715 resultados para Filament winding


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cost-effective glass-reinforced thermoplastic matri x towpregs produced by a powder coating line were used to manufacture composite pipes by fi lament winding. A conventional 6 axes filament-winding equipment was adapted for processi ng such structures. The influence of the filament winding speed and mandrel temperature on t he composite final properties was studied in the present work. An optimized processin g window was established by comparing the composite theoretical expected mechanical prope rties with the experimentally obtained ones. The final properties determined on the produc ed pipes and structures and the technological changes introduced to the conventiona l filament-winding equipment will be presented and discussed. Besides the processing des cription and conditions, it will be presented the relationship between processing condi tions and mechanical properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pipelines for the transport of crude oil from the production wells to the collecting stations are named production lines . These pipes are subjected to chemical and electrochemical corrosion according to the environment and the type of petroleum transported. Some of these lines, depending upon the composition of the fluid produced, may leak within less than one year of operation due to internal corrosion. This work aims at the development of composite pipes with an external protecting layer of high density polyurethane for use in production lines of onshore oil wells, meeting operational requirements. The pipes were manufactured using glass fibers, epoxy resin, polyester resin, quartz sand and high density polyurethane. The pipes were produced by filament winding with the deposition of high density polyurethane on the external surface and threaded ends (API 15 HR/PM-VII). Three types of pipes were manufactured: glass/epoxy, glass/epoxy with an external polyurethane layer and glass/epoxy with an intermediate layer of glass fiber, polyester, sand and with an external polyurethane layer. The three samples were characterized by Scanning Electronic Microscopy (SEM) and for the determination of constituent content. In addition, the following tests were conducted: hydrostatic test, instant rupture, shorttime failure pressure, Gardner impact, transverse stiffness and axial tension. Field tests were conducted in Mossoró RN (BRAZIL), where 1,677 meters of piping were used. The tests results of the three types of pipes were compared in two events: after two months from manufacturing of the samples and after nine months of field application. The results indicate that the glass/epoxy pipes with an intermediate layer of fiber glass composite, polyester e sand and with an external layer of high density polyurethane showed superior properties as compared to the other two and met the requirements of pressure class, axial tensile strength, transverse stiffness, impact and environmental conditions, for onshore applications as production lines

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fillers are often added in composites to enhance performance and/or to reduce cost. Fiberglass pipes must meet performance requirements and industrial sand is frequently added for the pipe to be cost competitive. The sand is added to increase pipe wall thickness, thus increase pipe stiffness. The main goal of the present work is to conduct an experimental investigation between pipes fabricated with and without de addition of sand, to be used in the petroleum industry. Pipes were built using E-glass fibers, polyester resin and siliceous sand. The fabrication process used hand lay up and filament winding and was divided in two different parts: the liner and the structural wall. All tested pipes had the same liner, but different structural wall composition, which is the layer where siliceous sand may be added or not. The comparative investigation was developed considering the results of longitudinal tensile tests, hoop tensile tests, hydrostatic pressure leak tests and parallel-plate loading stiffness tests. SEM was used to analyze if the sand caused any damage to the glass fibers, during the fabrication process, because of the fiber-sand contact. The procedure was also used to verify the composite conditions after the hydrostatic pressure leak test. The results proved that the addition of siliceous sand reduced the leak pressure in about 17 %. In the other hand, this loss in pressure was compensated by a stiffness increment of more than 380 %. MEV analyses show that it is possible to find damage on the fiber-sand contact, but on a very small amount. On most cases, the contact occurs without damage evidences. In summary, the addition of sand filler represented a 27.8 % of cost reduction, when compared to a pipe designed with glass fiber and resin only. This cost reduction combined to the good mechanical tests results make siliceous sand filler suitable for fiberglass pressure pipes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

One of the key processing parameters in thermoset composites manufacturing is to have an optimum balance between open time and cure time. Long open times followed with a fast cure profile (also referred as snap cure or “hockey stick” shaped profiles) are required on applications like Pultrusion, Filament Winding, Resin Transfer Molding (RTM) and Infusion. In this work, several factors affecting the reactivity of a base line polyurethane formulation were studied. The addition of different components such as internal mold release agents, cross-linker, polyols having different molecular structure and isocyanates having different functionality were studied. A literature search was conducted to identify the main catalyst packages existing in the market. The reactivity of catalyst based on tertiary amines, orgamometallic salts, and co-catalyst of amine-organometallic complexes was characterized. Addition of quelants agents such as thioglycerol and acetyl acetone to delay the catalyst activity were also considered. As a consequence of this work a vast reactivity map was generated. This should guide the formulation designer in future product generations for the further development of the mentioned applications. Recommendations on measurements systems and further areas of exploration are also given.