934 resultados para Flush Speciation
Resumo:
While the feasibility of bottleneck-induced speciation is in doubt, population bottlenecks may still affect the speciation process by interacting with divergent selection. To explore this possibility, I conducted a laboratory speciation experiment using Drosophila pseudoobscura involving 78 replicate populations assigned in a two-way factorial design to both bottleneck (present vs. absent) and environment (ancestral vs. novel) treatments. Populations independently evolved under these treatments and were then tested for assortative mating and male mating success against their common ancestor. Bottlenecks alone did not generate any premating isolation, despite an experimental design that was conducive to bottleneck-induced speciation. Premating isolation also did not evolve in the novel environment treatment, neither in the presence nor absence of bottlenecks. However, male mating success was significantly reduced in the novel environment treatment, both as a plastic response to this environment and as a result of environment-dependent inbreeding effects in the bottlenecked populations. Reduced mating success of derived males will hamper speciation by enhancing the mating success of immigrant, ancestral males. Novel environments are generally thought to promote ecological speciation by generating divergent natural selection. In the current experiment, however, the novel environment did not cause the evolution of any premating isolation and it reduced the likelihood of speciation through its effects on male mating success.
Resumo:
Soluble organic matter derived from exotic Pinus species has been shown to form stronger complexes with iron (Fe) than that derived from most native Australian species. It has also been proposed that the establishment of exotic Pinus plantations in coastal southeast Queensland may have enhanced the solubility of Fe in soils by increasing the amount of organically complexed Fe, but this remains inconclusive. In this study we test whether the concentration and speciation of Fe in soil water from Pinus plantations differs significantly from soil water from native vegetation areas. Both Fe redox speciation and the interaction between Fe and dissolved organic matter (DOM) were considered; Fe - DOM interaction was assessed using the Stockholm Humic Model. Iron concentrations (mainly Fe 2+) were greatest in the soil waters with the greatest DOM content collected from sandy podosols (Podzols), where they are largely controlled by redox potential. Iron concentrations were small in soil waters from clay and iron oxide-rich soils, in spite of similar redox potentials. This condition is related to stronger sorption on to the reactive clay and iron oxide mineral surfaces in these soils, which reduces the amount of DOM available for electron shuttling and microbial metabolism, restricting reductive dissolution of Fe. Vegetation type had no significant influence on the concentration and speciation of iron in soil waters, although DOM from Pinus sites had greater acidic functional group site densities than DOM from native vegetation sites. This is because Fe is mainly in the ferrous form, even in samples from the relatively well-drained podosols. However, modelling suggests that Pinus DOM can significantly increase the amount of truly dissolved ferric iron remaining in solution in oxic conditions. Therefore, the input of ferrous iron together with Pinus DOM to surface waters may reduce precipitation of hydrous ferric oxides (ferrihydrite) and increase the flux of dissolved Fe out of the catchment. Such inputs of iron are most probably derived from podosols planted with Pinus.
Resumo:
This spreadsheet calculates carbonate speciation using carbonate equilibrium equations at standard conditions (T=25°C) with ionic strength corrections. The user will typically be able to calculate the different carbonate species by entering total alkalinity and pH. This spreadsheet contains additional tools to calculate the Langelier Index for calcium and the SAR of the water. Note that in this last calculation the potential for calcium precipitation is not taken into account. The last tool presented here is a carbonate speciation tool in open systems (e.g. open to the atmosphere) which takes into account atmospheric pressure.
Resumo:
Molecular and morphological data indicate that the pest thrips damaging Myoporum species in California and Hawai'i, Klambothrips myoporiMound and Morris, originated in Tasmania, Australia. This trans-Pacific dispersal presumably resulted from the international horticultural trade in Myoporum species. The data distinguish the pest from K. adelaideae sp.n. that induces leaf deformation on M. insulare along the coast of mainland Australia that is separated by ∼300km from Tasmania by the Bass Strait. K. myopori is more damaging to its non-native hosts in California and Hawai'i than to M. insulare in Tasmania, and further research is needed to determine if this is the result of release from its natural enemies. However, in certain areas of California, some Myoporum species are invasive weeds, and K. myopori may be considered an example of an accidental but beneficial introduction in this instance because of its detrimental impact on the plant species.
