979 resultados para Experimental program


Relevância:

100.00% 100.00%

Publicador:

Resumo:

no.l. General education for teachers.- no.2. Preparing teachers for secondary schools.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Work performed under contract no. W-7405-Eng-26."

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An extensive research program focused on the characterization of various metallurgical complex smelting and coal combustion slags is being undertaken. The research combines both experimental and thermodynamic modeling studies. The approach is illustrated by work on the PbO-ZnO-Al2O3-FeO-Fe2O3-CaO-SiO2 system. Experimental measurements of the liquidus and solidus have been undertaken under oxidizing and reducing conditions using equilibration, quenching, and electron probe X-ray microanalysis. The experimental program has been planned so as to obtain data for thermodynamic model development as well as for pseudo-ternary Liquidus diagrams that can be used directly by process operators. Thermodynamic modeling has been carried out using the computer system FACT, which contains thermodynamic databases with over 5000 compounds and evaluated solution models. The FACT package is used for the calculation of multiphase equilibria in multicomponent systems of industrial interest. A modified quasi-chemical solution model is used for the liquid slag phase. New optimizations have been carried out, which significantly improve the accuracy of the thermodynamic models for lead/zinc smelting and coal combustion processes. Examples of experimentally determined and calculated liquidus diagrams are presented. These examples provide information of direct relevance to various metallurgical smelting and coal combustion processes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The authors thank the federal agency CAPES and the Foundation for Research Support of the state of Sao Paulo, Brazil (FAPESP) for providing a PhD scholarship, and the University of Minho, in Portugal, for the international collaboration.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

O presente artigo é dedicado à avaliação experimental da eficiência do reforço com fibra de aço em termos da resistência à punção de lajes lisa carregadas simetricamente. Para este fim, oito lajes de 2550 x 2550 x 150 mm3 foram ensaiadas até a ruína, onde se investigou a influência do consumo de fibras (0, 60, 75 e 90 kg/m3) e da resistência do concreto (50 e 70 MPa). Duas lajes de referência, sem fibras, uma para cada classe de resistência do concreto, e uma laje para cada consumo de fibra e para cada classe de resistência do concreto compuseram o programa experimental. Todas as lajes foram armadas à flexão com barras de aço (armadura convencional) de forma a garantir a ruína por punção das lajes de referência. O único reforço transversal foi garantido pelas fibras de aço hooked ends com comprimento e diâmetro de 37 e 0,55 mm, respectivamente, e resistência à tração de aproximadamente 1100 MPa. Os resultados revelaram que as fibras de aço são muito eficientes em converter uma ruína frágil por cisalhamento em uma ruína dúctil por flexão, aprimorando ambos, carga de ruptura e deslocamento. Neste artigo o programa experimental é abordado em detalhe e os principais resultados são apresentados e discutidos.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Hybrid Composite Plate (HCP) is a reliable recently proposed retrofitting solution for concrete structures, which is composed of a strain hardening cementitious composite (SHCC) plate reinforced with Carbon Fibre Reinforced Polymer (CFRP). This system benefits from the synergetic advantages of these two composites, namely the high ductility of SHCC and the high tensile strength of CFRPs. In the materialstructural of HCP, the ultra-ductile SHCC plate acts as a suitable medium for stress transfer between CFRP laminates (bonded into the pre-sawn grooves executed on the SHCC plate) and the concrete substrate by means of a connection system made by either chemical anchors, adhesive, or a combination thereof. In comparison with traditional applications of FRP systems, HCP is a retrofitting solution that (i) is less susceptible to the detrimental effect of the lack of strength and soundness of the concrete cover in the strengthening effectiveness; (ii) assures higher durability for the strengthened elements and higher protection to the FRP component in terms of high temperatures and vandalism; and (iii) delays, or even, prevents detachment of concrete substrate. This paper describes the experimental program carried out, and presents and discusses the relevant results obtained on the assessment of the performance of HCP strengthened reinforced concrete (RC) beams subjected to flexural loading. Moreover, an analytical approach to estimate the ultimate flexural capacity of these beams is presented, which was complemented with a numerical strategy for predicting their load-deflection behaviour. By attaching HCP to the beams’ soffit, a significant increase in the flexural capacity at service, at yield initiation of the tension steel bars and at failure of the beams can be achieved, while satisfactory deflection ductility is assured and a high tensile capacity of the CFRP laminates is mobilized. Both analytical and numerical approaches have predicted with satisfactory agreement, the load-deflection response of the reference beam and the strengthened ones tested experimentally.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The present paper deals with the experimental assessment of the effectiveness of steel fibre reinforcement in terms of punching resistance of centrically loaded flat slabs, and to the development of an analytical model capable of predicting the punching behaviour of this type of structures. For this purpose, eight slabs of 2550 x 2550 x 150 mm3 dimensions were tested up to failure, by investigating the influence of the content of steel fibres (0, 60, 75 and 90 kg/m3) and concrete strength class (50 and 70 MPa). Two reference slabs without fibre reinforcement, one for each concrete strength class, and one slab for each fibre content and each strength class compose the experimental program. All slabs were flexurally reinforced with a grid of ribbed steel bars in a percentage to assure punching failure mode for the reference slabs. Hooked ends steel fibres provided the unique shear reinforcement. The results have revealed that steel fibres are very effective in converting brittle punching failure into ductile flexural failure, by increasing both the ultimate load and deflection, as long as adequate fibre reinforcement is assured. An analytical model was developed based on the most recent concepts proposed by the fib Mode Code 2010 for predicting the punching resistance of flat slabs and for the characterization of the behaviour of fibre reinforced concrete. The most refined version of this model was capable of predicting the punching resistance of the tested slabs with excellent accuracy and coefficient of variation of about 5%.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

