989 resultados para Flow-volume loop
Resumo:
This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.
Resumo:
RESUMO: Introdução: A obstrução da via aérea central (OVAC) refere-se a um processo patológico que conduz a limitação do fluxo de ar ao nível do espaço glótico e subglótico, traqueia e brônquios principais. O seu correcto diagnóstico e tratamento constituem um território de interesse e preocupação para os profissionais de saúde, e requerem um profundo conhecimento da sua etiologia, fisiologia, diagnóstico e opções terapêuticas dado o potencial em originar significativa morbilidade e mortalidade. A avaliação da OVAC abrange múltiplas vertentes, entre as quais se salienta o componente clínico (sinais e sintomas), a repercussão fisiopatológica (função respiratória) e o estudo imagiológico (TC do tórax e broncoscopia). A compilação destes dados associada à etiologia, constituem factores importantes para estabelecer o prognóstico, determinar a necessidade de tratamento ou delinear uma futura intervenção terapêutica. A broncoscopia é o Gold Standard de avaliação desta condição, mas desde há cerca de 40 anos a curva de débito-volume constitui uma ferramenta não invasiva de detecção de OVAC. Apesar deste método ser utilizado até os nossos dias, poucos têm sido os estudos com o objectivo de verificar a sensibilidade e especificidade da curva de débito-volume na detecção de OVAC, bem como averiguar a relação entre as alterações morfológicas e quantitativas da mesma com a localização, o tipo e o grau da obstrução. Material e Métodos: Entre 1 de Novembro de 2009 e 30 de Abril de 2010, os doentes com indicação para a realização de broncoscopia diagnóstica ou terapêutica na Unidade de Técnicas Invasivas Pneumológicas (UTIP) do Centro Hospitalar Lisboa Norte – Hospital Pulido Valente (CHLN – HPV) foram seleccionados de forma consecutiva de acordo com os critérios de inclusão e exclusão. As avaliações (broncoscopia, curva de débito-volume e avaliação da dispneia) realizaram-se com um intervalo de tempo máximo de sete dias. A broncoscopia flexível foi realizada segundo as normas da British Thoracic Society e as curvas de débito-volume segundo as normas da ATS/ERS TaskForce 2005. Para a avaliação da dispneia recorreu-se à escala de dispneia MRC (Medical Research Council). Um painel de peritos realizou a avaliação da morfologia da curva de débito-volume (sugestiva ou não de OVAC) e um elemento independente a verificação dos critérios quantitativos e morfológicos (variáveis intra e extratorácica e fixa) da curva. O estudo foi aprovado pela Comissão de Ética para a Saúde do CHLN e todos os doentes assinaram um consentimento informado de participação. Resultados: Estudaram-se 82 doentes, 36 (44%) dos quais com OVAC. A predominância foi do género masculino, em relação ao feminino. A sensibilidade e especificidade dos critérios quantitativos da curva de débito-volume na detecção de OVAC foi de 91.3% e 88.9% respectivamente. Quando se utilizaram os critérios morfológicos da curva de débito-volume os valores foram de 93.5% e 30.6%. A agregação dos critérios morfológicos e quantitativos permitiu alcançar uma sensibilidade de 95.7% e especificidade de 86.1%. Nesta amostra, o critério quantitativo com maior ocorrência foi o FEF50/FIF50≥1 (83% dos doentes com OVAC). Este mostrou relacionar-se com todas as localizações de obstrução excepto o terço médio da traqueia. Mostrou, ainda, ter uma relação forte e positiva com o grau e tipo de obstrução (intra e extraluminal). O segundo foi o FEV1/PEF≥8, presente em 36% dos casos de OVAC. Relacionou-se com as obstruções no terço inferior da traqueia e brônquio principal direito (BPD). Também apresentou relação forte e positiva com o grau de obstrução e com os tipos de obstrução anteriormente descritos. Quanto à sintomatologia foi possível associar o grau de obstrução com o de dispneia e a presença de estridor com o grau e localização da obstrução na traqueia. Conclusões: Os resultados deste estudo demonstram que os critérios quantitativos da curva de débito-volume têm elevada sensibilidade e especificidade na detecção de OVAC. O critério FEV50/FIF50≥1 tem um bom poder discriminativo na detecção dessa condição, tendo sido relacionado com a localização, o grau e o tipo de obstrução. O critério FEV1/PEF≥8, embora com menor poder discriminativo, também se relaciona com o grau, a localização e o tipo de obstrução. A morfologia da curva tem uma boa sensibilidade mas baixa especificidade na detecção de OVAC, mas a agregação entre os critérios morfológicos e quantitativos aumenta a sensibilidade e especificidade. A dispneia e o estridor foram relacionados com o grau de obstrução e o último com a localização ao nível da traqueia.