946 resultados para Femoral stem
Resumo:
The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10μm and the maximal micromotion was 60μm, in the loading direction, at 1400N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.
Resumo:
PURPOSE: The aim of this study was to determine outcomes of total hip replacement (THR) with the Lemania cemented femoral stem. METHODS: A total of 78 THR patients were followed and compared to 17 "fit", healthy, elderly and 72 "frail" elderly subjects without THR, using clinical outcome measures and a portable, in-field gait analysis device at five and ten years follow-up. RESULTS: Forty-one patients (53%), mean age 83.4 years, available at ten years follow-up, reported very good to excellent satisfaction. Mean Harris Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were 81.2 and 10.5 points, respectively, with excellent radiological preservation of proximal femur bone stock. Spatial and temporal gait parameters were close to the fit group and better than the frail group. CONCLUSIONS: Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR. Gait analysis confirmed good walking performance in a real-life environment.
Resumo:
In prosthesis, tribochemical reactions occur at the stem/bone interface. When coupled with micromotions it can lead to the loosening of the implant, osteolysis, release of metal ion and wear particles. The effect of these movements and the underlying mechanisms are quite unknown. This work investigates the tribocorrosion behavior of etched Ti6Al4V alloys under reciprocating sliding. Tests were performed in a phosphate buffer solution (PBS) containing proteins. A normal load of 1 N and anodic potentials of -0.1 and +0.5 V/SCE were applied. The destruction pathways of the top surface layers (adsorbed proteins, passive film) were studied. The results showed that the favorable/undesired effect of proteins in solution depends on the characteristics of the passive film under a mechanical stress. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVE: This study investigates by means of a new bone-prosthesis interface motion detector whether conceptual design differences of femoral stems are reflected in their primary stability pattern. DESIGN: An in vitro experiment using a biaxial materials testing machine in combination with three-dimensional motion measurement devices was performed. BACKGROUND: Primary stability of uncemented total hip replacements is considered to be a prerequisite for the quality of bony ongrowth to the femoral stem. Dynamic motion as a response to loading as well as total motion of the prosthesis have to be considered under quasi-physiological cyclic loading conditions. METHODS: Seven paired fresh cadaveric femora were used for the testing of two types of uncemented femoral stems with different anchoring concepts: CLS stem (Spotorno) and Cone Prosthesis (Wagner). Under sinusoidal cyclic loading mimicking in vivo hip joint forces a new measurement technique was applied allowing for the analysis of the three-dimensional interface motion. RESULTS: Considerable differences between the two prostheses could be detected both in their dynamic motion and total motion behaviour. Whereas the CLS stem, due to the wedge-shaped concept, provides smaller total motions, the longitudinal ribs of the Cone prostheses result in a substantially smaller dynamic motion. CONCLUSIONS: The measuring technique provided reliable and accurate data illustrating the three-dimensional interface motion of uncemented femoral stems.