O presente trabalho tem como objetivo estudar o comportamento de camadas superficiais de solo melhorado como base de fundações superficiais. Nesta pesquisa foram realizados ensaios de placa de 30 cm de diâmetro sobre camadas de solo residual compactado e de solo tratado com cimento (teor de 5% de cimento), ambas com 60 cm de espessura. O programa experimental também incluiu a retirada de amostras de campo das camadas de solo melhorado para a execução de ensaios triaxiais drenados (CID) com medida interna de deformações, a fim de obter parâmetros constitutivos para a realização de simulações numéricas. Uma comparação entre os resultados dos ensaios triaxiais com amostras retiradas em campo e moldadas em laboratório (Rohlfes Junior, 1996) é apresentada. A diferença entre os resultados dos ensaios triaxiais com amostras de campo e laboratório foi significativa para o caso das amostras de solo melhorado com cimento, tal fato é atribuído principalmente a dificuldade de mistura em campo. O Método dos Elementos Finitos foi utilizado para simular o comportamento carga x recalque das placas assentes sobre camadas de solo melhorado. O modelo Pseudo-Elástico Não Linear (Hiperbólico) foi empregado na análise numérica para modelar o comportamento dos novos materiais. Os resultados dos ensaios de placa sobre camadas de solo melhorado demonstraram que houve um aumento significativo da capacidade de suporte, além de uma redução considerável dos recalques, quando comparados ao comportamento carga x recalque do solo natural (Cudmani, 1994). A analise do comportamento de fundações superficiais assentes em solos estratificados, através de simulações numéricas, demonstrou ser eficiente para a previsão do comportamento carga x recalque das mesmas.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aims of this work are: (i) to produce new experimental data for fretting fatigue considering the presence of a mean bulk stress and (ii) to assess two design methodologies against failure by fretting fatigue. Tests on a cylinder–flat contact configuration were conducted using a fretting apparatus mounted on a servo-hydraulic machine. The material used for both the pads and fatigue specimen was an aeronautical 7050-T7451 Al alloy. The experimental program was designed with all relevant parameters, apart from the mean bulk load (always applied before the contact loads), kept constant. The mean bulk stress varied from compressive to tensile values while maintaining a high peak pressure in order to encourage crack initiation. Two methodologies against fretting fatigue are proposed and confronted against the experimental data. The non-local stress-based methodology considers the evaluation of a critical plane fatigue criterion at the center of a process zone located beneath the contacting surfaces. The results showed that it correctly predicts crack initiation, but was not capable to provide successful prediction of the integrity of the specimens. Alternatively, we considered a crack arrest criterion which has the potential to provide a more complete description about the integrity of the specimens.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The increasing use of Fiber Reinforced methods for strengthening existing brick masonry walls and columns, especially for the rehabilitation of historical buildings, has generated considerable research interest in understanding the failure mechanism in such systems. This dissertation is aimed to provide a basic understanding of the behavior of solid brick masonry walls unwrapped and wrapped with Fiber Reinforced Cementitious Matrix Composites. This is a new type of composite material, commonly known as FRCM, featuring a cementitious inorganic matrix (binder) instead of the more common epoxy one. The influence of the FRCM-reinforcement on the load-carrying capacity and strain distribution during compression test will be investigated using a full-field optical technique known as Digital Image Correlation. Compression test were carried on 6 clay bricks columns and on 7 clay brick walls in three different configuration, casted using bricks scaled respect the first one with a ratio 1:2, in order to determinate the effects of FRCM reinforcement. The goal of the experimental program is to understand how the behavior of brick masonry will be improved by the FRCM-wrapping. The results indicate that there is an arching action zone represented in the form of a parabola with a varying shape