-------------ABSTRACT: Introduction: Central airway obstruction (CAO) refers to a pathological process that leads to restriction of airflow at the level of the glottis and subglottis, trachea and main bronchi. It’s proper diagnosis and treatment is an area of interest and concern to health professionals, and requires a deep knowledge of its etiology, physiology, diagnosis and treatment options, concerning the potential to cause significant morbidity and mortality. The evaluation of CAO covers multiple aspects: the clinical component (signs and symptoms), the pathophysiological effect (lung function) and the imaging study (bronchoscopy and chest CT). The compilation of this data associated with the etiology, are important for establishing prognosis, determine the need for treatment or outline a future therapeutic intervention. Bronchoscopy is the gold standard for evaluating this condition, but for the last 40 years the flow-volume loop has been used as a noninvasive tool for detecting CAO. Although this method is still in use, only few studies were made in order to verify its sensitivity and specificity in detecting CAO, and investigate the relation between morphological and quantitative changes of the curve to location, type and degree of obstruction. Methods: Between 1st November 2009 and 30th April 2010, patients with indication to perform diagnostic or therapeutic bronchoscopy in Interventional Pulmonology Unit - Hospital Pulido Valente (CHLN - HPV), were selected consecutively according to the inclusion and exclusion criteria. All assessments (bronchoscopy, flow-volume loop and dyspnea) were carried out within a period of seven days. The flexible bronchoscopy was performed according to the standards of the British Thoracic Society and the flow-volume loops in accordance with the standards of the ATS / ERS Taskforce 2005. For the evaluation of dyspnea was used to MRC dyspnea scale (Medical Research Council). A panel of experts evaluated the morphology of flow-volume loop (suggestive or non-suggestive of CAO) and an independent element established the quantitative criteria and morphological (intra and extrathoracic variables and fixed) of the curve. This study was approved by the Ethics Committee for Health CHLN and all the patients signed an informed consent to participate. Results: We’ve studied 82 patients, 36 (44%) of those with CAO. The majority of the patients were males, compared to females. The sensitivity and specificity of the quantitative criteria of the flow-volume curve in detecting CAO was 91.3% and 88.9% respectively. When we used the morphological criteria of flow-volume loop these values were 93.5% and 30.6%. The combination of quantitative and morphological criteria produced values of 95.7% sensitivity and 86.1% specificity. FEF50/FIF50≥1 was the most representative quantitative criterion (83% of patients with CAO) and it was correlated with all sites of obstruction except in the middle third of the trachea. It has shown a strong and positive association with the degree and type of obstruction (intra and extraluminal). The second was the FEV1/PEF ≥ 8, present in 36% of cases of CAO. It could be correlated with the obstruction in the lower third of the trachea and right main bronchus. It also showed a strong positive relation with the degree and types of obstruction described above. Regarding symptoms, we found a link between the degree of obstruction and dyspnea. The presence of stridor was correlated with the location and the degree of obstruction in the trachea. Conclusion: The results of this study demonstrate that the quantitative criteria of the flow-volume loop have a high sensitivity and specificity in detecting CAO. The criterion FEV50/FIF50 ≥ 1 has a good discriminative power to detect this condition and was related to the location, degree and type of obstruction. The criterion FEV1/PEF ≥ 8, although with a weaker discriminative power, also relates to the degree, location and type of obstruction. The morphology of the curve has a good sensitivity but low specificity in detecting CAO although the combination between the morphological and quantitative criteria increases sensitivity and specificity. Dyspnea and stridor were related to the degree of obstruction and the last one with its location in the trachea.