Resumo:
INTRODUCTION: Periprosthetic femur fracture (PFF) is a serious complication after total hip arthroplasty that can be treated using different internal fixation devices. However, the outcomes with curved non-locking plates with eccentric holes in this indication have not been reported previously. The objectives of this study were to determine: (1) the union rate; (2) the complication rate; (3) autonomy in a group of patients with a Vancouver type B PFF who were treated with this plate. HYPOTHESIS: Use of this plate results in a high union rate with minimal mechanical complications. MATERIALS AND METHODS: Forty-three patients with a mean age of 79 years±13 (41-98) who had undergone fixation of Vancouver type B PFF with this plate between 2002 and 2007 were included in the study. The time to union and Parker Mobility Score were evaluated. The revision-free survival (all causes) was calculated using Kaplan-Meier analysis. The average follow-up was 42 months±20 (16-90). RESULTS: Union was obtained in all patients in a mean of 2.4 months±0.6 (2-4). One patient had varus malunion of the femur. The Parker Mobility Score decreased from 5.93±1.94 (2-9) to 4.93±1.8 (1-9) (P=0.01). Two patients required a surgical revision: one for an infection after 4.5 years and one for stem loosening. The survival of the femoral stem 5 years after fracture fixation was 83.3%±12.6%. CONCLUSION: Use of a curved plate with eccentric holes for treating type B PFF led to a high union rate and a low number of fixation-related complications. However, PFF remains a serious complication of hip arthroplasty that is accompanied by high morbidity and mortality rates. LEVEL OF EVIDENCE: Retrospective study, level IV.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
La artroplastia de cadera se considera uno de los mayores avances quirúrgicos de la Medicina. La aplicación de esta técnica de Traumatología se ha incrementado notablemente en los últimos anos, a causa principalmente del progresivo incremento de la esperanza de vida. En efecto, con la edad aumentan los problemas de artrosis y osteoporosis, enfermedades típicas de las articulaciones y de los huesos que requieren en muchos casos la sustitución protésica total o parcial de la articulación. El buen comportamiento funcional de una prótesis depende en gran medida de la estabilidad primaria, es decir, el correcto anclaje de la prótesis en el momento de su implantación. Las prótesis no cementadas basan su éxito a largo plazo en la osteointegración que tiene lugar entre el material protésico y el tejido óseo, y para lograrla es imprescindible conseguir unas buenas condiciones de estabilidad primaria. El aflojamiento aséptico es la principal causa de fallo de artroplastia total de cadera. Este es un fenómeno en el que, debido a complejas interacciones de factores mecánicos y biológicos, se producen movimientos relativos que comprometen la funcionalidad del implante. La minimización de los correspondientes danos depende en gran medida de la detección precoz del aflojamiento. Para lograr la detección temprana del aflojamiento aséptico del vástago femoral se han ensayado diferentes técnicas, tanto in vivo como in vitro: análisis numéricos y técnicas experimentales basadas en sensores de movimientos provocados por cargas transmitidas natural o artificialmente, tales como impactos o vibraciones de distintas frecuencias. Los montajes y procedimientos aplicados son heterogéneos y, en muchas ocasiones, complejos y costosos, no existiendo acuerdo sobre una técnica simple y eficaz de aplicación general. Asimismo, en la normativa vigente que regula las condiciones que debe cumplir una prótesis previamente a su comercialización, no hay ningún apartado referido específicamente a la evaluación de la bondad del diseño del vástago femoral con respecto a la estabilidad primaria. El objetivo de esta tesis es desarrollar una metodología para el análisis, in vitro, de la estabilidad de un vástago femoral implantado, a fin de poder evaluar las técnicas de implantación y los diferentes diseños de prótesis previamente a su oferta en el mercado. Además se plantea como requisito fundamental que el método desarrollado sea sencillo, reversible, repetible, no destructivo, con control riguroso de parámetros (condiciones de contorno de cargas y desplazamientos) y con un sistema de registro e interpretación de resultados rápido, fiable y asequible. Como paso previo, se ha realizado un análisis cualitativo del problema de contacto en la interfaz hueso-vástago aplicando una técnica optomecánica del campo continuo (fotoelasticidad). Para ello se han fabricado tres modelos en 2D del conjunto hueso-vástago, simulando tres tipos de contactos en la interfaz: contacto sin adherencia y con holgura, contacto sin adherencia y sin holgura, y contacto con adherencia y homogéneo. Aplicando la misma carga a cada modelo, y empleando la técnica de congelación de tensiones, se han visualizado los correspondientes estados tensionales, siendo estos más severos en el modelo de unión sin adherencia, como cabía esperar. En todo caso, los resultados son ilustrativos de la complejidad del problema