855 resultados para Filtration technique
Resumo:
Campylobacter was isolated in 178 out of 622 stool samples (200 porcine, 220 bovine, and 202 canine). From these 178 samples, the microorganism was identified in 64 samples (36%) isolated only in Butzler selective medium (BSM), 34 samples (19%) using filtration technique (FT), and in 80 samples (45%) using both BSM and FT. Comparison of the proportion of positivity using both techniques showed a significant value (c2 = 9,184; p > 0.001); BSM (36%) being more efficient than FT (19%). The use of both techniques yielded the highest isolation positivity (45%).
Resumo:
The aim of this thesis was to identify the best grease removal technique with the application of low power of UV light to TiO2 coated grease filters. The treatment with various power series of ozone generating and ozone free lamps to normal grease filters and TiO2 coated grease filters were examined and the obtained results are compared to each other in this paper. The effect of ozone reaction was observed and compared with the effect of TiO2. The experiments were solely based on the photo oxidation and photo catalytic oxidation reactions. TiO2 is a green catalyst used in the photocatalytic reaction. Sunflower oil was used for grease production and tetracholoroethylene as a solvent. Grease samples were collected from the ventilation duct connected to the cooking hood system. Sample extraction was done in ultrasonic bath with the principle of sonication. The sample analysis was done by FTIR machine. The result determining the concentration of grease was the quantification of saturated C-H bonds in the chosen peak group of the spectrum. A very low power of UVC light functions perfectly with the Titanium dioxide. The experimental results have shown the combined treatment of titanium dioxide and UV light is an effective method in grease removal process. The photocatalytic reaction with titanium dioxide is better than photo oxidation reaction with ozone treatment. Photocatalytic reaction is environmentally friendly, energy efficient and economical.
Resumo:
Do total de 622 amostras de fezes, sendo 200 de suínos, 220 de bezerros e 202 de cães, Campylobacter foi isolado em 178 amostras. Destas, o agente foi identificado em 64 (36%) amostras, isoladas somente em meio seletivo de Butzler (MSB); em 34 (19%) o microorganismo foi isolado a partir da técnica de filtração (TF) e em 80 (45%), através de ambos os procedimentos (MSB+TF). A comparação entre as proporções de positividade, pelas diferentes técnicas, revelou significância (c2 = 9.184; p > 0,001) sendo a MSB (36%) a mais eficiente comparada com a TF (19%) O uso associado de ambos os procedimentos proporcionou a positividade mais elevada de isolamento com 45%.
Resumo:
A baciloscopia é o principal método diagnóstico da tuberculose (TB) em razão do seu baixo custo, rapidez e facilidade de execução. Porém sua sensibilidade é baixa, principalmente nas formas paucibacilares da doença. Nesse sentido, novas metodologias que resultem no aumento da sensibilidade da baciloscopia tornam-se absolutamente necessárias. Neste estudo, nos propusemos a aprimorar e padronizar o sistema de filtração BacFil e avaliar sua performance e acurácia em amostras paucibacilares (lavado broncoalveolar). Para alcançar esses objetivos desenvolvemos o estudo em duas fases. Na primeira fase, foram realizados ensaios para definir: 1) utilização de membranas brancas para visualização de BAAR corados por Auramina-O; 2) aumento do volume de NALC, utilização de pérolas de vidro no processo de digestão das amostras e mudança no sistema do suporte do pré-filtro; 3) meios de fixação da membrana de filtração na lâmina de microscopia; 4) limite de detecção da técnica; 5) aumento do volume de NaOCl e a influência desse aumento na visualização de BAAR na membrana. Verificou-se que: a membrana de policarbonato branca tem a mesma eficiência da membrana de policarbonato preta na visualização de BAAR fluorescentes; o método modificado utilizando maior concentração de NALC, pérolas de vidro e sistema de pré-filtro baseado em orifícios obteve 98% de passagem das amostras pelo sistema; a melhor forma de fixação da membrana na lâmina foi obtida por intermédio da utilização de fita dupla face; o limite de detecção da técnica de filtração utilizando o sistema BacFil versão 6.0 foi de 2 a 9 BAAR por mililitro de suspensão bacteriana com D.O de 0,250 ± 0,01 a 625nm; o aumento da concentração de NaOCl para 10% ajuda na passagem de um maior volume de amostra pelo sistema, porém ocasiona a diminuição da quantidade BAAR na membrana de filtração após o período necessário para todo o processo. Na segunda fase foi avaliado acurácia da técnica padronizada em 101 amostras de lavado broncoalveolar (LBA) de pacientes com suspeita de TB provenientes do Hospital Universitário Cassiano Antônio de Moraes. Observou-se que a sensibilidade da técnica de filtração (BacFil versão 6.0) foi de 76% e especificidade de 95%. A sensibilidade obtida foi significativamente maior do que a observada na baciloscopia após centrifugação que foi de 59% (p = 0,001). No entanto, constatou-se uma diminuição de especificidade na técnica de filtração (95%) em relação a técnica de 8 centrifugação (99%). Concluímos que as modificações realizadas nos sistema de filtração permitiu sanar os problemas técnicos apresentados nas versões anteriores e aumentar a sensibilidade da baciloscopia de amostras paucibacilares (lavado broncoalveolar) para o diagnóstico da TB pulmonar.
