997 resultados para F-P cavities
Resumo:
采用Pound-Drever-Hall技术,对用于多普勒测风雷达的种子注入激光器的主动激光器进行稳频,将其频率锁定在一个特殊设计的法珀腔上。该法珀腔总体采用零膨胀微晶玻璃材料制成,具有极高的温度稳定性。使用计算机采集鉴频信号并且进行处理。锁定后,1秒内激光器的相对频率漂移为±25kHz,一小时内的相对频率漂移为±55kHz,满足多普勒测风雷达的要求。
Resumo:
179 p.
Resumo:
We investigated four unique methods for achieving scalable, deterministic integration of quantum emitters into ultra-high Q{V photonic crystal cavities, including selective area heteroepitaxy, engineered photoemission from silicon nanostructures, wafer bonding and dimensional reduction of III-V quantum wells, and cavity-enhanced optical trapping. In these areas, we were able to demonstrate site-selective heteroepitaxy, size-tunable photoluminescence from silicon nanostructures, Purcell modification of QW emission spectra, and limits of cavity-enhanced optical trapping designs which exceed any reports in the literature and suggest the feasibility of capturing- and detecting nanostructures with dimensions below 10 nm. In addition to process scalability and the requirement for achieving accurate spectral- and spatial overlap between the emitter and cavity, these techniques paid specific attention to the ability to separate the cavity and emitter material systems in order to allow optimal selection of these independently, and eventually enable monolithic integration with other photonic and electronic circuitry.
We also developed an analytic photonic crystal design process yielding optimized cavity tapers with minimal computational effort, and reported on a general cavity modification which exhibits improved fabrication tolerance by relying exclusively on positional- rather than dimensional tapering. We compared several experimental coupling techniques for device characterization. Significant efforts were devoted to optimizing cavity fabrication, including the use of atomic layer deposition to improve surface quality, exploration into factors affecting the design fracturing, and automated analysis of SEM images. Using optimized fabrication procedures, we experimentally demonstrated 1D photonic crystal nanobeam cavities exhibiting the highest Q/V reported on substrate. Finally, we analyzed the bistable behavior of the devices to quantify the nonlinear optical response of our cavities.
Resumo:
Thermodynamical fluctuations in temperature and position exist in every physical system, and show up as a fundamental noise limit whenever we choose to measure some quantity in a laboratory environment. Thermodynamical fluctuations in the position of the atoms in the dielectric coatings on the mirrors for optical cavities at the forefront of precision metrology (e.g., LIGO, the cavities which probe atomic transitions to define the second) are a current limiting noise source for these experiments, and anything which involves locking a laser to an optical cavity. These thermodynamic noise sources scale physical geometry of experiment, material properties (such as mechanical loss in our dielectric coatings), and temperature. The temperature scaling provides a natural motivation to move to lower temperatures, with a potential huge benefit for redesigning a room temperature experiment which is limited by thermal noise for cryogenic operation.
We design, build, and characterize a pair of linear Fabry-Perot cavities to explore limitations to ultra low noise laser stabilization experiments at cryogenic temperatures. We use silicon as the primary material for the cavity and mirrors, due to a zero crossing in its linear coefficient of thermal expansion (CTE) at 123 K, and other desirable material properties. We use silica tantala coatings, which are currently the best for making high finesse low noise cavities at room temperature. The material properties of these coating materials (which set the thermal noise levels) are relatively unknown at cryogenic temperatures, which motivates us to study them at these temperatures. We were not able to measure any thermal noise source with our experiment due to excess noise. In this work we analyze the design and performance of the cavities, and recommend a design shift from mid length cavities to short cavities in order to facilitate a direct measurement of cryogenic coating noise.
In addition, we measure the cavities (frequency dependent) photo-thermal response. This can help characterize thermooptic noise in the coatings, which is poorly understood at cryogenic temperatures. We also explore the feasibility of using the cavity to do macroscopic quantum optomechanics such as ground state cooling.
