986 resultados para Existing Buildings


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The resources listed in this document describe the design and construction opportunities available to building owners who wish to re-Life their properties. They do not yet examine management opportunities, which may also help owners improve the efficiency of their existing stock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a series of centrifuge tests carried out to investigate the performance of non-structural inclined micro-piles as a potential liquefaction remediation method for existing buildings. Both a single-degree-of-freedom frame structure and a two-storey, two-degree-of-freedom frame structure were used as model buildings in these tests. Centrifuge tests were carried out with and without micro-piles in the foundation soil for each structure. Results primarily from the tests with the SDOF structure are presented in this paper. It is found that the micro-piles have some beneficial effect by increasing shear strains in the soil in their vicinity and hence causing dilation in these zones. However, they also increase structural accelerations by transmitting accelerations from deep in the soil and the beneficial effects from increased dilation are outweighed by the detrimental migration of pore pressures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes four centrifuge tests investigating the performance of non-structural inclined micro-piles as a liquefaction remediation method for existing buildings. Two soil profiles with the same superstructure founded on each were tested under earthquakes of different magnitudes and durations. The first profile consisted of a deep, homogeneous layer of loose, liquefiable sand. The second comprised a shallow layer of loose sand overlying dense sand. Centrifuge tests were carried out with and without inclined micro-piles in each soil profile. The superstructure was modelled as an idealised single degree of freedom (SDOF) system. It is found that the micro-piles have no detrimental effect on the performance of the structure during and after earthquakes. It is also possible that their presence may decrease structural settlements in earthquakes which cause liquefaction to a depth less than that of the improved zone. However, no conclusive evidence is obtained to show that the micro-piles significantly restrain lateral soil movement due to monotonic shearing from the structure or impede the migration of excess pore pressures from the free field to the foundation zone. Both these processes have critical effects on structural settlement. The use of inclined micro-piles for liquefaction remediation should therefore be considered with caution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many typical liquefaction remediation techniques are not appropriate for application under existing buildings and more novel techniques are required. This paper describes centrifuge tests investigating the performance of cementation as a liquefaction remediation method. Two soil profiles with the same superstructure were tested under earthquake shaking. The first profile consisted of a deep layer of loose, liquefiable sand. The second comprised a shallow layer of loose sand overlying dense sand. Centrifuge tests were carried out with a cemented zone underneath the structure, through the full depth of the liquefiable layers and also partial depth. The superstructure was modelled as a single-degree-offreedom system. It is found that a cemented zone through the full depth of a liquefiable layer results in considerable reduction of structural settlements. Increased magnitude and higher frequency accelerations are transmitted to the structure but, depending on the building characteristics, it is likely that improved overall seismic performance can be achieved. Improvements in structural settlements can also be obtained with partialdepth remediation, if the depth of the cemented zone is greater than the depth of liquefaction. This type of remediation seems to have little effect on the accelerations transmitted to the structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Building roofs play a very important role in the energy balance of buildings, especially in summer, when they are hit by a rather high solar irradiance. Depending on the type of finishing layer, roofs can absorb a great amount of heat and reach quite high temperatures on their outermost surface, which determines significant room overheating. However, the use of highly reflective cool materials can help to maintain low outer surface temperatures; this practice may improve indoor thermal comfort and reduce the cooling energy need during the hot season.This technology is currently well known and widely used in the USA, while receiving increasing attention in Europe. In order to investigate the effectiveness of cool roofs as a passive strategy for passive cooling in moderately hot climates, this paper presents the numerical results of a case study based on the dynamic thermal analysis of an existing office building in Catania (southern Italy, Mediterranean area). The results show how the application of a cool paint on the roof can enhance the thermal comfort of the occupants by reducing the operative temperatures of the rooms and to reduce the overall energy needs of the building for space heating and cooling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of climate change and global warming has received increased attention in society with constant reminders about the importance of energy efficiency and sustainability in buildings. Whilst the focus is often placed on smaller items such as plastic bags, air conditioners and motor vehicles, the emphasis has recently shifted to structures in the built environment. Office buildings have been identified as contributing significantly to global warming during their building lifecycle with a substantial contribution to CO2 omissions. In response, building designs and construction techniques have evolved over time to improve energy efficiency and reduce CO2 omissions. Whilst property valuers, managers and analysts must remain up-to-date regarding changes, relatively little research has been conducted about whether and how increased sustainability, such as signified in a Green Star rating affects a property’s highest and best value and long-term lifecycle. This study investigates the degree to which sustainability is understood in the property marketplace, especially in relation to property values with the emphasis placed on a cost- benefit analysis from both an owner’s and tenant’s perspective. Whilst it may be argued that incorporating sustainability into a new office building is cost prohibitive on a financial cost-benefit analysis, often various minor steps can be taken to upgrade the sustainability of an existing building. This project examines recent trends in capital expenditure to increase the sustainability of offices and where Green Star ratings have been applied to establish whether any corresponding increase in value is evident. In order to develop a researchframework, a thorough literature review will be conducted of recent Australian and overseas studies. This will enable links between sustainability and office buildings to be highlighted, and vitally how they affect a property’s value in both the short and long-term.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The improvement of energy efficiency in existing buildings is always a challenge due to their particular, and sometimes protected, constructive solutions. New constructive regulations in Spain leave a big undefined gap when a restoration is considered because they were developed for new buildings. However, rehabilitation is considered as an opportunity for many properties because it allows owners to obtain benefits from the use of the buildings. The current financial and housing crisis has turned society point of view to existing buildings and making them more efficient is one of the Spanish government’s aims. The economic viability of a rehabilitation action should take all factors into account: both construction costs and the future operative costs of the building must be considered. Nevertheless, the application of these regulations in Spain is left to the designer’s opinion and always under a subjective point of view. With the research work described in this paper and with the help of some case-studies, the cost of adapting an existing building to the new constructive regulations will be studied and Energetic Efficiency will be evaluated depending on how the investment is recovered. The interest of the research is based on showing how new constructive solutions can achieve higher levels of efficiency in terms of energy, construction and economy and it will demonstrate that Life Cycle Costing analysis can be a mechanism to find the advantages and disadvantages of using these new constructive solutions. Therefore, this paper has the following objectives: analysing constructive solutions in existing buildings - to establish a process for assessing total life cycle costs (LCC) during the planning stages with consideration of future operating costs - to select the most advantageous operating system – To determine the return on investment in terms of construction costs based on new techniques, the achieved energy savings and investment payback periods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliographies and indexes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Green building is building that the focus is to maximize the energy efficiency and resources used. While, retrofitting is the process of renovate or refurnish the existing building. Therefore by retrofit existing buildings that comply with green building requirement, it improves the environmental attributes of the buildings. In Malaysia, existing buildings and its communities contribute over 40% of green house gases to the environment. This paper describes a study that explores the potential to retrofit existing campus buildings that response to sustainable green building standard. A validation survey was carried out and the data collected was analysed using SPSS in order to confirm the significance of retrofitting Universiti Teknologi Malaysia (UTM) buildings toward green building initiative. The results show that all the twenty eight identified green elements recorded average index of higher than 3.5 which means that there is significant needs to retrofit the existing buildings to green buildings. This study concludes that it is urgently need for the campus to response to green building requirements in order to achieve higher energy effeciency and this can be done through effective etrofitting of existing buildings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The retrofitting of existing buildings for decreased energy usage, through increased energy efficiency and for minimum carbon dioxide emissions throughout their remaining lifetime is a major area of research. This research area requires development to provide building professionals with more efficient building retrofit solution determination tools. The overarching objective of this research is to develop a tool for this purpose through the implementation of a prescribed methodology. This has been achieved in three distinct steps. Firstly, the concept of using the degree-days modelling method as an adequate means of basing retrofit decision upon was analysed and the results illustrated that the concept had merit. Secondly, the concept of combining the degree-days modelling method and the Genetic Algorithms optimisation method is investigated as a method of determining optimal thermal energy retrofit solutions. Thirdly, the combination of the degree-days modelling method and the Genetic Algorithms optimisation method were packaged into a building retrofit decision-support tool and named BRaSS (Building Retrofit Support Software). The results demonstrate clearly that, fundamental building information, simplified occupancy profiles and weather data used in a static simulation modelling method is a sufficient and adequate means to base retrofitting decisions upon. The results also show that basing retrofit decisions upon energy analysis results are the best means to guide a retrofit project and also to achieve results which are optimum for a particular building. The results also indicate that the building retrofit decision-support tool, BRaSS, is an effective method to determine optimum thermal energy retrofit solutions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

