203 resultados para Flushing
Resumo:
Resumo: O objetivo deste estudo foi realizar uma análise econômica do protocolo de sincronização do estro mais a ração flushing oferecida as cabras durante a estação de monta. Foram selecionadas 12 cabras da raça Saanen e um reprodutor, recebendo ração flushing. Utilizou-se esponjas análogas a progesterona, Prostaglandina e Gonadotrofina Coriônica Equina. O custo total foi de R$ 46, 17/animal. A utilização da sincronização torna-se uma medida viável economicamente quando comparada a monta natural. [Economic analisy on station of sum to Saanen goats using protocol of synchronization of estrous and flushing ration]. Abstract: The aim of the experimente was to realize na economic analysis of protocol synchronization of estrous and flushing ration offered to Saanen breed goats during station of sum. Twelve Saanen breed goats and onde billy-goat were used. Intravaginal sponges containing progesterone, Prostaglandin and Equine Corionic Gonadotroohin were used. The total costs were R$ 46,17/animal. The use of protocol of sychronization of estrous is more economically viable the sum natural.
Resumo:
The velocity of dripline flushing in subsurface drip irrigation (SDI) systems affects system design, cost, management, performance, and longevity. A 30‐day field study was conducted at Kansas State University to analyze the effect of four targeted flushing velocities (0.23, 0.30, 0.46, and 0.61 m/s) for a fixed 15 min duration of flushing and three flushing frequencies (no flushing or flushing every 15 or 30 days) on SDI emitter discharge and sediments within the dripline and removed in the flushing water. At the end of the field experiment (371 h), the amount of solids carried away by the flushing water and retained in every lateral were determined as well as laboratory determination of emitter discharge for every single emitter within each dripline. Greater dripline flushing velocities, which also resulted in greater flushing volumes, tended to result in greater amounts of solids in the flushing water, but the differences were not always statistically significant. Neither the frequency of flushing nor the interaction of flushing frequency and velocity significantly affected the amount of solids in the flushing water. There was a greater concentration of solids in the beginning one‐third of the 90 m laterals, particularly for treatments with no flushing or with slower dripline flushing velocities. As flushing velocity and concurrently flushing volume increased, there was a tendency for greater solids removal and/or more equal distribution within the dripline. At the end of the field study, the average emitter discharge as measured in the laboratory for a total of 3970 emitters was 0.64 L/h. which was significantly less (approximately 2.5%) than the discharge for new and unused emitters. Only six emitters were nearly or fully clogged, with discharges between 0% and 5% of new and unused emitters. Flushing velocity and flushing frequency did not have consistent significant effects on emitter discharge, and those numerical differences that did exist were small (<3%). Emitter discharge was approximately 3% less for the distal ends of the driplines (last 20% of the dripline). Although not a specific factor in the study, the results of solids removals during flushing and solids retention within the different dripline sections suggest that duration of flushing may be a more cost‐effective management option than increasing the dripline flushing velocity through SDI system design. Finally, although microirrigation system components have been improved over the years, the need for flushing to remove solids and reduce clogging potential has not been eliminated
Resumo:
Flushing is an important maintenance task that removes accumulated particles in microirrigation laterals that can help to reduce clogging problems. The effect of three dripline flushing frequency treatments (no flushing, one flushing at the end of each irrigation period, and a monthly flushing during the irrigation period) was studied in surface and subsurface drip irrigation systems that operated using a wastewater treatment plant effluent for three irrigation periods of 540 h each. The irrigation systems had two different emitters, one pressure compensating and the other not, both molded and welded onto the interior dripline wall, placed in laterals 87 meters long. Dripline flow of the pressure compensating emitter increased 8% over time, while in the nonpressure compensating emitter, dripline flow increased 25% in the surface driplines and decreased 3% in the subsurface driplines by the emitter clogging. Emitter clogging was affected primarily by the interactions between emitter location, emitter type, and flushing frequency treatment. The number of completely clogged emitters was affected by the interaction between irrigation system and emitter type. There was an average of 3.7% less totally clogged emitters in flushed surface driplines with the pressurecompensating emitter as compared to flushed subsurface laterals with the nonpressure compensating emitter
Resumo:
We investigate the spatial characteristics of urban-like canopy flow by applying particle image velocimetry (PIV) to atmospheric turbulence. The study site was a Comprehensive Outdoor Scale MOdel (COSMO) experiment for urban climate in Japan. The PIV system captured the two-dimensional flow field within the canopy layer continuously for an hour with a sampling frequency of 30 Hz, thereby providing reliable outdoor turbulence statistics. PIV measurements in a wind-tunnel facility using similar roughness geometry, but with a lower sampling frequency of 4 Hz, were also done for comparison. The turbulent momentum flux from COSMO, and the wind tunnel showed similar values and distributions when scaled using friction velocity. Some different characteristics between outdoor and indoor flow fields were mainly caused by the larger fluctuations in wind direction for the atmospheric turbulence. The focus of the analysis is on a variety of instantaneous turbulent flow structures. One remarkable flow structure is termed 'flushing', that is, a large-scale upward motion prevailing across the whole vertical cross-section of a building gap. This is observed intermittently, whereby tracer particles are flushed vertically out from the canopy layer. Flushing phenomena are also observed in the wind tunnel where there is neither thermal stratification nor outer-layer turbulence. It is suggested that flushing phenomena are correlated with the passing of large-scale low-momentum regions above the canopy.
