969 resultados para Fine Particle Processing
A Study on Health Effects of Fine Particle Concentrations in Tampere area during 2.5 Years Follow-up
Resumo:
This work reports on the luminescence spectroscopy sensitivity in the determination of the phase purity in gadolinium compounds using Eu3+ as a probe. Cubic Gd2O3 and hexagonal Gd2O2S doped with Eu3+ spherical fine particles were obtained from doped gadolinium basic carbonates with morphological control and were also characterized by IR and XRD. Doped samples present Eu3+ characteristic transitions, with specific energy positions related to each phase. Emission and excitation spectra patterns were established for oxide and oxysulfide compounds, then oxysulfate and oxide impurities generated during oxysulfide preparation were monitored. From emission spectra some experimental intensity parameters were also calculated. All spectroscopic results reflect the presence or not of impurities in all compounds. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Acknowledgements Gokul Gopalan (a Senior Global Medical Director [Respiratory], at Teva Pharmaceuticals, Frazer, PA, US, at the time of this study), assisted with study design. Funding Funds to acquire the dataset from the Pharmo Institute for Drug Outcomes Research (Utrecht, the Netherlands) were provided by RiRL. The study received institutional support from Teva Pharmaceuticals Europe B.V. Gokul Gopalan, a Senior Global Medical Director (Respiratory), at Teva Pharmaceuticals, Frazer, PA, US, at the time of this study, assisted with study design, but neither Teva Pharmaceuticals Europe B.V. nor Teva Pharmaceuticals, Frazer, PA, US, contributed, either in part or in whole, to the collection, analysis, or interpretation of study data, manuscript writing, or the decision to submit the manuscript for publication. Erratum The original version of this article unfortunately contained errors that have since been corrected. The word “pharmo” has been fully capitalised to “PHARMO” throughout the article. The reference to Table 2 in the first and second sentence under the Outcomes heading has been replaced with Fig. 3. Under the Abbreviations heading ‘extrafine-particle’ was repeated, this has been corrected to ‘EF-HFA-BDP [Qvar®]: extrafine-particle hydrofluoroalkane beclomethasone dipropionate’. The competing interests of Nicolas Roche and Theresa Guibert have been amended. Academic affiliations for Dirkje S. Postma (2), Richard J. Martin (3), Ron M.C. Herrings (4), Jetty Overbeek (4), and Nicolas Roche (7) have been corrected. Figure 3 in the online and pdf version did not match, this been amended
Resumo:
Stirred Mills are becoming increasingly used for fine and ultra-fine grinding. This technology is still poorly understood when used in the mineral processing context. This makes process optimisation of such devices problematic. 3D DEM simulations of the flow of grinding media in pilot scale tower mills and pin mills are carried out in order to investigate the relative performance of these stirred mills. In the first part of this paper, media flow patterns and energy absorption rates and distributions were analysed to provide a good understanding of the media flow and the collisional environment in these mills. In this second part we analyse steady state coherent flow structures, liner stress and wear by impact and abrasion. We also examine mixing and transport efficiency. Together these provide a comprehensive understanding of all the key processes operating in these mills and a clear understanding of the relative performance issues. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Base metal resources are becoming more fine-grained and refractory and minerals separation processes require these ores to be milled to increasingly finer sizes. To cope with very fine grinding to below a P-80 of approximately 15 mum stirred milling technology has been adopted from other industries Neither this technology, nor the basic concepts of fine grinding, are well understood by the minerals processing industry. Laboratory studies were therefore carried out in order to investigate fine milling using different types of stirred mills. The variables analysed were stirrer speed, grinding media type and size, slurry solids content as well as the feed and product size. The results of the testwork have shown that all of these variables affect the grinding efficiency. The ratio of media size to material size was found to be of particular significance. The results were also analysed using the stress intensity approach and the optimum stress intensity ranges for the most efficient grinding were determined. Application of the results for process optimisation in the industrial size units is also discussed in this paper. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
A more efficient classifying cyclone (CC) for fine particle classification has been developed in recent years at the JKMRC. The novel CC, known as the JKCC, has modified profiles of the cyclone body, vortex finder, and spigot when compared to conventional hydrocyclones. The novel design increases the centrifugal force inside the cyclone and mitigates the short circuiting flow that exists in all current cyclones. It also decreases the probability of particle contamination in the place near the cyclone spigot. Consequently the cyclone efficiency is improved while the unit maintains a simple structure. An international patent has been granted for this novel cyclone design. In the first development stage-a feasibility study-a 100 mm JKCC was tested and compared with two 100 min commercial units. Very encouraging results were achieved, indicating good potential for the novel design. In the second development stage-a scale-up stage-the JKCC was scaled up to 200 mm in diameter, and its geometry was optimized through numerous tests. The performance of the JKCC was compared with a 150 nun commercial unit and exhibited sharper separation, finer separation size, and lower flow ratios. The JKCC is now being scaled up into a fill-size (480 mm) hydrocyclone in the third development stage-an industrial study. The 480 mm diameter unit will be tested in an Australian coal preparation plant, and directly compared with a commercial CC operating under the same conditions. Classifying cyclone performance for fine coal could be further improved if the unit is installed in an inclined position. The study using the 200 mm JKCC has revealed that sharpness of separation improved and the flow ratio to underflow was decreased by 43% as the cyclone inclination was varied from the vertical position (0degrees) to the horizontal position (90degrees). The separation size was not affected, although the feed rate was slightly decreased. To ensure self-emptying upon shutdown, it is recommended that the JKCC be installed at an inclination of 75-80degrees. At this angle the cyclone performance is very similar to that at a horizontal position. Similar findings have been derived from the testing of a conventional hydrocyclone. This may be of benefit to operations that require improved performance from their classifying cyclones in terms of sharpness of separation and flow ratio, while tolerating slightly reduced feed rate.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of this study was to evaluate the effect of corn texture and the particle size on broiler performance, carcass yield, nutrient digestibility, and digestive organ morphometrics. In Experiment I, 720 male Cobb chicks were distributed in a completely randomized experimental design with a 2 x 3 factorial arrangement, consisting two corn textures (dented and hard) and three corn particle sizes, was applied, with four replicates of 30 birds each. Corn particle size was classified according to geometric mean diameter (GMD) as fine - 0.46 mm; medium - 0.73 mm, and coarse - 0.87 mm. In Experiment II, 120 broiler chicks were used to evaluate corn digestibility during the periods of 16 to 22 days and 35 to 41 days of age, using the method of total excreta collection. In Experiment I, corn particle size influenced body weight, average weight gain, feed intake and feed conversion ratio of 21-day-old birds. Corn texture and particle size did not affect the performance of 42-day-old broilers or carcass traits. In Experiment II, there was no influence of corn texture and particle size on digestive organ weights. Dented corn increased nitrogen excretion in the first trial, and hard corn improved dry matter digestibility in the second metabolic trial. Corn with fine particle size promotes better performance of broilers at 21 days of age. Hard corn results in higher dry matter digestibility and lower nitrogen excretion, and consequently higher production factor in 42-day-old broilers.
