971 resultados para Fixed ICNIP
Resumo:
This paper reports the development of a B2B platform for the personalization of the publicity transmitted during the program intervals. The platform as a whole must ensure that the intervals are filled with ads compatible with the profile, context and expressed interests of the viewers. The platform acts as an electronic marketplace for advertising agencies (content producer companies) and multimedia content providers (content distribution companies). The companies, once registered at the platform, are represented by agents who negotiate automatically the price of the interval timeslots according to the specified price range and adaptation behaviour. The candidate ads for a given viewer interval are selected through a matching mechanism between ad, viewer and the current context (program being watched) profiles. The overall architecture of the platform consists of a multiagent system organized into three layers consisting of: (i) interface agents that interact with companies; (ii) enterprise agents that model the companies, and (iii) delegate agents that negotiate a specific ad or interval. The negotiation follows a variant of the Iterated Contract Net Interaction Protocol (ICNIP) and is based on the price/s offered by the advertising agencies to occupy the viewer’s interval.
Resumo:
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.
Resumo:
Introduction and Purpose: Bimatoprost and the fixed combination of latanoprost with timolol maleate are 2 medications widely used to treat glaucoma and ocular hypertension (OHT). The aim of the study is to compare the efficacy of these 2 drugs in reducing intraocular pressure (IOP) after 8 weeks of treatment in patients with primary open angle glaucoma (POAG) or OHT. Methods: In this randomized, open-label trial, 44 patients with POAG or OHT were allocated to receive either bimatoprost (1 drop QD) or latanoprost/timolol (1 drop QD). Primary outcome was the mean diurnal IOP measurement at the 8th week, calculated as the mean IOP measurements taken at 8:00 AM, 10: 00 AM, and 12: 00 PM Secondary outcomes included the baseline change in IOP measured 3 times a day, after the water-drinking test (performed after the last IOP measurement), and the assessment of side effects of each therapy. Results: The mean IOP levels of latanoprost/timolol (13.83, SD = 2.54) was significantly lower than of bimatoprost (16.16, SD = 3.28; P < 0.0001) at week 8. Also, the change in mean IOP values was significantly higher in the latanoprost/timolol group at 10:00 AM (P = 0.013) and 12:00 PM (P = 0.01), but not at 8: 00 AM (P = ns). During the water-drinking test, there was no signifi cant difference in IOP increase (absolute and percentage) between groups; however, there was a signifi cant decrease in mean heart rate in the latanoprost/timolol group. Finally, no signifi cant changes in blood pressure and lung spirometry were observed in either groups. Conclusions: The fixed combination of latanoprost/timolol was significantly superior to bimatoprost alone in reducing IOP in patients with POAG or OHT. Further studies with large sample sizes should be taken to support the superior efficacy of latanoprost/timolol, as well as to better assess its profile of side effects.
Resumo:
Objective: To determine the changes in the position and form of the temporomandibular joint articular disc in adolescents with Class II division 1 malocclusion and mandibular retrognathism treated with the Herbst appliance (phase I) and fixed orthodontic appliance (phase II). Materials and Methods: Thirty-two consecutive adolescents went through phase I of treatment and 23 completed phase II. The temporomandibular joints were evaluated qualitatively by means of magnetic resonance images at the beginning of treatment (T1), during phase I (T2), at the end of phase I (T3), and at the end of phase II (T4). Results: Significant changes in disc position were not observed with the mouth closed between T1 X T3 (P = .317), T3 X T4 (P = .287), or T1 X T4 (P = .261). At T2, on average, the disc was positioned regressively. With the mouth open, no difference was observed between T1 X T3 (P = .223) or T1 X T4 (P = .082). We did observe a significant difference between T3 X T4 (P < .05). Significant changes in the disc form were found with the mouth closed between T1 X T2 (P < .001) and T2 X T3 (P < .001). Conclusions: At the end of the two-phase treatment, in general terms, the position and form of the initial articular discs were maintained; however, in some temporomandibular joints some seemingly adverse effects were observed at T4. (Angle Orthod. 2010;80:843-852.)