Resumo:
The effectiveness of structural elements employed for stormwater mitigation such as bioretention basins and constructed wetlands depend on the compatibility between their design specifications and actual stormwater quality and quantity characteristics. These structural elements are commonly designed to accommodate the initial portion of runoff considering the occurrence of first flush. Therefore, the effectiveness of stormwater quality treatment primarily depends on the in-depth knowledge of the first flush phenomenon and the ability to provide appropriate treatment. The current scientific knowledge relating to first flush is limited primarily due to research investigations being undertaken based on lumped rainfall and runoff parameters. This paper presents the outcomes of an in-depth study undertaken of the first flush phenomenon using a set of indicators which are not only innovative, but is also able to accurately represent the characteristics of the different sectors in a runoff hydrograph. The analysis undertaken confirmed that pollutant wash-off during the initial 10% of runoff volume was critical for the occurrence of first flush. Typically first flush was found to last up to 40% of the runoff volume. The study outcomes provide new knowledge to enhance the effectiveness of structural stormwater treatment measures.
Resumo:
The current state of knowledge in relation to first flush does not provide a clear understanding of the role of rainfall and catchment characteristics in influencing this phenomenon. This is attributed to the inconsistent findings from research studies due to the unsatisfactory selection of first flush indicators and how first flush is defined. The research study discussed in this thesis provides the outcomes of a comprehensive analysis on the influence of rainfall and catchment characteristics on first flush behaviour in residential catchments. Two sets of first flush indicators are introduced in this study. These indicators were selected such that they are representative in explaining in a systematic manner the characteristics associated with first flush. Stormwater samples and rainfall-runoff data were collected and recorded from stormwater monitoring stations established at three urban catchments at Coomera Waters, Gold Coast, Australia. In addition, historical data were also used to support the data analysis. Three water quality parameters were analysed, namely, total suspended solids (TSS), total phosphorus (TP) and total nitrogen (TN). The data analyses were primarily undertaken using multi criteria decision making methods, PROMETHEE and GAIA. Based on the data obtained, the pollutant load distribution curve (LV) was determined for the individual rainfall events and pollutant types. Accordingly, two sets of first flush indicators were derived from the curve, namely, cumulative load wash-off for every 10% of runoff volume interval (interval first flush indicators or LV) from the beginning of the event and the actual pollutant load wash-off during a 10% increment in runoff volume (section first flush indicators or P). First flush behaviour showed significant variation with pollutant types. TSS and TP showed consistent first flush behaviour. However, the dissolved fraction of TN showed significant differences to TSS and TP first flush while particulate TN showed similarities. Wash-off of TSS, TP and particulate TN during the first 10% of the runoff volume showed no influence from corresponding rainfall intensity. This was attributed to the wash-off of weakly adhered solids on the catchment surface referred to as "short term pollutants" or "weakly adhered solids" load. However, wash-off after 10% of the runoff volume showed dependency on the rainfall intensity. This is attributed to the wash-off of strongly adhered solids being exposed when the weakly adhered solids diminish. The wash-off process was also found to depend on rainfall depth at the end part of the event as the strongly adhered solids are loosened due to impact of rainfall in the earlier part of the event. Events with high intensity rainfall bursts after 70% of the runoff volume did not demonstrate first flush behaviour. This suggests that rainfall pattern plays a critical role in the occurrence of first flush. Rainfall intensity (with respect to the rest of the event) that produces 10% to 20% runoff volume play an important role in defining the magnitude of the first flush. Events can demonstrate high magnitude first flush when the rainfall intensity occurring between 10% and 20% of the runoff volume is comparatively high while low rainfall intensities during this period produces low magnitude first flush. For events with first flush, the phenomenon is clearly visible up to 40% of the runoff volume. This contradicts the common definition that first flush only exists, if for example, 80% of the pollutant mass is transported in the first 30% of runoff volume. First flush behaviour for TN is different compared to TSS and TP. Apart from rainfall characteristics, the composition and the availability of TN on the catchment also play an important role in first flush. The analysis confirmed that events with low rainfall intensity can produce high magnitude first flush for the dissolved fraction of TN, while high rainfall intensity produce low dissolved TN first flush. This is attributed to the source limiting behaviour of dissolved TN wash-off where there is high wash-off during the initial part of a rainfall event irrespective of the intensity. However, for particulate TN, the influence of rainfall intensity on first flush characteristics is similar to TSS and TP. The data analysis also confirmed that first flush can occur as high magnitude first flush, low magnitude first flush or non existence of first flush. Investigation of the influence of catchment characteristics on first flush found that the key factors that influence the phenomenon are the location of the pollutant source, spatial distribution of the pervious and impervious surfaces in the catchment, drainage network layout and slope of the catchment. This confirms that first flush phenomenon cannot be evaluated based on a single or a limited set of parameters as a number of catchment characteristics should be taken into account. Catchments where the pollutant source is located close to the outlet, a high fraction of road surfaces, short travel time to the outlet, with steep slopes can produce high wash-off load during the first 50% of the runoff volume. Rainfall characteristics have a comparatively dominant impact on the wash-off process compared to the catchment characteristics. In addition, the pollutant characteristics also should be taken into account in designing stormwater treatment systems due to different wash-off behaviour. Analysis outcomes confirmed that there is a high TSS load during the first 20% of the runoff volume followed by TN which can extend up to 30% of the runoff volume. In contrast, high TP load can exist during the initial and at the end part of a rainfall event. This is related to the composition of TP available for the wash-off.
