998 resultados para Fixed water
Resumo:
Concrete durability may be considered as the ability to maintain serviceability over the design life without significant deterioration, and is generally a direct function of the mixture permeability. Therefore, reducing permeability will improve the potential durability of a given mixture and, in turn, improve the serviceability and longevity of the structure. Given the importance of this property, engineers often look for methods that can decrease permeability. One approach is to add chemical compounds known as integral waterproofing admixtures or permeability-reducing admixtures, which help fill and block capillary pores in the paste. Currently, there are no standard approaches to evaluate the effectiveness of permeability-reducing admixtures or to compare different products in the US. A review of manufacturers’ data sheets shows that a wide range of test methods have been used, and rarely are the same tests used on more than one product. This study investigated the fresh and hardened properties of mixtures containing commercially available hydrophilic and hydrophobic types of permeability-reducing admixtures. The aim was to develop a standard test protocol that would help owners, engineers, and specifiers compare different products and to evaluate their effects on concrete mixtures that may be exposed to hydrostatic or non-hydrostatic pressure. In this experimental program, 11 concrete mixtures were prepared with a fixed water-to-cement ratio and cement content. One plain mixture was prepared as a reference, 5 mixtures were prepared using the recommended dosage of the different permeability-reducing admixtures, and 5 mixtures were prepared using double the recommended dosage. Slump, air content, setting time, compressive and flexural strength, shrinkage, and durability indicating tests including electrical resistivity, rapid chloride penetration, air permeability, permeable voids, and sorptivity tests were conducted at various ages. The data are presented and recommendations for a testing protocol are provided.
Resumo:
The Pt-Ru/C materials of this study were prepared by a microemulsion method with fixed water to surfactant molar ratio and heat treated at low temperatures, to avoid changes in the average particle size, in different atmospheres. All samples were characterized by X-ray diffraction (XRD) and the mean crystallite size was estimated by using Scherrer's equation. Catalysts morphology was characterized by transmission electron microscopy (TEM). Average composition was obtained by energydispersive X-ray analysis (EDX). The general electrochemical behavior was evaluated by cyclic voltammetry in 0.5 M sulfuric acid and the electrocatalytic activity towards the oxidation of methanol was studied in 0.5 M methanol acid solutions by potential sweeps and chronoamperometry. Oxidation of adsorbed CO was used to estimate the electrochemical active area and to infer the surface properties. ©The Electrochemical Society.
Resumo:
This paper introduces a proposal for reservoir volume calculation in rainwater harvesting systems. The proposed method can be used for reservoir volume design in rainwater harvesting systems and is based on three important variables. These variables are water demand, system efficiency and repayment time. Several simulations were carried out in different scenarios considering typical values of both catchment area (for low-income and medium-income households) and water demand, with fixed water and tank costs. Results showed that the integrated analysis of demand, efficiency and repayment time may assist designers to determine a more adequate reservoir volume.
Resumo:
La tesis doctoral “Estudio de hormigón autocompactante con árido reciclado” realizada dentro del programa de doctorado de la Universidad Politécnica de Madrid “Máster en técnicas experimentales avanzadas en la ingeniería civil”, investiga la sustitución de áridos gruesos naturales por reciclados en hormigones autocompactantes, para demostrar la posibilidad de utilización de este tipo de árido en la fabricación de hormigones autocompactantes. En cuanto a la línea experimental adoptada, la primera fase corresponde a la caracterización de los cementos y de los áridos naturales y reciclados. En ella se han obtenido las principales características físicas y mecánicas. Una vez validadas las características de todos los materiales y adoptada una dosificación de hormigón autocompactante, se han elaborado cuatro dosificaciones con cuatro grados de incorporación de árido reciclado cada una, y una dosificación con seis grados de incorporación de árido reciclado. Fabricándose un total de 22 tipos de hormigón diferentes, sin contar todas las amasadas iniciales hasta la consecución de un hormigón autocompactante. Las cinco dosificaciones se han dividido en dos grupos para poder analizar con mayor grado de definición las características de cada uno. El primer grupo es aquel que contienen los hormigones con diferentes relaciones a/c, que incluye a la muestra A (a/c=0.55), muestra D (a/c=0.50) y muestra E (a/c=0.45). Por el contrario, el segundo grupo dispone de una relación fija de a/c=0.45 pero diferentes relaciones