Resumo:
Objective To investigate superior mesenteric artery flow measurement by Doppler ultrasonography as a means of characterizing inflammatory activity in Crohn's disease. Materials and Methods Forty patients were examined and divided into two groups – disease activity and remission – according to their Crohn's disease activity index score. Mean superior mesenteric artery flow volume was calculated for each group and correlated with Crohn's disease activity index score. Results The mean superior mesenteric artery flow volume was significantly greater in the patients with active disease (626 ml/min ± 236 × 376 ml/min ± 190; p = 0.001). As a cut off corresponding to 500 ml/min was utilized, the superior mesenteric artery flow volume demonstrated sensitivity of 83% and specificity of 82% for the diagnosis of Crohn's disease activity. Conclusion The present results suggest that patients with active Crohn's disease have increased superior mesenteric artery flow volume as compared with patients in remission. Superior mesenteric artery flow measurement had a good performance in the assessment of disease activity in this study sample.
Resumo:
We analyzed the flow-volume curves of 50 patients with complaints of snoring and daytime sleepiness in treatment at the Pneumology Unit of the University Hospital of Brasília. The total group was divided into snorers without obstructive sleep apnea (OSA) (N = 19) and snorers with OSA (N = 31); the patients with OSA were subdivided into two groups according to the apnea/hypopnea index (AHI): AHI<20/h (N = 14) and AHI>20/h (N = 17). The control group (N = 10) consisted of nonsmoking subjects without complaints of snoring, daytime sleepiness or pulmonary diseases. The population studied (control and patients) consisted of males of similar age, height and body mass index (BMI); spirometric data were also similar in the four groups. There was no significative difference in the ratio of forced expiratory and inspiratory flows (FEF50%/FIF50%) in any group: control, 0.89; snorers, 1.11; snorers with OSA (AHI<20/h), 1.42, and snorers with OSA (AHI>20/h), 1.64. The FIF at 50% of vital capacity (FIF50%) of snoring patients with or without OSA was lower than the FIF50% of the control group (P<0.05): snorers 4.30 l/s; snorers with OSA (AHI<20/h) 3.69 l/s; snorers with OSA (AHI>20/h) 3.17 l/s and control group 5.48 l/s. The FIF50% of patients with severe OSA (AHI>20/h) was lower than the FIF50% of snorers without OSA (P<0.05): 3.17 l/s and 4.30 l/s, respectively. We conclude that 1) the FEF50%/FIF50% ratio is not useful for predicting OSA, and 2) FIF50% is decreased in snoring patients with and without OSA, suggesting that these patients have increased upper airway resistance (UAR).
Resumo:
BACKGROUND: Prospective assessment of pedicled extrathoracic muscle flaps for the closure of large intrathoracic airway defects after noncircumferential resection in situations where an end-to-end reconstruction seemed risky (defects of > 4-cm length, desmoplastic reactions after previous infection or radiochemotherapy). METHODS: From 1996 to 2001, 13 intrathoracic muscle transpositions (6 latissimus dorsi and 7 serratus anterior muscle flaps) were performed to close defects of the intrathoracic airways after noncircumferential resection for tumor (n = 5), large tracheoesophageal fistula (n = 2), delayed tracheal injury (n = 1) and bronchopleural fistula (n = 5). In 2 patients, the extent of the tracheal defect required reinforcement of the reconstruction by use of a rib segment embedded into the muscle flap followed by temporary tracheal stenting. Patient follow-up was by clinical examination bronchoscopy and biopsy, pulmonary function tests, and dynamic virtual bronchoscopy by computed tomographic (CT) scan during inspiration and expiration. RESULTS: The airway defects ranged from 2 x 1 cm to 8 x 4 cm and involved up to 50% of the airway circumference. They were all successfully closed using muscle flaps with no mortality and all patients were extubated within 24 hours. Bronchoscopy revealed epithelialization of the reconstructions without dehiscence, stenosis, or recurrence of fistulas. The flow-volume loop was preserved in all patients and dynamic virtual bronchoscopy revealed no significant difference in the endoluminal cross surface areas of the airway between inspiration and expiration above (45 +/- 21 mm(2)), at the site (76 +/- 23 mm(2)) and below the reconstruction (65 +/- 40 mm(2)). CONCLUSIONS: Intrathoracic airway defects of up to 50% of the circumference may be repaired using extrathoracic muscle flaps when an end-to-end reconstruction is not feasible.