Resumo:
Mice experimentally infected with Schistosoma mansoni were injected with sodium thiopental or sodium antimonyl gluconate (Triostib R), or submitted to halothane inhalation, with or without a previous injection of thiopental. Data obtained showed that halothane and thiopental induce worm shift to the liver (99 and 76%, respectively). Sodium gluconate and antimonium (Triostib R) shifted 52% of worms towards the liver. These results seem to indicate that the use of antimonium would be unnecessary, when surgical removal of schistosomules is carried out through the extracorporeal filtration technique, in patients with portal hypertension.
Resumo:
The subcellular localization of a calmodulin-stimulated calcium (Ca2+)-ATPase activity from maize roots (Zea mays L., cv LG 11) was studied. For this purpose, an efficient procedure was developed to prepare sealed plasma membrane vesicles allowing the measurement of proton and Ca2+ transport activities. Two-day-old root membranes were fractionated by sucrose and dextran density gradient centrifugation. Marker enzymes were used to study the distribution of the different membranes in the gradients and a filtration technique was developed to measure Ca-45(2+) transport in sealed vesicles. Most of the ATP-dependent Ca2+ transport activity was associated with the ER. However, a small part of this activity was associated with the tonoplast (corresponding to the activity of the H+/Ca2+ antiport) and the plasma membrane. When the Ca2+ transport was measured in the presence of exogenous calmodulin (1 muM), a 3-5-fold increase of uptake was measured. The calmodulin-stimulated activity was associated with the tonoplast vesicles only. This activity was insensitive to monensin, a proton ionophore, ruling out a direct effect of calmodulin on the H+/Ca2+ antiport. In conclusion, four different Ca2+ transporters are present in young maize root cells. A Ca2+/H+ antiport system is present on the tonoplast, whereas, the plasma membrane and the ER possess each a calmodulinin-sensitive Ca2+-ATPase. Finally, a calmodulin-stimulated Ca2+-ATPase is associated with the tonoplast.
Resumo:
Some Ecological Factors Affecting the Input and Population Levels of Total and Faecal Coliforms and Salmonella in Twelve Mile Creek, Lake Ontario and Sewage Waters Near St. Catharines, Ontario. Supervisor: Dr. M. Helder. The present study was undertaken to investigate the role of some ecological factors on sewage-Dorne bacteria in waters near St. Catharines, Ontario. Total and faecal coliform levels and the presence of Salmonella were monitored for a period of a year along with determination of temperature, pH, dissolved oxygen, total dissolved solids, nitrate N, total phosphate P and ammonium N. Bacteriological tests for coliform analysis were done according to APHA Standard Methods by the membrane filtration technique. The grab sampling technique was employed for all sampling. Four sample sites were chosen in the Port Dalhousie beach area to determine what bacteriological or physical relationship the sites had to each other. The sample sites chosen were the sewage inflow to and the effluent from the St. Catharines (Port Dalhousie) Pollution Control Plant, Twelve Mile Creek below the sewage outfall and Lake Ontario at the Lakeside Park beach. The sewage outfall was located in Twelve Mile Creek, approximately 80 meters from the creek junction with the beach and piers on Lake Ontario. Twelve Mile Creek normally carried a large volume of water from the WeIland Canal which was diverted through the DeCew Generating Station located on the Niagara Escarpment. An additional sample site, which was thought to be free of industrial wastes, was chosen at Twenty Mile Creek, also in the Niagara Region of Ontarioo 3 There were marked variations in bacterial numbers at each site and between each site, but trends to lower_numbers were noted from the sewage inflow to Lake Ontario. Better correlations were noted between total and faecal coliform population levels and total phosphate P and ammonium N in Twenty Mile Creek. Other correlations were observed for other sample stations, however, these results also appeared to be random in nature. Salmonella isolations occurred more frequently during the winter and spring months when water temperatures were minimal at all sample stations except the sewage inflow. The frequency of Salmonella isolations appeared to be related to increased levels of total and faecal coli forms in the sewage effluent. However, no clear relationships were established in the other sample stations. Due to the presence of Salmonella and high levels of total and faecal coliform indicator organisms, the sanitary quality of Lake Ontario and Twelve Mile Creek at the sample sites seemed to be impaired over the major portion of the study period.
