998 resultados para Eye ultrasound


Relevância:

70.00% 70.00%

Publicador:

Resumo:

With the advent of high frequency transducers, the use of ocular ultrasound has become widely used because it provides definitions of major ocular structures. This diagnostic tool is useful in the evaluation of ophthalmic injuries, and also used for qualitative and quantitative evaluation of intraocular and orbital lesions. It is a noninvasive, safe and fast, easy to use and can be performed in an awake animal. The ocular ultrasonography is indicated in cases of ocular opacity, when the ophthalmic examination cannot be done, and in eyes with ocular trauma or suspected orbital disease. Ultrasound biomicroscopy (UBM) is a diagnostic tool with high cost and sedation or general anesthesia is necessary, but has the advantage of evaluating structures poorly defined or visualized in the anterior segment of the eye. Therefore, this paper aims to show the importance of ocular ultrasonography and UBM to veterinary practitioners, and to demonstrate its advantages and indications in ophthalmic routine.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Obstetric ultrasound has come to play a significant role in obstetrics since its introduction in clinical care. Today, most pregnant women in the developed world are exposed to obstetric ultrasound examinations, and there is no doubt that the advantages of obstetric ultrasound technique have led to improvements in pregnancy outcomes. However, at the same time, the increasing use has also raised many ethical challenges. This study aimed to explore obstetricians' experiences of the significance of obstetric ultrasound for clinical management of complicated pregnancy and their perceptions of expectant parents' experiences. Methods: A qualitative study was undertaken in November 2012 as part of the CROss-Country Ultrasound Study (CROCUS). Semi-structured individual interviews were held with 14 obstetricians working at two large hospitals in Victoria, Australia. Transcribed data underwent qualitative content analysis. Results: An overall theme emerged during the analyses, 'Obstetric ultrasound - a third eye', reflecting the significance and meaning of ultrasound in pregnancy, and the importance of the additional information that ultrasound offers clinicians managing the surveillance of a pregnant woman and her fetus. This theme was built on four categories: I:'Everyday-tool' for pregnancy surveillance, II: Significance for managing complicated pregnancy, III: Differing perspectives on obstetric ultrasound, and IV: Counselling as a balancing act. In summary, the obstetricians viewed obstetric ultrasound as an invaluable tool in their everyday practice. More importantly however, the findings emphasise some of the clinical dilemmas that occur due to its use: the obstetricians' and expectant parents' differing perspectives and expectations of obstetric ultrasound examinations, the challenges of uncertain ultrasound findings, and how this information was conveyed and balanced by obstetricians in counselling expectant parents. Conclusions: This study highlights a range of previously rarely acknowledged clinical dilemmas that obstetricians face in relation to the use of obstetric ultrasound. Despite being a tool of considerable significance in the surveillance of pregnancy, there are limitations and uncertainties that arise with its use that make counselling expectant parents challenging. Research is needed which further investigates the effects and experiences of the continuing worldwide rapid technical advances in surveillance of pregnancies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two different methods to measure binocular longitudinal corneal apex movements were synchronously applied. High-speed videokeratoscopy at a sampling frequency of 15 Hz and a customdesigned ultrasound distance sensor at 100 Hz were used for the left and the right eye, respectively. Four healthy subjects participated in the study. Simultaneously, cardiac electric cycle (ECG) was registered for each subject at 100 Hz. Each measurement took 20 s. Subjects were asked to suppress blinking during the measurements. A rigid headrest and a bite-bar were used to minimize undesirable head movements. Time, frequency and time-frequency representations of the acquired signals were obtained to establish their temporal and spectral contents. Coherence analysis was used to estimate the correlation between the measured signals. The results showed close correlation between both corneal apex movements and the cardiopulmonary system. Unraveling these relationships could lead to better understanding of interactions between ocular biomechanics and vision. The advantages and disadvantages of the two methods in the context of measuring longitudinal movements of the corneal apex are outlined.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. To determine the agreement between observers in estimating the configuration of the human anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM). Methods. Two masked clinicians used UBM images to estimate, in 41 eyes, the configuration of the ACA, especially (1) the position of contact between the peripheral iris and the inside of the eye wall, (2) the angularity of the approach to the ACA, and (3) the curvature of the peripheral iris. Agreement between observers was evaluated by the kappa statistic. Results. Inter-observer agreement in assessing the iris insertion (kappa = 0.79), angular width (Kappa = 0.95), and the peripheral iris curvature (kappa = 0.84) was high. Conclusions. The agreement between observers in evaluating the anterior chamber angle configuration by UBM was excellent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate by ultrasound biomicroscopy (UBM) the anatomical characteristics and the intraocular pressure (IOP) lowering mechanisms of deep sclerectomy after long-term follow-up. Methods: In all, 22 eyes of 21 consecutive patients who had deep sclerectomy were examined by UBM. Several UBM variables were prospectively evaluated, including the presence and maximum length and height of the intrascleral space, the minimum thickness of residual trabeculo-Descemet membrane (TDM), the presence and type of subconjunctival filtering bleb, and the presence of other possible drainage sites, for example suprachoroidal. Surgical success was considered to be achieved when the IOP was

