807 resultados para Fibrous Dressings


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract : In order to analyze the role of a new structured fibrous dressing in the proliferative stage of chronic wound healing in hard to heal wounds, a case study was performed on a stagnant venous ulcer, which remained non-healed in the past 7 months. All chronicity factors that could affect wound healing were excluded, including biofilm (with the use of polihexanide+betaine, Prontosan range), and compression therapy was provided. The results were very interesting with healing achieved in 7 weeks of treatment. Most of times it is not easy to find/select a dressing to promote granulation and epithelisation, once ideal cleaning/debridement and bioburden control are achieved. Some dressings do not provide a good healing rate, lead to bioburden elevation during time and recurrence in the use of antimicrobials. Other options to promote proliferation are very expensive and need a secondary dressing. Treatment with kerrafibre showned to be very cost effective. Its is also implicit the important role of advanced wound care centers versus conventional care.This case study was originally presented as a poster at Wounds UK 2014 Conference, at Harrogate, England, United Kingdom.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work describes the design and assembly of multifunctional and cost-efficient composite fiber nonwovens as semi-occlusive wound dressings using a simple electrospinning process to incorporate a variety Of functional components into an Ultrathin fiber. These components include non-hydrophilic poly(L-lactide) (PLLA) as fibrous backbone, hydrophilic poly(vinyl pyrrolidone)iodine (PVP-I), TiO2 nanoparticles, zinc chloride as antimicrobial, odor-controlling, and antiphlogistic agents, respectively. The process of synthesis starts with a multicomponent solution Of PLLA, PVP, TiO2 nanoparticles plus zinc chloride, in which TiO2 nanoparticles are synthesized by in situ hydrolysis of TiO2 precursors in a PVP Solution for the sake of obtaining the particle-uniformly dispersive solution. Subsequent electrospinning generates the corresponding composite fibers. A further iodine vapor treatment to the composite fibers combines iodine with PVP to produce the PVP-I complexes. Experiments indicate that the assembled composite fibers (300-400 nm) possess the ointment-releasing characteristic and the phase-separate, core-sheath structures in which PVP-I residing in fiber Surface layer becomes the sheath, and PLLA distributing inside the fiber acts as the core.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of solid strong acid catalysts were synthesised from fibrous ZrO2/Al2O3 core and shell nanocomposites. In this series, the zirconium molar percentage was varied from 2 % to 50 %. The ZrO2/Al2O3 nanocomposites and their solid strong acid counterparts were characterised by a variety of techniques including 27Al magic angle spinning nuclear magnetic resonance (MAS-NMR), scanned electronic microscopy (SEM), transmission electron microscope (TEM), X-ray photoelectron spectroscopy (XPS), Nitrogen adsorption and infrared emission spectroscopy (IES). NMR results show that the interaction between zirconia species and alumina strongly correlates with pentacoordinated aluminium sites. This can also be detected by the change in binding energy of the 3d electrons of the zirconium. The acidity of the obtained solid acids was tested by using them as catalysts for the benzolyation of toluene. It was found that a sample with a 50 % zirconium molar percentage possessed the highest surface acidity equalling that of pristine sulfated zirconia despite the reduced mass of zirconia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Greater research utilisation in cancer nursing practice is needed, in order to provide well-informed and effective nursing care to people affected by cancer. This paper aims to report on the implementation of evidence-based practice in a tertiary cancer centre. Methods: Using a case report design, this paper reports on the use of the Collaborative Model for Evidence Based Practice (CMEBP) in an Australian tertiary cancer centre. The clinical case is the uptake of routine application of chlorhexidine-impregnated sponge dressings for preventing centrally inserted catheter-related bloodstream infections. In this case report, a number of processes that resulted in a service-wide practice change are described. Results: This model was considered a feasible method for successful research utilisation. In this case report, chlorhexidine-impregnated sponge dressings were proposed and implemented in the tertiary cancer centre with an aim of reducing the incidence of centrally inserted catheter-related bloodstream infections and potentially improving patient health outcomes. Conclusion: The CMEBP is feasible and effective for implementing clinical evidence into cancer nursing practice. Cancer nurses and health administrators need to ensure a supportive infrastructure and environment for clinical inquiry and research utilisation exists, in order to enable successful implementation of evidence-based practice in their cancer centres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pilot study was conducted to compare four types of dressings used to treat skin tears in nursing home residents. Wounds treated with a non-occlusive dressing healed more quickly than those dressed with occlusive dressings. The results suggest that ease of use and product wastage are important