Resumo:
Respiratory muscle weakness may induce dyspnoea, secretion retention and respiratory failure. Assessing respiratory muscle strength is mandatory in neuromuscular diseases and in case of unexplained dyspnoea. A step by step approach is recommended, starting with simple volitional tests. Using spirometry, respiratory muscle weakness may be suspected on the basis of an abnormal flow-volume loop or a fall of supine vital capacity. When normal, maximal inspiratory and expiratory pressures against a near complete occlusion exclude significant muscle weakness, but low values are more difficult to interpret. Sniff nasal inspiratory pressure is a useful alternative because it is easy and it eliminates the problem of air leaks around the mouthpiece in patients with neuromuscular disorders. The strength available for coughing is easily assessed by measuring peak cough flow. In most cases, these simple non invasive tests are sufficient to confirm or to eliminate significant respiratory muscle weakness and help the timely introduction of ventilatory support or assisted cough techniques. In a minority of patients, a more complete evaluation is necessary using non volitional tests like cervical magnetic stimulation of phrenic nerves.
Resumo:
INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.
Resumo:
BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.
Resumo:
A aquisição do ciclo pressão-volume é de grande importância para diagnóstico de cardiopatias e principalmente para o acompanhamento de intervenções terapêuticas, porém os métodos hoje utilizados são caros e agressivos ao paciente, reduzindo por estes motivos sua aplicação. Este estudo pretende obter, por métodos não-invasivos, o ciclo pressão-volume do ventrículo esquerdo de pacientes humanos. Isto consiste na aquisição dos sinais P(t) e V(t) simultaneamente e a apresentação de um gráfico P(V). Para tanto, após a revisão bibliográfica, decidiu-se utilizar a ecocardiografia com detecção automática de bordos, para obtenção do volume ventricular e a medição da onda de pressão transmitida através da artéria braquial para um manguito inflado com ar, conectado a um transdutor piezo-resistivo em ponte. A aquisição da pressão pelo método não-invasivo é comparada a dados resultantes da aquisição invasiva da pressão arterial por catéter intra-aórtico que é considerado padrãoouro. Os sinais são condicionados e digitalizados em uma placa de aquisição com conversor A/D de 8 bits e micro controlador 80c196. Os dados digitalizados são então enviados serialmente para um computador onde são gerados os gráficos. Obteve-se de cinco pacientes nove aquisições simultâneas da pressão invasiva através de catéter intra-aórtico e do protótipo desenvolvido resultando concordância segundo o método de Bland e Altman (1986) (r=0,989; d + 2s= 6,52; d - 2s =-6,07), comprovando a eficiência do método de aquisição. Obteve-se resultado satisfatório também quanto à operação sistema desenvolvido pois foram realizadas dez aquisições em cinco pacientes, registrando-se gráficos bastante similares aos apresentados na literatura disponível.