a/c efectivas, ya que algunas de las muestras disponen de un contenido de agua que permite contrarrestar la mayor absorción del árido reciclado. Estando en este grupo la muestra E (sin agua adicional), la muestra H (con presaturación de los áridos) y la muestra I (con un aporte de agua junto con el agua de amasado. Una vez fabricados los hormigones, se pasa a la segunda fase del estudio correspondiente a la caracterización del hormigón en estado fresco. En esta fase se han llevado a cabo los ensayos de escurrimiento, escurrimiento con anillo japonés, ensayo embudo en V y embudo V a los 5 minutos. Todos estos ensayos permiten evaluar la autocompactabilidad del hormigón según el anejo 17 de la EHE-08. La tercera fase del estudio se centra en la caracterización de los hormigones en estado endurecido, evaluando las características resistentes del hormigón. Para ello, se han realizado los ensayos de resistencia a compresión, a tracción, módulo de elasticidad y coeficiente de Poisson. En la cuarta y última fase, se han analizado la durabilidad de los hormigones, debido que a pesar de ofrecer una adecuada autocompactabilidad y resistencia mecánica, se debe de obtener un hormigón con una correcta durabilidad. Para tal fin, se ha determinado la resistencia a la penetración de agua bajo presión y carbonatación de las probetas. Este último ensayo se ha realizado teniendo en cuenta las condiciones del denominado método natural, con una exposición al ambiente de 90 días y 365 días. Con todos estos resultados se elaboraron las conclusiones derivadas de la investigación, demostrándose la posibilidad de fabricación de hormigones autocompactantes con árido reciclado (HACR) con sustituciones de hasta un 40%, e incluso dependiendo de la relación a/c con sustituciones del 60% y el 80%. ABSTRACT The doctoral thesis titled Analysis of self-compacting concrete with recycled aggregates, has been developed in accordance with the doctoral program: Master degree in advanced experimental techniques in civil engineering, at UPM. It investigates the possibility of replacing natural coarse aggregates with recycled coarse aggregates, in the field of self-compacting concrete. The aim of this dissertation is to analyze the possibility of using recycled coarse aggregates in the manufacture process of self-compacting concretes. Regarding the experimental part, the first phase refers to mechanical and physical characterization of some materials such as cement, natural aggregates and recycled aggregates. Once the characteristics of all materials have been validated and the mixing proportions have been adopted, four different mixes are elaborated by using four dosage rates of recycled aggregates in each one of the samples. Moreover, an additional sample consisting of six different dosages of recycled aggregates is considered. A total number of 22 concrete specimens have been manufactured, without including all the initial kneading samples used to obtain this type of self-compacting concrete. The aforementioned mixes have been divided in two different groups to be able to analyze with more definition. The first group is the one in which the concrete contains different values of the water - cement ratio. It includes the next samples: A (w/c=0.55), D (w/c=0.50) and E (w/c=0.45). The second group has a fixed water -cement ratio, w/c=0.45, but a different effective water - cement ratio, since some of the samples have a water content that enables to offset the major absorption of the recycled aggregates, being in this group the mixing E (without additional water), the mixing H (with saturated recycled aggregate) and the mixing I (with an additional water content to the existing kneading water). Once the concrete samples have been manufactured, the following section deals with the characterization of the concrete in fresh conditions. To accomplish this, several characterization tests are carried out such as the slump-flow test, test slump flow with Japanese ring, test V-funnel and V-funnel to 5 minutes. These tests are used to assess the self-compacting conditions according to the annex 17 of the EHE-08 The third phase of the study focuses on the mechanical characterization, the assessment of the strength properties of the concrete such as compressive strength, tensile strength, modulus of elasticity and Poisson´s ratio. Within the fourth and last phase, durability of the concrete is evaluated. This fact is motivated by the need to obtain not only good self-compacting and mechanical strength properties, but also adequate durability conditions. To accomplish the aforementioned durability, resistance of the samples under certain conditions such as water penetration pressure and carbonation, has been obtained. The latter test has been carried out taking into account the natural method, with an exhibition period to the environment of 90 days and 365 days. Through the results coming from this research work, it has been possible to obtain the main conclusions. It has been demonstrated the possibility to manufacture self-compacting concrete by using recycled aggregates with replacement rates up to 40% or, depending on the w/c ratio, rates of 60% and 80% might be reached.