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine the intra- and interobserver agreement in assessing the configuration of the human anterior chamber angle using ultrasound biomicroscopy (UBM). Methods: Two masked clinicians used ubm images to estimate, in 41 eyes, (a) the position of contact between the peripheral iris and the inside of the eye wall, (b) the angular size of the anterior chamber angle (ACA), and (c) the curvature of the peripheral iris. Both observers, masked to the previous results, examined the same images in a second session. Agreement was evaluated using the unweighted ? statistic. Results: Intraobserver agreement in assessing the iris insertion, angular width, and the iris curvature was high (range of ? values, 0.83-0.92). Interobserver agreement in evaluating the level of iris insertion (? = 0.79), the angular width (? = 0.95), and the iris curvature (? = 0.84) was also high. Conclusion: The agreement within the same observer and between observers in evaluating the ACA configuration by UBM was excellent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To describe the distribution of central corneal thickness (CCT), intraocular pressure (IOP), and their determinants and association with glaucoma in Chinese adults.DESIGN: Population-based cross-sectional study.METHODS: Chinese adults aged 50 years and older were identified using cluster random sampling in Liwan District, Guangzhou. CCT (both optical [OCCT] and ultrasound [UCCT]), intraocular pressure (by Tonopen, IOP), refractive error (by autorefractor, RE), radius of corneal curvature (RCC), axial length (AL), and body mass index (BMI) were measured, and history of hypertension and diabetes (DM) was collected by questionnaire. Right eye data were analyzed.RESULTS: The mean values of OCCT, UCCT, and IOP were 512 ± 29.0 μm, 542 ± 31.4 μm, and 15.2 ± 3.1 mm Hg, respectively. In multiple regression models, CCT declined with age (P < .001) and increased with greater RCC (P < .001) and DM (P = .037). IOP was positively associated with greater CCT (P < .001), BMI (P < .001), and hypertension (P < .001). All 25 persons with open-angle glaucoma had IOP <21 mm Hg. CCT did not differ significantly between persons with and without open- or closed-angle glaucoma. Among 65 persons with ocular hypertension (IOP >97.5th percentile), CCT (555 ± 29 μm) was significantly (P = .01) higher than for normal persons.CONCLUSIONS: The distributions of CCT and IOP in this study are similar to that for other Chinese populations, though IOP was lower than for European populations, possibly due to lower BMI and blood pressure. Glaucoma with IOP <21 mm Hg is common in this population. We found no association between glaucoma and CCT, though power (0.3) for this analysis was low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty eight Mediterranean buffaloes bulls were scanned with real-time ultrasound (RTU), slaughtered, and fabricated into retail cuts to determine the potential for ultrasound measures to predict carcass retail yield. Ultrasound measures of fat thickness, ribeye area and rump fat thickness were recorded three to five days prior to slaughter. Carcass measurements were taken, and one side of each carcass was fabricated into retail cuts. Stepwise regression analysis was used to compare possible models for prediction of either kilograms or percent retail product from carcass mesaurements and ultrasound measures. Results indicate that possible prediction models for percent or kilograms of retail products using RTU measures were similar in their predictive power and accuracy when compared to models derived from carcass measurements. Both fat thickness and ribeye area were over-predicted when measured ultrasonically compared to measurements taken on the carcass in the cooler. The mean absolute differences for both traits are larger than the mean differences, indicating that some images were interpreted to be larger and some smaller than actual carcass measurements. Ultrasound measurements of REA and FT had positive correlations with carcass measures of the