Resumo:
Heterokaryons were obtained by hyphal anastomosis in Trichoderma pseudokoningii using strains with morphologic and double auxotrophic genetic markers. Stable haploid and unstable hyperhaploid recombinants were detected in monosporic colonies derived from heterokaryons and selected in appropriate media or by an enrichment filtration technique. Diploids were not observed and the recombinant frequencies were higher than those found in fungi with a typical parasexual cycle. The mechanism of recombinant emergence may involve a transient diploid formation followed by chromosomal losses at the hyphal stages, resulting in haploid and hyperhaploid recombinants. The possibility of intrachromosomal rearrangement with the involvement of cytoplasmatic DNA as a heterokaryotic transformation system cannot be excluded.
Resumo:
Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Resumo:
The dataset provides detailed information on the study that was conducted in Lahore's 7 major towns. The sample was taken from 472 tubewells and analyzed for major cations and anions using APHA 2012 techniques as explained herein. Besides, E.coli determination was done to check for microbial contamination. The data includes results from PHREEQC modeling of As(III)/ As(V) species and saturation indices as well as Aquachem's computed hydrochemical water facies. The WHO (2011) and EPA standards included in Aquachem identified the parameters that where in violation. Bicarbonates dominated the groundwater types with 50.21% of the samples exceeding the EPA maximum permissible limit of 250 mg/L in drinking water. Similarly, 30.51% of the samples had TDS values greater than 500 mg/L while 85.38 % of the samples exceed 10 µg/L threshold limit value of arsenic. Also, instances of high magnesium hazard values were observed which requires constant assessment if the groundwater is used for irrigation. Higher than 50% MH values are detrimental to crops which may reduce the expected yields. The membrane filtration technique using m-Endo Agar indicated that 3.59% samples had TNC (too numerous to count) values for E.coli while 5.06% showed values higher than 0 cfu/ 100 ml acceptable value in drinking water. Any traces of E-coli in a groundwater sample indicate recent fecal contamination. Such outcomes signify presence of enteric pathogens. If the groundwater is not properly dosed with disinfectants it may cause harm to human health. It is concluded that more studies are needed and proper groundwater management implement to safeguard the lives of communities that depend solely on groundwater in the city.
Resumo:
A growing demand for efficient air quality management calls for the development of technologies capable of meeting the stringent requirements now being applied in areas of chemical, biological and medical activities. Currently, filtration is the most effective process available for removal of fine particles from carrier gases. Purification of gaseous pollutants is associated with adsorption, absorption and incineration. In this paper we discuss a new technique for highly efficient simultaneous purification of gaseous and particulate pollutants from carrier gases, and investigate the utilization of Nuclear Magnetic Resonance (NMR) imaging for the study of the dynamic processes associated with gas-liquid flow in porous media. Our technique involves the passage of contaminated carrier gases through a porous medium submerged into a liquid, leading to the formation of narrow and tortuous pathways through the medium. The wet walls of these pathways result in outstanding purification of gaseous, liquid and solid alien additives. NMR imaging was successfully used to map the gas pathways inside the porous medium submerged into the liquid layer. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Purpose: To study the filtering site using ultrasound biomicroscopy. (UBM) after posterior deep sclerectomy with Ex-PRESS? X-50 implant in patients undergoing filtering surgery.¦Methods: Twenty-six patients that participated in this prospective, non comparative study underwent a posterior deep sclerectomy and an Ex- PRESS? X-50 tube implantation. Clinical outcome factors recorded include: intraocular pressure, number of antiglaucoma medications, best corrected visual acuity (BCVA), frequency and types of complications. Six months postoperatively, an ultrasound biomicroscopy examination was performed.¦Results: Mean follow up was 12.0±3.4 months. Mean IOP decreased from 21 ±5.7 mmHg to 12.4±3 mmHg. At last follow-up examination, 65% of eyes had a complete success and 30% a qualified success. The mean number of antiglaucoma medications decreased from 2.5±1.2 preoperatively to 0.7±1 at the last follow-up postoperatively. BCVA was not changed. 