With the accelerated trend of global warming, the thermal behavior of existing buildings, which were typically designed based on current weather data, may not be able to cope with the future climate. This paper quantifies, through computer simulations, the increased cooling loads imposed by potential global warming and probable indoor temperature increases due to possible undersized air-conditioning system. It is found from the sample office building examined that the existing buildings would generally be able to adapt to the increasing warmth of 2030 year Low and High scenarios projections and 2070 year Low scenario projection. However, for the 2070 year High scenario, the study indicates that the existing office buildings, in all capital cities except for Hobart, will suffer from overheating problems. When the annual average temperature increase exceeds 2°C, the risk of current office buildings subjected to overheating will be significantly increased. For existing buildings which are designed with current climate condition, it is shown that there is a nearly linear correlation between the increase of average external air temperature and the increase of building cooling load. For the new buildings, in which the possible global warming has been taken into account in the design, a 28-59% increase of cooling capacity under 2070 High scenario would be required to improve the building thermal comfort level to an acceptable standard.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

As climate change will entail new conditions for the built environment, the thermal behaviour of air-conditioned office buildings may also change. Using building computer simulations, the impact of warmer weather is evaluated on the design and performance of air-conditioned office buildings in Australia, including the increased cooling loads and probable indoor temperature increases due to a possibly undersized air-conditioning system, as well as the possible change in energy use. It is found that existing office buildings would generally be able to adapt to the increasing warmth of year 2030 Low and High scenarios projections and the year 2070 Low scenario projection. However, for the 2070 High scenario, the study indicates that the existing office buildings in all capital cities of Australia would suffer from overheating problems. For existing buildings designed for current climate conditions, it is shown that there is a nearly linear correlation between the increase of average external air temperature and the increase of building cooling load. For the new buildings designed for warmer scenarios, a 28-59% increase of cooling capacity under the 2070 High scenario would be required.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Post-earthquake fire (PEF) is considered one of the most high risk and complicated problems affecting buildings in urban areas and can cause even more damage than the earthquake itself. However, most standards and codes ignore the implications of PEF and so buildings are not normally designed with PEF in mind. What is needed is for PEF factors to be routinely scrutinized and codified as part of the design process. A systematic application is presented as a means of mitigating the risk of PEF in urban buildings. This covers both existing buildings, in terms of retrofit solutions, and those yet to be designed, where a PEF factor is proposed. To ensure the mitigation strategy meets the defined criteria, a minimum time is defined – the safety guaranteed time target – where the safety of the inhabitants in a building is guaranteed.