918 resultados para Estroma corneal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diabetic neuropathy is a significant clinical problem that currently has no effective therapy, and in advanced cases, leads to foot ulceration and lower limb amputation. The accurate detection, characterization and quantification of this condition are important in order to define at-risk patients, anticipate deterioration, monitor progression, and assess new therapies This review evaluates novel corneal methods of assessing diabetic neuropathy. Two new non-invasive corneal markers have emerged, and in cross-sectional studies have demonstrated their ability to stratify the severity of this disease. Corneal confocal microscopy allows quantification of corneal nerve parameters and non-contact corneal esthesiometry, the functional correlate of corneal structure, assesses the sensitivity of the cornea. Both these techniques are quick to perform, produce little or no discomfort for the patient, and are suitable for clinical settings. Each has advantages and disadvantages over traditional techniques for assessing diabetic neuropathy. Application of these new corneal markers for longitudinal evaluation of diabetic neuropathy has the potential to reduce dependence on more invasive, costly, and time-consuming assessments, such as skin biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sericin and fibroin are the two major proteins in the silk fibre produced by the domesticated silkworm, Bombyx mori. Fibroin has been extensively investigated as a biomaterial. We have previously shown that fibroin can function successfully as a substratum for growing cells of the eye. Sericin has been so far neglected as a biomaterial because of suspected allergenic activity. However, this misconception has now been dispelled, and sericin’s biocompatibility is currently indisputable. Aiming at promoting sericin as a possible substratum for the growth of corneal cells in order to make tissue-engineered constructs for the restoration of the ocular surface, in this study we investigated the attachment and growth in vitro of human corneal limbal epithelial cells (HLECs) on sericin-based membranes. Sericin was isolated and regenerated from the silkworm cocoons by an aqueous procedure, manufactured into membranes, and characterized (mechanical properties, structural analysis, contact angles). Primary cell cultures from two donors were established in serum-supplemented media in the presence of murine feeder cells. Membranes made of sericin and fibroin-sericin blends were assessed in vitro as substrata for HLECs in a serum-free medium, in a cell attachment assay and in a 3-day cell growth experiment. While the mechanical characteristics of sericin were found to be inferior to those of fibroin, its ability to enhance the attachment of HLECs was significantly superior to fibroin, as revealed by the PicoGreen® assay. Evidence was also obtained that cells can grow and differentiate on these substrata.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Membranes prepared from a protein, fibroin, isolated from domesticated silkworm (Bombyx mori) silk, support the cultivation of human limbal epithelial (HLE) cells and thus display significant potential as biomaterials for ocular surface reconstruction. We presently extend this promising avenue of research by directly comparing the attachment, morphology and phenotype of primary HLE cell cultures grown on fibroin to that observed on donor amniotic membrane (AM), the current clinical standard substrate for HLE transplantation. Fibroin membranes measuring 6.3 ± 0.5 μm (mean ± sd) in thickness and permeable to FITC dextran of a molecular weight up to 70 kDa, were used. Attachment of HLE cells to fibroin was similar to that supported by tissue culture plastic but approximately 6-fold less than that observed on AM. Nevertheless, epithelia constructed from HLE on fibroin maintained evidence of corneal phenotype (K3/K12 expression) and displayed a comparable number and distribution of ΔNp63+ progenitor cells to that seen in cultures grown on AM. These results support the suitability of membranes constructed from Bombyx mori silk fibroin as substrata for HLE cultivation and encourage progression to studies of efficacy in preclinical models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Membranes prepared from Bombyx mori silk fibroin have shown potential as a substrate for human limbal epithelial (L-EC) and stromal cell cultivation. Here we present fibroin as a dual-layer construct containing both an epithelium and underlying stroma for corneolimbal reconstruction. We have compared the growth and phenotype of L-EC on non-porous versus porous fibroin membranes. Furthermore, we have compared the growth of limbal mesenchymal stromal cells (L-MSC) in either serum-supplemented medium or the MesenCult-XF® culture system within fibroin fibrous mats. The co-culture of L-EC and L-MSC in fibroin dual-layer constructs was also examined. L-EC on porous membranes displayed a squamous monolayer; in contrast, L-EC on non-porous fibroin appeared cuboidal and stratified. Both constructs maintained evidence of corneal phenotype (cytokeratin 3/12) and distribution of ΔNp63+ progenitor cells. L-MSC cultivated within fibroin fibrous mats in serum-supplemented medium contained less than 64% of cells expressing the characteristic MSC phenotype of CD73+CD90+CD105+ after two weeks, compared with over 81% in MesenCult-XF® medium. Dual-layer fibroin scaffolds consisting of L-EC and L-MSC maintained a similar phenotype as on the separate layers. These results support the feasibility of a 3D engineered limbus constructed from B. mori silk fibroin, and warrant further studies into the potential benefits it offers to corneolimbal tissue regeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diabetic neuropathy is a significant clinical problem that currently has no effective therapy, and in advanced cases, leads to foot ulceration and lower limb amputation. The accurate detection, characterisation and quantification of this condition are important in order to define at-risk patients, anticipate deterioration, monitor progression and assess new therapies. This thesis evaluates novel corneal methods of assessing diabetic neuropathy. Over the past several years two new non-invasive