980 resultados para Fixed resin bonded partial denture


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A healthy and attractive smile is very valued in today s society. Yet this requires better aesthetic and cosmetic solutions from dental surgeons.The present paper presents a case report of diastema closure using an association of tooth movement induced by orthodontic elastics,dental cosmetics and resin-bonded prosthesis. The female patient L.B.A.J., aged 19 years, visited the Integrated Clinic of Araçatuba DentalSchool UNESP mainly complaining of missing teeth and poor esthetics. After anamnesis, clinical and radiographic examination revealedhypodontia of the maxillary right and left first premolars, abnormal maxillary right lateral incisor shape and diastema between the maxillaryright lateral incisor and canine and between the maxillary left lateral incisor and canine. Planning was done which included indication ofdiastema closure with composite resin restoration and metal-free resin-bonded prosthesis, with a structure made of Vectris (Ivoclar VivadentInc., Amherst, NT, USA). The option for dental cosmetics associated with resin-bonded prosthesis after movement with orthodontic elasticsresulted in an excellent aesthetic outcome of low cost and short treatment duration.Indexing terms: composite resins; diastema; fixed resin bonded partial denture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scleroderma is a connective tissue disorder that can present with orofacial involvement. A 48 year-old patient presented to Cork University Dental Hospital with concerns about the appearance of her upper central incisor teeth, which had become progressively mobile in recent years. A diagnosis of localised scleroderma had been made a number of years previously by her medical practitioner and the patient reported that her scleroderma-associated microstomia had progressed significantly in recent years. Most reports of this condition advocate the use of sectional impression trays and sectional dentures to replace missing teeth. This report describes the use of resin-bonded bridgework (RBB) and discusses the possible advantages of this treatment option over those already presented in the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resin bonded bridgework (RBB) is a technique often overlooked by practitioners despite a large amount of evidence supporting the technique. In Cork University Dental School an evidence-based, standardised approach for the delivery of RBB by undergraduate students has been developed over the past 10 years. The aim of this study was to evaluate the success of this standardised approach on the delivery of RBB by students. 222 bridges were reviewed which had been delivered over a 6 year time period between 2002 and 2007. A success rate of 84.1% was achieved with a mean survival time of 41 months. This study illustrates that predictable and highly successful RBB can be delivered by inexperienced clinicians using an evidence-based, standardised approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interim restorations are frequently used in prosthodontic treatments. Many complex situations require the combination of fixed and removable partial prostheses. An appropriate interim restoration design that accurately implements the treatment plan is necessary to prepare the oral cavity for the prostheses, and to contribute to the preservation and health of remaining natural teeth, bone support, and gingival tissues. This report describes a modified technique for construction of interim restorations with a combination of fixed and removable partial prostheses. The technique consists of the construction of a milled fixed prosthesis and removable partial denture with metallic framework for use during extensive treatment, improving masticatory function and esthetics and preserving the periodontal health of supporting structures. This interim restoration can also serve as a template for the definitive restoration, allowing patient and dentist to evaluate appearance and function and helping to ensure the success of the definitive restoration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ObjectivesThe aim of this study was to evaluate the quality of life and satisfaction of patients wearing implant-supported fixed partial dentures.Materials &methodsA total of 106 patients were selected and submitted to clinical examination and collection of the demographic data for evaluation of the implant-supported fixed dentures conditions. All participants agreed to answer to the Oral Health Impact Profile (OHIP-EDENT) questionnaire and another questionnaire about satisfaction with the implant-supported prostheses. The patients were classified into the following three groups for statistical analysis: patients wearing splinted implant-supported prosthesis (E), patients wearing single implant-supported prosthesis (U), and patients wearing single implant-supported prosthesis associated with splinted prosthesis (E+U). Kruskal-Wallis test was used to compare the answers between the groups, and a logistic regression model was measured to verify the relation between variables of the patients and the questionaries'items.ResultsThere were significant differences among groups (P=0.006) for discomfort during surgery itself of the satisfaction questionnaire. The marital status, groups, and hygiene condition were significant mainly for physical pain item.ConclusionsIt was concluded that the patients presented high level of satisfaction and quality of life for the most of the items evaluated as well as the groups showed similar results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core - MAu; zirconia core - MZi) and the quality of the veneer/core interface (complete bonded - MZi; incomplete bonded - MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Considering the limited qualitative and quantitative bone in the posterior arch, this modality of prosthetic treatment could provide a positive emotional factor reestablished by immovability of the anterior fixed implant-supported segment. Objective: This clinical report demonstrates the possibility of achieving positive results with a removable partial denture connected to an implant-supported fixed prosthesis associated to an extra resilient attachment. Clinical significance: In cases of posterior mandibular and maxilla atrophy added to the patients desire against the bone graft, this kind of prosthetic treatment has an important place as an alternative.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As described in the first paper of this two part series, the expansion of our older population and the concomitant reduction in levels of edentulism will result in an increase in the number of patients presenting in general practice with complex restorative challenges. The application of the concepts of minimal intervention dentistry and minimally invasive operative techniques may offer a powerful armamentarium to the general dentist to provide ethical and conservative treatment to older patients.

