145 resultados para FLUOROSCOPY
Resumo:
We have shown how the analysis of the angiotomography reconstruction through OsiriX program has assisted in endovascular perioperative programming. We presented its application in situations when an unexpected existence of metallic overlapping artifact (orthopedic osteosynthesis) compromised the adequate visualization of the arterial lesion during the procedure. Through manipulation upon OsiriX software, with assistance of preview under virtual fluoroscopy, it was possible to obtain the angles that would avoid this juxtaposition. These angles were reproduced in the C-arm, allowing visualization of the occluded segment, reducing the need for repeated image acquisitions and contrast overload, allowing the continuation of the procedure.
Resumo:
Background/Purpose: Central venous catheterization is among the most common procedures performed by pediatric surgeons. Significant morbidity and even mortality can ensue from the widespread approach to the deep veins of the neck and femoral region. The external jugular vein (EJV) is a low-morbidity alternative for percutaneous catheterization in children, but it has yielded a low success rate in previous reports The authors show an improved success rate with this option. Methods: We performed an analysis of 33 patients` charts in which central venous catheterization using Seldinger technique through the EJV was attempted in 2005. Age, diagnosis, maneuvers used for success, fluoroscopy usefulness, and types of inserted catheters were evaluated. Results: The procedure was successful in 26 (78.8%) patients without complications. Diagnosis was neoplasia in almost half of the patients (42%). In half of the successful cases, body maneuvers were used, namely, twisting the head of the patient to the side of the vein and stretching the ipsilateral arm and shoulder. All but one procedure were completed under fluoroscopic guidance. In 6 (23%) patients, a long-term catheter was inserted. Conclusions: The EJV is an excellent option for central venous catheterization in children. The execution of simple maneuvers along with fluoroscopic assistance might allow for an improved success rate not only for short-term but also for long-term catheter insertion. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.
Resumo:
A nationwide survey was launched to investigate the use of fluoroscopy and establish national reference levels (RL) for dose-intensive procedures. The 2-year investigation covered five radiology and nine cardiology departments in public hospitals and private clinics, and focused on 12 examination types: 6 diagnostic and 6 interventional. A total of 1,000 examinations was registered. Information including the fluoroscopy time (T), the number of frames (N) and the dose-area product (DAP) was provided. The data set was used to establish the distributions of T, N and the DAP and the associated RL values. The examinations were pooled to improve the statistics. A wide variation in dose and image quality in fixed geometry was observed. As an example, the skin dose rate for abdominal examinations varied in the range of 10 to 45 mGy/min for comparable image quality. A wide variability was found for several types of examinations, mainly complex ones. DAP RLs of 210, 125, 80, 240, 440 and 110 Gy cm2 were established for lower limb and iliac angiography, cerebral angiography, coronary angiography, biliary drainage and stenting, cerebral embolization and PTCA, respectively. The RL values established are compared to the data published in the literature.
Resumo:
Bone-mounted robotic guidance for pedicle screw placement has been recently introduced, aiming at increasing accuracy. The aim of this prospective study was to compare this novel approach with the conventional fluoroscopy assisted freehand technique (not the two- or three-dimensional fluoroscopy-based navigation). Two groups were compared: 11 patients, constituting the robotical group, were instrumented with 64 pedicle screws; 23 other patients, constituting the fluoroscopic group, were also instrumented with 64 pedicle screws. Screw position was assessed by two independent observers on postoperative CT-scans using the Rampersaud A to D classification. No neurological complications were noted. Grade A (totally within pedicle margins) accounted for 79% of the screws in the robotically assisted and for 83% of the screws in the fluoroscopic group respectively (p = 0.8). Grade C and D screws, considered as misplacements, accounted for 4.7% of all robotically inserted screws and 7.8% of the fluoroscopically inserted screws (p = 0.71). The current study did not allow to state that robotically assisted screw placement supersedes the conventional fluoroscopy assisted technique, although the literature is more optimistic about the former.
Resumo:
Purpose: To set local dose reference levels (DRL) that allow radiologists to control stochastic and deterministic effects. Methods and materials: Dose indicators for cerebral angiographies and hepatic embolizations were collected during 4 months and analyzed in our hospital. The data were compared when an image amplifier was used instead of a flat panel detector. The Mann and Whitney test was used. Results: For the 40 cerebral angiographies performed the DRL for DAP, fluoroscopy time and number of images were respectively: 166 Gy.cm2, 19 min, 600. The maximum DAP was 490 Gy.cm2 (fluoroscopy time: 84 min). No significant difference for fluoroscopy time and DAP for image amplifier and flat panel detector (p = 0.88) was observed. The number of images was larger for flat panel detector (p = 0.004). The values obtained were slightly over the present proposed DRL: 150 Gy.cm2, 15 min, 400. Concerning the 13 hepatic embolizations the DRL for DAP fluoroscopy time and number of images were: 315 Gy.cm2, 25 min, 370. The maximum DAP delivered was 845 Gy.cm2 (fluoroscopy time of 48 min). No significant difference between image amplifier and flat panel detector was observed (p = 0.005). The values obtained were also slightly over the present proposed DRL: 300 Gy.cm2, 20 min, 200. Conclusion: These results show that the introduction of flat panel detector did not lead to an increase in patient dose. A DRL concerning the cumulative dose (that allow to control the deterministic effect) should be introduced to allow radiologists to have full control on the risks associated with ionizing radiations. Results of this on going study will be presented.