corneal markers have emerged, and in cross-sectional studies have demonstrated their ability to stratify the severity of this disease. Corneal confocal microscopy (CCM) allows quantification of corneal nerve parameters and non-contact corneal aesthesiometry (NCCA), the presumed functional correlate of corneal structure, assesses the sensitivity of the cornea. Both these techniques are quick to perform, produce little or no discomfort for the patient, and with automatic analysis paradigms developed, are suitable for clinical settings. Each has advantages and disadvantages over established techniques for assessing diabetic neuropathy. New information is presented regarding measurement bias of CCM images, and a unique sampling paradigm and associated accuracy determination method of combinations is described. A novel high-speed corneal nerve mapping procedure has been developed and application of this procedure in individuals with neuropathy has revealed regions of sub-basal nerve plexus that dictate further evaluation, as they appear to show earlier signs of damage than the central region of the cornea that has to date been examined. The discriminative capacity of corneal sensitivity measured by NCCA is revealed to have reasonable potential as a marker of diabetic neuropathy. Application of these new corneal markers for longitudinal evaluation of diabetic neuropathy has the potential to reduce dependence on more invasive, costly, and time-consuming assessments, such as skin biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop a rapid optimized technique of wide-field imaging of the human corneal subbasal nerve plexus. A dynamic fixation target was developed and, coupled with semiautomated tiling software, a rapid method of capturing and montaging multiple corneal confocal microscopy images was created. To illustrate the utility of this technique, wide-field maps of the subbasal nerve plexus were produced in 2 participants with diabetes, 1 with and 1 without neuropathy. The technique produced montages of the central 3 mm of the subbasal corneal nerve plexus. The maps seem to show a general reduction in the number of nerve fibers and branches in the diabetic participant with neuropathy compared with the individual without neuropathy. This novel technique will allow more routine and widespread use of subbasal nerve plexus mapping in clinical and research situations. The significant reduction in the time to image the corneal subbasal nerve plexus should expedite studies of larger groups of diabetic patients and those with other conditions affecting nerve fibers. The inferior whorl and the surrounding areas may show the greatest loss of nerve fibers in individuals with diabetic neuropathy, but this should be further investigated in a larger cohort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Arbitrary numbers of corneal confocal microscopy images have been used for analysis of corneal subbasal nerve parameters under the implicit assumption that these are a representative sample of the central corneal nerve plexus. The purpose of this study is to present a technique for quantifying the number of random central corneal images required to achieve an acceptable level of accuracy in the measurement of corneal nerve fiber length and branch density. Methods Every possible combination of 2 to 16 images (where 16 was deemed the true mean) of the central corneal subbasal nerve plexus, not overlapping by more than 20%, were assessed for nerve fiber length and branch density in 20 subjects with type 2 diabetes and varying degrees of functional nerve deficit. Mean ratios were calculated to allow comparisons between and within subjects. Results In assessing nerve branch density, eight randomly chosen images not overlapping by more than 20% produced an average that was within 30% of the true mean 95% of the time. A similar sampling strategy of five images was 13% within the true mean 80% of the time for corneal nerve fiber length. Conclusions The “sample combination analysis” presented here can be used to determine the sample size required for a desired level of accuracy of quantification of corneal subbasal nerve parameters. This technique may have applications in other biological sampling studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibroin extracted from silkworm cocoon silk provides an intriguing and potentially important biomaterial for corneal reconstruction. In the present chapter we outline our methods for producing a composite of two fibroin-based materials that supports the co-cultivation of human limbal epithelial (HLE) cells and human limbal stromal (HLS) cells. The resulting tissue substitute consists of a stratified epithelium overlying a three-dimensional arrangement of extracellular matrix components (principally ‘degummed’ fibroin fibers) and mesenchymal stromal cells. This tissue substitute is currently being evaluated as a tool for reconstructing the corneal limbus and corneal epithelium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:  For those in the field of managing diabetic complications, the accurate diagnosis and monitoring of diabetic peripheral neuropathy (DPN) continues to be a challenge. Assessment of sub-basal corneal nerve morphology has recently shown promise as a novel ophthalmic marker for the detection of DPN. Methods:  Two hundred and thirty-one individuals with diabetes with predominantly mild or no neuropathy and 61 controls underwent evaluation of diabetic neuropathy symptom score, neuropathy disability score, testing with 10 g monofilament, quantitative sensory testing (warm, cold, vibration detection) and nerve conduction studies. Corneal nerve fibre length, branch density and tortuosity were measured using corneal confocal microscopy. Differences in corneal nerve morphology between individuals with and without DPN and controls were investigated using analysis of variance and correlations were determined between corneal morphology and established tests of, and risk factors for, DPN. Results:  Corneal nerve fibre length was significantly reduced in diabetic individuals with mild DPN compared with both controls (p < 0.001) and diabetic individuals without DPN (p = 0.012). Corneal nerve branch density was significantly reduced in individuals with mild DPN compared with controls (p = 0.032). Corneal