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aunque las primeras fábricas de tubos de poliéster reforzado con fibra de vidrio en España datan del año 1984, no es sino hasta el año 1996 cuando se comienza su utilización masiva como un sustituto de las tuberías de fribrocemento, que ya habían sido prohibidas por la legislación, debido a los efectos cancerígenos de este material. Desde entonces se ha prodigado la utilización de todas las diferentes tipologías de esta clase de tubería, de conformidad a los procesos de fabricación empleados que se encuentran recopilados en el AWWA Manual M45 (Fiberglass Pipe Design), obteniéndose muy diversos resultados. Durante estos años, ha surgido una creciente preocupación en los usuarios de este tipo de tuberías dadas las continuas y numerosas averías en todo el ámbito geográfico. Esto ha promovido el desarrollo de la presente investigaicón, que se ha dividido en dos partes y que ha concluido con la determinación de un nuevo mecanismo específico de fractura. La primera parte se centró en la obtención y desarrollo del modelo teórico que hemos venido a denominar como "Teoría de la Caja Mecánicamente Contaminada", y que está basado en la contaminación o separación por un impacto de dos de las tres capas que forman la tubería, la capa intermedia de arena y la capa más interna o "inner layer". La consecuencia es la disminución del canto resistente, la rotura del inner layer y la entrada de fluido a la capa de arena. Para la evaluación de la magnitud de esta separación se ha desarrollado un modelo analítico que ha determinado la existencia de una relación cuadrática que la rige, y que ha sido verificado mediante ensayos de impacto sobre probetas de tuberías, alcanzando ajustes de hasta el 92%. Así, se ha determinado que impactos de muy baja intensidad, del entorno de 90 a 160 Julios en tuberías Filament Winding continuo PN 16-20 (de 800 a 1000mm) pueden comprometer seriamente la integridad estructural de la tubería sin dejar, en un principio, muesca o traza alguna que pueda alertar del problema. Los siguientes pasos en el estudio se dirigieron a determinar qué otros mecanismos, aparte del golpe, podrían contaminar la tubería y a estudiar el consiguiente avance de la fractura a las capas externas. Se trataba además de analizar la aparición en el tubo de unas misteriosas manchas en forma de "piel de leopardo" y de otros fenómenos aparecidos en las averías como que algunas de las deformaciones de la rotura por presión interna son hacia el interior del tubo y no al revés, como habría sido de esperar a priori. Se optó entonces por comenzar la que ha constituido la segunda parte de la investigación. Para ello se recurrió a realizar ensayos hidráulicos en banco de pruebas a alta presión, cuyos resultados fueron sorprendentes al descubrir que en el proceso se producía la hidrólisis de la resina de poliéster no catalizada que fluía hacia el exterior del tubo. Como consecuencia se llevaron a cabo nuevos ensayos físicos y químicos para estudiar la migración del material y la hidrólisis producida en el proceso de fractura. En este estudio, resultó muy relevante el hecho de sobrepasar o no la presión que producía el desagarro entre las capas del tubo. En definitiva, en esta investigación, que ha constado de estudios analíticos y estudios experimentales, químicos y numéricos, se ha determinado un nuevo mecanismo de fractura que explica gran parte de los fallos acontecidos en las tuberías de poliéster reforzado con fibra de vidrio. Como aplicación se exponen recomendaciones para mejorar el comportamiento mecánico de esta tipología y evitar así los sobrecostes millonarios producidos por su reposición. Numerous and continuous failures in fiberglass reinforced polyester pipes of different companies and manufacturing processes of the AWWA Manual M45 (Fiberglass Pipe Design), have prompted the development of this research, that has concluded with a specific mechanism describing pipe fractures. This research was carried out via two independent studies. The first one is the development of the hypothesis that turned into the Mechanically Contaminated Layer Theory. This theory describes the fracture mchanism which explains a significant part of massive failures due to the existence of a sand layer placed near the neutral axis in the core making the composite very sensitive to impacts in fibreglass reinforced polyester pipes. These failures create interface delamination and consequently fluid can leak into supporting sand backfill thereby iniating the fracture process. In order to assess the delimination magnitude, an analytic method is developed and a squared root law between delamination and energy applied proposed. Vertical blunt ram testts on samples extracted from complete pipes have been carried out to verify this theory, reaching a goodness of fit up to 92%. It is concluded that low energy impacts, around 90-160J in 800-1000mm diameter PN 16-20 continuous filament winding pipes, can seriously compromise their structural integraty with no external trace. The next step in the study was to determine what other mechanism, apart from the brittle hit, could contaminate the pipe and to analyse the consequente advance of the fracture to the external layers. Another aim was to analyse two phenomena occurred in real pipe failures. The first one is the appearance on the tube of "leopard fur" stains on some of the analysed failures, and the other phenomenon is the "inverse fracture", in which the deformations of the failure due to internal pressure are towards the inside of the tube and not the other way round, as it would be expected. It was then chosen to follow a new branch of the investigation by hydraulic high-pressure bench tests that study seepage and load transmission. The results were very surprising as it was discovered that in the process, hydrolysis of the non-catalysed polyester resin occured, flowing towards the outer of the pipe, which entailed the development of chemical and physical tests of the exuded material to study material migration and hydrolysis of the fracture process. In this particular study it was relevant to exceed or not the pressure that produced the rip between the layers of the tube. In conclusion, a new breakage mechanism in FRP pies with sand-filled layer has been found, which explains a high part of the failure global cases. The whole failure process is justified by the Mechanically Contaminated Layer Theory, which has been corroborated by means of analytical, numerical and experimental studies. Several recommendations are also provided in order to improve the mechanical behaviour of this typology and avoid the millionaire overruns generated by its massive failures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

"A series of twenty thousand ratios was compiled primarily for a filament winding machine with a three-step transmission system."