Resumo:
Sulfate aerosol plays an important but uncertain role in cloud formation and radiative forcing of the climate, and is also important for acid deposition and human health. The oxidation of SO2 to sulfate is a key reaction in determining the impact of sulfate in the environment through its effect on aerosol size distribution and composition. This thesis presents a laboratory investigation of sulfur isotope fractionation during SO2 oxidation by the most important gas-phase and heterogeneous pathways occurring in the atmosphere. The fractionation factors are then used to examine the role of sulfate formation in cloud processing of aerosol particles during the HCCT campaign in Thuringia, central Germany. The fractionation factor for the oxidation of SO2 by ·OH radicals was measured by reacting SO2 gas, with a known initial isotopic composition, with ·OH radicals generated from the photolysis of water at -25, 0, 19 and 40°C (Chapter 2). The product sulfate and the residual SO2 were collected as BaSO4 and the sulfur isotopic compositions measured with the Cameca NanoSIMS 50. The measured fractionation factor for 34S/32S during gas phase oxidation is αOH = (1.0089 ± 0.0007) − ((4 ± 5) × 10−5 )T (°C). Fractionation during oxidation by major aqueous pathways was measured by bubbling the SO2 gas through a solution of H2 O2
Resumo:
Background Airborne particles entering the respiratory tract may interact with the apical plasma membrane (APM) of epithelial cells and enter them. Differences in the entering mechanisms of fine (between 0.1 μm and 2.5 μm) and ultrafine ( ≤ 0.1 μm) particles may be associated with different effects on the APM. Therefore, we studied particle-induced changes in APM surface area in relation to applied and intracellular particle size, surface and number. Methods Human pulmonary epithelial cells (A549 cell line) were incubated with various concentrations of different sized fluorescent polystyrene spheres without surface charge (∅ fine – 1.062 μm, ultrafine – 0.041 μm) by submersed exposure for 24 h. APM surface area of A549 cells was estimated by design-based stereology and transmission electron microscopy. Intracellular particles were visualized and quantified by confocal laser scanning microscopy. Results Particle exposure induced an increase in APM surface area compared to negative control (p < 0.01) at the same surface area concentration of fine and ultrafine particles a finding not observed at low particle concentrations. Ultrafine particle entering was less pronounced than fine particle entering into epithelial cells, however, at the same particle surface area dose, the number of intracellular ultrafine particles was higher than that of fine particles. The number of intracellular particles showed a stronger increase for fine than for ultrafine particles at rising particle concentrations. Conclusion This study demonstrates a particle-induced enlargement of the APM surface area of a pulmonary epithelial cell line, depending on particle surface area dose. Particle uptake by epithelial cells does not seem to be responsible for this effect. We propose that direct interactions between particle surface area and cell membrane cause the enlargement of the APM.
Resumo:
Continuous condensation particle (CP) observations were conducted from 1984 through 2009 at Neumayer Station under stringent contamination control. During this period, the CP concentration (median 258 1/cm**3) showed no significant long term trend but exhibited a pronounced seasonality characterized by a stepwise increase starting in September and reaching its annual maximum of around 10**3/cm**3 in March. Minimum values below 10**2/cm**3 were observed during June/July. Dedicated time series analyses in the time and frequency domain revealed no significant correlations between inter-annual CP concentration variations and atmospheric circulation indices like Southern Annular Mode (SAM) or Southern Ocean Index (SOI). The impact of the Pinatubo volcanic eruption and strong El Niño events did not affect CP concentrations. From thermodenuder experiments we deduced that the portion of volatile (at 125 °C) and semi-volatile (at 250 °C) particles which could be both associated with biogenic sulfur aerosol, was maximum during austral summer, while during winter non-volatile sea salt particles dominated. During September through April we could frequently observe enhanced concentrations of ultrafine particles within the nucleation mode (between 3 nm and 7 nm particle diameter), preferentially in the afternoon.