nerve fibre tortuosity did not show significant differences. Corneal nerve fibre length and corneal nerve branch density showed modest correlations to most measures of neuropathy, with the strongest correlations to nerve conduction study parameters (r = 0.15 to 0.25). Corneal nerve fibre tortuosity showed only a weak correlation to the vibration detection threshold. Corneal nerve fibre length was inversely correlated to glycated haemoglobin (r = -0.24) and duration of diabetes (r = -0.20). Conclusion:  Assessment of corneal nerve morphology is a non-invasive, rapid test capable of showing differences between individuals with and without DPN. Corneal nerve fibre length shows the strongest associations with other diagnostic tests of neuropathy and with established risk factors for neuropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:  The objective was to investigate the association between corneal sensitivity and established measures of diabetic peripheral neuropathy (DPN). Methods:  Corneal sensitivity was measured in 93 individuals with diabetes, 146 diabetic individuals without neuropathy and 61 control individuals without diabetes or neuropathy using a non-contact corneal aesthesiometer at the baseline visit of a five-year longitudinal natural history study of DPN. The correlation between corneal sensitivity and established measures of neuropathy was estimated and multi-dimensional scaling was used to represent similarities and dissimilarities between variables. Results:  The corneal sensitivity threshold was significantly correlated with a majority of established measures of DPN. Correlation coefficients ranged from -0.32 to 0.26. Using multi-dimensional scaling, non-contact corneal aesthesiometry was closer to the neuropathy disability score, diabetic neuropathy symptom score and Neuropad and most dissimilar to electrophysiological parameters and quantitative sensory testing. Conclusion:  Corneal sensitivity, although not strongly related, is associated with other functional measures of DPN and might provide a useful adjunct in identifying functional loss of small nerve fibre integrity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To examine the symmetry of corneal changes following near work in the fellow eyes of non-amblyopic myopic anisometropes. METHODS: Thirty-four non-amblyopic myopic anisometropes (minimum 1 D spherical equivalent anisometropia) were recruited. Corneal topography was measured with the Medmont E300 Videokeratoscope before and after a controlled near task. Subjects were positioned to minimise head movements and read continuous text on a computer monitor for 10 minutes at an angle of 25 degrees downward gaze and an accommodation demand of 2.5 D. Measures of palpebral aperture morphology during primary and downward gaze were also obtained using digital photography and analysed with customised software. RESULTS: Significant changes in corneal topography were observed after ten minutes of reading. Localised superior regions of corneal topographical change (a hyperopic shift in corneal power) were typically exhibited in both eyes following the near task. The mean change in the corneal sphero-cylinder was +0.02/-0.11 x 113 and +0.02/-0.06 x 68 for the more and less myopic eyes respectively for a 6 mm corneal diameter. A significantly greater change in corneal astigmatism power vector J0 (a larger increase in against the rule astigmatism) was observed in the more myopic eyes (p < 0.01 for a 6 mm diameter). The more and less myopic eyes exhibited a high degree of interocular symmetry for measures of palpebral aperture morphology during both primary and downward gaze. Changes in corneal power vectors following reading were associated with eyelid position during downward gaze. CONCLUSIONS: Changes in corneal topography observed following a controlled reading task were highly symmetrical between the fellow eyes of myopic anisometropes due to the interocular symmetry of the palpebral aperture. However, the more myopic eye did exhibit a small but significantly greater magnitude of change in corneal astigmatism compared to the less myopic eye following reading. These findings may have implications for understanding the mechanism of development of non-amblyopic myopic anisometropia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses. Method: Fourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day. Results: Anterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p ≤ 0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p ≤ 0.05). Conclusion: The corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the symmetry of corneal changes following near work in the fellow eyes of non-amblyopic myopic anisometropes. Methods: Thirty-four non-amblyopic, myopic anisometropes (minimum 1 D spherical equivalent anisometropia) had corneal topography measured before and after a controlled near work task. Subjects were positioned in a headrest to minimise head movements and read continuous text on a computer monitor for 10 minutes at an angle of 25 degrees downward gaze and an accommodation demand of 2.5 D. Measures of the morphology of the palpebral aperture during primary and downward gaze were also obtained. Results: The more and less myopic eyes exhibited a high degree of interocular symmetry for measures of palpebral aperture morphology during both primary and downward gaze. Following the near work task, fellow eyes also displayed a symmetrical change in superior corneal topography (hyperopic defocus) which correlated with the position of the upper eyelid during downward gaze. Greater changes in the spherical corneal power vector (M) following reading were associated with narrower palpebral aperture during downward gaze (p = 0.07 for more myopic and p = 0.03 for less myopic eyes). A significantly greater change in J0 (an increase in against the rule astigmatism) was observed in the more myopic eyes (-0.04 ± 0.04 D) compared to the less myopic eyes (-0.02 ± 0.06 D) over a 6 mm corneal diameter (p = 0.01). Conclusions: Changes in corneal topography following near work are highly symmetrical between the fellow eyes of myopic anisometropes due to the interocular symmetry of the palpebral aperture. However, the more myopic eye exhibits changes in corneal astigmatism of greater magnitude compared to the less myopic eye.