Resumo:
PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.
Resumo:
Object Recent years have been marked by efforts to improve the quality and safety of pedicle screw placement in spinal instrumentation. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement. Methods Ninety-five patients suffering from degenerative disease and requiring elective lumbar instrumentation were included in the study. The robot cohort (Group I; 55 patients, 244 screws) consisted of an initial open robot-assisted subgroup (Subgroup IA; 17 patients, 83 screws) and a percutaneous cohort (Subgroup IB, 38 patients, 161 screws). In these groups, pedicle screws were placed under robotic guidance and lateral fluoroscopic control. In the fluoroscopy-guided cohort (Group II; 40 patients, 163 screws) screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. The primary outcome measure was accuracy of screw placement on the Gertzbein-Robbins scale (Grade A to E and R [revised]). Secondary parameters were duration of surgery, blood loss, cumulative morphine, and length of stay. Results In the robot group (Group I), a perfect trajectory (A) was observed in 204 screws (83.6%). The remaining screws were graded B (n = 19 [7.8%]), C (n = 9 [3.7%]), D (n = 4 [1.6%]), E (n = 2 [0.8%]), and R (n = 6 [2.5%]). In the fluoroscopy-guided group (Group II), a completely intrapedicular course graded A was found in 79.8% (n = 130). The remaining screws were graded B (n = 12 [7.4%]), C (n = 10 [6.1%]), D (n = 6 [3.7%]), and E (n = 5 [3.1%]). The comparison of "clinically acceptable" (that is, A and B screws) was neither different between groups (I vs II [p = 0.19]) nor subgroups (Subgroup IA vs IB [p = 0.81]; Subgroup IA vs Group II [p = 0.53]; Subgroup IB vs Group II [p = 0.20]). Blood loss was lower in the robot-assisted group than in the fluoroscopy-guided group, while duration of surgery, length of stay, and cumulative morphine dose were not statistically different. Conclusions Robot-guided pedicle screw placement is a safe and useful tool for assisting spine surgeons in degenerative spine cases. Nonetheless, technical difficulties remain and fluoroscopy backup is advocated.
Resumo:
The number of fluoroscopy-guided procedures in cardiology is increasing over time and it is appropriate to wonder whether technological progress or change of techniques is influencing patient exposure. The aim of this study is to examine whether patient dose has been decreasing over the years. Patient dose data of more than 7700 procedures were collected from two cardiology centres. A steady increase in the patient dose over the years was observed in both the centres for the two cardiological procedures included in this study. Significant increase in dose was also observed after the installation of a flat-panel detector. The increasing use of radial access may lead to an increase in the patient exposure. The monitoring of dose data over time showed a considerable increase in the patient exposure over time. Actions have to be taken towards dose reduction in both the centres.
Resumo:
Si l'examen clinique revêt une importance essentielle en lymphologie et exige des praticiens expérimentés, la lymphoscintigraphie et plus récemment la lympho-fluoroscopie au vert d'indocyanine constituent des moyens d'investigation précieux dans la prévention, le diagnostic et le traitement des pathologies vasculaires lymphatiques. L'intérêt de la lymphoscintigraphie réside dans l'analyse qualitative et quantitative de la migration des macromolécules par les vaisseaux lymphatiques et l'évaluation du secteur lymphatique profond. La lympho-fluoroscopie se distingue de la lymphoscintigraphie par l'obtention d'une cartographie détaillée des vaisseaux lymphatiques superficiels et d'images dynamiques en temps réel. Elle apporte à l'angiologue et au physiothérapeute des informations irremplaçables sur leur contractilité et la présence de dérivations compensatoires à privilégier lors du drainage lymphatique manuel. If clinical examination has an essential importance in lymphology disorders and requires experimented practitioners, lymphoscintigraphy and more recently green indocyanine lympho-fluoroscopy constitute precious complementary investigations in prevention, diagnosis, and treatment of lymphatic vascular pathologies. The lymphoscintigraphy interest lies in qualitative and quantitative analysis of macromolecules migration within lymphatic vessels and the deep lymphatic network. The lympho-fluoroscopy distinguishes itself from lymphoscintigraphy allowing real time superficial lymphatic vessels detailed mapping, gathering important information on their contractility, and the presence of compensatory derivations to be favored during manual lymphatic drainage to angiologist and physiotherapist.