Resumo:
This paper presents a robust voltage control scheme for fixed-speed wind generators using a static synchronous compensator (STATCOM) controller. To enable a linear and robust control framework with structured uncertainty, the overall system is represented by a linear part plus a nonlinear part that covers an operating range of interest required to ensure stability during severe low voltages. The proposed methodology is flexible and readily applicable to larger wind farms of different configurations. The performance of the control strategy is demonstrated on a two area test system. Large disturbance simulations demonstrate that the proposed controller enhances voltage stability as well as transient stability of induction generators during low voltage ride through (LVRT) transients and thus enhances the LVRT capability. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
This paper reports on the design of a new reactor configuration - an upflow fixed-bed combined anaerobic-aerobic reactor - can operate as a single treatment unit for the removal of nitrogen (approximate to 150 mg N/L) and organic matter (approximate to 1300 mg COD/L) from Lysine plant wastewater. L-Lysine, an essential amino acid for animal nutrition, is produced by fermentation from natural raw materials of agricultural origin, thus generating wastewater with high contents of organic matter and nitrogen. The best operational condition of the reactor was obtained with a hydraulic retention time of 35 h (21 h in the anaerobic zone and 14 h in the aerobic zone) and a recycling ratio (R) of 3.5. In this condition, the COD, total Kjeldahl nitrogen (TKN), and total nitrogen (TN) removal efficiencies were 97%, 96%, and 77%, respectively, with average effluent concentrations of 10 +/- 36 mg COD/L, 2 +/- 1 mg NH(4)(+)-N/L, 8 +/- 3 mg Org-N/L, 1 +/- 1 mg NH(2)(-)-N/L, and 26 +/- 23 mg NH(3)(-)-N/L.
Resumo:
This work deals with the problem of minimizing the waste of space that occurs on a rotational placement of a set of irregular two dimensional polygons inside a two dimensional container. This problem is approached with an heuristic based on simulated annealing. Traditional 14 external penalization"" techniques are avoided through the application of the no-fit polygon, that determinates the collision free area for each polygon before its placement. The simulated annealing controls: the rotation applied, the placement and the sequence of placement of the polygons. For each non placed polygon, a limited depth binary search is performed to find a scale factor that when applied to the polygon, would allow it to be fitted in the container. It is proposed a crystallization heuristic, in order to increase the number of accepted solutions. The bottom left and larger first deterministic heuristics were also studied. The proposed process is suited for non convex polygons and containers, the containers can have holes inside. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
This work deals with the problem of minimizing the waste of space that occurs on a rotational placement of a set of irregular bi-dimensional items inside a bi-dimensional container. This problem is approached with a heuristic based on Simulated Annealing (SA) with adaptive neighborhood. The objective function is evaluated in a constructive approach, where the items are placed sequentially. The placement is governed by three different types of parameters: sequence of placement, the rotation angle and the translation. The rotation applied and the translation of the polygon are cyclic continuous parameters, and the sequence of placement defines a combinatorial problem. This way, it is necessary to control cyclic continuous and discrete parameters. The approaches described in the literature deal with only type of parameter (sequence of placement or translation). In the proposed SA algorithm, the sensibility of each continuous parameter is evaluated at each iteration increasing the number of accepted solutions. The sensibility of each parameter is associated to its probability distribution in the definition of the next candidate.
Resumo:
Electromagnetic suspension systems are inherently nonlinear and often face hardware limitation when digitally controlled. The main contributions of this paper are: the design of a nonlinear H(infinity) controller. including dynamic weighting functions, applied to a large gap electromagnetic suspension system and the presentation of a procedure to implement this controller on a fixed-point DSP, through a methodology able to translate a floating-point algorithm into a fixed-point algorithm by using l(infinity) norm minimization due to conversion error. Experimental results are also presented, in which the performance of the nonlinear controller is evaluated specifically in the initial suspension phase. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Rate expression for enzyme poisoning which are consistent with a Michaelis-Menten main reaction are used to analyze the performance of a fixed bed reactor containing immobilized enzyme. When enzyme deactivation results from the irreversible bonding of a product molecule to an existing substrate-enzyme complex, it is shown that minimum enzyme activity can occur in the interior of the bed, well away from the ends. This suggests that bed sectioning techniques may enable direct evaluation of fundamental poisoning mechanisms.
Resumo:
The long performance of an isothermal fixed bed reactor undergoing catalyst poisoning is theoretically analyzed using the dispersion model. First order reaction with dth order deactivation is assumed and the model equations are solved by matched asymptotic expansions for large Peclet number. Simple closed-form solutions, uniformly valid in time, are obtained.
