268 resultados para Fabry–Pérot interferometer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development and fabrication of a thermo-electro-optic sensor using a Mach-Zehnder interferometer and a resistive micro-heater placed in one of the device`s arms is presented. The Mach-Zehnder structure was fabricated on a single crystal silicon substrate using silicon oxynitride and amorphous hydrogenated silicon carbide films to form an anti-resonant reflective optical waveguide. The materials were deposited by Plasma enhanced chemical vapor deposition technique at low temperatures (similar to 320 degrees C). To optimize the heat transfer and increase the device response with current variation, part of the Mach-Zehnder sensor arm was suspended through front-side bulk micromachining of the silicon substrate in a KOH solution. With the temperature variation caused by the micro-heater, the refractive index of the core layer of the optical waveguide changes due to the thermo-optic effect. Since this variation occurs only in one of the Mach-Zehnder`s arm, a phase difference between the arms is produced, leading to electromagnetic interference. In this way, the current applied to the micro-resistor can control the device output optical power. Further, reactive ion etching technique was used in this work to define the device`s geometry, and a study of SF6 based etching rates on different composition of silicon oxynitride films is also presented. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A versatile miniature de Broglie waveguide is formed by two parallel current-carrying wires in the presence of a uniform bias field. We derive a variety of analytical expressions to describe the guide and present a quantum theory to show that it offers a remarkable range of possibilities for atom manipulation on the submicron scale. These include controlled and coherent splitting of the wave function as well as cooling, trapping, and guiding. In particular, we discuss a novel microscopic atom interferometer with the potential to be exceedingly sensitive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a simple method to obtain surface gratings using a Michelson interferometer and femtosecond laser radiation. In the optical setup used, two parallel laser beams are generated using a beam splitter and then focused using the same focusing lens. An interference pattern is created in the focal plane of the focusing lens, which can be used to pattern the surface of materials. The main advantage of this method is that the optical paths difference of the interfering beams is independent of the distance between the beams. As a result, the fringes period can be varied without a need for major realignment of the optical system and the time coincidence between the interfering beams can be easily monitored. The potential of the method was demonstrated by patterning surface gratings with different periods on titanium surfaces in air.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interferometer for low resolution portable Fourier Transform middle infrared spectrometer was developed and studied experimentally. The final aim was a concept for a commercial prototype. Because of the portability, the interferometer should be compact sized and insensitive to the external temperature variations and mechanical vibrations. To minimise the size and manufacturing costs, Michelson interferometer based on plane mirrors and porch swing bearing was selected and no dynamic alignment system was applied. The driving motor was a linear voice coil actuator to avoid mechanical contact of the moving parts. The driving capability for low mirror driving velocities required by the photoacoustic detectors was studied. In total, four versions of such an interferometer were built and experimentally studied. The thermal stability during the external temperature variations and the alignment stability over the mirror travel were measured using the modulation depth of the wide diameter laser beam. Method for estimating the mirror tilt angle from the modulation depth was developed to take account the effect from the non-uniform intensity distribution of the laser beam. The spectrometer stability was finally studied also using the infrared radiation. The latest interferometer was assembled for the middle infrared spectrometer with spectral range from 750 cm−1 to 4500 cm−1. The interferometer size was (197 × 95 × 79) mm3 with the beam diameter of 25 mm. The alignment stability as the change of the tilt angle over the mirror travel of 3 mm was 5 μrad, which decreases the modulation depth only about 0.7 percent in infrared at 3000 cm−1. During the temperature raise, the modulation depth at 3000 cm−1 changed about 1 . . . 