855 resultados para Fetal heart rate monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis--University of Illinois at Urbana-Champaign.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a multiple initialization based spectral peak tracking (MISPT) technique for heart rate monitoring from photoplethysmography (PPG) signal. MISPT is applied on the PPG signal after removing the motion artifact using an adaptive noise cancellation filter. MISPT yields several estimates of the heart rate trajectory from the spectrogram of the denoised PPG signal which are finally combined using a novel measure called trajectory strength. Multiple initializations help in correcting erroneous heart rate trajectories unlike the typical SPT which uses only single initialization. Experiments on the PPG data from 12 subjects recorded during intensive physical exercise show that the MISPT based heart rate monitoring indeed yields a better heart rate estimate compared to the SPT with single initialization. On the 12 datasets MISPT results in an average absolute error of 1.11 BPM which is lower than 1.28 BPM obtained by the state-of-the-art online heart rate monitoring algorithm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We analyzed the effectiveness of linear short- and long-term variability time domain parameters, an index of sympatho-vagal balance (SDNN/RMSSD) and entropy in differentiating fetal heart rate patterns (fHRPs) on the fetal heart rate (fHR) series of 5, 3 and 2 min duration reconstructed from 46 fetal magnetocardiograms. Gestational age (GA) varied from 21 to 38 weeks. FHRPs were classified based on the fHR standard deviation. In sleep states, we observed that vagal influence increased with GA, and entropy significantly increased (decreased) with GA (SDNN/RMSSD), demonstrating that a prevalence of vagal activity with autonomous nervous system maturation may be associated with increased sleep state complexity. In active wakefulness, we observed a significant negative (positive) correlation of short-term (long-term) variability parameters with SDNN/RMSSD. ANOVA statistics demonstrated that long-term irregularity and standard deviation of normal-to-normal beat intervals (SDNN) best differentiated among fHRPs. Our results confirm that short-and long-term variability parameters are useful to differentiate between quiet and active states, and that entropy improves the characterization of sleep states. All measures differentiated fHRPs more effectively on very short HR series, as a result of the fMCG high temporal resolution and of the intrinsic timescales of the events that originate the different fHRPs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows: To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal wellbeing during labour, compared with no testing or alternative additional testing (pH, fetal pulse oximetry, etc) for women exhibiting a non-reassuring cardiotocograph trace. A secondary objective of the review is to determine whether effectiveness and risks of intrapartum fetal scalp lactate sampling is influenced by the following: stage of labour; gestation less than 37 completed weeks, greater than or equal to 37 completed weeks; additional tests performed to confirm the presence or absence of fetal acidemia during labour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current classification system for spinal cord injury (SCI) considers only somatic information and neglects autonomic damage after injiuy. Heart rate variability (HRV) has the potential to be a valuable measure of cardiac autonomic control after (SCI). Five individuals with tetraplegia and four able-bodied controls underwent 1 min continuous ECG recordings during rest, after Metoprolol administration (max dose=3x5mg) and after Atropine administration (0.02mg/kg) in both supine and 40° head-up tilt. After Metoprolol administration there was a 61.8% decrease in the LF:HF ratio in the SCI participants suggesting that the LF:HF ratio is a reflection of cardiac sympathetic outflow. After Atropine administration there was a 99.1% decrease in the HF power in the SCI participants suggesting that HF power is highly representative of cardiac parasympathetic outflow. There were no significant differences between the SCI and able-bodied participants. Thus, HRV measures are a valid index of cardiac autonomic control after SCI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: Después del ingreso de la monitoría fetal electrónica como estudio de bienestar fetal, se ha considerado por décadas que un aporte de carbohidratos a la gestante antes de la realización de la monitoría fetal influye en el reporte pero existen estudios que consideran que los niveles de glicemia materna no afecta la variabilidad de la monitoría fetal. Metodología: Se realizó un estudio de corte transversal, para evaluar el efecto de la glicemia materna en la monitoría fetal electrónica comparando los valores de glicemia materna con su resultado, según la categorización del ACOG. Las principales variables