations, must be avoided at least when the robot moves at low speeds. The knowledge of the real tip position requires the computation of its compliance or stiffness matrix and the external forces applied to the structure. Gravitational forces can be estimated, but external tip forces need to be measured. This paper proposes a strain gauge system which achieves the following tasks: (i) measurement of the external tip forces, and (ii) estimation of the real tip position (including flexibility effects). The main advantages of the proposed system are: (a) the use of external force sensors is avoided, and (b) a substantial reduction of the robot weight is achieved in comparison with other external force measurement systems. The proposed method is applied to a real symmetric climbing robot and experimental results are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The potential of digital holography for complex manipulation of micron-sized particles with optical tweezers has been clearly demonstrated. By contrast, its use in quantitative experiments has been rather limited, partly due to fluctuations introduced by the spatial light modulator (SLM) that displays the kinoforms. This is an important issue when high temporal or spatial stability is a concern. We have investigated the performance of both an analog-addressed and a digitally-addressed SLM, measuring the phase fluctuations of the modulated beam and evaluating the resulting positional stability of a holographic trap. We show that, despite imparting a more unstable modulation to the wavefront, our digitally-addressed SLM generates optical traps in the sample plane stable enough for most applications. We further show that traps produced by the analog-addressed SLM exhibit a superior pointing stability, better than 1 nm, which is comparable to that of non-holographic tweezers. These results suggest a means to implement precision force measurement experiments with holographic optical tweezers (HOTs).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a dual-trap optical tweezers setup which directly measures forces using linear momentum conservation. The setup uses a counter-propagating geometry, which allows momentum measurement on each beam separately. The experimental advantages of this setup include low drift due to all-optical manipulation, and a robust calibration (independent of the features of the trapped object or buffer medium) due to the force measurement method. Although this design does not attain the high-resolution of some co-propagating setups, we show that it can be used to perform different single molecule measurements: fluctuation-based molecular stiffness characterization at different forces and hopping experiments on molecular hairpins. Remarkably, in our setup it is possible to manipulate very short tethers (such as molecular hairpins with short handles) down to the limit where beads are almost in contact. The setup is used to illustrate a novel method for measuring the stiffness of optical traps and tethers on the basis of equilibrium force fluctuations, i.e., without the need of measuring the force vs molecular extension curve. This method is of general interest for dual trap optical tweezers setups and can be extended to setups which do not directly measure forces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hitsatuilla rakenteilla väsyminen on keskeinen vauriotekijä. Väsymiskestoiän laskentaan on olemassa useita erilaisia menetelmiä, joista hot spot ﷓menetelmä on hitsattujen rakenteiden yhteydessä yhä yleistyvä ja sangen käyttökelpoinen. Hot spot menetelmässä kestoikälaskenta perustuu rakenteellisen jännityksen vaihteluun ja pieneen joukkoon kokeellisesti määrättyjä Wöhler-käyriä. Rakenteellinen jännitys voidaan määrittää joko prototyypistä mittaamalla, elementtimenetelmällä laskemalla tai parametristen kerrointen avulla. Suunnittelukäytännön kehittämisessä tutkittiin esimerkkirakenteena Rammer RC 22 leikkurimurskainta. Tarkoituksena oli mitata murskaimesta voimasuureita, joita voitaisiin käyttää kuormitustietona laskettaessa jännityksiä elementtimenetelmällä. Myöhempien laskentatulosten verifiointia varten mitattiin lisäksi muutamia hot spot ﷓jännityksiä. Työn kokeellinen puoli keskittyi voimasuuremittauksiin ja niistä saatavien tulosten saattamiseen sopusointuun vapaakappalemallien kanssa. Suoritettiin lukuisia kalibrointimittauksia ja mittausjärjestelyä kehitettiin, kunnes syyt aluksi saatujen mittaustulosten virheellisyyteen selvisivät. Leikkausvoimamittausten osalta tuloksia verifioitiin elementtimenetelmälaskelmin. Työn tuloksena saatiin luotua toimiva pohja voimasuure- ja hot spot ﷓mittauksille. Jatkossa voidaan siirtyä tekemään mittauksia todellisissa työskentelytilanteissa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hissiteollisuudessa nostokoneistoina käytettyjen sähkömoottoreiden laatuvaatimukset ovat tiuken-tuneet viime vuosina. Erityisesti koneistojen tuottama ääni ja mekaaninen värähtely ovat olleet jat-kuvasti tiukentuneen tarkastelun alaisena. Hissikoriin ja hissiä ympäröiviin rakenteisiin välittyvästä värähtelystä johtuva ääni on yksi hissin laatuvaikutelmaan merkittävimmin vaikuttavia tekijöitä. Nostokoneisto on yksi tärkeimmistä äänen ja värähtelyn lähteistä hissijärjestelmässä. Koneiston suunnittelulla edellä mainittuja