according to the used configuration. The area under the parabolas is considered as ineffectively confined. The effectively confined area is assumed to occur within the region where the arching action had been fully developed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Los polímeros armados con fibras (FRP) se utilizan en refuerzos de estructuras de hormigón debido sobre todo a sus excelentes propiedades mecánicas, su resistencia a la corrosión y a su ligereza que se traduce en facilidad y ahorro en el transporte, puesta en obra y aplicación, la cual se realiza de forma muy rápida, con pocos operarios y utilizando medios auxiliares ligeros, minimizándose las interrupciones del uso de la estructura y las molestias a los usuarios. Las razones presentadas anteriormente, han despertado un gran inter´es por parte de diferentes grupos de investigación a nivel mundial y que actualmente se encuentran desarrollando nuevas técnicas de aplicación y métodos de cálculo. Sin embargo, las investigaciones realizadas hasta la fecha, muestran un procedimiento bien definido y aceptado en lo referente al cálculo a flexión, lo cual no ocurre con el refuerzo a cortante y aunque se ha demostrado que el refuerzo con FRP es un sistema eficaz para incrementar la capacidad ´ultima frente a esfuerzos cortantes, también se pone de manifiesto la necesidad de más estudios experimentales y teóricos para avanzar en el entendimiento de los mecanismos involucrados para este tipo de refuerzo y establecer un procedimiento de diseño apropiado que maximice las excelentes propiedades de este material. Los modelos que explican el comportamiento del refuerzo a cortante de elementos de hormigón armado son complejos y sin transposición directa a fórmulas ingenieriles. Las normas actualmente en vigor, generalmente, establecen empíricamente la capacidad cortante como la suma de las capacidades del hormigón y el refuerzo transversal de acero. Cuando un elemento es reforzado externamente con FRP, los modelos son evidentemente aun más complejos. Las guías y recomendaciones existentes proponen calcular la capacidad del elemento añadiendo la resistencia aportada por el refuerzo externo de FRP a la ya dada por el hormigón y acero transversal. Sin embargo, la idoneidad de este acercamiento es cuestionable puesto que no tiene en cuenta una posible interacción entre refuerzos. Con base en lo anterior se da origen al tema objeto de este trabajo, el cual está orientado al estudio a cortante de elementos de hormigón armado (HA), reforzados externamente con material compuesto de tejido unidireccional de fibra de carbono y resina epoxi. Inicialmente se hace una completa revisión del estado actual del conocimiento de la resistencia a cortante en elementos de hormigón armado con y sin refuerzo externo de FRP, prestando especial atención en los mecanismos actuantes estudiados hasta la fecha. La bibliografía consultada ha sido exhaustiva y actualizada lo que ha permitido el estudio de los modelos propuestos más importantes, tanto para la descripción del fenómeno de adherencia entre hormigón-FRP como de la valoración del aporte al cortante total hecho por el FRP, a través de sendas bases de datos de ensayos de pull-out y de vigas de hormigón armado ensayadas a cortante. Con base en todo lo anterior, se expusieron los mecanismos actuantes en el aporte a cortante hecho por el FRP en elementos de hormigón armado y la forma como las principales guías de cálculo existentes hasta la fecha los abordan. De igual forma se define un modelo de resistencia de esfuerzos para el FRP y se proponen dos modelos para el cálculo de las tensiones o deformaciones efectivas, de los cuales uno esta basado en el modelo de adherencia propuesto por Oller (2005) y el otro en una regresión multivariante para los mecanismos expuestos. Como complemento del estudio de los trabajos encontrados en la literatura, se lleva acabo un programa experimental que, además de aportar más registros a la exigua base de datos existentes, aporte mayor luz a los puntos que se consideran están deficientemente resueltos. Dentro de este programa se realizaron 32 ensayos sobre 16 vigas de 4.5 m de longitud (dos ensayos por viga), reforzadas a cortante con tejido unidireccional de CFRP. Finalmente, estos estudios han permitido proponer modificaciones a las formulaciones existentes en los códigos y guías en vigor. Abstract Its excellent mechanical properties, as well as its corrosion resistance and light