Clinical Relevance: When it is unavoidable, operative intervention should be as minimally invasive as practicable in older patients to preserve the longevity of their natural dentition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the impact of tooth replacement on the nutritional status of partially dentate older patients, and, to compare two different tooth replacement strategies; conventional treatment using removable partial dentures and functionally orientated treatment based on the shortened dental arch.

BACKGROUND: Amongst older patients, diet plays a key role in disease prevention, as poor diets have been linked to numerous illnesses. Poor oral health and loss of teeth can have very significant negative effects on dietary intake and nutritional status for elderly patients. There is evidence that good oral health generally, has positive effects on the nutritional intake of older adults.

MATERIALS AND METHODS: A randomised, controlled clinical trial was designed to investigate the impact of tooth replacement on the nutritional status of partially dentate elders. Forty-four patients aged over 65 years completed the trial, with 21 allocated to conventional treatment and 23 allocated to functionally orientated treatment. Nutritional status was accessed at baseline and after treatment using the Mini Nutritional Assessment (MNA) and a range of haematological markers.

RESULTS: At baseline, relationships were observed between the number of occluding tooth contacts and some measures of nutritional status. As the number of contacts increased, MNA scores (R = 0.16), in addition to vitamin B12 (R = 0.21), serum folate (R = 0.32) and total lymphocyte count (R = 0.35), also increased. After treatment intervention, the only measure of nutritional status that showed a statistically significant improvement for both treatment groups was MNA score (p = 0.03). No significant between group differences were observed from analysis of the haematological data.

CONCLUSION: In this study, prosthodontic rehabilitation with both conventional treatment and functionally orientated treatment resulted in an improvement in MNA score. Haematological markers did not illustrate a clear picture of improvement in nutritional status for either treatment group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The non-homogenous aspect of periodontal ligament (PDL) has been examined using finite element analysis (FEA) to better simulate PDL behavior. The aim of this study was to assess, by 2-D FEA, the influence of non-homogenous PDL on the stress distribution when the free-end saddle removable partial denture (RPD) is partially supported by an osseointegrated implant. Material and Methods: Six finite element (FE) models of a partially edentulous mandible were created to represent two types of PDL (non-homogenous and homogenous) and two types of RPD (conventional RPD, supported by tooth and fibromucosa; and modified RPD, supported by tooth and implant [10.00x3.75 mm]). Two additional FE models without RPD were used as control models. The non-homogenous PDL was modeled using beam elements to simulate the crest, horizontal, oblique and apical fibers. The load (50 N) was applied in each cusp simultaneously. Regarding boundary conditions the border of alveolar ridge was fixed along the x axis. The FE software (Ansys 10.0) was used to compute the stress fields, and the von Mises stress criterion (sigma vM) was applied to analyze the results. Results: The peak of sigma vM in non-homogenous PDL was higher than that for the homogenous condition. The benefits of implants were enhanced for the non-homogenous PDL condition, with drastic sigma vM reduction on the posterior half of the alveolar ridge. The implant did not reduce the stress on the support tooth for both PDL conditions. Conclusion: The PDL modeled in the non-homogeneous form increased the benefits of the osseointegrated implant in comparison with the homogeneous condition. Using the non-homogenous PDL, the presence of osseointegrated implant did not reduce the stress on the supporting tooth.