fueron las horas de ayuno, valores de glicemia, variabilidad de la monitoría fetal y presencia de aceleraciones. Resultados: Se incluyeron un total de 60 pacientes, que ingresaron al servicio de obstetricia y ginecología del Hospital Universitario Mayor Méderi en el periodo de estudio. No se encontraron diferencias estadísticamente significativas entre los resultados de monitoría fetal y los valores de glicemia materna. Ninguna paciente presentó monitoría categoría III (según categorización de la ACOG). Discusión Se requieren estudios analíticos más amplios para evaluar el papel de la glicemia en el resultado de la monitoría, pero el presente estudio sugiere que no existe relación entre la glicemia materna y el resultado de la monitoría fetal electrónica en la categorización del Colegio Americano De Ginecología Y Obstetricia (ACOG).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCCIÓN: El riesgo de padecer enfermedades cardiovasculares y los índices de obesidad infantil han ido en aumento durante los últimos años empobreciendo la salud de la población. La Teoría de Barker relaciona el estado de salud de la madre con el desarrollo fetal, asociando a un deficiente estado físico y hábitos de vida negativos de la mujer embarazada con el aumento del riesgo de padecer cardiopatías en la infancia y adolescencia, así como predisponer al recién nacido a padecer sobrepeso y/u obesidad en su vida posterior. Por otro lado los estudios efectuados sobre ejercicio físico durante el embarazo reportan beneficios para salud materna y fetal. Uno de los parámetros más utilizados para comprobar la salud fetal es su frecuencia cardiaca, mediante la que se comprueba el buen desarrollo del sistema nervioso autónomo. Si se observa este parámetro en presencia de ejercicio materno podría encontrarse una respuesta crónica del corazón fetal al ejercicio materno como consecuencia de una adaptación y mejora en el funcionamiento del sistema nervioso autónomo del feto. De esta forma podría mejorar su salud cardiovascular intrauterina, lo que podría mantenerse en su vida posterior descendiendo el riesgo de padecer enfermedades cardiovasculares en la edad adulta. OBJETIVOS: Conocer la influencia de un programa de ejercicio físico supervisado en la frecuencia cardiaca fetal (FCF) en reposo y después del ejercicio materno en relación con gestantes sedentarias mediante la realización de un protocolo específico. Conocer la influencia de un programa de ejercicio físico en el desarrollo del sistema nervioso autónomo fetal, relacionado con el tiempo de recuperación de la FCF. MATERIAL Y MÉTODO: Se diseñó un ensayo clínico aleatorizado multicéntrico en el que participaron 81 gestantes (GC=38, GE=43). El estudio fue aprobado por el comité ético de los hospitales que participaron en el estudio. Todas las gestantes fueron informadas y firmaron un consentimiento para su participación en el estudio. Las participantes del GE recibieron una intervención basada en un programa de ejercicio físico desarrollado durante la gestación (12-36 semanas de gestación) con una frecuencia de tres veces por semana. Todas las gestantes realizaron un protocolo de medida de la FCF entre las semanas 34-36 de gestación. Dicho protocolo consistía en dos test llevados a cabo caminando a diferentes intensidades (40% y 60% de la frecuencia cardiaca de reserva). De este protocolo se obtuvieron las principales variables de estudio: FCF en reposo, FCF posejercicio al 40 y al 60% de intensidad, tiempo de recuperación de la frecuencia cardiaca fetal en ambos esfuerzos. El material utilizado para la realización del protocolo fue un monitor de frecuencia cardiaca para controlar la frecuencia cardiaca de la gestante y un monitor fetal inalámbrico (telemetría fetal) para registrar el latido fetal durante todo el protocolo. RESULTADOS: No se encontraron diferencias estadísticamente significativas en la FCF en reposo entre grupos (GE=140,88 lat/min vs GC= 141,95 lat/min; p>,05). Se encontraron diferencias estadísticamente significativas en el tiempo de recuperación de la FCF entre los fetos de ambos grupos (GE=135,65 s vs GC=426,11 s esfuerzo al 40%; p<,001); (GE=180,26 s vs GC=565,61 s esfuerzo al 60%; p<,001). Se encontraron diferencias estadísticamente significativas en la FCF posejercicio al 40% (GE=139,93 lat/min vs GC=147,87 lat/min; p<,01). No se encontraron diferencias estadísticamente significativas en la FCF posejercicio al 60% (GE=143,74 lat/min vs GC=148,08 lat/min; p>,05). CONLUSIÓN: El programa de ejercicio físico desarrollado durante la gestación influyó sobre el corazón fetal de los fetos de las gestantes del GE en relación con el tiempo de recuperación de la FCF. Los resultados muestran un posible mejor funcionamiento del sistema nervioso autónomo en fetos de gestantes activas durante el embarazo. ABSTRACT INTRODUCTION: The risk to suffer cardiovascular diseases and childhood obesity index has grown in the last years worsening the health around the population. Barker´s Theory related maternal health with