Resumo:
Purpose: To investigate whether regional long-term changes in peripapillary retinal flow, measured by scanning laser Doppler flowmetry (SLDF), occur in patients with primary open angle glaucoma (POAG). Methods: 31 healthy volunteers (mean age: 65 8.3 years) and 33 POAG patients (mean age: 71.2 7.6 years) were followed up every 4 months for 16 months. Using SLDF, three images of the superior and inferior optic nerve head were obtained for each subject. A 1010-pixel frame was used to measure blood flow, volume and velocity in the four quadrants of the peripapillary retina. Central 24-2 visual field testing was carried out at each visit. Repeated measures analysis of covariance was used to assess change over time between the normal and POAG groups for the SLDF parameters. Univariate linear regression analysis for mean deviation and glaucoma change probability (GCP) analysis were used to identify visual field progression. Results: Blood volume, flow and velocity measured in the inferior nasal quadrant of the peripapillary retina decreased significantly over time for the POAG group compared to the normal group (p=0.0073, 0.0097, 0.0095 respectively). Overall, 2 glaucoma patients showed a significantly deteriorating MD slope, while 7 patients showed visual field progression with GPA. All of the patients progressing with GPA, showed change in the superior hemifield and, of those, 14% showed change in the inferior hemifield. Conclusion: Glaucoma patients showed a decrease in blood flow, volume and velocity in the inferior nasal peripapillary retina. A regional variation in microvascular retinal capillary blood flow may provide insight into the pathogenesis of glaucomatous optic neuropathy. Keywords: 331 blood supply • 554 retina • 624 visual fields
Resumo:
Flood effectiveness observations imply that two families of processes describe the formation of debris flow volume. One is related to the rainfall?erosion relationship, and can be seen as a gradual process, and one is related to additional geological/geotechnical events, those named hereafter extraordinary events. In order to discuss the hypothesis of coexistence of two modes of volume formation, some methodologies are applied. Firstly, classical approaches consisting in relating volume to catchments characteristics are considered. These approaches raise questions about the quality of the data rather than providing answers concerning the controlling processes. Secondly, we consider statistical approaches (cumulative number of events distribution and cluster analysis) and these suggest the possibility of having two distinct families of processes. However the quantitative evaluation of the threshold differs from the one that could be obtained from the first approach, but they all agree in the sense of the coexistence of two families of events. Thirdly, a conceptual model is built exploring how and why debris flow volume in alpine catchments changes with time. Depending on the initial condition (sediment production), the model shows that large debris flows (i.e. with important volume) are observed in the beginning period, before a steady-state is reached. During this second period debris flow volume such as is observed in the beginning period is not observed again. Integrating the results of the three approaches, two case studies are presented showing: (1) the possibility to observe in a catchment large volumes that will never happen again due to a drastic decrease in the sediment availability, supporting its difference from gradual erosion processes; (2) that following a rejuvenation of the sediment storage (by a rock avalanche) the magnitude?frequency relationship of a torrent can be differentiated into two phases, the beginning one with large and frequent debris flow and a later one with debris flow less intense and frequent, supporting the results of the conceptual model. Although the results obtained cannot identify a clear threshold between the two families of processes, they show that some debris flows can be seen as pulse of sediment differing from that expected from gradual erosion.
Resumo:
BACKGROUND: Exposure to intermittent hypoxia (IH) may enhance cardiac function and protects heart against ischemia-reperfusion (I/R) injury. To elucidate the underlying mechanisms, we developed a cardioprotective IH model that was characterized at hemodynamic, biochemical and molecular levels. METHODS: Mice were exposed to 4 daily IH cycles (each composed of 2-min at 6-8% O2 followed by 3-min reoxygenation for 5 times) for 14 days, with normoxic mice as controls. Mice were then anesthetized and subdivided in various subgroups for analysis of contractility (pressure-volume loop), morphology, biochemistry or resistance to I/R (30-min occlusion of the left anterior descending coronary artery (LAD) followed by reperfusion and measurement of the area at risk and infarct size). In some mice, the phosphatidylinositide 3-kinase (PI3K) inhibitor wortmannin was administered (24 µg/kg ip) 15 min before LAD. RESULTS: We found that IH did not induce myocardial hypertrophy; rather both contractility and cardiac function improved with greater number of capillaries per unit volume and greater expression of VEGF-R2, but not of VEGF. Besides increasing the phosphorylation of protein kinase B (Akt) and the endothelial isoform of NO synthase with respect to control, IH reduced the infarct size and post-LAD proteins carbonylation, index of oxidative damage. Administration of wortmannin reduced the level of Akt phosphorylation and worsened the infarct size. CONCLUSION: We conclude that the PI3K/Akt pathway is crucial for IH-induced cardioprotection and may represent a viable target to reduce myocardial I/R injury.
