999 resultados para Fiberoptic endoscopic evaluation of swallowing
Resumo:
Stroke is the most common neurological disease in adults that is associated with deglutition disorders. The presence of laryngeal sensitivity is very important in developing safe swallowing without risk of pulmonary complications. The aim of this study was to correlate laryngeal sensitivity with laryngeal penetration and tracheal aspiration after swallows of three food consistencies (puree, thickened liquid, and liquid) in poststroke individuals in the late phase. A cross-sectional clinical study was performed with 91 post-ischemic stroke individuals, with oropharyngeal dysphagia, who were in rehabilitation center treatment from 2009 to 2011. They had a mean age of 68.1 years and average time since injury was 22.6 months; 39 had injury to the right hemisphere and 52 had injury to the left hemisphere. All underwent fiberoptic endoscopic evaluation of swallowing and evaluation of laryngeal sensitivity by touching the tip of the endoscope to the arytenoids and aryepiglottic folds. The linear correlation coefficient of Spearman was applied to evaluate the correlation between laryngeal penetration and tracheal aspiration and the presence/absence of laryngeal sensitivity. There was a negative correlation between the observation of penetration and tracheal aspiration and laryngeal sensitivity, with all bolus consistencies (p < 0.001 for aspiration and p a parts per thousand currency sign 0.01 for penetration). The absence of laryngeal sensitivity determines the more frequent findings of penetration and tracheal aspiration. This sensory stimulus in the mucosa of the pharynx and larynx is an essential element for safe swallowing and its deficiency associated with altered motor activity can cause laryngeal penetration and aspiration in poststroke individuals regardless of food consistency.
Resumo:
Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.
The incidence of adenocarcinoma in Barrett's oesophagus and an evaluation of endoscopic surveillance
Resumo:
Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.
Resumo:
To study mastication and swallowing disorders in patients with temporomanclibular disorders (TMD). Objective: To investigate mastication and swallowing disorders in patients with severe TMD referred to surgery. Materials and Methods: Clinical and experimental study involving ten individuals with TMD submitted to deglutition videofluoroscopy. These patients did not have posterior teeth, mastication pain and food replacement in favor of pasty consistence food. The assessment of the oral and pharyngeal phases approached the following aspects: side of onset and preferential side for chewing, premature escape, remains of food residues in the oral cavity or in the pharyngeal recesses, number of necessary swallowing efforts, laryngeal penetration and/or tracheal aspiration. Results: During mastication and the oral phase we observed tongue compensatory movements upon chewing (n = 7; 70%), premature escape (n = 4; 40%), food remains in the cavity after swallowing (n = 5; 50%) and an excessive number of deglutition efforts (n = 5; 50%). On the pharyngeal phase we observed food remains in the valleculae (n = 6; 60%), in the pyriform sinuses (n = 4; 40%); laryngeal penetration (n = 1; 10%) and tracheal aspiration (n = 4; 40%). Conclusion: TMD patients may have alterations in their chewing and swallowing patterns, with laryngeal penetration and/or tracheal aspiration. The study indicates the need for a multidisciplinary assessment because of dysphagia in TMD patients.
Resumo:
Objectives: Current data do not provide enough information on how quality of life (QoL) evolves over time in cases of endoscopic thoracic sympathectomy (ETS). The purpose of this study was to ascertain whether the immediate improvement in QoL after the surgery was sustained until the fifth postoperative year. Methods: This was a prospective, nonrandomized and uncontrolled study. From March 2001 to December 2003, 475 consecutive patients with hyperhidrosis submitted to ETS were included. A QoL questionnaire was applied at the preoperative day, around the 30th postoperative day, and after the fifth year. Results: After excluding 22 patients who did not answer all the questions, we analyzed 453 patients. Their ages ranged from 11 to 57 years old, with a mean of 25.3 + 7.9 years, including 297 female patients (65.6%). All patients were assessed on three occasions: before surgery, around the 30th postoperative day, and after the fifth postoperative year. The QoL before surgery was considered to be poor or very poor for all patients. The QoL around 30 days after surgery was better in 412 patients (90.9%), the same in 27 patients (6.0%), and worse in 14 patients (3.1%). After 5 years, 409 patients (90.3%) were better, 27 (6.0%) were the same, and 14 (3.1%) were worse. There were no differences between these postoperative times according to the McNemar statistical test. Conclusion:The patients had an immediate improvement in QoL after ETS, and this improvement was sustained until the fifth postoperative year. (J Vase Surg 2012;55:154-6.)