de contacto y confirman la conveniencia y necesidad de la vía experimental para el estudio del problema. Seguidamente se ha planteado un ensayo dinámico de oscilaciones libres con instrumentación de sensores resistivos tipo galga extensométrica. Las muestras de ensayo han sido huesos fémur en todas sus posibles variantes: modelos simplificados, hueso sintético normalizado y hueso de cadáver, seco y fresco. Se ha diseñado un sistema de empotramiento del extremo distal de la muestra (fémur) con control riguroso de las condiciones de anclaje. La oscilación libre de la muestra se ha obtenido mediante la liberación instantánea de una carga estética determinada y aplicada previamente, bien con una maquina de ensayo o bien por gravedad. Cada muestra se ha instrumentado con galgas extensométricas convencionales cuya señal se ha registrado con un equipo dinámico comercial. Se ha aplicado un procedimiento de tratamiento de señal para acotar, filtrar y presentar las respuestas de los sensores en el dominio del tiempo y de la frecuencia. La interpretación de resultados es de tipo comparativo: se aplica el ensayo a una muestra de fémur Intacto que se toma de referencia, y a continuación se repite el ensayo sobre la misma muestra con una prótesis implantada; la comparación de resultados permite establecer conclusiones inmediatas sobre los efectos de la implantación de la prótesis. La implantación ha sido realizada por un cirujano traumatólogo utilizando las mismas técnicas e instrumental empleadas en el quirófano durante la práctica clínica real, y se ha trabajado con tres vástagos femorales comerciales. Con los resultados en el dominio del tiempo y de la frecuencia de las distintas aplicaciones se han establecido conclusiones sobre los siguientes aspectos: Viabilidad de los distintos tipos de muestras sintéticas: modelos simplificados y fémur sintético normalizado. Repetibilidad, linealidad y reversibilidad del ensayo. Congruencia de resultados con los valores teóricos deducidos de la teoría de oscilaciones libres de barras. Efectos de la implantación de tallos femorales en la amplitud de las oscilaciones, amortiguamiento y frecuencias de oscilación. Detección de armónicos asociados a la micromovilidad. La metodología se ha demostrado apta para ser incorporada a la normativa de prótesis, es de aplicación universal y abre vías para el análisis de la detección y caracterización de la micromovilidad de una prótesis frente a las cargas de servicio. ABSTRACT Total hip arthroplasty is considered as one of the greatest surgical advances in medicine. The application of this technique on Traumatology has increased significantly in recent years, mainly due to the progressive increase in life expectancy. In fact, advanced age increases osteoarthritis and osteoporosis problems, which are typical diseases of joints and bones, and in many cases require full or partial prosthetic replacement on the joint. Right functional behavior of prosthesis is highly dependent on the primary stability; this means it depends on the correct anchoring of the prosthesis at the time of implantation. Uncemented prosthesis base their long-term success on the quality of osseointegration that takes place between the prosthetic material and bone tissue, and to achieve this good primary stability conditions is mandatory. Aseptic loosening is the main cause of failure in total hip arthroplasty. This is a phenomenon in which relative movements occur, due to complex interactions of mechanical and biological factors, and these micromovements put the implant functionality at risk. To minimize possible damage, it greatly depends on the early detection of loosening. For this purpose, various techniques have been tested both in vivo and in vitro: numerical analysis and experimental techniques based on sensors for movements caused by naturally or artificially transmitted loads, such as impacts or vibrations at different frequencies. The assemblies and methods applied are heterogeneous and, in many cases, they are complex and expensive, with no agreement on the use of a simple and effective technique for general purposes. Likewise, in current regulations for governing the conditions to be fulfilled by the prosthesis before going to market, there is no specific section related to the evaluation of the femoral stem design in relation to primary stability. The aim of this thesis is to develop a in vitro methodology for analyzing the stability of an implanted femoral stem, in order to assess the implantation techniques and the different prosthesis designs prior to its offer in the market. We also propose as a fundamental requirement that the developed testing method should be simple, reversible, repeatable, non-destructive, with close monitoring of parameters (boundary conditions of loads and displacements) and with the availability of a register system to record and interpret results in a fast, reliable and affordable manner. As a preliminary step, we have performed a qualitative analysis of the contact problems in the bone-stem interface, through the application of a continuous field optomechanical technique (photoelasticity). For