Resumo:
The combination of bupropion and naltrexone is one of the most promising new possibilities for the treatment of obesity in an era of increasing prevalence of this disease and decreasing options for its pharmacological management. Although approved by FDA panel members, it was temporally rejected by the FDA afterwards, who demanded more cardiovascular safety data for its commercialization. This monograph will focus on the physiology involved in its mechanisms of action and results of clinical trials.
Resumo:
Purpose: To evaluate the additive effect of dorzolamide/timolol fixed combination in patients under monotherapy with latanoprost. Patients and Methods: In this prospective, 4-week, randomized, open-label controlled clinical trial, patients with open-angle glaucoma or ocular hypertension, which presented at least 15% intraocular pressure (IOP) reduction after a minimum period of 15 days of monotherapy with latanoprost and whose IOP level was considered above the established target-IOP level were randomized to receive fixed combination of timolol/dorzolamide twice daily in one of eyes. The fellow eye was kept under monotherapy and was included in the control group. A modified diurnal tension curve (mDTC) followed by the water drinking test were performed in the baseline and week 4 visits to evaluate IOP profile between groups. Results: Forty-nine per-protocol patients were analyzed. After latanoprost monotherapy run-in period, IOP levels were significantly reduced (P<0.001) in both control and study groups to 15.34 +/- 2.96 mm Hg and 15.24 +/- 2.84 mm Hg (30.8% and 32.2% IOP reduction, respectively; P=0.552). At week 4, mean baseline diurnal IOP levels were 15.60 +/- 3.09 and 14.44 +/- 3.03 (7.4% difference; P=0.01). Mean baseline IOP modified diurnal tension curve peak after latanoprost run-in period were 17.47 +/- 3.68 mm Hg and 17.02 +/- 3.35 mm Hg (control and study eyes, respectively; P=0.530). At week 4 visit, mean water-drinking test peaks were significantly reduced in the study eye group in comparison with the control group: 19.02 +/- 3.81 mm Hg and 20.39 +/- 4.19 mm Hg, respectively (6.7% reduction; P=0.039). Conclusions: In our sample, dorzolamide 2%/timolol 0.5% fixed combination as add-on therapy in patients with open-angle glaucoma or ocular hypertension under monotherapy with latanoprost with IOP already in mid-teens levels may further enhance pressure reduction.
Resumo:
Purpose: To compare the efficacy and tolerability of the fixed combination of timolol maleate 0.5%/brimonidine tartrate 0.2% versus fixed combination of timolol maleate 0.5%/dorzolamide 2% in patients with elevated intraocular pressure (IOP) over 8 weeks. Patients and Methods: This 8-week, multicentric. interventional, randomized, open-label, parallel group study was conducted Lit 4 centers in Brazil and 1 center in Argentina. Patients with open-angle glaucoma or ocular hypertension were randomized to receive bilaterally fixed combination of brimonidine/timolol maleate 0.5% or fixed combination of dorzolamide 2%/timolol 0.5% twice daily at 8:00 AM and 8:00 PM. A modified diurnal tension curve (8:00 AM 10:30 AM, 02:00 PM, and 4:00 PM) followed by the water drinking test (WDT), which estimates IOP peak of diurnal tension curve, were performed in the baseline and week-8 visits. Adverse events data were recorded at each visit. Results: A total of 210 patients were randomized (brimonidine/timolol, n = 111; dorzolamide/timolol, n = 99). Mean baseline IOP was 23.43 +/- 3.22 mm Hg and 23.43 +/- 4.06 mm Hg in the patients treated with brimonidine/timolol and dorzolamide/timolol, respectively (P = 0.993). Mean diurnal IOP reduction after 8 weeks were 7.02 +/- 3.06 mm Hg and 6.91 +/- 3.67 mm Hg. respectively (P = 0.811). The adjusted difference between groups (analysis of covariance) Lit week 8 was not statistically significant (P = 0.847). Mean baseline WDT peak was 27.79 +/- 4.29 mm Hg in the brimonidine/timolol group and 27.68 +/- 5.46 mm Hg in the dorzolamide/timolol group. After 8 weeks of treatment, mean WDT peaks were 20.94 +/- 3.76 mm Hg (P < 0.001) and 20.98 +/- 4.19 (P < 0.001), respectively. The adjusted difference between groups (analysis of covariance) was not statistically significant (P = 0.469). No statistical difference in terms of adverse events was Found between groups. Conclusions: Both fixed combinations were capable of significantly reducing the mean diurnal IOP, mean diurnal peak, and mean WDT peak after 8 weeks of treatment. Also, both fixed combinations are well tolerated with few side effects.