Resumo:
The objective of the present study was to evaluate the effects of double uterine flushing on the recovery of embryos/ova in cattle. Two hundred and ten embryo recovery procedures were conducted using a double uterine flushing method, and the results were compared with 432 conventional single-flushing procedures. Cyclic Limousin (n = 403) and Guzera (n = 239) donor cows received an intravaginal progesterone releasing device and 2 mg of estradiol benzoate on Day 0. Between Days 5 and 9, donors received decreasing doses of FSH, which ranged from 200 to 300 IU (Bos indicus) and 300 to 500 IU (Bos taut-us). on the afternoon of Day 7, donors received an injection of 500 mu g cloprostenol and progesterone implants were removed 12 It later (morning of Day 8). Artificial insemination was performed between 14 and 26 h after first detection of behavioral estrus. Cows were randomly assigned to have embryos recovered by a double-flushing method (n = 210) or the conventional single-flushing procedure (n = 432). For the double-flushing procedure, after first flushing the whole uterus with 1 L of Dubelco's Phosphate Buffered Saline (DPBS), a Foley catheter was positioned in the uterine body to permit refilling of the uterus with fresh DPBS (80-150 mL). The catheter was closed with the plunger of a disposable 5 mL syringe, and the donors were allowed to rest in a holding area for 30 min. Thereafter, a second flush was performed to recover the solution remaining in the uterus. Animals from the control group were subjected to a single uterine flush. From 2 10 double-flushing procedures, 1409 viable embryos were recovered. In comparison, from 432 cows receiving the single-flushing procedure, 1993 embryos were recovered. Double flushing increased (P < 0.05) the number of embryos recovered per procedure compared to single flushing (6.7 +/- 0.4 versus 4.6 +/- 0.2, respectively; mean +/- S.E.M.). When double flushing was performed, average recovered embryos/ova increased (P < 0.05) from 8.3 +/- 0.4 to 12.7 +/- 0.7 in Limousin and from 7.9 to 11.5 in Guzera. Also, utilization of double flushing increased (P < 0.05) the number of viable embryos from 4.7 +/- 0.3 to 6.9 +/- 0.5 in Limousin and from 4.5 +/- 0.4 to 6.4 +/- 0.7 in Guzera. Mean total embryos/ova was similar (P > 0.05) between the control group and after the first uterine flushing in the double-flushing group; therefore, both flushings were conducted efficiently. In conclusion, double uterine flushing increased embryo recovery in cattle. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to analyze the effect of flushing on the reproductive performance of Morada Nova (MN) and Santa Inês (SI) ewes submitted to fixed time artificial insemination (TAI). Twenty seven SI and 24 MN supplemented with concentrate (1% of live weight, on average), for 75 days during the breeding season. After 30 days of supplementation, ewes were synchronized with the aid of a hormonal protocol (HP) based on progesterone, eCG and cloprostenol. The estrus observation was conducted at 12, 24, 36 and 48 h after the end of HP with the aid of two ruffians. TAI was done 55 h after the end of HP. From 20 to 45 days after the beginning of the HP ewes were exposed to rams (natural breeding). The pregnancy diagnosis was evaluated 70 days after TAI. We analyzed the weight, body condition score, estrus rate, pregnancy rate and prolificacy testing the effects of race, week of supplementation and body condition score class. The weight and body conditions of ewes varied according to the week of supplementation, with higher values in the first two weeks following TAI. The estrus rate was 88.2% and 43.2% of the ewes showed estrus up to 24 hours of the end of the HP. The pregnancy rate per TAI was 31.3% and the pregnancy rate after natural breeding was 50.0%. It was observed that body condition score classes interfered in pregnancy rates. There was a higher percentage of multiple births by pregnancy by TAI than by natural breeding. It was concluded that the flushing resulted in weight gain and better body conditions ensuring the standardization of the herd for breeding season, which therefore improved reproductive performance. The HP used advanced the onset of estrus and increased prolificacy, but was inefficient in the synchronization of woolless sheep.
