935 resultados para Faria, Almeida, 1943-


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recursos Educativos

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The matching of the aesthetic, functional, and psychosocial results of a facial deformity may produce devastating effects in its carriers, especially if the lesion is extensive or the treatment is aggressive. Because of this, the objective of the present article was to evaluate patient's satisfaction rating after surgical facial reconstruction or rehabilitation with oral and maxillofacial prosthesis, by means of reviewing the literature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the frequency of removable partial dentures (RPD) at the Aracatuba Dental School.Methods: The study was conducted by analysing 412 clinical history of patients attended at the RPD clinics in the period from 2000 to 2007.Results: 412 charts were analysed: 148 (35.9%) men and 264 (64.1%) women. The mean age was 53.8 years (men) and 52.4 years (women). A total of 556 dentures were made; of these, 233 (41.90%) were maxillary and 323 (58.09%) were mandibular dentures. The most frequent Kennedy classification found was Class III (maxilla) and Class I (mandible). In the maxilla, 55% (126) of the major connectors were of the anterior-posterior palatal bar, while in the mandible, 64% (202) were the lingual bar. As regards the claps, 401 were circumferential and 318 were bar claps.Conclusion: The mean age of the patients was 52.9 years with higher prevalence of female patients; the most frequent Kennedy's classification was Class I in mandible and Class III in maxilla; the most common major connector was anterior-posterior palatal bar for maxilla and lingual bar for mandible; the circumferential clasps were the most common retainer used in both jaws.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

It is known that several factors can affect the clinical success and durability of fixed partial dentures. Therefore, the aim of the present study was to present a literature review about the longevity, clinical success, and quality, as well as, patients' and dental surgeons' satisfaction of ceramic fixed dentures. High rate of patients' satisfaction has been observed in relation to the esthetic of ceramic crowns. In addition, the literature has shown that dental ceramics can be used in several clinical situations with high success rate and longevity. Despite of failures and complications of ceramic restorations, nowadays, with the improvement of mechanical properties of such materials, ceramic crowns present a favorable prognosis and can be used in several clinical situations with high success rate, clinical quality, and great patients' satisfaction. © 2013 The American Ceramic Society.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The purpose of this study is to analyze the tension distribution on bone tissue around implants with different angulations (0 degrees, 17 degrees, and 30 degrees) and connections (external hexagon and tapered) through the use of three-dimensional finite element and statistical analyses.Methods: Twelve different configurations of three-dimensional finite element models, including three inclinations of the implants (0 degrees, 17 degrees, and 30 degrees), two connections (an external hexagon and a tapered), and two load applications (axial and oblique), were simulated. The maximum principal stress values for cortical bone were measured at the mesial, distal, buccal, and lingual regions around the implant for each analyzed situation, totaling 48 groups. Loads of 200 and 100 N were applied at the occlusal surface in the axial and oblique directions, respectively. Maximum principal stress values were measured at the bone crest and statistically analyzed using analysis of variance. Stress patterns in the bone tissue around the implant were analyzed qualitatively.Results: The results demonstrated that under the oblique loading process, the external hexagon connection showed significantly higher stress concentrations in the bone tissue (P < 0.05) compared with the tapered connection. Moreover, the buccal and mesial regions of the cortical bone concentrated significantly higher stress (P < 0.005) to the external hexagon implant type. Under the oblique loading direction, the increased external hexagon implant angulation induced a significantly higher stress concentration (P = 0.045).Conclusions: The study results show that: 1) the oblique load was more damaging to bone tissue, mainly when associated with external hexagon implants; and 2) there was a higher stress concentration on the buccal region in comparison to all other regions under oblique load.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects that splinting and different lengths of implants have on the stress distribution in implant-supported prostheses by photoelastic analysis. A total of five photoelastic resin models were made with different proposed situations, and 400 load applications were performed for the analysis. Compared with the unitary prosthesis, the splinted implant-supported prosthesis acted favorably in the distribution of stresses and strains to the implant (p < 0.001). The increase in length was a significant factor in the stress distribution (p < 0.05) and, ultimately, the overall reduction in stress. It was concluded that the splinted implant-supported prosthesis behaved better biomechanically compared with the unitary prosthesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of this systematic review was to compare straight-line and offset implant configurations for three-element implant-retained prostheses. Materials and Methods: Two independent reviewers conducted a review on PubMed/Medline, EMBASE, and Cochrane Library for studies published in English, from January 1, 1995 to January 17, 2014. A systematic review was conducted following the PRISMA statement. All relevant titles were selected according to inclusion/exclusion criteria. From this pool of titles, abstracts and full texts were reviewed. Results: A total of 6080 titles were identified with the initial search. Twenty-one were selected based on title and abstract. Of these, after discussion and complete reading, 12 studies were selected according to the inclusion and exclusion criteria, all of which were in vitro studies. Conclusions: A systematic review of the current literature showed only in vitro evidence that there is no consensus on the advantage of using an offset configuration implant compared to those in straight-line configuration, even though some studies present a slight improvement of bone stress distribution when an offset implant is under oblique loading (PICO).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10,12.5, 15 mm crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-Dmodels. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metalceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200 N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises'criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maxiinum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio = 30.1% and C/I 1:1 to 1 :1.5 ratio = 46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio = 30% and C/I 1:1 to 1:1.5 ratio = 51.5%). (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Complete denture fabrication can be a treatment challenge for many dentists, especially when the patient has remaining teeth. So, planning for use of clinical alternatives to improve the treatment prognosis and to enable greater comfort to patient must be considered. This case report describes the use of remaining roots to aid in the stability, support and retention of root-supported overdentures. Thus, immediate prostheses were planned for temporary rehabilitation prior to definitive overdentures. The aim of this study was to demonstrate the planning of root-supported overdentures attached with a ball system for retention associated with immediate dentures between the periods of preparation to fabrication of the definitive overdentures. The proposed treatment met the patient's needs such as being able to carry on normal activities during the sequencing of procedures to be performed over a period of time. The treatment had longevity with patient's knowledge about the necessity of oral hygiene and periodic controls.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to analyze the stress distribution of short implants supporting single unit or splinted crowns by the photo-elasticity method. Four photo-elastic models were produced: A (3.75×7mm); B (3.75×7mm, 3.75×7mm and 3.75×7mm); C (3.75×10mm, 3.75×7mm and 3.75×7mm); D (3.75×13mm, 3.75×7mm and 3.75×7mm). The prostheses were made with Ni-Cr alloy. A load of 100N in the axial and oblique directions was applied, totaling 380 applications, individually capturing their images in each model. The data were randomized and analyzed qualitatively and quantitatively by 2 examiners. The oblique loading was significantly more damaging. The increase in length was favorable for stress distribution (p<0.05). The splinting was beneficial for the transmission of stresses mainly (p<0.05). The splinting of the crowns, as well as increasing the length of the first implant and axial loading was most beneficial in the stress distribution. Short splinted implants behaved better than single unit implants. Increasing of the length of the first implant significantly improved the stress distribution in all analyzed situations.