Resumo:
REASONS FOR PERFORMING STUDY: Although endoscopic scoring of the tracheal septum thickness is used as a diagnostic tool for evaluation of lower airway disease, its clinical relevance and reliability have never been critically assessed in the horse. OBJECTIVES: To investigate if septum thickness scores (STS) are reliable and serve as a clinically useful indicator of lower airway disease status and/or inflammation. METHODS: The variance of STS attributable to the horse, observer and changes over time was determined. The distribution of STS in a population of clinically normal horses and correlations of STS with age, gender, as well as mucus accumulation and cell differentials of tracheobronchial secretions and bronchoalveolar lavage fluid were investigated. Effects of altered pulmonary ventilation, induced by different drugs, on STS were assessed. Finally, STS of horses affected with recurrent airway obstruction (RAO) were compared to those of clinically normal horses. RESULTS: Recorded STS showed excellent intra- and satisfactory interobserver agreement Established clinical, endoscopic and cytological measures of lower airway inflammation, i.e. mucus accumulation scores and airway neutrophilia, did not correlate with STS. In horses age > or = 10 years, septum scores were significantly higher (P = 0.022) than in younger horses. Septum thickness scores did not differ significantly between clinically normal and RAO-affected horses both in exacerbation and in remission. Horses with markedly increased breathing effort (i.e. with metacholine- or lobeline hydrochloride-challenge), often differed markedly (up to 1.9 scores), but the average of end-inspiratory and end-expiratory STS did not differ from baseline STS. CONCLUSIONS AND CLINICAL RELEVANCE: Endoscopic STS are a reproducible measure, but STS did not correlate with clinical, endoscopic and cytological findings indicative of RAO or inflammatory airway disease.
Resumo:
Current diagnostic methods for assessing the severity of articular cartilage degenerative conditions, such as osteoarthritis, are inadequate. There is also a lack of techniques that can be used for real-time evaluation of the tissue during surgery to inform treatment decision and eliminate subjectivity. This book, derived from Dr Afara’s doctoral research, presents a scientific framework that is based on near infrared (NIR) spectroscopy for facilitating the non-destructive evaluation of articular cartilage health relative to its structural, functional, and mechanical properties. This development is a component of the ongoing research on advanced endoscopic diagnostic techniques in the Articular Cartilage Biomechanics Research Laboratory of Professor Adekunle Oloyede at Queensland University of Technology (QUT), Brisbane Australia.