Resumo:
Follicle flushing has been proved to be ineffective in polyfollicular in vitro fertilization. To analyze the effect of flushing in monofollicular in vitro fertilization we aspirated and then flushed the follicles in 164 cycles. Total oocyte yield/aspiration was 44.5% in the aspirate, 20.7% in the 1(st) flush, 10.4% in the 2(nd) flush and 4.3% in the 3(rd) flush. By flushing, the total oocyte yield increased (p < 0.01) by 80.9%, from 44.5 to 80.5%. The total transfer rate increased (p < 0.01) by 91.0%, from 20.1 to 38.4%. The results indicate that the oocyte yield and the number of transferable embryos can be increased significantly by flushing.
Resumo:
OBJECTIVE To evaluate differences in bacterial numbers, identity, and susceptibility in samples obtained from the tympanic cavity on entry (preflush) and after evacuation and lavage (postflush) and assess perioperative and empiric antimicrobial selection in dogs that underwent total ear canal ablation (TECA) with lateral bulla osteotomy (LBO) or reoperation LBO. DESIGN Prospective clinical study. ANIMALS 34 dogs. PROCEDURE TECA with LBO or reoperation LBO was performed on 47 ears. Pre- and postflush aerobic and anaerobic samples were obtained from the tympanic cavity. Isolates and antimicrobial susceptibility patterns were compared. RESULTS Different isolates (31/44 [70%] ears) and susceptibility patterns of isolate pairs (6/44 [14%] ears) were detected in pre- and postflush samples from 84% of ears. Evacuation and lavage of the tympanic cavity decreased the number of bacterial isolates by 33%. In 26% of ears, bacteria were isolated from post-flush samples but not preflush samples. Only 26% of isolates tested were susceptible to cefazolin. At least 1 isolate from 53% of dogs that received empirically chosen antimicrobials postoperatively was resistant to the selected drugs. Anaerobic bacteria were recovered from 6 ears. CONCLUSIONS AND CLINICAL RELEVANCE Accurate microbiologic assessment of the tympanic cavity should be the basis for selection of antimicrobials in dogs undergoing TECA with LBO. Bacteria remain in the tympanic cavity after evacuation and lavage. Cefazolin was a poor choice for dogs that underwent TECA with LBO, as judged on the basis of culture and susceptibility testing results.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
The New York Statesman was printed by William A. Mercein, for Carter & Prentiss, editors and proprietors, in 1824.
Resumo:
Water level and current measurements from two virtually enclosed South Pacific atolls, Manihiki and Rakahanga, support a new lagoon flushing mechanism which is driven by waves and modulated by the ocean tide for virtually enclosed atolls. This is evident because the lagoon water level remains above the ocean at all tidal phases (i.e., ruling out tidal flushing) and because the average lagoon water level rises significantly during periods with large waves. Hence, we develop a model by which the lagoons are flushed by waves pumping of ocean water into the lagoon and gravity draining water from the lagoon over the reef rim. That is, the waves on the exposed side push water into the lagoon during most of the tidal cycle while water leaves the lagoon on the protected side for most of the tidal cycle. This wave-driven through flow flushing is shown to be more efficient than alternating tidal flushing with respect to water renewal. Improved water quality should therefore be sought through enhancement of the natural wave pumping rather than by blasting deep channels which would change the system to an alternating tide-driven one.