1000 resultados para Espectroscopia deabsorção de raios X (XAS)
Resumo:
In this work, the structures of LaCoO3, La0,8Ba0,2CoO3 and La0,8Ca0,2CoO3 perovskites were characterized as a function of temperature (LaCoO3 structure being analyzed only at room temperature). The characterization of these materials were made by X-Ray Absorption Spectroscopy (XAS), in the cobalt K-edge, taking into account the correlated Einstein model X-ray absorption fine structure (EXAFS). The first part of the absorption spectrum corresponded the X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS). These materials were prepared by the combustion method. The combustion products were calcinated at 900 0C, for 6 hours in air. Noted that the sample LaCoO3 at room temperature and samples doped with Calcium and Barium in the temperature range of 50 K to 298 K showed greater distortion to monoclinic symmetry with space group I2/a. However, the sample doped with barium at the temperatures 50 K, 220 K, and 260 K showed a slight distortion to rhombohedral symmetry with space group R-3c. The La0,8Ca0, 2CoO3 structure was few sensitive to temperature variation, showing a higher local distortion in the octahedron and a higher local thermal disorder. These interpretations were in agreement with the information electronic structural on the XANES region and geometric in the EXAFS region
Resumo:
This work deals with the application of X-Ray Absorption Spectroscopy on the study of the behavior of Cu2+ ions in inverse micelles. The formation of copper nanoparticles in water-in-oil microemulsions in pseudo-ternary systems of cetyl trimethylammonium Bromide (CTAB) surfactant, butanol co-surfactant, heptane as oil phase and aqueous solutions of CuSO4.5H2O, and NaBH4. The microemulsions were prepared with a fixed percentage (60 %) of oil phase and a variable water to tensoative proportion. It was observed an increase on Cu2+ reduction by the sodium borohydride in microemulsions with 13 % of aqueous phase, independent of the reaction time. For the microemulsions in which the aqueous phase is composed only by the CuSO4 solution, it was observed that the color of the solution depends on the water to surfactant ratio. These changes in color were attributed to a competition for the hidratation water between the polar head of the tensoative and Cu2+ ions with the eventual substitution of oxygen by bromine atoms in the first coordination shell of Cu2+ ions
Resumo:
In chemical industry, petrochemical and oil refinery may be found situations that working pressures and very high temperatures, and alloys that comprise such equipment must have specific characteristics such. As a way to ensure that the materials are as designed, companies have some specific techniques, and one of them is X-ray fluorescence spectrometry, which allows its application in devices small and lightweight, which ensures its portability in field use. This technique however, has some shortcomings such as the impossibility of detecting carbon and other elements of low atomic number which can generate false identifications of elements that are not in the league or non-detection of existing elements. Therefore, this study investigated the reliability of this method using the apparatus Niton XL3t 800 and may conclude that their results are reliable and can be used to assist in ensuring the operational integrity of the production units of these companies
Resumo:
A espectroscopia de fotoelectrões de raios-X (XPS - X-ray Photoelectron Spectroscopy)é uma das técnicas de análise de superfícies mais importantes e mais usadas em diversasáreas científico-tecnológicas e industriais. Com ela é possível determinar quantitativa equalitativamente a composição elementar e a composição química aproximada, respectivamente,e estrutura electrónica dos elementos presentes para diferentes tipos de materiais. O laboratório de ciência de superfícies do Departamento de Física da FCT-UNL encontra-se equipado com um sistema de ultra-alto vácuo Kratos XSAM 800 contendo a instrumentação necessária para se realizar XPS. No entanto, o equipamento precisava de uma requalificação. O controlo e aquisição de dados do espectrómetro era feito por um computador PDP11 de 16-bits que actualmente não é comercializado e não tem qualquer suporte técnico por parte do fabricante. Foi substituído por um computador moderno e por uma placa genérica de aquisição de dados. Para que a análise quantitativa pela técnica de XPS seja precisa, é necesssário fazer a caracterização do sistema. Isso implica o conhecimento de parâmetros como a função de transmissão do espectrómetro e a linearidade da resposta do sistema de detecção. Foi feito um estudo da linearidade da resposta do sistema de detecção e determinou-se experimentalmente a função de transmissão do espectrómetro. Os resultados obtidos para a função de transmissão mostraram estar qualitativamente de acordo com os resultados obtidos por outros na literatura. A transmissão da coluna óptica do analisador de energia de electrões foi posteriormente submetida a um processo de optimização, através da implementação de um algoritmo evolutivo diferencial para optimização de funções, recorrendo a linguagem de programação gráfica LabVIEWTM.
Resumo:
The objective of this work was to accomplish the simultaneous determination of some chemical elements by Energy Dispersive X-ray Fluorescence (EDXRF) Spectroscopy through multivariate calibration in several sample types. The multivariate calibration models were: Back Propagation neural network, Levemberg-Marquardt neural network and Radial Basis Function neural network, fuzzy modeling and Partial Least Squares Regression. The samples were soil standards, plant standards, and mixtures of lead and sulfur salts diluted in silica. The smallest Root Mean Square errors (RMS) were obtained with Back Propagation neural networks, which solved main EDXRF problems in a better way.