fetal development establishing an association between a poorly physical state and an unhealthy lifestyle in the pregnant woman with the risk to suffer heart disease during childhood and adolescence, childhood overweight and/or obese is related to maternal lifestyle. By the other way researches carried out about physical exercise and pregnancy show benefits in maternal and fetal health. One of the most studied parameters to check fetal health is its heart rate, correct fetal autonomic nervous system development and work is also corroborated by fetal heart rate. Looking at this parameter during maternal exercise a chronic response of fetal heart could be found due to an adaptation and improvement in the working of the autonomic nervous system. Therefore its cardiovascular health could be enhanced during its intrauterine life and maybe it could be maintained in its posterior life descending the risk to suffer cardiovascular diseases in adult life. OBJECTIVES: To know the influence of a supervised physical activity program in the fetal heart rate (FHR) at rest, FHR after maternal exercise related to sedentary pregnant women by a FHR assessment protocol. To know the influence of a physical activity program in the development of the autonomic nervous system related to FHR recovery time. MATERIAL AND METHOD: A multicentric randomized clinical trial was design in which 81 pregnant women participated (CG=38, EG=43). The study was approved by the ethics committee of all of the hospitals participating in the study. All of the participants signed an informed consent for their participation in the study. EG participants received an intervention based on a physical activity program carried out during gestation (12-36 gestation weeks) with a three days a week frequency. All of the participants were tested between 34-36 weeks of gestation by a specific FHR assessment protocol. The mentioned protocol consisted in two test performed walking and at a two different intensities (40% and 60% of the reserve heart rate). From this protocol we obtained the main research variables: FHR at rest, FHR post-exercise at 40% and 60% intensity, and FHR recovery time at both walking test. The material used to perform the protocol were a FH monitor to check maternal HR and a wireless fetal monitor (Telemetry) to register fetal beats during the whole protocol. RESULTS: There were no statistical differences in FHR at rest between groups (EG=140,88 beats/min vs CG= 141,95 beats/min; p>,05). There were statistical differences in FHR recovery time in both walking tests between groups (EG=135,65 s vs CG=426,11 s test at 40% intensity; p<,001); (EG=180,26 s vs CG=565,61 s test at 60% intensity; p<,001). Statistical differences were found in FHR post-exercise at 40% intensity between groups (EG=139,93 beats/min vs CG=147,87 beats/min; p<,01). No statistical differences were found in FHR at rest post-exercise at 60% intensity between groups (EG=143,74 beats/min vs CG=148,08 beats/min; p>,05). CONCLUSIONS: The physical activity program performed during gestation had an influence in fetal heart of the fetus from mother in the EG related to FHR recovery time. These results show a possible enhancement on autonomic nervous system working in fetus from active mothers during gestation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To establish whether fetal growth rate (as distinct from size at birth) is associated with mortality from ischaemic heart disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess and explain deviations from recommended practice in National Institute for Clinical Excellence (NICE) guidelines in relation to fetal heart monitoring. Design: Qualitative study. Setting: Large teaching hospital in the UK. Sample: Sixty-six hours of observation of 25 labours and interviews with 20 midwives of varying grades. Methods: Structured observations of labour and semistructured interviews with midwives. Interviews were undertaken using a prompt guide, audiotaped, and transcribed verbatim. Analysis was based on the constant comparative method, assisted by QSR N5 software. Main outcome measures: Deviations from recommended practice in relation to fetal monitoring and insights into why these occur. Results: All babies involved in the study were safely delivered, but 243 deviations from recommended practice in relation to NICE guidelines on fetal monitoring were identified, with the majority (80%) of these occurring in relation to documentation. Other deviations from recommended practice included indications for use of electronic fetal heart monitoring and conduct of fetal heart monitoring. There is evidence of difficulties with availability and maintenance of equipment, and some deficits in staff knowledge and skill. Differing orientations towards fetal monitoring were reported by midwives, which were likely to have impacts on practice. The initiation, management, and interpretation of fetal heart monitoring is complex and distributed across time, space, and professional boundaries, and practices in relation to fetal heart monitoring need to be understood within an organisational and social context. Conclusion: Some deviations from best practice guidelines may be rectified through straightforward interventions including improved systems for managing equipment and training. Other deviations from recommended practice need to be understood as the outcomes of complex processes that are likely to defy easy resolution. © RCOG 2006.