Resumo:
Peripheral venous catheters (PVCs) are the simplest and most frequently used method for drug, fluid, and blood product administration in the hospital setting. It is estimated that up to 90% of patients in acute care hospitals require a PVC; however, PVCs are associated with inherent complications, which can be mechanical or infectious. There have been a range of strategies to prevent or reduce PVC-related complications that include optimizing patency through the use of flushing. Little is known about the current status of flushing practice. This observational study quantified preparation and administration time and identified adherence to principles of Aseptic Non-Touch Technique and organizational protocol on PVC flushing by using both manually prepared and prefilled syringes.
Resumo:
This study identified Gram-positive bacteria in three sub-tropical marine fish species: Pseudocaranx dentex (silver trevally), Pagrus auratus (snapper) and Mugil cephalus (sea mullet). It further elucidated the role played by fish habitat, fish body part and ambient storage on the composition of the Gram-positive bacteria. A total of 266 isolates of Gram-positive bacteria were identified by conventional biochemical methods, VITEK, PCR using genus- and species-specific primers and/or 16S rRNA gene sequencing. The isolates were found to fall into 13 genera and 30 species. In fresh fish, Staphylococcus epidermidis and Micrococcus luteus were the most frequent isolates. After ambient storage, S. epidermidis, S. xylosus and Bacillus megaterium were no longer present whereas S. warned, B. sphaericus, Brevibacillus borstelensis, Enterococcus faecium and Streptococcus uberis increased in frequency. Micrococcus luteus and S. warned were the most prevalent isolates from P. dentex, while E. faecium and Strep. uberis were the most frequent isolates from P. auratus and M. cephalus. With respect to different parts of the fish body. E. faecium, Strep. uberis and B. sphaericus were the most frequent isolates from the muscles, E. faecium, Strep. uberis from the gills and M. luteus from the gut. This study showed a diversity of Gram-positive bacteria in sub-tropical marine fish; however, their abundance was affected by fish habitat, fish body part and ambient storage.
Resumo:
Sustainable management of sea mullet (Mugil cephalus) fisheries needs to account for recent observations of regional-scale differentiation. Population genetic analysis is sought to assess the situation of this ecologically and economically important fish species in eastern Australian waters. Here, we report (i) new population genetic markers [single nucleotide polymorphisms (SNPs) and potential microsatellites], (ii) first estimates of spatial genetic differentiation and (iii) prospective power tests for designing more comprehensive studies. Six DNA samples from three sampling regions (North Queensland, South Queensland and central New South Wales) on the eastern coast of Australia were used to prepare restriction site associated DNA (RAD) tag libraries from genomic DNA digested with EcoRI and MseI. A pooled sample of regional RAD tag libraries was sequenced using the Roche GS-FLX Titanium platform. A total of 172837 raw reads (17.4Mbp) were retrieved, 95500 of which were used to discover 1267 SNPs and 1417 microsatellites. A subset of 161 SNPs was validated based on 63 additional DNA samples genotyped using the Sequenom MassArray (iPLEX Gold chemistry). Altogether 92 SNPs (57%) were confirmed, with 40% of these marking fixed variants between northern and southern sampling regions. Our preliminary findings indicate a multispecies fishery stock of M. cephalus in eastern Australian waters, but suggest that strong genetic differentiation occurs north of major fishing grounds. Low potential differentiation within major fishing grounds (e.g. FST=0.0025) can be resolved with a likely power 67% by using standard sample sizes of 50 and validated subsets of available markers.