Resumo:
Drugs and surgical techniques may have harmful renal effects during the perioperative period. Traditional biomarkers are often insensitive to minor renal changes, but novel biomarkers may more accurately detect disturbances in glomerular and tubular function and integrity. The purpose of this study was first, to evaluate the renal effects of ketorolac and clonidine during inhalation anesthesia with sevoflurane and isoflurane, and secondly, to evaluate the effect of tobacco smoking on the production of inorganic fluoride (F-) following enflurane and sevoflurane anesthesia as well as to determine the effect of F- on renal function and cellular integrity in surgical patients. A total of 143 patients undergoing either conventional (n = 75) or endoscopic (n = 68) inpatient surgery were enrolled in four studies. The ketorolac and clonidine studies were prospective, randomized, placebo controlled and double-blinded, while the cigarette smoking studies were prospective cohort studies with two parallel groups. As a sign of proximal tubular deterioration, a similar transient increase in urine N-acetyl-beta-D-glucosaminidase/creatinine (U-NAG/crea) was noted in both the ketorolac group and in the controls (baseline vs. at two hours of anesthesia, p = 0.015) with a 3.3 minimum alveolar concentration hour sevoflurane anesthesia. Uncorrelated U-NAG increased above the maximum concentration measured from healthy volunteers (6.1 units/l) in 5/15 patients with ketorolac and in none of the controls (p = 0.042). As a sign of proximal tubular deterioration, U-glutathione transferase-alpha/crea (U-GST-alpha/crea) increased in both groups at two hours after anesthesia but a more significant increase was noted in the patients with ketorolac. U-GST-alpha/crea increased above the maximum ratio measured from healthy volunteers in 7/15 patients with ketorolac and in 3/15 controls. Clonidine diminished the activation of the renin-angiotensin aldosterone system during pneumoperitoneum; urine output was better preserved in the patients treated with clonidine (1/15 patients developed oliguria) than in the controls (8/15 developed oliguria (p=0.005)). Most patients with pneumoperitoneum and isoflurane anesthesia developed a transient proximal tubular deterioration, as U-NAG increased above 6.1 units/L in 11/15 patients with clonidine and in 7/15 controls. In the patients receiving clonidine treatment, the median of U-NAG/crea was higher than in the controls at 60 minutes of pneumoperitoneum (p = 0.01), suggesting that clonidine seems to worsen proximal tubular deterioration. Smoking induced the metabolism of enflurane, but the renal function remained intact in both the smokers and the non-smokers with enflurane anesthesia. On the contrary, smoking did not induce sevoflurane metabolism, but glomerular function decreased in 4/25 non-smokers and in 7/25 smokers with sevoflurane anesthesia. All five patients with S-F- ≥ 40 micromol/L, but only 6/45 with S-F- less than 40 micromol/L (p = 0.001), developed a S-tumor associated trypsin inhibitor concentration above 3 nmol/L as a sign of glomerular dysfunction. As a sign of proximal tubulus deterioration, U-beta 2-microglobulin increased in 2/5 patients with S-F- over 40 micromol/L compared to 2/45 patients with the highest S-F- less than 40 micromol/L (p = 0.005). To conclude, sevoflurane anesthesia may cause a transient proximal tubular deterioration which may be worsened by a co-administration of ketorolac. Clonidine premedication prevents the activation of the renin-angiotensin aldosterone system and preserves normal urine output, but may be harmful for proximal tubules during pneumoperitoneum. Smoking induces the metabolism of enflurane but not that of sevoflurane. Serum F- of 40 micromol/L or higher may induce glomerular dysfunction and proximal tubulus deterioration in patients with sevoflurane anesthesia. The novel renal biomarkers warrant further studies in order to establish reference values for surgical patients having inhalation anesthesia.
Resumo:
In this paper, new solutions to the problem of making measurements, of carbonation and chloride ingress, in particular, in concrete structures are considered. The approach has focused on the design, development, and use of fiber-optic sensors (FOSs), recognizing the need in that conventional devices are often either inaccurate, expensive, or unsuitable for encapsulation in the material. The sensors have been designed to monitor, in situ and nondestructively, relevant physical, and chemical changes in cementitious materials. Three different types of FOS were constructed, tested, and evaluated specifically for this application, these being a temperature sensor (based on the fluorescence decay) and pH and chloride sensors, based on sol-gel (solidified gel) technology with appropriate impregnated indicators. The sensors were all designed to be inserted into the structures and evaluated under the harshest conditions, i.e., being mounted when the mortar is poured and thus tested in situ, with the temperature and pH sensors successfully embedded in mortar. The outcomes of these tests have shown that both the temperature sensor and the pH sensor were able to function correctly for the duration of the work - for over 18 months after placement. The laboratory tests on the chloride sensor showed it was able to make measurements but was not reversible, limiting its potential utility for in situ environments. Research is ongoing to refine the sensor performance and extend the testing.