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Today there is a growing interest in the integration of health monitoring applications in portable devices necessitating the development of methods that improve the energy efficiency of such systems. In this paper, we present a systematic approach that enables energy-quality trade-offs in spectral analysis systems for bio-signals, which are useful in monitoring various health conditions as those associated with the heart-rate. To enable such trade-offs, the processed signals are expressed initially in a basis in which significant components that carry most of the relevant information can be easily distinguished from the parts that influence the output to a lesser extent. Such a classification allows the pruning of operations associated with the less significant signal components leading to power savings with minor quality loss since only less useful parts are pruned under the given requirements. To exploit the attributes of the modified spectral analysis system, thresholding rules are determined and adopted at design- and run-time, allowing the static or dynamic pruning of less-useful operations based on the accuracy and energy requirements. The proposed algorithm is implemented on a typical sensor node simulator and results show up-to 82% energy savings when static pruning is combined with voltage and frequency scaling, compared to the conventional algorithm in which such trade-offs were not available. In addition, experiments with numerous cardiac samples of various patients show that such energy savings come with a 4.9% average accuracy loss, which does not affect the system detection capability of sinus-arrhythmia which was used as a test case. 

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke volume oscillations but not spectral frequency variability stroke volume measures can be used to estimate the breathing frequency. This study investigated with the same recordings whether heart period oscillations or spectral heart rate variability measures could function as estimators of breathing frequency. Continuous 270 s cardiovascular recordings were obtained from 22 healthy adult volunteers in the supine and upright postures. Breathing was recorded simultaneously. Breathing frequency and heart period oscillation frequency were calculated manually, while heart rate variability spectral maximums were obtained using heart rate variability software. These estimates were compared to the breathing frequency using the Bland–Altman agreement procedure. Estimates were required to be \±10% (95% levels of agreement). The 95% levels of agreement measures for the heart period oscillation frequency (supine: -27.7 to 52.0%, upright: -37.8 to 45.9%) and the heart rate variability spectral maximum estimates (supine: -48.7 to 26.5% and -56.4 to 62.7%, upright: -37.8 to 39.3%) exceeded 10%. Multiple heart period oscillations were observed to occur during breathing cycles. Both respiratory and non-respiratory sinus arrhythmia was observed amongst healthy adults. This observation at least partly explains why heart period parameters and heart rate variability parameters are not reliable estimators of breathing frequency. In determining the validity of spectral heart rate variability measurements we suggest that it is the position of the spectral peaks and not the breathing

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estudaram-se os efeitos do sevofluorano sobre a freqüência cardíaca nos fetos de cadelas no terço final de gestação, mediante a mensuração da freqüência cardíaca fetal com a utilização do ultra-som. Nove cadelas, sem raça definida, entre um e cinco anos de idade, com aproximadamente 45 dias de gestação, foram anestesiadas com acepromazina (0,05mg/kg, IV), propofol (5mg/kg, IV) e sevofluorano. O monitoramento da freqüência cardíaca fetal foi realizado antes da medicação pré-anestésica (M0), 15 minutos após a intubação traqueal (M1), aos 30 minutos (M2) e 60 minutos (M3) do período de manutenção anestésica. A pressão arterial sistólica (PAS), média (PAM) e diastólica (PAD) foram obtidas pelo método não invasivo, sendo a PAM avaliada também pelo método invasivo. Por meio do monitoramento da freqüência cardíaca fetal média não se observou diferença significativa entre M0, M1 e M2, e verificou-se elevação apenas aos 60 minutos da manutenção anestésica (M3) em relação ao M0, porém sem significado clínico. O protocolo anestésico provocou diminuição significativa da pressão sangüínea arterial materna sem alterar, porém a freqüência cardíaca dos fetos.