27 complications were observed. On the UBM images, the mean intrascleral space volume was 0.25±0.27 mm3 and no relationship was found between volume and intraocular pressure reduction. We noted in 5/26 (19%) eyes a suprachoroïdal hypoechoic. Low-reflective blebs (L-type) were the most common: 15/26 (58%). No correlation between UBM findings and surgical success was evident.¦Conclusions: Deep sclerectomy with Ex-PRESS? X-50 tube implantation seems an efficient glaucoma surgery. It allows satisfactory IOP reduction with a low number of post operative complications. The advantages of deep sclerectomy with collagen implant are maintained with this modified technique. In both, the same reflective types of filtering blebs are present (high, low, encapsulated and flat). The UBM underlines the three mechanisms of aqueous humor resorption previously identified but no correlation with surgical success can be proved.¦-¦Ce travail de thèse est une analyse par ultrasonographic biomicroscopique (UBM) du site de filtration après sclérectomie profonde postérieure modifiée avec implantation d'un tube Ex- PRESS? X-50.¦Vingt six patients atteints d'un glaucome à angle ouvert, ont participé à cette étude prospective et non-comparative. Le critère d'inclusion est un glaucome à angle ouvert non contrôlé malgré un traitement topique maximal.¦Différents types de chirurgie filtrante sont effectués dans la chirurgie du glaucome dont la trabéculectomie et la sclérectomie profonde.¦L'intervention chirurgicale pratiquée dans cette étude consiste en l'implantation d'un tube Ex-PRESS? X-50 de format défini (3 mm de longueur et 50 μπι de diamètre interne) dans la chambre antérieure,au niveau du trabeculum, sous un volet scléral, ce qui permet le drainage de l'humeur aqueuse vers les espaces sous-conjonctivaux, avec diminution de la pression intraoculaire.¦Cette technique implique uniquement une dissection d'un volet scléral superficiel , sans volet scléral profond comme d'une sclérectomie profonde classique.¦Les modes de fonctionnement de cette sclérectomie profonde modifiée sont explorés par UBM, qui donne des images à haute résolution, semblables à des coupes anatomiques. Le volume de l'espace intrascléral créé artificiellement peut en effet être mesuré et mis en corrélation avec la pression intraoculaire et donc avec le taux de succès. Les différents types d'échogénécité de la bulle de filtration sous-conjonctivale provoquée par la dérivation de l'humeur aqueuse sont également observés. La présence éventuelle d'une filtration supplémentaire au niveau choroïdien est aussi détectée.¦De février 2007 à juin 2008, nous avons suivi chez les vingt six yeux des vingt six patients le volume intrascléral, la filtration sous-conjonctivale et la filtration choroïdienne le cas échéant, de même que l'acuité visuelle, la pression intraoculaire, le nombre de traitement antihypertenseur topique et les complications.¦Les résultats démontrent une réduction de 41 % par rapport à la pression intraoculaire préopératoire, ce qui est statistiquement significatif (p<0.0005). En ce qui concerne l'acuité visuelle, les valeurs demeurent stables. Par ailleurs, le nombre de médicaments antiglaucomateux diminue de façon significative de 2.5 ± 1.2 en préopératoire à 0.7 ± 1.0 au dernier examen (p<0.0005). Le volume de l'espace intrascléral, apparaissant toujours en échographie d'aspect fusiforme, n'est pas corrélé de façon significative avec un meilleur succès chirurgical bien que l'on aperçoive une tendance à une corrélation entre un plus grand volume et une pression intraoculaire plus basse.¦La classification la bulle de filtration se fait selon les 4 catégories de bulle de filtration décrites dans la littérature. La répartition révèle une majorité de type L soit hypoéchogène: 15/26 (58%) et une proportion identique, soit, 4/26 (16%), de bulles hyperéchogènes (type H) et encapsulées (type E); les bulles de filtration plates et hyperéchogènes (type F) sont les moins nombreuses 3/26 (11 %).¦La ligne hyporéflective visible dans 19 % des cas entre la sclère et la choroïde représentant potentiellement un drainage suprachoroïdien, n'est pas associée statistiquement à une meilleure filtration et une pression intraoculaire plus basse mais demeure une troisième voie de filtration, en plus de la filtration sous-conjonctivale et intrasclérale.¦En conclusion, cette technique différente, offrant une plus grande sécurité et des résultats satisfaisants sur l'abaissement de la pression intraoculaire, peut être, dans certains cas, une alternative à la sclérectomie profonde classique ,dont elle partage les mécanismes de filtration objectivés par ultrasonographic biomicrioscopique.