Resumo:
This paper could be consider seminal in the Civil Engineering field as it describes the first application of these sensors to a complex durability and management issue. For this reason it is potentially controversial as it requires Civil Engineers to re-evaluate the nature and scale of durability testing.
Resumo:
This paper describes the design, commissioning, and evaluation of a ?ber-optic strain sensor system for the structural health monitoring of a prestressed concrete posttensioned box girder railway bridge in Mumbai, India, which shows a number of well-documented structural problems. Preliminary laboratory trials to design the most appropriate sensor system that could be readily transported and used on site are described, followed by a description of load tests on the actual bridge undertaken in collaboration with Indian Railways and using locomotives of known weight. Results from the load tests using the optical system are compared with similar results obtained using electrical resistance strain gages. Conclusions are summarized concerning the integrity of the structure and for the future use of the sensor system for monitoring bridges of this type. Crack width measurements obtained during the load tests are also described.
Resumo:
This study evaluated the adverse effects of oral firocoxib in dogs. Six dogs (20.2 +/- 6.3 kg) were studied. Values for complete blood count (CBC), serum urea, creatinine, alanine transaminase, alanine phosphatase, -glutamyl transferase, occult blood in feces, platelet aggregation, and buccal mucosal bleeding time were measured before and 7, 14, 21, and 29 days after SID treatment with firocoxib 5.3 +/- 0.34 mg/kg (FG) or lactose 1 mg/kg (LG) for 2 8 days, in a randomized crossover study. Gastrointestinal (GI) tract endoscopy was performed before treatment began and at 29 days. Lesions were scored from grade 0 to 6. Data were analyzed using ANOVA and paired t-tests (P < 0.05). None of the dogs presented adverse clinical effects. There were no significant changes in CBC, biochemical profiles within groups, or differences between groups. Pretreatment mean SD bleeding time (LG, 70.7 +/- 32.1 sec; FG, 75.8 +/- 38.1 sec) and platelet aggregation (LG, 86.4 +/- 10.2%; FG, 85.6 +/- 9.2%) were not significantly different from readings at 29 days (LG, 95.2 +/- 25 sec; FG, 91.7 +/- 24 sec and LG, 73.2 +/- 15.1%; FG, 84 +/- 10.3%) nor the groups were different. None of the dogs had positive fecal occult blood tests, and endoscopic lesion scores were grade 0 both before treatment and at 29 days. Administration of firocoxib did not cause any adverse effects on GI, or hematological or serum biochemical variables and appears to have been well tolerated by dogs.
Resumo:
Objective: The aim of this study was to assess the existence of myofunctional alterations before and after first premolar extraction in Class II/1 malocclusion patients that could endanger the long-term dental arch stability. Materials and Methods: The study was performed by means of morphological, functional and electromyographic analyses in 17 Class II/1 malocclusion patients (group T) and 17 Class I malocclusion patients (group C), both groups with 12-30-year age range (mean age: 20.93 ± 4.94 years). Results: Data analyzed statistically by Student's t-test showed a significant decrease in the maxillary and mandibular dental arch perimeters after orthodontic treatment (p<0.05). The Kruskal-Wallis test analyzed data from tongue posture at rest and during swallowing, not showing significant differences after treatment (groups Tb and Ta) (p>0.05). However, group T differed significantly from group C (p<0.05). The electromyographic data showed that the anterior right and left suprahyoid muscles acted synergistically in both groups, while having a lower myoelectric activity in group T during swallowing. Conclusions: Myofunctional alterations observed after the orthodontic treatment in Class II/1 malocclusion seemed to jeopardize the long-term orthodontic stability, making recurrence possible. Further research should be conducted to compare electromyographic data before and after orthodontic treatment in order to corroborate the results of the present investigation.