this proposal three 2D models of bone–stem set, has been built simulating three interface contact types: loosened an unbounded contact, unbounded and fixed contact, and bounded homogeneous contact. By means of applying the same load to each model, and using the stress freezing technique, it has displayed the corresponding stress states, being more severe as expected, in the unbounded union model. In any case, the results clearly show the complexity of the interface contact problem, and they confirm the need for experimental studies about this problem. Afterward a free oscillation dynamic test has been done using resistive strain gauge sensors. Test samples have been femur bones in all possible variants: simplified models, standardized synthetic bone, and dry and cool cadaveric bones. An embedding system at the distal end of the sample with strong control of the anchoring conditions has been designed. The free oscillation of the sample has been obtained by the instantaneous release of a static load, which was previously determined and applied to the sample through a testing machine or using the gravity force. Each sample was equipped with conventional strain gauges whose signal is registered with a marketed dynamic equipment. Then, it has applied a signal processing procedure to delimit, filter and present the time and frequency response signals from the sensors. Results are interpreted by comparing different trials: the test is applied to an intact femur sample which is taken as a reference, and then this test is repeated over the same sample with an implanted prosthesis. From comparison between results, immediate conclusions about the effects of the implantation of the prosthesis can be obtained. It must be said that the implementation has been made by an expert orthopedic surgeon using the same techniques and instruments as those used in clinical surgery. He has worked with three commercial femoral stems. From the results obtained in the time and frequency domains for the different applications the following conclusions have been established: Feasibility of the different types of synthetic samples: simplified models and standardized synthetic femur. Repeatability, linearity and reversibility of the testing method. Consistency of results with theoretical values deduced from the bars free oscillations theory. Effects of introduction of femoral stems in the amplitude, damping and frequencies of oscillations Detection of micromobility associated harmonics. This methodology has been proved suitable to be included in the standardization process of arthroplasty prosthesis, it is universally applicable and it allows establishing new methods for the analysis, detection and characterization of prosthesis micromobility due to functional loads.
Resumo:
PURPOSE: Evaluate the bone tissue recovery following transplantation of ovine mesenchymal stem cells (MSC) from bone marrow and human immature dental-pulp stem cells (hIDPSC) in ovine model of induced osteonecrosis of femoral head (ONFH). METHODS: Eight sheep were divided in three experimental groups. First group was composed by four animals with ONFH induced by ethanol through central decompression (CD), for control group without any treatment. The second and third group were compose by two animals, six weeks after ONFH induction received transplantation of heterologous ovine MSC (CD + oMSC), and hIDPSC (CD + hIDPSC), respectively. In both experiments the cells were transplanted without application of any type of immunosupression protocol. RESULTS: Our data indicate that both cell types used in experiments were able to proliferate within injured site providing bone tissue recovery. The histological results obtained from CD+hIDPSC suggested that the bone regeneration in such animals was better than that observed in CD animals. CONCLUSION: Mesenchymal stem cell transplant in induced ovine osteonecrosis of femoral head by central decompression technique is safe, and apparently favors bone regeneration of damaged tissues.
Resumo:
After cemented total hip arthroplasty (THA) there may be failure at either the cement-stem or the cement-bone interface. This results from the occurrence of abnormally high shear and compressive stresses within the cement and excessive relative micromovement. We therefore evaluated micromovement and stress at the cement-bone and cement-stem interfaces for a titanium and a chromium-cobalt stem. The behaviour of both implants was similar and no substantial differences were found in the size and distribution of micromovement on either interface with respect to the stiffness of the stem. Micromovement was minimal with a cement mantle 3 to 4 mm thick but then increased with greater thickness of the cement. Abnormally high micromovement occurred when the cement was thinner than 2 mm and the stem was made of titanium. The relative decrease in surface roughness augmented slipping but decreased debonding at the cement-bone interface. Shear stress at this site did not vary significantly for the different coefficients of cement-bone friction while compressive and hoop stresses within the cement increased slightly.