Resumo:
INTRODUCTION : L’insuffisance cardiaque congestive (ICC) induit remodelage pulmonaire et dysfonction ventriculaire droite (VD) qui contribuent de façon importante à la morbidité/mortalité. Malgré l’efficacité prouvée, l’antagonisme des récepteurs minéralocorticoïdes est sous-utilisé en ICC et ses mécanismes d’actions demeurent incompris. Nous avons évalué si l’Aldostérone contribue au remodelage pulmonaire et à la dysfonction VD en stimulant la prolifération des myofibroblastes (MYFs) pulmonaires. MÉTHODE ET RÉSULTATS : L’étude a été réalisée chez des rats avec infarctus du myocarde (IM) de taille modérée à grande permettant le développement de l’ICC. Deux semaines après l’IM, les rats ont été traités avec 100mg/kg/jour d’Aldactone ou non, pendant trois semaines et comparé à un groupe témoin (N=21;24;8). Comparativement au groupe témoin, les rats IM ont développé une ICC caractérisée par une réduction de la fraction de raccourcissement du VG (53±1%vs.16±2%, moyenne±ESM, P<0.0001), une hypertension pulmonaire (PSVD:27±1vs.40±3mmHg, P<0.01) et une hypertrophie VD (VD/(VG+Septum):24±1%vs.38±3%, P<0.05). L’Aldactone n’a eu aucun effet sur ces paramètres. Les rats IM ont développé un syndrome pulmonaire caractérisé par un abaissement de la courbe respiratoire pression-volume, un remodelage structurel pulmonaire avec doublement du poids poumon sec (P<0.01) et de la fibrose pulmonaire avec augmentation du taux de collagène dans les poumons (P<0.05). L’Aldactone n’a pas restauré la fonction pulmonaire. Enfin, les MYFs pulmonaires isolés n’ont pas proliféré avec l’exposition de 48h aux deux traitements d’Aldostérone (10-7M, 10-6M). CONCLUSION : L’Aldostérone ne contribue pas au remodelage pulmonaire et à la dysfonction VD associés à l’ICC. D’autres mécanismes d’actions sont responsables des effets bénéfiques de l’Aldactone.
Resumo:
A recent nonlinear system by Friston et al. (2000. NeuroImage 12: 466–477) links the changes in BOLD response to changes in neural activity. The system consists of five subsystems, linking: (1) neural activity to flow changes; (2) flow changes to oxygen delivery to tissue; (3) flow changes to changes in blood volume and venous outflow; (4) changes in flow, volume, and oxygen extraction fraction to deoxyhemoglobin changes; and finally (5) volume and deoxyhemoglobin changes to the BOLD response. Friston et al. exploit, in subsystem 2, a model by Buxton and Frank coupling flow changes to changes in oxygen metabolism which assumes tissue oxygen concentration to be close to zero. We describe below a model of the coupling between flow and oxygen delivery which takes into account the modulatory effect of changes in tissue oxygen concentration. The major development has been to extend the original Buxton and Frank model for oxygen transport to a full dynamic capillary model making the model applicable to both transient and steady state conditions. Furthermore our modification enables us to determine the time series of CMRO2 changes under different conditions, including CO2 challenges. We compare the differences in the performance of the “Friston system” using the original model of Buxton and Frank and that of our model. We also compare the data predicted by our model (with appropriate parameters) to data from a series of OIS studies. The qualitative differences in the behaviour of the models are exposed by different experimental simulations and by comparison with the results of OIS data from brief and extended stimulation protocols and from experiments using hypercapnia.
Resumo:
A perfusão total do fígado e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasia e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler tem demonstrado que este é um método viável não-invasivo e de grande auxílio, principalmente na avaliação da hemodinâmica portal. São duas as modalidades de ultra-sonografia Doppler com maior aplicação na rotina para avaliação de fluxo nos vasos abdominais, o Doppler espectral e o Doppler colorido. Na doença hepática crônica, ocorre alteração da complacência hepática devido à fibrose ou à cirrose, as quais acarretam alterações vasculares, levando ao aumento da pressão venosa portal. As principais indicações desse exame são os casos em que há suspeita de hipertensão portal. A hemodinâmica portal é avaliada pela mensuração de sua área, da velocidade média, do volume de fluxo no vaso e do índice de congestão portal. Esta revisão de literatura tem como objetivo descrever os princípios físicos básicos da ultra-sonografia Doppler e sua aplicação na avaliação da hemodinâmica portal nos cães.