Resumo:
Silicon is known to be a very good material for the realization of high-Q, low-volume photonic cavities, but at the same it is usually considered as a poor material for nonlinear optical functionalities like second-harmonic generation, because its second-order nonlinear susceptibility vanishes in the dipole approximation. In this work we demonstrate that nonlinear optical effects in silicon nanocavities can be strongly enhanced and even become macroscopically observable. We employ photonic crystal nanocavities in silicon membranes that are optimized simultaneously for high quality factor and efficient coupling to an incoming beam in the far field. Using a low-power, continuous-wave laser at telecommunication wavelengths as a pump beam, we demonstrate simultaneous generation of second- and third harmonics in the visible region, which can be observed with a simple camera. The results are in good agreement with a theoretical model that treats third-harmonic generation as a bulk effect in the cavity region, and second-harmonic generation as a surface effect arising from the vertical hole sidewalls. Optical bistability is also observed in the silicon nanocavities and its physical mechanisms (optical, due to two-photon generation of free carriers, as well as thermal) are investigated. © 2011 IEEE.
Resumo:
Water-soluble tetra-p-sulfonatocalix[4]arene, acting as a four-connected node, bridges the rare earth cations into a 3D porous MOF in which 1D smaller circular hydrophilic channels and larger quadratic ones are lined up along the c axis and interconnected to each other by the calixarene cavities and other interstices.
Resumo:
A novel manganese phosphomolybdate, [H3N(CH2)(4)NH3](H3O)(2){[Mn(phen)(2)](4)[(MnMovO30)-O-12(HPO4)(6)(H2PO4)(2)]} . 4H(2)O 1, has been hydrothermally synthesized and structurally characterized by single crystal X-ray diffraction. The crystal data: triclinic, P (1) over bar, a = 14.172(7) Angstrom, b = 16.547(2) Angstrom, c = 16.679(3) Angstrom, alpha = 62.881(12)degrees, beta = 73.83(3)degrees, gamma = 88.81(3)degrees. X-ray crystallography shows that the [Mn(phen)(2)] fragments are covalently bonded to the [Mn(Mo6P4)(2)] dimers leading to a one-dimensional chain with rectangular cavities occupied by tetramethylene-diamine cations and water molecules. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Subwavelength resonators at FIR are presented and studied. The structures consist of 1D cavities formed between a metallized (silver) surface and a metamaterial surface comprising a periodic array of silver patches on a silver-backed silicon substrate. The concept derives from recent discoveries of artificial magnetic conductors (AMC). By studying the currents excited on the metamaterial surface by a normally incident plane wave, the nature of the emerging resonant phenomena and the physical mechanism underlying the AMC operation are investigated. Full wave simulations, based on finite element method and time-domain transmission line modelling technique, have been carried out to demonstrate the effective AMC boundary condition and prove the possibilities for subwavelength cavities. The quality factor of the resonant cavities is assessed as a function of the cavity profile. It is demonstrated that the quality factor drops to about 1/8 of the half-wavelength value for lambda/8 resonant cavity.
Resumo:
Recently [A. Xuereb, et al., Phys. Rev. Lett. 105, 013602 (2010)], we calculated the radiation field and the optical forces acting on a moving object inside a general one-dimensional configuration of immobile optical elements. In this article we analyse the forces acting on a semi-transparent mirror in the 'membrane-in-the-middle' configuration and compare the results obtained from solving scattering model to those from the coupled cavities model that is often used in cavity optomechanical system. We highlight the departure of this model from the more exact scattering theory when the reflectivity of the moving element drops below about 50%.
