964 resultados para Explosives, Military.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

"September 1984."

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"September 1984."

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"September 1984."

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Part of the maps, plans and diagrams folded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50μgcm(-2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The establishment of legislative rules about explosives in the eighties has reduced the illicit use of military and civilian explosives. However, bomb-makers have rapidly taken advantage of substances easily accessible and intended for licit uses to produce their own explosives. This change in strategy has given rise to an increase of improvised explosive charges, which is moreover assisted by the ease of implementation of the recipes, widely available through open sources. While the nature of the explosive charges has evolved, instrumental methods currently used in routine, although more sensitive than before, have a limited power of discrimination and allow mostly the determination of the chemical nature of the substance. Isotope ratio mass spectrometry (IRMS) has been applied to a wide range of forensic materials. Conclusions drawn from the majority of the studies stress its high power of discrimination. Preliminary studies conducted so far on the isotopic analysis of intact explosives (pre-blast) have shown that samples with the same chemical composition and coming from different sources could be differentiated. The measurement of stable isotope ratios appears therefore as a new and remarkable analytical tool for the discrimination or the identification of a substance with a definite source. However, much research is still needed to assess the validity of the results in order to use them either in an operational prospect or in court. Through the isotopic study of black powders and ammonium nitrates, this research aims at evaluating the contribution of isotope ratio mass spectrometry to the investigation of explosives, both from a pre-blast and from a post-blast approach. More specifically, the goal of the research is to provide additional elements necessary to a valid interpretation of the results, when used in explosives investigation. This work includes a fundamental study on the variability of the isotopic profile of black powder and ammonium nitrate in both space and time. On one hand, the inter-variability between manufacturers and, particularly, the intra-variability within a manufacturer has been studied. On the other hand, the stability of the isotopic profile over time has been evaluated through the aging of these substances exposed to different environmental conditions. The second part of this project considers the applicability of this high-precision technology to traces and residues of explosives, taking account of the characteristics specific to the field, including their sampling, a probable isotopic fractionation during the explosion, and the interferences with the matrix of the site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes an effective microchip protocol based on electrophoretic-separation and electrochemical detection for highly sensitive and rapid measurements of nitrate ester explosives, including ethylene glycol dinitrate (EGDN), pentaerythritol tetranitrate (PETN), propylene glycol dinitrate (PGDN) and glyceryl trinitrate (nitroglycerin, NG). Factors influencing the separation and detection processes were examined and optimized. Under the optimal separation conditions obtained using a 15 mM borate buffer (pH 9.2) containing 20 mM SDS, and applying a separation voltage of 1500 V, the four nitrate ester explosives were separated within less than 3 min. The glassy-carbon amperometric detector (operated at -0.9 V vs. Ag/AgCl) offers convenient cathodic detection down to the picogram level, with detection limits of 0.5 ppm and 0.3 ppm for PGDN and for NG, respectively, along with good repeatability (RSD of 1.8-2.3%; n = 6) and linearity (over the 10-60 ppm range). Such effective microchip operation offers great promise for field screening of nitrate ester explosives and for supporting various counter-terrorism surveillance activities.

Relevância:

20.00% 20.00%

Publicador: