568 resultados para Evaporative cooler
Resumo:
This paper presents the basic principles of the evaporative cooling process for human thermal comfort, the principles of operation for the direct evaporative cooling system and the mathematical development of the equations of thermal exchanges, allowing the determination of the effectiveness of saturation. It also presents the results of experimental tests in a direct evaporative cooler that take place in the Air Conditioning Laboratory at the University of Taubate Mechanical Engineering Department, and the experimental results are used to determinate the convective heat transfer co-efficient and to compare with the mathematical model. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
Resumo:
In this paper, numerical analyses of the thermal performance of an indirect evaporative air cooler incorporating a M-cycle cross-flow heat exchanger has been carried out. The numerical model was established from solving the coupled governing equations for heat and mass transfer between the product and working air, using the finite-element method. The model was developed using the EES (Engineering Equation Solver) environment and validated by published experimental data. Correlation between the cooling (wet-bulb) effectiveness, system COP and a number of air flow/exchanger parameters was developed. It is found that lower channel air velocity, lower inlet air relative humidity, and higher working-to-product air ratio yielded higher cooling effectiveness. The recommended average air velocities in dry and wet channels should not be greater than 1.77 m/s and 0.7 m/s, respectively. The optimum flow ratio of working-to-product air for this cooler is 50%. The channel geometric sizes, i.e. channel length and height, also impose significant impact to system performance. Longer channel length and smaller channel height contribute to increase of the system cooling effectiveness but lead to reduced system COP. The recommend channel height is 4 mm and the dimensionless channel length, i.e., ratio of the channel length to height, should be in the range 100 to 300. Numerical study results indicated that this new type of M-cycle heat and mass exchanger can achieve 16.7% higher cooling effectiveness compared with the conventional cross-flow heat and mass exchanger for the indirect evaporative cooler. The model of this kind is new and not yet reported in literatures. The results of the study help with design and performance analyses of such a new type of indirect evaporative air cooler, and in further, help increasing market rating of the technology within building air conditioning sector, which is currently dominated by the conventional compression refrigeration technology.
Resumo:
The probabilistic projections of climate change for the United Kingdom (UK Climate Impacts Programme) show a trend towards hotter and drier summers. This suggests an expected increase in cooling demand for buildings – a conflicting requirement to reducing building energy needs and related CO2 emissions. Though passive design is used to reduce thermal loads of a building, a supplementary cooling system is often necessary. For such mixed-mode strategies, indirect evaporative cooling is investigated as a low energy option in the context of a warmer and drier UK climate. Analysis of the climate projections shows an increase in wet-bulb depression; providing a good indication of the cooling potential of an evaporative cooler. Modelling a mixed-mode building at two different locations, showed such a building was capable of maintaining adequate thermal comfort in future probable climates. Comparing the control climate to the scenario climate, an increase in the median of evaporative cooling load is evident. The shift is greater for London than for Glasgow with a respective 71.6% and 3.3% increase in the median annual cooling load. The study shows evaporative cooling should continue to function as an effective low-energy cooling technique in future, warming climates.
Resumo:
Liquid desiccant cooling systems (LDCS) are energy efficient means of providing cooling, especially when powered by low-grade thermal sources. In this paper, the underlying principles of operation of desiccant cooling systems are examined, and the main components (dehumidifier, evaporative cooler and regenerator) of the LDCS are reviewed. The evaporative cooler can take the form of direct, indirect or semi-indirect. Relative to the direct type, the indirect type is generally less effective. Nonetheless, a certain variant of the indirect type - namely dew-point evaporative cooler - is found to be the most effective amongst all. The dehumidifier and the regenerator can be of the same type of equipment: packed tower and falling film are popular choices, especially when fitted with an internal heat exchanger. The energy requirement of the regenerator can be supplied from solar thermal collectors, of which a solar pond is an interesting option especially when a large scale or storage capability is desired.
Resumo:
Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Electrocaloric cooling based on ability of material to change temperature by applying an electric field under adiabatic conditions is relatively new and challenging direction of ferroelectrics research. In this work we report about analytical, simulation and experimental data for BaSrTiO3 thin film and bulk ceramic samples. Detailed discussion of a theoretical base of the electrocaloric effect is included. Demonstrated experimental and computational results exemplify rational approach to a problem of solid-state cooler construction.
Resumo:
Pigs are more sensitive to high environmental temperatures explained by the inability of sweating and panting properly when compared to other species of farmed livestock. The evaporative cooling system might favor the thermal comfort of animals during exposure to extreme environmental heat and reduce the harmful effects of heat stress. The purpose of this study was to assess the sensible heat loss and thermoregulation parameters from lactating sows during summer submitted to two different acclimatization systems: natural and evaporative cooling. The experiment was carried out in a commercial farm with 72 lactating sows. The ambient variables (temperature, relative humidity and air velocity) and sows physiological parameters (rectal temperature, surface temperature and respiratory rate) were monitored and then the sensible heat loss at 21days lactation was calculated. The results of rectal temperature did not differ between treatments. However, the evaporative cooling led to a significant reduction in surface temperature and respiratory rate and a significant increase in the sow's sensible heat loss. It was concluded that the use of evaporative cooling system was essential to increase sensible heat loss; thus, it should reduce the negative effects of heat on the sows' thermoregulation during summer.