Resumo:
The potentialities of X-ray Absorption Near Edge Spectroscopy (XANES) of the N K edge (N K) obtained with the spherical grating monochromator beam line at the Brazilian National Synchrotron Light Laboratory are explored in the investigation of poly(aniline), nanocomposites and dyes. Through the analysis of N K XANES spectra of conducting polymers and many other dye compounds that are dominated by 1s®p* transitions, it was possible to correlate the band energy value with the nitrogen oxidation states. An extensive N K XANES spectral database was obtained, thus permitting the elucidation of the nature of different nitrogens present in the intercalated conducting polymers.
Resumo:
Coprolites are fossilized faeces that constitute an important source of palaeobiological informations. This paper describes the characterization of some coprolite materials originated from the Romualdo Member of the Santana Formation (Araripe Basin, south of Ceará State in Brazil) by means of two techniques: X-ray powder diffraction and Fourier transform infrared spectroscopy (FT-IR). This characterization allowed us to determine the main composition of the coprolites, of the nodulus (where the coprolites were extracted) and of the sediment (where the nodulus was found) suggesting that the material was produced by a carnivorous fish of the Lower Cretaceous.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A espectroscopia de raios-X por reflexão total (TXRF) é uma técnica promissora para análise de elementos-traço (ETs), principalmente por não ser necessária a digestão das amostras, reduzindo assim a geração de resíduos e emissão de vapores tóxicos. Este trabalho comparou os teores dos ETs: Cr, Mn, Ni, Zn, Cu, As, Se, Hg e Pb, coletados em solos de área de agricultura intensiva e vegetação nativa, determinados por TXRF e por espectrometria de absorção atômica de chama ou forno de grafite (FAAS/GFAAS). Adicionalmente, compararam-se os teores dos ET com valores de referência para solos não contaminados. As amostras de solo foram coletadas na profundidade 0,0-0,2 m em municípios representativos de cada região agrícola do Estado de Mato Grosso (Rondonópolis, Alto Garça, Primavera do Leste, Campo Novo, Nova Mutum, Lucas do Rio Verde, Sorriso, Sinop, Campo Novo dos Parecis, Campos de Julho e Vila Bela da Santíssima Trindade). Em cada município, foram selecionadas seis áreas, totalizando 72 amostras, todas georreferenciadas. Para a leitura dos teores de ET no aparelho de TXRF S2 Picofox™, foram preparadas suspensões de solo usando Triton X-100 a 5 % v/v utilizando gálio como padrão interno, enquanto no FAAS/GFAAS as amostras foram submetidas à digestão ácida pelo método 3051A. Considerando área cultivada e área nativa, respectivamente, os teores médios dos ET por TXRF, em mg kg-1, foram: Cr, 69 e 62; Zn, 16 e 8; Pb, 28 e 21; Mn, 56 e 42; As, 2 e 2; Cu, 9 e 8; e Ni, 2 e 2. O Cd, Se e Hg não foram detectados por TXRF nas amostras analisadas. Para As, Cr, Mn, Zn, Ni, Cu e Pb, houve correlação linear (p<0,001) positiva entre as técnicas e, no geral, os teores obtidos para esses ET em TXRF foram superiores aos do FAAS/GFAAS. Os teores de todos os elementos detectados pelo TXRF, exceto o Cr, estão dentro das faixas dos relatados para solos não contaminados e muito inferiores aos limites de alerta estipulados na literatura.
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
As normas nacionais e internacionais prevêem que a manutenção dos níveis de radiação deve estar abaixo do permitido. Sendo assim, a ICRP [1] (International Commission on Radiological Protection) exige métodos de otimização para garantir que o público esteja exposto aos menores níveis de radiação possíveis. Como método de otimização, aproximações teóricas e semi-empiricas podem realizar uma determinação do espectro de raios-X, sendo fundamental para o diagnóstico de energia, estimando a dose de radiações em pacientes e formulando modelos de blindagem. Métodos adequados de radioproteção foram desenvolvidos na física médica como a medicina nuclear, a radioterapia e a radiologia diagnóstica. Um dos métodos semi-empiricos utilizados é o modelo de TBC que é capaz de reproduzir e calcular os espectros gerados pelo anodo de tungstênio. Com o modelo de TBC modificado é possível também obedecer às exigências das barreiras protetoras presentes na radiologia, levando em conta a forma de onda arbitrária e a filtração adicional na geração do espectro não presente no modelo original. Além disso, realiza-se a calibração do espectro gerado para que o modelo de TBC represente a quantidade e comportamento de radiações típicas. Dessa forma, realiza-se uma revisão do modelo de TBC implementando-o ao programa matemático Matlab e comparando-o com os resultados adquiridos pelo Código MCNP-5 no Método de Monte Carlo. Os resultados encontrados são bastante satisfatórios, tanto em termos quantitativos quanto qualitativos dos feixes. Para a calibração, desenvolve-se uma análise dos espectros gerados pelo TBC Modificado aplicado ao programa Mathcad e Matlab sob as mesmas condições. Os espectros gerados apresentam o mesmo comportamento, diferindo em até 12% nos valores encontrados para camadas semi-redutoras, coeficiente de homogeneidade e energia efetiva
Resumo:
The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application
Resumo:
Pós-graduação em Química - IQ