2 percentage units per Celsius over short term and even less than 0.2 percentage units per Celsius over the total temperature raise of 30 °C. The unapodised spectral resolution was 4 cm−1 limited by the aperture size. The best achieved signal to noise ratio was about 38 000:1 with commercially available DLaTGS detector. Although the vibration sensitivity requires still improving, the interferometer performed, as a whole, very well and could be further developed to conform all the requirements of the portable and stable spectrometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel optical add-drop multiplexer (OADM) based on the Mach-Zelauler interferometer (MZI) and the fiber Bragg grating (FBG) is proposed for the first tittle to the authors ' knowledge. In the structure, the Mach-Zehnder interferometer acts as an optical switch. The principle of the OADM is analyzed in this paper. The OADM can add/drop one of the multi-input channels or pass the channel directly by adjusting the difference of the two arms of the interferometer. The channel isolation is more than 20 dB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The link between natural ion-line enhancements in radar spectra and auroral activity has been the subject of recent studies but conclusions have been limited by the spatial and temporal resolution previously available. The next challenge is to use shorter sub-second integration times in combination with interferometric programmes to resolve spatial structure within the main radar beam, and so relate enhanced filaments to individual auroral rays. This paper presents initial studies of a technique, using optical and spectral satellite signatures, to calibrate the received phase of a signal with the position of the scattering source along the interferometric baseline of the EISCAT Svalbard Radar. It is shown that a consistent relationship can be found only if the satellite passage through the phase fringes is adjusted from the passage predicted by optical tracking. This required adjustment is interpreted as being due to the vector between the theoretical focusing points of the two antennae, i.e. the true radar baseline, differing from the baseline obtained by survey between the antenna foot points. A method to obtain a measurement of the true interferometric baseline using multiple satellite passes is outlined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Sagnac effect is an important phase coherent effect in optical and atom interferometers where rotations of the interferometer with respect to an inertial reference frame result in a shift in the interference pattern proportional to the rotation rate. Here, we analyze the Sagnac effect in a mesoscopic semiconductor electron interferometer. We include in our analysis the Rashba spin-orbit interactions in the ring. Our results indicate that spin-orbit interactions increase the rotation-induced phase shift. We discuss the potential experimental observability of the Sagnac phase shift in such mesoscopic systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synthetic-heterodyne demodulation is a useful technique for dynamic displacement and velocity detection in interferometric sensors, as it can provide an output signal that is immune to interferometric drift. With the advent of cost-effective, high-speed real-time signal-processing systems and software, processing of the complex signals encountered in interferometry has become more feasible. In synthetic heterodyne, to obtain the actual dynamic displacement or vibration of the object under test requires knowledge of the interferometer visibility and also the argument of two Bessel functions. In this paper, a method is described for determining the former and setting the Bessel function argument to a set value, which ensures maximum sensitivity. Conventional synthetic-heterodyne demodulation requires the use of two in-phase local oscillators; however, the relative phase of these oscillators relative to the interferometric signal is unknown. It is shown that, by using two additional quadrature local oscillators, a demodulated signal can be obtained that is independent of this phase difference. The experimental interferometer is aMichelson configuration using a visible single-mode laser, whose current is sinusoidally modulated at a frequency of 20 kHz. The detected interferometer output is acquired using a 250 kHz analog-to-digital converter and processed in real time. The system is used to measure the displacement sensitivity frequency response and linearity of a piezoelectric mirror shifter over a range of 500 Hz to 10 kHz. The experimental results show good agreement with two data-obtained independent techniques: the signal coincidence and denominated n-commuted Pernick method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piezoelectric transducers are widely used in high-resolution positioning systems. This paper reports the experimental analysis of a novel piezoelectric flextensional actuator (PFA), which is designed by using the topology-optimization method through a low-cost homodyne Michelson interferometer. By applying the J(1) - J(4) method for signal demodulation, which provides a linear and direct measurement of dynamic optical phase shift independent of fading, the nanometric displacements of the PFA were determined. Linearity and frequency response of the PFA were evaluated up to 50 kHz. PFA calibration factor and amplification rate were determined for the PFA operating in the quasi-static regime. To confirm the observed frequencies of resonance, an impedance analyzer is also utilized to measure the