Resumo:
"Priestley and carbonated waters, by John J. Riley": p. [1]-17 (1st group)
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
The absorption spectra of DPH at fixed concentration do not change with water content in organic solvents. It exhibits monomer bands, such as those obtained in ethanol. The absorption did not change for solutions up to 54 and 46% of water in ethanol and DMSO, respectively, for [DPH] = 5.0 × 10-6 mol L-1 at 30 °C. However, at the same experimental conditions, a gradual sharp decay of the DPH fluorescence is observed. It is proposed that water molecules below these water concentration limits act as quenchers of the excited states of DPH. Stern-Volmer quenching constants by intensities measurements are 7.4 × 10-2 (water/ethanol) and 2.6 × 10-2 L mol-1 (water/DMSO). DPH lifetime measurements in the absence and presence of water resulted in 7.1 × 10-2 L mol-1 in water/ethanol, which pointed out that the process is a dynamic quenching by water molecules. For experiments using DPH as probe, this process can affect data, leading to misunderstanding interpretation.
Resumo:
Introduction and Purpose: Bimatoprost and the fixed combination of latanoprost with timolol maleate are 2 medications widely used to treat glaucoma and ocular hypertension (OHT). The aim of the study is to compare the efficacy of these 2 drugs in reducing intraocular pressure (IOP) after 8 weeks of treatment in patients with primary open angle glaucoma (POAG) or OHT. Methods: In this randomized, open-label trial, 44 patients with POAG or OHT were allocated to receive either bimatoprost (1 drop QD) or latanoprost/timolol (1 drop QD). Primary outcome was the mean diurnal IOP measurement at the 8th week, calculated as the mean IOP measurements taken at 8:00 AM, 10: 00 AM, and 12: 00 PM Secondary outcomes included the baseline change in IOP measured 3 times a day, after the water-drinking test (performed after the last IOP measurement), and the assessment of side effects of each therapy. Results: The mean IOP levels of latanoprost/timolol (13.83, SD = 2.54) was significantly lower than of bimatoprost (16.16, SD = 3.28; P < 0.0001) at week 8. Also, the change in mean IOP values was significantly higher in the latanoprost/timolol group at 10:00 AM (P = 0.013) and 12:00 PM (P = 0.01), but not at 8: 00 AM (P = ns). During the water-drinking test, there was no signifi cant difference in IOP increase (absolute and percentage) between groups; however, there was a signifi cant decrease in mean heart rate in the latanoprost/timolol group. Finally, no signifi cant changes in blood pressure and lung spirometry were observed in either groups. Conclusions: The fixed combination of latanoprost/timolol was significantly superior to bimatoprost alone in reducing IOP in patients with POAG or OHT. Further studies with large sample sizes should be taken to support the superior efficacy of latanoprost/timolol, as well as to better assess its profile of side effects.
Resumo:
The specific methanogenic activity (SMA) test is an important tool for the monitoring of anaerobic digestion. This paper presents the behavior of the methanogenic archaea of an anaerobic sludge under different conditions of oxygenation in a fixed-bed anaerobic-aerobic reactor treating domestic sewage. The reactor was operated in a continuous manner under different liquid recycle ratios from aerobic to anaerobic zones in order to remove carbon and nitrogen. The application of the SMA test was adapted from several authors and the measurement of the accumulated methane in the reactor was carried out by means of gas chromatography. Methanogenic organisms were not inhibited by the presence of oxygen. In contrast, the values of CH, production rate by sludge exposed to oxygen were greater than those obtained for strictly anaerobic sludge.
Resumo:
The aim of this study was to evaluate how the summer and winter conditions affect the photosynthesis and water relations of well-watered orange trees, considering the diurnal changes in leaf gas exchange, chlorophyll (Chl) fluorescence, and leaf water potential (I) of potted-plants growing in a subtropical climate. The diurnal pattern of photosynthesis in young citrus trees was not significantly affected by the environmental changes when compared the summer and winter seasons. However, citrus plants showed higher photosynthetic performance in summer, when plants fixed 2.9 times more CO(2) during the diurnal period than in the winter season. Curiously, the winter conditions were more favorable to photosynthesis of citrus plants, when considering the air temperature (< 29 A degrees C), leaf-to-air vapor pressure difference (< 2.4 kPa) and photon flux density (maximum values near light saturation) during the diurnal period. Therefore, low night temperature was the main environmental element changing the photosynthetic performance and water relations of well-watered plants during winter. Lower whole-plant hydraulic conductance, lower shoot hydration and lower stomatal conductance were noticed during winter when compared to the summer season. In winter, higher ratio between the apparent electron transport rate and leaf CO(2) assimilation was verified in afternoon, indicating reduction in electron use efficiency by photosynthesis. The high radiation loading in the summer season did not impair the citrus photochemistry, being photoprotective mechanisms active. Such mechanisms were related to increases in the heat dissipation of excessive light energy at the PSII level and to other metabolic processes consuming electrons, which impede the citrus photoinhibition under high light conditions.