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Every year in the US and other cold-climate countries considerable amount of money is spent to restore structural damages in conventional bridges resulting from (or “caused by”) salt corrosion in bridge expansion joints. Frequent usage of deicing salt in conventional bridges with expansion joints results in corrosion and other damages to the expansion joints, steel girders, stiffeners, concrete rebar, and any structural steel members in the abutments. The best way to prevent these damages is to eliminate the expansion joints at the abutment and elsewhere and make the entire bridge abutment and deck a continuous monolithic structural system. This type of bridge is called Integral Abutment Bridge which is now widely used in the US and other cold-climate countries. In order to provide lateral flexibility, the entire abutment is constructed on piles. Piles used in integral abutments should have enough capacity in the perpendicular direction to support the vertical forces. In addition, piles should be able to withstand corrosive environments near the surface of the ground and maintain their performance during the lifespan of the bridge. Fiber Reinforced Polymer (FRP) piles are a new type of pile that can not only accommodate large displacements, but can also resist corrosion significantly better than traditional steel or concrete piles. The use of FRP piles extends the life of the pile which in turn extends the life of the bridge. This dissertation studies FRP piles with elliptical shapes. The elliptical shapes can simultaneously provide flexibility and stiffness in two perpendicular axes. The elliptical shapes can be made using the filament winding method which is a less expensive method of manufacturing compared to the pultrusion or other manufacturing methods. In this dissertation a new way is introduced to construct the desired elliptical shapes with the filament winding method. Pile specifications such as dimensions, number of layers, fiber orientation angles, material, and soil stiffness are defined as parameters and the effects of each parameter on the pile stresses and pile failure have been studied. The ANSYS software has been used to model the composite materials. More than 14,000 nonlinear finite element pile models have been created, each slightly different from the others. The outputs of analyses have been used to draw curves. Optimum values of the parameters have been defined using generated curves. The best approaches to find optimum shape, angle of fibers and types of composite material have been discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pipelines for the transport of crude oil from the production wells to the collecting stations are named production lines . These pipes are subjected to chemical and electrochemical corrosion according to the environment and the type of petroleum transported. Some of these lines, depending upon the composition of the fluid produced, may leak within less than one year of operation due to internal corrosion. This work aims at the development of composite pipes with an external protecting layer of high density polyurethane for use in production lines of onshore oil wells, meeting operational requirements. The pipes were manufactured using glass fibers, epoxy resin, polyester resin, quartz sand and high density polyurethane. The pipes were produced by filament winding with the deposition of high density polyurethane on the external surface and threaded ends (API 15 HR/PM-VII). Three types of pipes were manufactured: glass/epoxy, glass/epoxy with an external polyurethane layer and glass/epoxy with an intermediate layer of glass fiber, polyester, sand and with an external polyurethane layer. The three samples were characterized by Scanning Electronic Microscopy (SEM) and for the determination of constituent content. In addition, the following tests were conducted: hydrostatic test, instant rupture, shorttime failure pressure, Gardner impact, transverse stiffness and axial tension. Field tests were conducted in Mossoró RN (BRAZIL), where 1,677 meters of piping were used. The tests results of the three types of pipes were compared in two events: after two months from manufacturing of the samples and after nine months of field application. The results indicate that the glass/epoxy pipes with an intermediate layer of fiber glass composite, polyester e sand and with an external layer of high density polyurethane showed superior properties as compared to the other two and met the requirements of pressure class, axial tensile strength, transverse stiffness, impact and environmental conditions, for onshore applications as production lines