same traits (r=.96 for REA and r=.99 for FT). Standard errors of prediction currently are being used as the standard to certify ultrasound technicians for accuracy. Regression equations using live weight (LW), rib eye area (REAU) and subcutaneous fat thickness (FTU) between 12(th) and 13 (th) ribs and also over the biceps femoris muscle (FTP8) by ultrasound explained 95% of the variation in the hot carcass weight when measure immediately before slaughter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PurposeUltrasonographic evaluation of the eye is a relatively recent addition to routine ophthalmic diagnostics in small animal ophthalmology. Some parameters for ophthalmic biometry have been established. There are few studies in clinical avian ophthalmology that describe ultrasound images of eye in some nocturnal avian species and in other birds that do not belong to the Brazilian fauna, but the psittacine family is not represented. The purpose of this study was to describe the following measurements: the distances between cornea and anterior lens capsule (D1) between the anterior and posterior lens capsule (D2), between posterior lens capsule and optic papilla (D3) and the axial length.MethodSixty four transpalpebral ocular ultrasound examinations were performed on 32 Blue fronted Amazon parrots (Amazona aestiva) with no history of previous ophthalmic disease.Result and DiscussionThe measurements were taken in sagital planes using a 10 MHz linear probe without a standoff pad. The mean values for the left eye were; D1 0.17 +/- 0.03 cm, D2 0.35 +/- 0.02 cm, D3 0.73 +/- 0.04 cm and the axial length 1.26 +/- 0.06 cm. In the right eye D1 0.17 +/- 0.02 cm, D2 0.34 +/- 0.02 cm, D3 0.74 +/- 0.03 cm and the axial length 1.25 +/- 0.05 cm. No significant statistical difference was observed among the birds or between the left and right eye. The description of these parameters will allow the veterinary practitioner to evaluate the structural changes that specific diseases may cause in these animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ObjectiveThis study aimed to evaluate the benefit and specifically the feasibility of using ultrasound in ophthalmologic periconal block, and the occurrence of complications.Study designProspective experimental study.AnimalsTen healthy New Zealand White rabbits (6-8months of age), weighing 2.0-3.5kg.MethodsRabbits were anesthetized by intramuscular injection of acepromazine (1mgkg(-1)), ketamine (30mgkg(-1)) and xylazine (3mgkg(-1)). Ultrasound-assisted periconal block with lidocaine was performed on 18 eyes. Intraocular pressure was measured by applanation tonometry whereas corneal sensitivity was assessed using an esthesiometer, before and after each periconal anesthesia.ResultsIn all 18 eyes, it was possible to adequately visualize the needle shaft within the periconal space, as well as muscular cone, optic nerve and local anesthetic solution spread. Lidocaine 2% without epinephrine (0.790.19mL) was injected into the periconal space. There was no statistical difference between the intraocular pressure (meanSD) measured before (10.9 +/- 2.9mmHg) and after (11.9 +/- 3.8mmHg) the periconal anesthesia (p=0.38). The effectiveness of the ultrasound-assisted technique was shown according to the values for corneal sensitivity, assessed before and after periconal anesthesia (p<0.0001). Complications were not observed in this study.ConclusionsEye ultrasonography allowed visualization of all anatomic structures necessary to perform a periconal block, as well as the needle insertion and anesthetic spread in real time. Further studies are required to prove the real potential of ultrasound for reducing the incidence of complications associated with ophthalmic blocks, especially when anatomic disorders of the eye could potentially increase the risk.Clinical relevanceUltrasonography is a painless, noninvasive tool that may improve safety of ophthalmic regional blocks, potentially by reducing the prevalence of globe perforation or penetration of the optic nerve associated with the needle-based techniques.