considerations when treating skin tears. The pilot study also highlights the need for further research into skin tear management and the need for ongoing education for nurses regarding skin integrity risk assessment and product information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanocomposites are recently known to be among the most successful materials in biomedical applications. In this work we sought to fabricate fibrous scaffolds which can mimic the extra cellular matrix of cartilaginous connective tissue not only to a structural extent but with a mechanical and biological analogy. Poly(3-hydroxybutyrate) (P3HB) matrices were reinforced with 5, 10 and 15 %wt hydroxyapatite (HA) nanoparticles and electrospun into nanocomposite fibrous scaffolds. Mechanical properties of each case were compared with that of a P3HB scaffold produced in the same processing condition. Spectroscopic and morphological observations were used for detecting the interaction quality between the constituents. Nanoparticles rested deep within the fibers of 1 μm in diameter. Chemical interactions of hydrogen bonds linked the constituents through the interface. Maximum elastic modulus and mechanical strength was obtained with the presence of 5%wt hydroxyapatite nanoparticles. Above 10%wt, nanoparticles tended to agglomerate and caused the entity to lose its mechanical performance; however, viscoelasticity interfered at this concentration and lead to a delayed failure. In other words, higher elongation at break and a massive work of rupture was observed at 10%wt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In the paediatric population, pain and distress associated with burn injuries during wound care procedures remain a constant challenge. Although silver dressings are the gold standard for burn care in Australasia, very few high-level trials have been conducted that compare silver dressings to determine which will provide the best level of care clinically. Therefore, for paediatric patients in particular, identifying silver dressings that are associated with lower levels of pain and rapid wound re-epithelialisation is imperative. This study will determine whether there is a difference in time to re-epithelialisation and pain and distress experienced during wound care procedures among Acticoat, Acticoat combined with Mepitel and Mepilex Ag dressings for acute, paediatric partial thickness burns. METHODS/DESIGN: Children aged 0 to 15 years with an acute partial thickness (superficial partial to deep partial thickness inclusive) burn injury and a burn total body surface area of dressings. DISCUSSION: The results of this study will determine the effects of three commonly used silver and silicone burn dressing combinations on the rate of wound re-epithelialisation and pain experienced during dressing procedures in acute, paediatric partial thickness burn injuries. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12613000105741.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a method to test the cytotoxicity of wound dressings, ointments, creams and gels used in our Burn Centre, by placing them on a permeable Nunc Polycarbonate cell culture insert, incubated with a monolayer of cells (HaCaTs and primary human keratinocytes). METHODS: We performed two different methods to determine the relative toxicity to cells. (1) Photo visualisation: The dressings or compounds were positioned on the insert's membrane which was placed onto the monolayer tissue culture plate. After 24 h the surviving adherent cells were stained with Toluidine Blue and photos of the plates were taken. The acellular area of non-adherent dead cells which had been washed off with buffer was measured as a percentage of the total area of the plate. (2) Cell count of surviving cells: After 24 h incubation with the test material, the remaining cells were detached with trypsin, spun down and counted in a Haemocytometer with Trypan Blue, which differentiates between live and dead cells. RESULTS: Seventeen products were tested. The least cytotoxic products were Melolite, White soft Paraffin and Chlorsig1% Ointment. Some cytotoxicity was shown with Jelonet, Mepitel((R)), PolyMem((R)), DuoDerm((R)) and Xeroform. The most cytotoxic products included those which contained silver or Chlorhexidine and Paraffin Cream a moisturizer which contains the preservative Chlorocresol. CONCLUSION: This in vitro cell culture insert method allows testing of agents without direct cell contact. It is easy and quick to perform, and should help the clinician to determine the relative cytotoxicity of various dressings and the optimal dressing for each individual wound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven L-phenylalanine based alkyl (monopolar) and alkanediyl (bipolar) derivatives are synthesized; while the bipolar urethane amides form gels and show strong adhesive properties, the monopolar analogues form fibrous nanoscopic cloth-like tapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FCMIN) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the stress, making it vulnerable, and it is the big curvature of the lumen contour over FC which may result in increased plaque stress. We aimed to assess critical stresses at FCMIN and the maximum lumen curvature over FC (LCMAX) and quantify the difference to see which vulnerable site had the highest critical stress and was, therefore, at highest risk of rupture. One hundred patients underwent high resolution carotid magnetic resonance (MR) imaging. We used 352 MR slices