91 resultados para Fluoroscopy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The registration of pre-operative volumetric datasets to intra- operative two-dimensional images provides an improved way of verifying patient position and medical instrument loca- tion. In applications from orthopedics to neurosurgery, it has a great value in maintaining up-to-date information about changes due to intervention. We propose a mutual information- based registration algorithm to establish the proper align- ment. For optimization purposes, we compare the perfor- mance of the non-gradient Powell method and two slightly di erent versions of a stochastic gradient ascent strategy: one using a sparsely sampled histogramming approach and the other Parzen windowing to carry out probability density approximation. Our main contribution lies in adopting the stochastic ap- proximation scheme successfully applied in 3D-3D registra- tion problems to the 2D-3D scenario, which obviates the need for the generation of full DRRs at each iteration of pose op- timization. This facilitates a considerable savings in compu- tation expense. We also introduce a new probability density estimator for image intensities via sparse histogramming, de- rive gradient estimates for the density measures required by the maximization procedure and introduce the framework for a multiresolution strategy to the problem. Registration results are presented on uoroscopy and CT datasets of a plastic pelvis and a real skull, and on a high-resolution CT- derived simulated dataset of a real skull, a plastic skull, a plastic pelvis and a plastic lumbar spine segment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To design and evaluate a novel computer-assisted, fluoroscopy-based planning and navigation system for minimally invasive ventral spondylodesis of thoracolumbar fractures. MATERIALS AND METHODS: Instruments and an image intensifier are tracked with the SurgiGATE navigation system (Praxim-Medivision). Two fluoroscopic images, one acquired from anterior-posterior (AP) direction and the other from lateral-medial (LM) direction, are used for the complete procedure of planning and navigation. Both of them are calibrated with a custom-made software to recover their projection geometry and to co-register them to a common patient reference coordinate system, which is established by attaching an opto-electronically trackable dynamic reference base (DRB) on the operated vertebra. A bi-planar landmark reconstruction method is used to acquire deep-seated anatomical landmarks such that an intraoperative planning of graft bed can be interactively done. Finally, surgical actions such as the placement of the stabilization devices and the formation of the graft bed using a custom-made chisel are visualized to the surgeon by superimposing virtual instrument representations onto the acquired images. The distance between the instrument tip and each wall of the planned graft bed are calculated on the fly and presented to the surgeon so that the surgeon could formalize the graft bed exactly according to his/her plan. RESULTS: Laboratory studies on phantom and on 27 plastic vertebras demonstrate the high precision of the proposed navigation system. Compared with CT-based measurement, a mean error of 1.0 mm with a standard deviation of 0.1 mm was found. CONCLUSIONS: The proposed computer assisted, fluoroscopy-based planning and navigation system promises to increase the accuracy and reliability of minimally invasive ventral spondylodesis of thoracolumbar fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To carry out long-term follow-up after percutaneous closure of patent foramen ovale (PFO) in patients with cryptogenic stroke. DESIGN: Prospective cohort study. SETTING: Single tertiary care centre. PARTICIPANTS: 525 consecutive patients (mean (SD) age 51 (12) years; 56% male). INTERVENTIONS: Percutaneous PFO closure without intraprocedural echocardiography. MAIN OUTCOME MEASURES: Freedom from recurrent embolic events. RESULTS: A mean (SD) of 1.7 (1.0) clinically apparent embolic events occurred for each patient, and 186 patients (35%) had >1 event. An atrial septal aneurysm was associated with the PFO in 161 patients (31%). All patients were followed up prospectively for up to 11 years. The implantation procedure failed in two patients (0.4%). There were 13 procedural complications (2.5%) without any long-term sequelae. Contrast transoesophageal echocardiography at 6 months showed complete closure in 86% of patients, and a minimal, moderate or large residual shunt in 9%, 3% and 2%, respectively. Patients with small occluders (<30 mm; n = 429) had fewer residual shunts (small 11% vs large 27%; p<0.001). During a mean (SD) follow-up of 2.9 (2.2) years (median 2.3 years; total 1534 patient-years), six ischaemic strokes, nine transient ischaemic attacks (TIAs) and two peripheral emboli occurred. Freedom from recurrent stroke, TIA, or peripheral embolism was 98% at 1 year, 97% at 2 years and 96% at 5 and 10 years, respectively. A residual shunt (hazard ratio = 3.4; 95% CI 1.3 to 9.2) was a risk factor for recurrence. CONCLUSIONS: This study attests to the long-term safety and efficacy of percutaneous PFO closure guided by fluoroscopy only for secondary prevention of paradoxical embolism in a large cohort of consecutive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiation-induced injuries from fluoroscopic procedures in pediatric patients have occurred, and young patients are at greatest risk of many radiation-induced neoplasms. Some fluoroscopists have been injured from their use of fluoroscopy, and they are known to be at risk of radiation-induced neoplasm when radiation is not well-controlled. This article reviews the circumstances that lead to radiation injury and delineates some procedural methods to avoid injury and limit radiation exposure to both the patient and the fluoroscopist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study extends a previous research concerning intervertebral motion registration by means of 2D dynamic fluoroscopy to obtain a more comprehensive 3D description of vertebral kinematics. The problem of estimating the 3D rigid pose of a CT volume of a vertebra from its 2D X-ray fluoroscopy projection is addressed. 2D-3D registration is obtained maximising a measure of similarity between Digitally Reconstructed Radiographs (obtained from the CT volume) and real fluoroscopic projection. X-ray energy correction was performed. To assess the method a calibration model was realised a sheep dry vertebra was rigidly fixed to a frame of reference including metallic markers. Accurate measurement of 3D orientation was obtained via single-camera calibration of the markers and held as true 3D vertebra position; then, vertebra 3D pose was estimated and results compared. Error analysis revealed accuracy of the order of 0.1 degree for the rotation angles of about 1mm for displacements parallel to the fluoroscopic plane, and of order of 10mm for the orthogonal displacement. © 2010 P. Bifulco et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-08