Resumo:
We prospectively evaluated the results of our custom cementless femoral stems to ascertain whether this technology produced reasonable clinical function, complication rates, and loosening rates at midterm. Fifty-seven consecutive patients had surgery in 62 hips for primary osteoarthritis at a mean age of 57 years using a three-dimensional computed custom cementless stem. Patients were reviewed at a mean followup of 94.9 months. At review, the mean Harris hip score was 98.8 points (range, 84-100) compared with 61.1 (range, 28-78) points preoperatively. No patient complained of thigh pain. No migration or subsidence was observed. All stems were considered stable according to the radiographic criteria defined by Engh et al. There were no dislocations, no infections, and no reoperations. Our results are comparable with published results from clinical and radiologic points of view. Two problems remain unsolved: the price of a custom stem is twice as expensive as a standard stem; and we need longer term results before definitely recommending this technology as a reasonable alternative to current arthroplasties in younger patients. The data support the continued exploration of this technology with controlled clinical followup. LEVEL OF EVIDENCE: Therapeutic study, Level II-1 (prospective cohort study). See the Guidelines to Authors for a complete description of levels of evidence.
Resumo:
BACKGROUND: The literature suggests that intraoperative fractures of the greater trochanter and the metaphysis are increased with uncemented stems and the direct anterior approach. This study aims to determine the incidence and assess the functional and radiological outcome after such fractures. METHODS: 484 consecutive total hip replacements (THR) (64 ± 12 years) were analyzed. We treated trochanteric fractures conservatively without any further denuding, and secured metaphyseal fissures with cerclages. Postoperative X-rays and at the latest follow-up were compared to assess secondary fracture displacement and stem subsidence. Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores after 1 year were analyzed. For each patient sustaining a fracture, two patients without fractures were matched in terms of age, body mass index and gender. RESULTS: 13 (2.7 %, 5 male, 68 ± 9 years) patients with intraoperative fractures of the greater trochanter (n = 8) or the metaphysis (n = 5) were analyzed. Consolidation was observed in 7/8 patients sustaining a trochanteric fracture while secondary displacement of the fragment occurred in one case. Stem subsidence was observed in 2/5 cases (5 and 7 mm). Patients who sustained a fracture showed a trend towards poorer WOMAC scores at 1 year postoperatively, compared to patients without fractures. A significantly increased joint stiffness was also observed. CONCLUSION: The intraoperative fracture risk in this series of THR through a direct anterior approach was 2.7 %. Trochanteric fractures do heal without primary fixation. Metaphyseal fractures heal well if immediately stabilized with a cerclage.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
BACKGROUND: We hypothesized that certain patient characteristics have different effects on the risk of early stem loosening in total hip arthroplasty (THA). We therefore conducted a case-control study using register-database records with the aim of identifying patient-specific risk factors associated with radiographic signs of aseptic loosening of the femoral component in THA. METHOD: Data were derived from a multinational European registry and were collected over a period of 25 years. 725 cases with radiographic signs of stem loosening were identified and matched to 4,310 controls without any signs of loosening. Matching criteria were type of implant, size of head, date of operation, center of primary intervention, and follow-up time. The risk factors analyzed were age at operation, sex, diagnosis and previous ipsilateral operations, height, weight, body mass index and mobility based on the Charnley classification. RESULTS: Women showed significantly lower risk of radiographic loosening than men (odds ratio (OR) 0.64). Age was also a strong factor: risk decreased by 1.8% for each additional year of age at the time of surgery. Height and weight were not associated with risk of loosening. A higher body mass index, however, increased the risk of stem loosening to a significant extent (OR 1.03) per additional unit of BMI. Charnley Class B, indicating restricted mobility, was associated with lower risk of loosening (OR 0.78). INTERPRETATION: An increased activity level, as seen in younger patients and those with unrestricted mobility, is an important factor in the etiology of stem loosening. If combined with high BMI, the risk of stem loosening within 10 years is even higher. A younger person should not be denied the benefits of a total hip arthroplasty but must accept that the risk of future failure is increased.