with delineated atherosclerotic components for the simulation study. Stresses at all the integral nodes along the lumen surface were calculated using the finite-element method. FCMIN and LCMAX were identified, and critical stresses at these sites were assessed and compared. Critical stress at FC MIN was significantly lower than that at LCMAX (median: 121.55 kPa; inter quartile range (IQR) = [60.70-180.32] kPa vs. 150.80 kPa; IQR = [91.39-235.75] kPa, p < 0.0001). If critical stress at FCMIN was only used, then the stress condition of 238 of 352 MR slices would be underestimated, while if the critical stress at LCMAX only was used, then 112 out of 352 would be underestimated. Stress analysis at FCMIN and LCMAX should be used for a refined mechanical risk assessment of atherosclerotic plaques, since material failure at either site may result in rupture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: Inflammation is a risk factor the vulnerable atheromatous plaque. This can be detected in vivo on high-resolution magnetic resonance (MR) imaging using a contrast agent, Sinerem™, an ultra-small super-paramagnetic iron oxide (USPIO). The aim of this study was to explore whether there is a difference in the degree of MR defined inflammation using USPIO particles, between symptomatic and asymptomatic carotid plaques. We report further on its T1 effect of enhancing the fibrous cap, which may allow dual contrast resolution of carotid atheroma. Methods: Twenty patients with carotid stenosis (10 symptomatic and 10 asymptomatic) underwent multi-sequence MR imaging before and 36 h post-USPIO infusion. Images were manually segmented into quadrants and signal change in each quadrant was calculated following USPIO administration. Mean signal change across all quadrants were compared between the two groups. Results: Symptomatic patients had significantly more quadrants with a signal drop than asymptomatic individuals (75% vs. 32%, p < 0.01). Asymptomatic plaques had more quadrants with signal enhancement than symptomatic ones (68% vs. 25%, p < 0.05); their mean signal change was also higher (46% vs. 15%, p < 0.01) and this appeared to correlate with a thicker fibrous cap on histology. Conclusions: Symptomatic patients had more quadrants with signal drop suggesting larger inflammatory infiltrates. Asymptomatic individuals showed significantly more enhancement possibly suggesting greater stability as a result of thicker fibrous caps. However, some asymptomatic plaques also had focal areas of signal drop, suggesting an occult macrophage burden. If validated by larger studies, USPIO may be a useful dual contrast agent able to improve risk stratification of patients with carotid stenosis and inform selection for intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eleven carotid atherothrombotic plaque samples were harvested from patients. Three samples that were highly calcified were discarded, while eight yielded results. The elastic properties of the material were estimated by fitting the measured indentation response to finite element simulations. The methodology was refined and its accuracy quantified using a synthetic rubber. The neo-Hookean form of the material model gave a good fit to the measured response of the tissue. The inferred shear modulus μ was found to be in the range 7-100 kPa, with a median value of 11 kPa. A review of published materials data showed a wide range of material properties for human atherothrombotic tissue. The effects of anisotropy and time dependency in these published results were highlighted. The present measurements were comparable to the static radial compression tests of Lee et al, 1991 [Structure-dependent dynamic behaviour of fibrous caps from human atherosclerotic plaques. Circulation 83, 1764-1770].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose Acute cerebral ischemic events are associated with rupture of vulnerable carotid atheroma and subsequent thrombosis. Factors such as luminal stenosis and fibrous cap thickness have been thought to be important risk factors for plaque rupture. We used a flow-structure interaction model to simulate the interaction between blood flow and atheromatous plaque to evaluate the effect of the degree of luminal stenosis and fibrous cap thickness on plaque vulnerability. Methods A coupled nonlinear time-dependent model with a flow-plaque interaction simulation was used to perform flow and stress/strain analysis in a stenotic carotid artery model. The stress distribution within the plaque and the flow conditions within the vessel were calculated for every case when varying the fibrous cap thickness from 0.1 to 2 mm and the degree of luminal stenosis from 10% to 95%. A rupture stress of 300 kPa was chosen to indicate a high risk of plaque rupture. A 1-sample t test was used to compare plaque stresses with the rupture stress. Results High stress concentrations were found in the plaques in arteries with >70% degree of stenosis. Plaque stresses in arteries with 30% to 70% stenosis increased exponentially as fibrous cap thickness decreased. A decrease of fibrous cap thickness from 0.4 to 0.2 mm resulted in an increase of plaque stress from 141 to 409 kPa in a 40% degree stenotic artery. Conclusions There is an increase in plaque stress in arteries with a thin fibrous cap. The presence of a moderate carotid stenosis (30% to 70%) with a thin fibrous cap indicates a high risk for plaque rupture. Patients in the future may be risk stratified by measuring both fibrous cap thickness and luminal stenosis.