Resumo:
Three-dimensional numerical study of natural convection in a vertical channel with flush-mounted discrete heaters on opposite conductive substrate walls is carried out in the present work. Detailed flow and heat transfer characteristics are presented for various Grashof numbers. The heat transfer effects on one wall by the presence of heaters on its opposite wall is examined. It is found that heat transfer rates on one wall are increased by the presence of heaters on its opposite wall. The thermal boundary layers on the opposite walls complement each other for enhanced heat transfer. The effects of spacing between the heated walls, spacings between heaters and substrate conductivity on flow and heat transfer are examined. Existence of optimum spacings between the heated walls for maximum heat transfer and mass flow are observed. It is found that the heat transfer and fluid flow do not follow the same optimum spacings. Mass flow rate reaches maximum value at a wall spacing greater than the spacing for maximum heat transfer. This is because the interaction of thermal boundary layers on individual walls ceases at a lower spacing before the velocity boundary layers separate each other. It is found that increased spacings between heaters reduce individual heater temperatures provided the heaters close to exit on both substrates avail sufficient substrate potions on the exit side. Insufficient substrate portions between the exit heaters and the exit cause abnormal local temperature rise in the exit heaters which are the hottest ones among all the heaters. Optimal heater spacings exist for minimum hottest heater temperature rise. Correlations are presented for dimensionless mass flow rate, temperature maximum, and average Nusselt number.
Resumo:
ENGLISH: The thread herrings, genus Opisthonema, family Clupeidae, are marine fishes that occur only in tropical and subtropical waters off both coasts of the American continent. The genus is composed of one Atlantic species and four Pacific species. Opisthonema oglinum (LeSueur), the single species in the western Atlantic Ocean, occurs from Brazil to Massachusetts, at Bermuda, and throughout the West Indies. Opisthonema libertate (Günther), Opisthonema bulleri (Regan), and Opisthonema medirastre, new species, are Pacific coastal species which occur together from Peru to Mexico (with at least one occasionally in California). Opisthonema berlangai, new species, is confined to the vicinity of the Galapagos Islands. SPANISH: Los arenques de hebra, género Opisthonema, familia Clupeidae, son peces marinos que se encuentran sólo en aguas tropicales y subtropicales cerca a ambas costas del continente americano. El género está compuesto de una especie en el Atlántico y de cuatro en el Pacifico. Opisthonema oglinum (LeSueur), única especie que medra el Océano Atlántico occidental, se encuentra del Brasil a Massachusetts, en Bermuda, y las Indias Occidentales. Opisthonema libertate (Günther), Opisthonema bulleri (Regan), y Opisthonema medirastre, especie nueva, son especies costaneras del Pacífico que aparecen entremezcladas del Perú a México (ocasionalmente por lo menos una de ellas en California). Opisthonema berlangai, especie nueva, está confinada a la vecindad de las Islas Galápagos.
Resumo:
The Alliance for Coastal Technology (ACT) convened a workshop on the in situ measurement of dissolved inorganic carbon species in natural waters in Honolulu, Hawaii, on February 16, 17, and 18, 2005. The workshop was designed to summarize existing technologies for measuring the abundance and speciation of dissolved inorganic carbon and to make strategic recommendations for future development and application of these technologies to coastal research and management. The workshop was not focused on any specific technology, however, most of the attention of the workshop was on in situ pC02 sensors given their recent development and use on moorings for the measurement of global carbon fluxes. In addition, the problems and limitations arising from the long-term deployment of systems designed for the measurement of pH, total dissolved inorganic carbon (DIC), and total alkalinity (TA) were discussed. Participants included researchers involved in carbon biogeochemistry, industry representatives, and coastal resource managers. The primary questions asked during the workshop were: I. What are the major impediments to transform presently used shipboard pC02 measurement systems for use on cost-eficient moorings? 2. What are the major technical hurdles for the in situ measurement of TA and DIC? 3. What specific information do we need to coordinate efforts for proof of concept' testing of existing and new technologies, inter-calibration of those technologies, better software development, and more precise knowledge quantzjjing the geochemistry of dissolved inoeanic carbon species in order to develop an observing system for dissolved inorganic carbon? Based on the discussion resulting from these three questions, the following statements were made: Statement No. 1 Cost-effective, self-contained technologies for making long-term, accurate measurements of the partial pressure of C02 gas in water already exist and at present are ready for deployment on moorings in coastal observing systems. Statement No. 2 Cost-effective, self-contained systems for the measurement of pH, TA, and DIC are still needed to both fully define the carbonate chemistry of coastal waters and the fluxes of carbon between major biogeochemical compartments (e.g., air-sea, shelf-slope, water column-sediment, etc.). (pdf contains 23 pages)