Resumo:
At present, few data are available on the prevalence and antifungal susceptibility of Candida parapsilosis complex isolates from HIV-infected individuals. The C. parapsilosis complex comprises three species, C. parapsilosis sensu stricto, C. metapsilosis and C. orthopsilosis. Fifteen of 318 Candida isolates were identified as members of the C. parapsilosis complex by PCR and restriction fragment length polymorphism (RFLP). The prevalence of C. parapsilosis complex isolates was 4.7 %, 2.2 % being identified as C. parapsilosis sensu stricto and 2.5% as C. metapsilosis, while no C. orthopsilosis was isolated. This is believed to be the first study that has identified isolates of C. metapsilosis obtained from the oral cavity of HIV-infected individuals. Antifungal susceptibility tests indicated that all the isolates were susceptible to amphotericin B (AMB), fluconazole (FLC), ketoconazole (KTC), itraconazole (ITC), voriconazole (VRC) and caspofungin (CASPO). Although isolates of C. parapsilosis sensu stricto and C. metapsilosis were susceptible to FLC, isolates of C. metapsilosis showed a tendency for higher MICs (>= 1.0 mu g ml(-1)). Based upon the frequency of candidiasis and the fact that certain isolates of the C. parapsilosis complex respond differently to FLC therapy, our data may be of therapeutic relevance with respect to susceptibility and potential resistance to specific antifungal agents. Our data suggest that C. metapsilosis can be a human commensal; its importance as a pathogen has yet to be confirmed.
Resumo:
Background: the purpose of this study was to histomorphometrically evaluate the response of periodontal tissues covering Class V resin restorations in dogs.Methods: After raising a mucoperiosteal flap, bony defects measuring 5 x 5 mm were created on the buccal aspect of the canines of five dogs followed by cavity preparations on the root surface measuring 3 x 3 x 1 mm. Before repositioning the flap to cover the bone defect, the cavities were restored with composite resin (CR) or resin-modified glass ionomer cement (RMGIC) or were left unrestored as control (C). The dogs were euthanized 90 days after surgery. Specimens comprising the tooth and periodontal tissues were removed, processed routinely, cut into longitudinal serial sections in the bucco-lingual direction, and stained with hematoxylin and eosin (H&E) or Masson's trichrome. The most central sections were selected for histomorphometric analysis.Results: Histomorphometric analysis revealed apical migration of epithelial tissue onto the restorative materials (RMGIC and CR). The C group presented significantly longer connective tissue attachment (P < 0.05) than the RMGIC and CR groups and significantly higher bone regeneration (P < 0.05) compared to the RMGIC group. Histologically, the cervical third (CT) of all groups had the most marked chronic inflammatory infiltrate.Conclusions: Within the limits of this study, it can be concluded that the restorative materials used exhibit biocompatibility; however, both materials interfered with the development of new bone and the connective tissue attachment process.
Resumo:
Objectives. To evaluate the response of the pulpo-dentin complex following application of a resin-modified glass-ionomer cement or an adhesive system in deep cavities performed in human teeth.Methods. Deep class V cavities were prepared on the buccal surface of 26 premolars. In Group I the cavity walls (dentin) and enamel were conditioned with 32% phosphoric acid and the dentin adhesive system One Step (Bisco, Inc., Itasca, IL, USA) was applied. In Groups 2 and 3, before total etching and application of bonding agent, the cavity floor was lined with the resin-modified glass-ionomer cement-Vitrebond (3M ESPE Dental Products Division, St. Paul, MN, USA) or the calcium hydroxide cement-Dycal (control group, Dentsply, Mildford, DE, USA), respectively. The cavities were restored using light-cured Z-100 composite resin (3M ESPE). The teeth were extracted between 5 and 30 days and prepared for microscopic assessment. Serial sections were stained with H/E, Masson's trichrome, and Brown and Brenn techniques.Results. In Group 1, the inflammatory response was more evident than in Groups 2 and 3. Diffusion of dental material components across dentinal tubules was observed only in Group 1, in which the intensity of the pulp response increased as the remaining dentin thickness decreased. Bacteria were evidenced in the lateral walls of two samples (Group 2) which exhibited no inflammatory response or tissue disorganization.Conclusions. Based on the experimental conditions, it was concluded total acid etching followed by application of One Step bonding agent cannot be recommended as adequate procedures. In this clinical condition the cavity walls should be lined with a biocompatible dental material, such as Vitrebond or Dycal. 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.