Resumo:
The registration of pre-operative volumetric datasets to intra- operative two-dimensional images provides an improved way of verifying patient position and medical instrument loca- tion. In applications from orthopedics to neurosurgery, it has a great value in maintaining up-to-date information about changes due to intervention. We propose a mutual information- based registration algorithm to establish the proper align- ment. For optimization purposes, we compare the perfor- mance of the non-gradient Powell method and two slightly di erent versions of a stochastic gradient ascent strategy: one using a sparsely sampled histogramming approach and the other Parzen windowing to carry out probability density approximation. Our main contribution lies in adopting the stochastic ap- proximation scheme successfully applied in 3D-3D registra- tion problems to the 2D-3D scenario, which obviates the need for the generation of full DRRs at each iteration of pose op- timization. This facilitates a considerable savings in compu- tation expense. We also introduce a new probability density estimator for image intensities via sparse histogramming, de- rive gradient estimates for the density measures required by the maximization procedure and introduce the framework for a multiresolution strategy to the problem. Registration results are presented on uoroscopy and CT datasets of a plastic pelvis and a real skull, and on a high-resolution CT- derived simulated dataset of a real skull, a plastic skull, a plastic pelvis and a plastic lumbar spine segment.
Resumo:
This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.
Resumo:
OBJECTIVE: To design and evaluate a novel computer-assisted, fluoroscopy-based planning and navigation system for minimally invasive ventral spondylodesis of thoracolumbar fractures. MATERIALS AND METHODS: Instruments and an image intensifier are tracked with the SurgiGATE navigation system (Praxim-Medivision). Two fluoroscopic images, one acquired from anterior-posterior (AP) direction and the other from lateral-medial (LM) direction, are used for the complete procedure of planning and navigation. Both of them are calibrated with a custom-made software to recover their projection geometry and to co-register them to a common patient reference coordinate system, which is established by attaching an opto-electronically trackable dynamic reference base (DRB) on the operated vertebra. A bi-planar landmark reconstruction method is used to acquire deep-seated anatomical landmarks such that an intraoperative planning of graft bed can be interactively done. Finally, surgical actions such as the placement of the stabilization devices and the formation of the graft bed using a custom-made chisel are visualized to the surgeon by superimposing virtual instrument representations onto the acquired images. The distance between the instrument tip and each wall of the planned graft bed are calculated on the fly and presented to the surgeon so that the surgeon could formalize the graft bed exactly according to his/her plan. RESULTS: Laboratory studies on phantom and on 27 plastic vertebras demonstrate the high precision of the proposed navigation system. Compared with CT-based measurement, a mean error of 1.0 mm with a standard deviation of 0.1 mm was found. CONCLUSIONS: The proposed computer assisted, fluoroscopy-based planning and navigation system promises to increase the accuracy and reliability of minimally invasive ventral spondylodesis of thoracolumbar fractures.
Resumo:
OBJECTIVES: To carry out long-term follow-up after percutaneous closure of patent foramen ovale (PFO) in patients with cryptogenic stroke. DESIGN: Prospective cohort study. SETTING: Single tertiary care centre. PARTICIPANTS: 525 consecutive patients (mean (SD) age 51 (12) years; 56% male). INTERVENTIONS: Percutaneous PFO closure without intraprocedural echocardiography. MAIN OUTCOME MEASURES: Freedom from recurrent embolic events. RESULTS: A mean (SD) of 1.7 (1.0) clinically apparent embolic events occurred for each patient, and 186 patients (35%) had >1 event. An atrial septal aneurysm was associated with the PFO in 161 patients (31%). All patients were followed up prospectively for up to 11 years. The implantation procedure failed in two patients (0.4%). There were 13 procedural complications (2.5%) without any long-term sequelae. Contrast transoesophageal echocardiography at 6 months showed complete closure in 86% of patients, and a minimal, moderate or large residual shunt in 9%, 3% and 2%, respectively. Patients with small occluders (<30 mm; n = 429) had fewer residual shunts (small 11% vs large 27%; p<0.001). During a mean (SD) follow-up of 2.9 (2.2) years (median 2.3 years; total 1534 patient-years), six ischaemic strokes, nine transient ischaemic attacks (TIAs) and two peripheral emboli occurred. Freedom from recurrent stroke, TIA, or peripheral embolism was 98% at 1 year, 97% at 2 years and 96% at 5 and 10 years, respectively. A residual shunt (hazard ratio = 3.4; 95% CI 1.3 to 9.2) was a risk factor for recurrence. CONCLUSIONS: This study attests to the long-term safety and efficacy of percutaneous PFO closure guided by fluoroscopy only for secondary prevention of paradoxical embolism in a large cohort of consecutive patients.