Resumo:
We examined resource limitations on growth and carbon allocation in a fast-growing, clonal plantation of Eucalyptus grandis x urophylla in Brazil by characterizing responses to annual rainfall, and response to irrigation and fertililization for 2 years. Productivity measures included gross primary production (GPP), total belowground carbon allocation (TBCA), bole growth, and net ecosystem production (NEP). Replicate plots within a single plantation were established at the midpoint of the rotation (end of year 3), with treatments of no additional fertilization or irrigation, heavy fertilization (to remove any nutrient limitation), irrigation (to remove any water limitation), and irrigation plus fertilization. Rainfall was unusually high in the first year (1769mm) of the experiment, and control plots had high rates of GPP (6.64 kg C m(-2) year(-1)), TBCA (2.14 kg C m(-2) year(-1)), and bole growth (1.81 kg C m(-2) year). Irrigation increased each of these rates by 15-17%. The second year of the experiment had average rainfall (1210 mm), and lower rainfall decreased production in control plots by 46% (GPP), 52% (TBCA), and 40% (bole growth). Fertilization treatments had neglible effects. The response to irrigation was much greater in the drier year, with irrigated plots exceeding the production in control plots by 83% (GPP), 239% (TBCA), and 24% (bole growth). Even though the rate of irrigation ensured no water limitation to tree growth, the high rainfall year showed higher production in irrigated plots for both GPP (38% greater than in drier year) and bole growth (23% greater). Varying humidity and supplies of water led to a range in NEP of 0.8-2.7 kg C m(-2) year. This difference between control and irrigated treatments, combined with differences between drier and wetter years, indicated a strong response of these Eucalyptus trees to both water supply and atmospheric humidity during the dry season. The efficiency of converting light energy into fixed carbon ranged from a low of 0.027 mol C to a high of 0.060 mol C per mol of absorbed photosynthetically active radiation (APAR), and the efficiency of bolewood production ranged from 0.78 to 1.98 g wood per MJ of APAR. Irrigation increased the efficiency of wood production per unit of water used from 2.55 kg wood m(-3) in the rainfed plot to 3.51 kg m(-3) in irrigated plots. Detailed information on the response of C budgets to environmental conditions and resource supplies will be necessary for accurate predictions of plantation yields across years and landscapes. (V) 2007 Elsevier B.V. All rights reserved.
Resumo:
Using a numerical implicit model for root water extraction by a single root in a symmetric radial flow problem, based on the Richards equation and the combined convection-dispersion equation, we investigated some aspects of the response of root water uptake to combined water and osmotic stress. The model implicitly incorporates the effect of simultaneous pressure head and osmotic head on root water uptake, and does not require additional assumptions (additive or multiplicative) to derive the combined effect of water and salt stress. Simulation results showed that relative transpiration equals relative matric flux potential, which is defined as the matric flux potential calculated with an osmotic pressure head-dependent lower bound of integration, divided by the matric flux potential at the onset of limiting hydraulic conditions. In the falling rate phase, the osmotic head near the root surface was shown to increase in time due to decreasing root water extraction rates, causing a more gradual decline of relative transpiration than with water stress alone. Results furthermore show that osmotic stress effects on uptake depend on pressure head or water content, allowing a refinement of the approach in which fixed reduction factors based on the electrical conductivity of the saturated soil solution extract are used. One of the consequences is that osmotic stress is predicted to occur in situations not predicted by the saturation extract analysis approach. It is also shown that this way of combining salinity and water as stressors yields results that are different from a purely multiplicative approach. An analytical steady state solution is presented to calculate the solute content at the root surface, and compared with the outputs of the numerical model. Using the analytical solution, a method has been developed to estimate relative transpiration as a function of system parameters, which are often already used in vadose zone models: potential transpiration rate, root length density, minimum root surface pressure head, and soil theta-h and K-h functions.