Resumo:
The search for efficient and accessible cooling systems has increased worldwide. This study aims to build and evaluate an evaporative cooling system using a water driven ejector, allowing it to be installed in places with plenty of water. The system was investigated varying the flow rate and temperature of the circulating water, temperature of the replacement water, and coefficient of performance. The best vacuum obtained was 8.5 kPa at nominal operating conditions of 4.1 ± 0.1 m³/h and 5 ± 0.5 ºC for the circulating water reaching the temperature of 9.7 ± 0.5 ºC. The pulse-like disturbance generated by replacing the cooling water at different periods of times did not result in significant affect vacuum destabilization and the temperature rise in the cooling tank. The coefficient of performance of the system at the highest thermal power of 92.27 W was 0.077, which was underestimated due to possible problems related to pump efficiency. The system evaluated under the conditions proposed can be very efficient for cooling fluids at higher temperatures, and it can be complementary to main refrigeration systems.
Resumo:
Rattlesnakes use their facial pit organs to sense external thermal fluctuations. A temperature decrease in the heat-sensing membrane of the pit organ has the potential to enhance heat flux between their endothermic prey and the thermal sensors, affect the optimal functioning of thermal sensors in the pit membrane and reduce the formation of thermal ‘‘afterimages’’, improving thermal detection. We examined the potential for respiratory cooling to improve strike behaviour, capture, and consumption of endothermic prey in the South American rattlesnake, as behavioural indicators of thermal detection. Snakes with a higher degree of rostral cooling were more accurate during the strike, attacking warmer regions of their prey, and relocated and consumed their prey faster. These findings reveal that by cooling their pit organs, rattlesnakes increase their ability to detect endothermic prey; disabling the pit organs caused these differences to disappear. Rattlesnakes also modify the degree of rostral cooling by altering their breathing pattern in response to biologically relevant stimuli, such as a mouse odour. Our findings reveal that low humidity increases their ability to detect endothermic prey, suggesting that habitat and ambush sites election in the wild may be influenced by external humidity levels as well as temperature.
Resumo:
Native grasslands have been altered to a greater extent than any other biome in North America. The habitats and resources needed to support breeding performance of grassland birds endemic to prairie ecosystems are currently threatened by land management practices and impending climate change. Climate models for the Great Plains prairie region predict a future of hotter and drier summers with strong multiyear droughts and more frequent and severe precipitation events. We examined how fluctuations in weather conditions in eastern Colorado influenced nest survival of an avian species that has experienced recent population declines, the Mountain Plover (Charadrius montanus). Nest survival averaged 27.2% over a 7-yr period (n = 936 nests) and declined as the breeding season progressed. Nest survival was favored by dry conditions and cooler temperatures. Projected changes in regional precipitation patterns will likely influence nest survival, with positive influences of predicted declines in summer rainfall yet negative effects of more intense rain events. The interplay of climate change and land use practices within prairie ecosystems may result in Mountain Plovers shifting their distribution, changing local abundance, and adjusting fecundity to adapt to their changing environment.
Resumo:
The soluble metal sulphate salts melanterite, rozenite, rhomboclase, szornolnokite, copiapite, coquimbite, hexahydrite and halotrichite, together with gypsum, have been identified, some for the first time oil the banks of the Rio Tinto, SW Spain. Secondary Fe-sulphate minerals call form directly from evaporating acid, sulphate-rich Solutions as a result of pyrite oxidation. Chemical analyses of mixtures of these salt minerals indicate concentrations of Fe (up to 31 wt.%), Mg (up to 4 wt.%), Cu (up to 2 wt.%) and Zn (up to wt.%). These minerals are shown to act as transient storage Cor metals and can store on average up to 10% (9.5 - 11%) and 22% (20-23%) Zn and Cu respectively, of the total discharge of the Rio Tinto during the summer period. Melanterite and rozenite precipitates at Rio Tinto are only found in association with very acidic drainage waters (pH <1.0) draining directly from pyritic waste piles. Copiapite precipitates abundantly oil the banks of the Rio Tinto by (1) direct evaporation of the river water; or (2) as part of a paragenetic sequence with the inclusion of minor halotrichite, indicating natural dehydration and decomposition. The natural occurrences are comparable with the process of paragenesis from the evaporation of Rio Tinto river water under laboratory experiments resulting in the formation of aluminocopiapite, halotrichite, coquimbite, voltaite and gypsum.
Resumo:
This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.