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The A1763 superstructure at z = 0.23 contains the first galaxy filament to be directly detected using mid-infrared observations. Our previous work has shown that the frequency of starbursting galaxies, as characterized by 24 mu m emission is much higher within the filament than at either the center of the rich galaxy cluster, or the field surrounding the system. New Very Large Array and XMM-Newton data are presented here. We use the radio and X-ray data to examine the fraction and location of active galaxies, both active galactic nuclei (AGNs) and starbursts (SBs). The radio far-infrared correlation, X-ray point source location, IRAC colors, and quasar positions are all used to gain an understanding of the presence of dominant AGNs. We find very few MIPS-selected galaxies that are clearly dominated by AGN activity. Most radio-selected members within the filament are SBs. Within the supercluster, three of eight spectroscopic members detected both in the radio and in the mid-infrared are radio-bright AGNs. They are found at or near the core of A1763. The five SBs are located further along the filament. We calculate the physical properties of the known wide angle tail (WAT) source which is the brightest cluster galaxy of A1763. A second double lobe source is found along the filament well outside of the virial radius of either cluster. The velocity offset of the WAT from the X-ray centroid and the bend of the WAT in the intracluster medium are both consistent with ram pressure stripping, indicative of streaming motions along the direction of the filament. We consider this as further evidence of the cluster-feeding nature of the galaxy filament.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a magnetic resonance imaging equipment, gradient and shim coils are needed to produce a spatially varying magnetic field throughout the sample being imaged. Such coils consist of turns of wire wound on the surface of a cylindrical tube. Shim coils in particular, must sometimes be designed to produce complicated magnetic fields to correct for impurities. Streamline patterns for shim coils are much more complicated than those for gradient coils, In this work we present a detailed analysis of streamline methods and their application to shim coil design, A method is presented for determining the winding patterns to generate these complicated fields. (C) 2002 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) for cancer is a therapeutic modality in the treatment of tumors in which visible light is used to activate a photosensitizer. Cell membranes have been identified as an important intracellular target for singlet oxygen produced during the photochemical pathway. This study analyzed the cytotoxicity in specific cellular targets of a photosensitizer used in PDT in vitro. The photosensitizing effects of chloroaluminum phthalocyanine liposomal were studied on the mitochondria, cytoskeleton and endoplasmic reticulum of HeLa cells. Cells were irradiated with a diode laser working at 670 nm, energy density of 4.5 J/cm(2) and power density of 45 mW/cm(2). Fluorescence microscopic analysis of the mitochondria showed changes in membrane potential. After PDT treatment, the cytoskeleton and endoplasmic reticulum presented basic alterations in distribution. The combined effect of AlPHCl liposomal and red light in the HeLa cell line induced photodamage to the mitochondria, endoplasmic reticulum and actin filaments in the cytoskeleton. (c) 2008 International Federation for Cell Biology. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a new approach for designing planar gradient coils is outlined for the use in an existing MRI apparatus. A technique that allows for gradient field corrections inside the diameter-sensitive volume is deliberated. These corrections are brought about by making changes to the wire paths that constitute the coil windings, and hence, is called the path correction method. The existing well-known target held method is used to gauge the performance of a typical gradient coil. The gradient coil design methodology is demonstrated for planar openable gradient coils that can be inserted into an existing MRI apparatus. The path corrected gradient coil is compared to the coil obtained using the target field method. It is shown that using a wire path correction with optimized variables, winding patterns that can deliver high magnetic gradient field strengths and large imaging regions can be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is presented for calculating the currents and winding patterns required to design independent zonal and tesseral shim coils for magnetic resonance imaging. Both actively shielded and unshielded configurations are considered, and the region of interest can be located asymmetrically with respect to the coil's length. Streamline, target-field and Fourier-series methods are utilized. The desired target-field is specified at two cylindrical radii, on and inside a circular conducting cylinder of length 2L and radius a. The specification is over some asymmetric portion pL < z < qL of the coil's length (-1 < p < q < 1). Arbitrary functions are used in the outer sections, -L < z < pL and qL < z < L, to ensure continuity of the magnetic field across the entire length of the coil. The entire field is then periodically extended as a half-range cosine Fourier series about either end of the coil. The resultant Fourier coefficients are then substituted into the Fourier-series expressions for the internal and external magnetic fields, and current densities and stream functions on both the primary coil and shield. A contour plot of the stream function directly gives the required coil winding patterns. Spherical harmonic analysis and shielding analysis on field calculations from a ZX shim coil indicate that example designs and theory are well matched.