magnitude and phase of the PFA admittance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract (deutsch)Zielsetzung des Dissertationsvorhabens war die Beobachtung und Analyse von Gast-Wirt-Wechselwirkungen an oxidischen Oberflächen. Einer der Wechselwirkungspartner sollte dabei auf der Oberfläche immobilisiert, der andere in wäßriger Lösung darüber vorliegen.Eine empfindliche und oberflächensensitive Methode zur Beobachtung der Anlagerung unmarkierter Moleküle ist die Wellenleiterspektroskopie, insbesondere mit dem hier verwendeten und weiterentwickelten integriert-optischen Mach-Zehnder-Interferometer in Siliziumtechnik (Siliziumoxynitrid auf oxidiertem Siliziumwafer). Mit Hilfe des Interferometers wurden unterschiedliche Wirt-Gast-Systeme untersucht. Grundlage der Immobilisierung war jeweils die Funktionalisierung der Sensoroberfläche durch Selbstadsorption von Organosilanen. Durch unterschiedliche Organosilane, die zum Teil im Rahmen dieser Arbeit synthetisiert wurden, ließen sich die Wirtmoleküle beta-Cyclodextrin, Streptavidin, sowie unterschiedliche monoklonale Antikörperfragmente immobilisieren.- Der Einfluß der Oberfläche auf die Bindungsstärke des Wirtmoleküls beta-Cyclodextrin und unterschiedlicher Gastmoleküle wurde konzentrationsabhängig untersucht.- Silan-Biotinderivate mit unterschiedlicher Streptavidin-Affinität wurden an die Oberfläche immobilisiert und die Adsorption von Streptavidin an die Biotinderivate beobachtet. Dabei konnte unter anderem nachgewiesen werden, daß das Streptavidinadsorbat gequollen ist.- Als mögliche Anwendung wurde geprüft, ob das vorgestellte Interferometer durch die Funktionalisierung mit Antikörperfragmenten als Biosensor in Frage kommt. Es konnte nachgewiesen werden, daß sich Antikörper auf der Sensoroberfläche immobilisieren lassen und Antigene spezifisch an diese Antikörper adsorbieren.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Am Mainzer Mikrotron MAMI wurde ein neuartiges Interferometer entwickelt und getestet, mit dem magneto-optische Effekte an dünnen, freitragenden Folien von 3d-Übergangsmetallen wie Eisen, Kobalt oder Nickel an den L_{2,3}-Absorptionskanten (im Spektralbereich der weichen Röntgenstrahlung) gemessen werden können. Es handelt sich um eine Weiterentwicklung eines an MAMI erprobten Interferometers, das im wesentlichen aus einer kollinearen Anordnung zweier identischer Undulatoren, zwischen die die dünne Probefolie eingebracht wird, und einem Gitterspektrometer besteht. Aus den als Funktion des Abstands der Undulatoren beobachtbaren Intensitätsoszillation lassen sich das Dekrement des Realteils δ und der Absorptionskoeffizient β des komplexen Brechungsindex bestimmen.rnIm Rahmen der vorliegenden Arbeit wurde die Apparatur derart weiterentwickelt, dass auch die magnetisch zirkulare Doppelbrechung Δδ und der magnetisch zirkulare Dichroismus Δβ an den L_{2,3}-Absorptionskanten von Übergangsmetallen gemessen werden können. Der zweite Undulator wurde um die Elektronenstrahlachse um den Winkel Ψ = ±107° drehbar gemacht. Damit dient er auch als Analysator der aus der Folie austretenden elliptisch polarisierten weichen Röntgenstrahlung, für die - wie bei der Faraday-Rotation - die Polarisationsebene gedreht ist. Weiterhin kann die Spaltbreite der 10-poligen Hybrid-Undulatoren mit einer Periodenlänge von 12 mm und damit der Undulatorparameter über eine Antriebsmechanik kontinuierlich variiert werden, wodurch eine optimale Anpassung der Amplituden der Undulatorstrahlung aus den beiden Undulatoren möglich wird. Der maximale Undulatorparameter beträgt K = 1.1. Auch das Spektrometer, das auf einem selbstfokussierenden Gitter mit variierter Liniendichte (im Mittel 1400 Linien / mm) basiert, wurde weiterentwickelt. Als Detektor kommt jetzt eine fensterlose CCD mit 1024 x 1024 Pixeln und einer Pixelgröße von 13 μm x 13 μm zum Einsatz, die im Bildmodus betrieben wird, was die gleichzeitige Messung eines Energieintervalls von ca. 50 eV ermöglicht. Die totale Linienbreite wurde bei einer vertikalen Strahlfleckausdehnung von σ_y = 70 μm (rms) am Neon 1s-3p Übergang bei (867.18 ±0.02) eV zu Δħω = (0.218 ±0.002) eV (FWHM) gemessen. Das hohe Auflösungsvermögen von 4000 und die Möglichkeit der Eichung gegen den 1s-3p Übergang von Neon wurden ausgenutzt, um die Energie der Maxima an den Absorptionskanten von Nickel (weiße Linien) neu zu bestimmen. Die Ergebnisse E_{L_2}=(869.65_{-0.16}^{+0.27}) eV und E_{L_3}=(852.37_{-0.11}^{+0.16}) eV stellen eine Verbesserung früherer Messungen dar, die große Streuungen aufwiesen.rnAus systematischen Messungen als Funktion des Abstandes der Undulatoren und des Drehwinkels Ψ wurden die magnetisch zirkulare Doppelbrechung Δδ im Energiebereich 834 eV ≤ ħω ≤ 885 eV an einer freitragenden, bis zur Sättigung magnetisierten Nickelfolie der Dicke von (96.4 ±2.7) nm gemessen. Sowohl das Auflösungsvermögen als auch die Genauigkeit der Messungen für Δδ übersteigen bekannte Literaturangaben signifikant, so dass eine bisher nicht bekannte Feinstruktur gefunden werden konnte. Außerdem wurde der Betrag des magnetisch zirkularen Dichroismus |Δβ| im Bereich des Maximums an der L_3-Absorptionskante mit hoher Genauigkeit gemessen.rn