tekijöitä voidaan minimoida. Sähkökoneiden suunnittelussa finiit-tielementtimenetelmien (FEM) käyttö on vakiintunut haastavimmissa sovelluksissa. Kone Oyj:llä nostokoneistoina käytetään aksiaalivuokestomagneettitahtikoneita (AFPMSM), joiden FEM simu-lointiin käytetään yleisesti kolmea eri tapaa. Kukin näistä vaihtoehdoista pitää sisällään omat hyö-tynsä, että haittansa. Suunnittelun kannalta tärkeää on oikean menetelmän valinta ai-ka/informatiivisuus suhteen maksimoimiseksi. Erittäin tärkeää on myös saatujen tulosten oikeelli-suus. Tämän diplomityön tavoite on kehittää järjestelmä, jonka avulla AFPMS-koneen voimia voidaan mitata yksityiskohtaisella tasolla. Järjestelmän avulla voidaan tarkastella käytössä olevien FE-menetelmien tulosten oikeellisuutta sekä äänen että värähtelyn syntymekanismeja. Järjestelmän tarkoitus on myös syventää Kone Oyj tietotaitoa AFPMS-koneiden toiminnasta. Tässä työssä esitellään AFPMS-koneen epäideaalisuuksia, jotka voivat vaikuttaa mittajärjestelmän suunnitteluun. Myös koneen epäideaalisuuksiin lukeutuvaa ääntä on tarkasteltu tässä työssä. Jotta työn tavoitteiden mukaista FE-menetelmien vertailua ja tulosten oikeellisuuden tarkastelua voitai-siin tehdä, myös yleisimpiä AFPMS-koneen FE-menetelmiä tarkastellaan. Työn tuloksena on mittajärjestelmän suunnitelma, jonka avulla voidaan toteuttaa kuuden vapausas-teen voimamittaus jokaiselle koneistomagneetille alle 1N resoluutiolla. Suunnitellun järjestelmän toimivuutta on tarkasteltu FE-menetelmiä käyttäen ja järjestelmässä käytettävän voima-anturin ky-vykkyyttä on todennettu referenssimittauksin. Suunniteltu mittajärjestelmä mahdollistaa sähkömoottorin useiden eri epäideaalisuuksien tarkaste-lun yksityiskohtaisella tasolla. Mittausajatuksen soveltaminen myös muiden koneiden tutkimiseen tarjoaa mahdollisuuksia jatkotutkimuksille.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Oscillatory contractile activity is an inherent property of blood vessels. Various cellular mechanisms have been proposed to contribute to oscillatory activity. Mouse small mesenteric arteries display a unique low frequency contractile oscillatory activity (1 cycle every 10-12 min) upon phenylephrine stimulation. Our objective was to identify mechanisms involved in this peculiar oscillatory activity. First-order mesenteric arteries were mounted in tissue baths for isometric force measurement. The oscillatory activity was observed only in vessels with endothelium, but it was not blocked by L-NAME (100 µM) or indomethacin (10 µM), ruling out the participation of nitric oxide and prostacyclin, respectively, in this phenomenon. Oscillatory activity was not observed in vessels contracted with K+ (90 mM) or after stimulation with phenylephrine plus 10 mM K+. Ouabain (1 to 10 µM, an Na+/K+-ATPase inhibitor), but not K+ channel antagonists [tetraethylammonium (100 µM, a nonselective K+ channel blocker), Tram-34 (10 µM, blocker of intermediate conductance K+ channels) or UCL-1684 (0.1 µM, a small conductance K+ channel blocker)], inhibited the oscillatory activity. The contractile activity was also abolished when experiments were performed at 20°C or in K+-free medium. Taken together, these results demonstrate that Na+/K+-ATPase is a potential source of these oscillations. The presence of α-1 and α-2 Na+/K+-ATPase isoforms was confirmed in murine mesenteric arteries by Western blot. Chronic infusion of mice with ouabain did not abolish oscillatory contraction, but up-regulated vascular Na+/K+-ATPase expression and increased blood pressure. Together, these observations suggest that the Na+/K+ pump plays a major role in the oscillatory activity of murine small mesenteric arteries.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Throughout the industrial processes of sheet metal manufacturing and refining, shear cutting is widely used for its speed and cost advantages over competing cutting methods. Industrial shears may include some force measurement possibilities, but the force is most likely influenced by friction losses between shear tool and the point of measurement, and are in general not showing the actual force applied to the sheet. Well defined shears and accurate measurements of force and shear tool position are important for understanding the influence of shear parameters. Accurate experimental data are also necessary for calibration of numerical shear models. Here, a dedicated laboratory set-up with well defined geometry and movement in the shear, and high measurability in terms of force and geometry is designed, built and verified. Parameters important to the shear process are studied with perturbation analysis techniques and requirements on input parameter accuracy are formulated to meet experimental output demands. Input parameters in shearing are mostly geometric parameters, but also material properties and contact conditions. Based on the accuracy requirements, a symmetric experiment with internal balancing of forces is constructed to avoid guides and corresponding friction losses. Finally, the experimental procedure is validated through shearing of a medium grade steel. With the obtained experimental set-up performance, force changes as result of changes in studied input parameters are distinguishable down to a level of 1%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)