weight, which make it easy to apply and inexpensive to ship to the worksite, are the basis of the extended use of fiber reinforced polymer (FRP) as external strengthening for structures. FRP strengthening is a rapid operation calling for only limited labor and lightweight ancillary equipment, all of which minimizes both the interruption of facility usage and user inconvenience. These advantages have aroused considerable interest in civil engineering science and technology and have led to countless applications the world over. Research studies on the shear strength of FRP-strengthened members have been much fewer in number and more controversial than the research on flexural strengthening, for which a more or less standardized and generally accepted procedure has been established. The research conducted and a host of applications around the world have shown that FRP strengthening is an effective technique for raising ultimate shear strength, but it has also revealed a need for further experimental and theoretical research to advance in the understanding of the mechanisms involved and establish suitable design procedures that optimize the excellent properties of this material The models that explain reinforced concrete (RC) shear strength behavior are complex and cannot be directly transposed to engineering formulas. The standards presently in place generally establish shear capacity empirically as the sum of the capacities of the concrete and the passive reinforcement. When members are externally strengthened with FRP, the models are obviously even more complex. The existing guides and recommendations propose calculating capacity by adding the external strength provided by the FRP to the contributions of the concrete and passive reinforcement. The suitability of this approach is questionable, however, because it fails to consider the interaction between passive reinforcement and external strengthening. The subject of this work is based in above, which is focused on externally shear strengthening for reinforced concrete members with unidirectional carbon fiber sheets bonded with epoxy resin. v Initially a thorough literature review on shear of reinforced concrete beams with and without external FRP strengthening was performed, paying special attention to the acting mechanisms studied to date, which allowed the study of the most important models both to describe the bond phenomenon as well as calculating the FRP shear contribution, through separate databases of pull-out tests and shear tests on reinforced concrete beams externally strengthened with FRP. Based on above, they were exposed the acting mechanisms in a FRP shear strengthening on reinforced concrete beams and how guidelines deal the topic. The same way, it is defined a FRP stress strength model and two more models are proposed for calculating the effective stress, one of these is based on the Oller (2005) bond model and another one is the data best fit, taking into account most of the acting mechanisms. To complement the theoretical part we develop an experimental program that, in addition to providing more records to the meager existing database provide greater understanding to the points considered poorly resolved. The test program included 32 tests of 16 beams (2 per beam) of 4.5 m long, shear strengthened with FRP, externally. Finally, modifications to the existing codes and guidelines are proposed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Many of the material models most frequently used for the numerical simulation of the behavior of concrete when subjected to high strain rates have been originally developed for the simulation of ballistic impact. Therefore, they are plasticity-based models in which the compressive behavior is modeled in a complex way, while their tensile failure criterion is of a rather simpler nature. As concrete elements usually fail in tensión when subjected to blast loading, available concrete material models for high strain rates may not represent accurately their real behavior. In this research work an experimental program of reinforced concrete fíat elements subjected to blast load is presented. Altogether four detonation tests are conducted, in which 12 slabs of two different concrete types are subjected to the same blast load. The results of the experimental program are then used for the development and adjustment of numerical tools needed in the modeling of concrete elements subjected to blast.