Resumo:
The most widely used formula for estimating glomerular filtration rate (eGFR) in children is the Schwartz formula. It was revised in 2009 using iohexol clearances with measured GFR (mGFR) ranging between 15 and 75 ml/min × 1.73 m(2). Here we assessed the accuracy of the Schwartz formula using the inulin clearance (iGFR) method to evaluate its accuracy for children with less renal impairment comparing 551 iGFRs of 392 children with their Schwartz eGFRs. Serum creatinine was measured using the compensated Jaffe method. In order to find the best relationship between iGFR and eGFR, a linear quadratic regression model was fitted and a more accurate formula was derived. This quadratic formula was: 0.68 × (Height (cm)/serum creatinine (mg/dl))-0.0008 × (height (cm)/serum creatinine (mg/dl))(2)+0.48 × age (years)-(21.53 in males or 25.68 in females). This formula was validated using a split-half cross-validation technique and also externally validated with a new cohort of 127 children. Results show that the Schwartz formula is accurate until a height (Ht)/serum creatinine value of 251, corresponding to an iGFR of 103 ml/min × 1.73 m(2), but significantly unreliable for higher values. For an accuracy of 20 percent, the quadratic formula was significantly better than the Schwartz formula for all patients and for patients with a Ht/serum creatinine of 251 or greater. Thus, the new quadratic formula could replace the revised Schwartz formula, which is accurate for children with moderate renal failure but not for those with less renal impairment or hyperfiltration.
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.
Resumo:
The search for new renewable materials has intensified in recent years. Pulp and paper mill process streams contain a number of potential compounds which could be used in biofuel production and as raw materials in the chemical, food and pharmaceutical industries. Prior to utilization, these compounds require separation from other compounds present in the process stream. One feasible separation technique is membrane filtration but to some extent, fouling still limits its implementation in pulp and paper mill applications. To mitigate fouling and its effects, foulants and their fouling mechanisms need to be well understood. This thesis evaluates fouling in filtration of pulp and paper mill process streams by means of polysaccharide model substance filtrations and by development of a procedure to analyze and identify potential foulants, i.e. wood extractives and carbohydrates, from fouled membranes. The model solution filtration results demonstrate that each polysaccharide has its own fouling mechanism, which also depends on the membrane characteristics. Polysaccharides may foul the membranes by adsorption and/or by gel/cake layer formation on the membrane surface. Moreover, the polysaccharides interact, which makes fouling evaluation of certain compound groups very challenging. Novel methods to identify wood extractive and polysaccharide foulants are developed in this thesis. The results show that it is possible to extract and identify wood extractives from membranes fouled in filtration of pulp and paper millstreams. The most effective solvent was found to be acetone:water (9:1 v/v) because it extracted both lipophilic extractives and lignans at high amounts from the fouled membranes and it was also non-destructive for the membrane materials. One hour of extraction was enough to extract wood extractives at high amounts for membrane samples with an area of 0.008 m2. If only qualitative knowledge of wood extractives is needed a simplified extraction procedure can be used. Adsorption was the main fouling mechanism in extractives-induced fouling and dissolved fatty and resin acids were mostly the reason for the fouling; colloidal fouling was negligible. Both process water and membrane characteristics affected extractives-induced fouling. In general, the more hydrophilic regenerated cellulose (RC) membrane fouled less that the more hydrophobic polyethersulfone (PES) and polyamide (PA) membranes independent of the process water used. Monosaccharide and uronic acid units could also be identified from the fouled synthetic polymeric membranes. It was impossible to analyze all monosaccharide units from the RC membrane because the analysis result obtained contained degraded membrane material. One of the fouling mechanisms of carbohydrates was adsorption. Carbohydrates were not potential adsorptive foulants to the sameextent as wood extractives because their amount in the fouled membranes was found to be significantly lower than the amount of wood extractives.